Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 108 RZC C SECTOR 01 MAHAVIR ENCLAVE SOUTH WEST DELHI 110045 | DELHI | SOUTH WEST DELHI | DELHI | 110045 | Admitted-Finance |
| 2 | Admitted-Finance 86 UNIVERSAL INDUSTRIAL ESTATE I B PATEL ROAD GOREGAON EAST MUMBAI 400063 | MUMBAI SUBURBAN | MAHARASHTRA | 400063 | Admitted-Finance |
| 3 | Admitted-Finance 22 BEHIND MODERN PETROL PUMP BEHIND MODERN PETROL PUMP JHALAWAR ROAD KOTA KOTA RAJASTHAN 324007 | KOTA | RAJASTHAN | 324007 | Admitted-Finance |
| 4 | Admitted-Finance 336 GOYAL AVENUE NIPANIYA INDORE MADHYA PRADESH 452010 | INDORE | MADHYA PRADESH | 452010 | Admitted-Finance |
| 5 | Admitted-Finance 288 SHOPPING CENTER KOTA RAJASTHAN | KOTA | KOTA | RAJASTHAN | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
29 Jan 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SE(MM) KaTPP ,Jhalawar
ADMIN BUILDING KaTPP NEAR UNDAL VILLAGE DIST JHALAWAR RAJASTHAN
SUPPLY OF PRESSURE TRANSMITTER AND DIFFERENTIAL PRESSURE TRANSMITTER AT KATPP, JHALAWAR
2020_RRVUN_207344_1
TN-715(MM)
Open Tender
Electronics Equipment
Item Wise
90 days
KaTPP NEAR UNDAL VILLAGE JHALAWAR
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Sr.AO,KaTPP,RVUN,Jhalawar
₹40,000
29 Oct 2021
14 Dec 2020
29 Jan 2021
14 Dec 2020
29 Jan 2021
14 Dec 2020
180 days
DP Measuring Range: -500 to 500 Kpa User Range/calibration Range: 0 to 250 Kpa
DP Measuring Range: -800 to 800 mmH2O User Range/calibration Range: -600 to 500 mmH2O
DP Measuring Range: -2.0 to 2.0 Kpa User Range/calibration Range: 0.1 to 1.5 Kpa
DP Measuring Range: -0.12 to 10.0 Mpa User Range/calibration Range: 0 to 10.0 Mpa
DP Measuring Range: -500 to 500 Kpa User Range/calibration Range: 0 to 500 Kpa
DP Measuring Range: -160 to 160 Kpa User Range/calibration Range: 0 to 60 Kpa
DP Measuring Range: 0.0 to 1500 mmH2O User Range/calibration Range: 0.0 to 1500 mmH2O
DP Measuring Range: 0 TO 8500 mmH2O User Range/calibration Range: 0 TO 8500 mmH2O
DP Measuring Range: 0 TO 13000 mmH2O User Range/calibration Range: 0 TO 13000 mmH2O
PT Measuring Range: -8.0 to 8.0 Kpa User Range/calibration Range: -8.0 to 1.0 Kpa
PT Measuring Range: -0.1 to 40.0 Mpa User Range/calibration Range: 0 to 30.0 Mpa
PT Measuring Range: -60 to 60 Kpa User Range/calibration Range: -7.0 to 7.0 Kpa
PT Measuring Range: -100 to 400 Kpa User Range/calibration Range: 0 to 30.0 Kpa
PT Measuring Range: -2.0 to 2.0 Kpa User Range/calibration Range: 0 to 2.0 Kpa
PT Measuring Range: -0.1 to 16.0 MPa User Range/calibration Range: 0 to 15.0 Mpa
PT Measuring Range: 0-30 MPa User Range/calibration Range: 0-30 Mpa
PT Measuring Range: 0-10 MPa User Range/calibration Range: 0-10 Mpa
PT Measuring Range: 0-6 MPa User Range/calibration Range: 0-6 MPa
PT Measuring Range: 0-2 MPa User Range/calibration Range: 0-2 MPa
PT Measuring Range: -2 to 2 MPa User Range/calibration Range: -1 to 2 Mpa
PT Measuring Range: -1 to 0.1 MPa User Range/calibration Range: -1 to 0.1 Mpa
PT Measuring Range: -0.1 to 0.5 MPa User Range/calibration Range: -0.1 to 0.5 Mpa
PT Measuring Range: 0-5500 KPa User Range/calibration Range: 0-5500 KPa
PT Measuring Range: -100 to 100 MPa User Range/calibration Range: -100 to 100 Mpa
PT Measuring Range: 0-100 MPa User Range/calibration Range: 0-100 Mpa
DPT Measuring Range: 0-160 Kpa User Range/calibration Range: 0-160 Kpa
PT Measuring Range: -100 to 600 KPa User Range/calibration Range: -100 to 600 Kpa
DPT Measuring Range: 0-250 KPa User Range/calibration Range: 0-250 Kpa
PT Measuring Range: 43-1300 mbar User Range/calibration Range: 43-1300 mbar
DPT Measuring Range: 0-40 KPa User Range/calibration Range: 0-40 Kpa
PT Measuring Range: 0-5 MPa User Range/calibration Range: 0.1 to 5 Mpa
PT Measuring Range: 0 to 6.3 MPa User Range/calibration Range: 0.1 to 1.5 Mpa
PT Measuring Range: 0-40 MPa User Range/calibration Range: 0 -25 Mpa
DPT Measuring Range: -60 to 60 KPa User Range/calibration Range: 0 to 5 Kpa
DPT Measuring Range: -500 to 500 KPa User Range/calibration Range: -100 to 100 Kpa
DPT Measuring Range: -160 to 160 KPa User Range/calibration Range: 0 to 100 Kpa
DPT Measuring Range: 0 to 40 KPa User Range/calibration Range: 0-20 Kpa
DPT Measuring Range: 0 to 8 KPa User Range/calibration Range: 0 to 6.2 Kpa
BALDOTA CONTROL AND EQUIPMENTS PVT LTD
AAKANKSHA ENTERPRISES
TRADE CENTRE
Saturn Engineering Services
NEW AGE TRADE CENTRE
BALDOTA CONTROL AND EQUIPMENTS PVT LTD
TRADE CENTRE
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .