Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 CrAccepted-AOC 123 B CENTRAL AVENUE SAINIK FARMS SOUTH DELHI DELHI 110062 | SOUTH DELHI | DELHI | 110062 | ₹9.2 Cr Quoted ₹9.3 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹9.4 Cr+₹5.6 L (0.60%)Rejected-Finance | ₹9.4 Cr+₹5.6 L (0.60%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹10.3 Cr+₹97.7 L (10.5%)Rejected-Finance | ₹10.3 Cr+₹97.7 L (10.5%) | L3 | Rejected-Finance Not being lowest |
| 4 | L4₹10.8 Cr+₹1.5 Cr (15.7%)Rejected-Finance | ₹10.8 Cr+₹1.5 Cr (15.7%) | L4 | Rejected-Finance Not being lowest |
| 5 | L5₹11.5 Cr+₹2.2 Cr (23.3%)Rejected-Finance | ₹11.5 Cr+₹2.2 Cr (23.3%) | L5 | Rejected-Finance Not being lowest |
Tender Value
Refer Docs
EMD Value
₹7.5 L
Closing Date
30 Mar 2022, 6:00 pmClosed
Chief Engineer Delhi Zone
HQ Chief Engineer Delhi Zone, Delhi Cantt-10
ADDN/ALTN AND UPGRADATION OF 16 JCO P-20 AND P-21 AND 64 OR P-1/P-8, P-10 AND P-17 AT BASANTARA LINE AND 104 QTRS P-29, P-32, P-50, P-52, P-54 TO P-56, P-65 TO P-67 AT NEW CHITRA LINE UNDER GE(WEST) DELHI CANTT-10
2021_MES_498307_1
CEDZ-41 OF 2021-2022
Open Tender
Civil Works
Item Rate
365 days
Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹2,000
GE West
₹7.5 L
Yes
7 May 2022
3 Jan 2022
1 Apr 2022
3 Jan 2022
30 Mar 2022
16 Mar 2022
Amount
Taking down door frames or chowkhats not exc. 1.5 sq. m with shutters (without taking off shutters from the frames) , complete all as specified and directed.
Taking down chowkats or frames exc. 1.5 sq. m but not exc 4 sqm each with shutters (without taking off shutters from the frames) , complete all as specified and directed.
Taking down shutter of any description exc 1.00 sq. m but not exc 2.00 sqm each and refixed in the same opening complete all as specified and directed.
Taking down shutters of any description exc 1 sq. m but not exc 2 sqm each, complete all as specified and directed.
Taking down old window / ventilators with frame, any description, including guard bars not exc 1.5 sqm each , complete all as specified and directed.
M&L for powder coated (poweder coating of any colour and havning thickness not less than 50 micron) aluminium ventilator, openable, top hung and bottom portion fixed type without sash bars with aluminium section of weight 0.55 kg/RM including glazing, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws and top hung shutter fixed hook & eye minimum one no on each shutter, one no aluminium tower bolt 100mm long and 75mm long aluminium handle in each shutter etc. complete all as specified and directed. Note : glazing, wire mesh shall be measured and paid separately against respective items.
S&F powder coated (minimum thickness of powder coating 50 micron) aluminium frame (weight not less than 1.160 kg/RM) 2nd class wooden batten in inside of aluminium vertical section for fixing of screws for and including side hung window shutter with two glazed shutters and two guazed shutter including each shutter 02 Nos of 100mm long aluminium tower bolt (upper side and lower side), 02 Nos SS hinges, 100mm powder coated aluminium , stoppers and rubber beading gasket without sash bar aluminum section weighing 1.06 Kg/RM including necessary jointing cleats glazing clips rubber packing powder coated aluminum beading screws including fittings in each shutter with 5 mm thick tinted glass & also including stainless steel wire cloth of 0.36 mm dia and avg width of aperture 1.40 mm complete all as specified and directed. Note:- Rate of 5mm thick tinted glass and SS wire cloth is included in item rate.
S & F for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors, angle iron chowkhats; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 including fixing of hold fast with bed block of size 200x200x150 mm in concrete 1:2:4 (using 20mm graded agg complete all as specified and directed. .
M & L for 1mm thick Mild steel, plain, black sheet in hearths ; covering to door shutters; covering to door chowkhats ( frames); chullah hoods ; water tanks; water troughs; ducts;urinal troughs and funnels, etc. cut to size , edges beaded if directed, holes punched; including round headed screws , clout nails or rivets and fixed to wood or steel members, etc., with plain 40 mm lap joints or welded/ riveted seams, including bending, turning up, mitred angles, stopped ends, outlets , etc. as required, complete all as specified and directed by the Engr-in-Charge.
S&F 35 mm thick 2nd class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, cla-use 8.24 (a); supplied and fitted to chowkats as speicifed and directed.
S & F factory made 35 mm thick 2nd class hardwood Plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated incl one shop coat of pink primer all as specified and directed.
S&F 25mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides as shutter of cupboard complete all as specified & directed.
S&F fibre glass reinforced plastic (FRP) door frame shall be three legged of cross section 90mmx45mm having single rebate of 32mmx15mm to receive shutter of 30mm thickness. The laminate door frame moulde with fire retardant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibre glass from all sides. MS stay shall be provided at the bottom to steady the frame as per sample kept on GE's office complete all as specified & directed.
S&F FRP door shutter 30mm thick glass fibre reinforced plastic (FRP) panelled door shutter of required colour and approved brand and manufacturer made with retardant grade unsaturated poyester resin moulded to 3mm thick FRP laminate for forming hollow rails and styles with wooden frame and suitable blocks of seasoned wood inside at required places for fixing of fittings, cast monolithically with 5mm thick FRP panels and confirming to IS 14856-2000 supply and fixing in the frame at site complete all as per sample kept on GE's office complete all as specified & directed.
S&F 100 mm Stainless steel butt hinges medium weight fixed to PVC doors with SS screws complete all as specified and directed.
S&F 100 mm butt hinges medium weight cold rolled mild steel complete all as specificed and directed.
S & F 200mm long aluminum, anodized barrel tower bolts of extruded section complete all as specified & directed.
S & F 150mm long aluminum, anodized barrel tower bolts of extruded section complete all as specified & directed.
S & F aluminum anodised handle 150 mm long cast type complete all as specified & directed.
S & F aluminum anodised handle 125 mm long cast type complete all as specified & directed.
S & F 300mm long aluminium alloy anodised sliding door bolt with hasp staple (bolt type) and fixing clips of sheet cast or extruded section fixing bolts and sliding bolts of extruded section complete all as specified & directed.
S & F 150mm long aluminium alloy anodised hasp and staple, safety type, with hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed.
S&F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples (for windows and gauzed doors) all as specified and directed
S&F figured glass, 4mm thick, pin head type fixed with clips or glazing with oil putty complete in squares n.exc 0.50 Sqm each pane complete all as specified and directed.
S&F for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, fixing of nuts and bolts as necessary, gusset plates, riveting, etc., conforming to Fe -290 Gde E-165 complete all as specified and directed.
S&F for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/chajjas covering/cladding to wall fixed with self tapping screws incl cutting of chase in wall and inserting 50 mm deep, and making good and matching the surface with existing finish, complete all as specified and directed.
M&L for preparation of new steel surfaces over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel painting over a coat of red oxide primer etc all as specified and directed.
M & L for preparation of new or previously untreated wood or wood based surface of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint (approved tint) over a coat of pink primer complete as specified and directed.
S&F in repair110 mm bore PVC (SWR) pipes single socket in any length with rubber ring/ cement solvent cement jointsfixed to walls incl MS clamps of suitable size made of flat iron 25x3mm including taking down old unsv pipes complete all as specified and directed.
S&F PVC bend/tee suitable for 110mm bore pipe complete all as directed
S&F in repair stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples (for windows and gauzed doors) all as specified and directed
Demolition of reinforced cement concrete roofs, floors (other than groung floor), beams, staircases, landing, chajjas and similar suspended work .
M&L for ready mix concrete (RMC) of design mix M-25 (using 20mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs landings, balconies canopies,deck slabs and in shelves and the like complete all as specified and directed. Make: ACC/LAFARZ/BIRLA
S&F TMT bars 10mm dia and over, cut to lenght, bent to shape required, including cranking, bending spirally for hooping for coloums, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips as specified and directed.
S&F TMT bars 6mm to 8mm dia cut to lenght, bent to shape required, including cranking, bending spirally for hooping for coloums, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips as specified and directed.
All as per Srl item No. 35 above but TMT bars 5mm dia and over upto and including 10mm dia as in stirrups, spacers and binders.
M&L form work to soffits of suspended slab such as roof beams/slabs, chhajja, floor slabs, cover slab, shelves, landing and similar work not exc. 200mm thickness finished rough (horizontal or sloping) as specified and directed.
M&L form work to sides and soffits of floor or roof beams, beams, haunchings, griders bressummers lintels, cantilevers shelves including sup-ports, overhangs, etc also splays between floors and beams etc, complete all as specified and directed.
M&L rendering 15 mm thick in ready mix mortar on fair faces of brick or concrete surfaces finished fair and even with using extra cement incl water proofing compound @ 3% by weight of cement and taking down old cement plaster of any description, complete all as specified and directed. Make: ACC/LAFARZ/BIRLA Note:- (i) Cost for necessary steel formwork & shuttering of the above aspects shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
M&L rendering 15 mm thick in ready mix mortar on fair faces of brick or concrete surfaces finished fair and even with using extra cement incl water proofing compound @ 3% by weight of cement, complete all as specified and directed.Make: ACC/LAFARZ/BIRLA Note:- (i) The rendering is to be done in cement and sieved badarpur sand only (1:4).(Supplying integral WPC is included in this unit rate.) (ii) Cost for necessary steel formwork & shuttering of the above aspects shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
M&L for rendering 15 mm thick ready mix mortar on fair face of brick work/ concrete surfaces and finished even and smooth without using extra cement incl taking down old plaster, complete all as specified and directed. Make: ACC/LAFARZ/BIRLA
M&L for rendering 15 mm thick mix in ready mix mortar on fair face of brick work/ concrete surfaces and finished even and fair without using extra cement complete all as specified and directed. Make: ACC/LAFARZ/BIRLA
M&L for rendering 5 mm thick mix in ready mix mortar including applying neat cement slurry on ceiling and finished even and smooth without using extra cement complete all as specified and directed. Make: ACC/LAFARZ/BIRLA
M&L for rendering 10 mm thick in ready mix mortar including applying neat cement slurry on ceiling and finished even and smooth without using extra cement incl taking down old plaster, complete all as specified and directed. Make: ACC/LAFARZ/BIRLA
M&L for complete removal of existing treatment on walls to the entire satisfaction of Engr-in-Charge including preparation of surfaces and applying two coat of cement base paint complete all as specified and directed.
M&L for preparing newly plastered surfaces on walls and applying two coat of cement base paint over a coat of alkali resistant primer complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls applying birla white putty 2mm on wall even and smooth surface and applying two coat of oil bound distemper over a coat of alkali resistance primer (of approved quality and tint) on wall using painting roller, complete all as specified and directed.
M&L for complete removal of existing treatment by brooming down or steel wire brushing, scrapping down smoke, mass, efflorescent salt and oil and greesy spot etc. washing rubbing down distemper surfaces and applying birla white putty 2mm on wall even and smooth surface and applying two coat of oil bound distemper over a coat of primer (of approved quality and tint) on wall using painting roller, complete all as specified and directed.
M&L for preparation of old decorated surfaces and applying two coats of white wash on ceiling complete all as specified and directed.
M&L for preparation of new plastered surfaces and applying two coats of white wash on ceiling complete all as specified and directed.
Demolition of cement concrete unreinforced in ground floor and paving n.exc 15CM thickness (below or above ground levelall as specified and directed.
75 mm thick, PCC (1:4:8), type D-2 (using 40 mm graded stone aggregate), as in sub base under floor complete all as specified.
50mm thick fine sand layer spread uniformly over sub base complete all as specified.
Machine pressed precast concrete interlocking tiles/paver block any colour, shape and size (as approved by GE) conforming to IS 15658 of 80mm thickness M-40 grade with grey cement and no pigment including filling the joints upto full depth with fine sand, complete all as specified and directed by Engr-in-Charge.
M&L for Plinth protection 75 mm thick in PCC 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) laid in alternate bays(not exc 2 Sqm each) finished even and fair at top using extra cement and providing joints throughout the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 graded and three parts of sand by weight all as directed at site complete all as specified and directed.
S&F in repair 100mm dia CI spun soil, waste and vent pipes in any length, with or without ears, with cement joints, fixed to walls including dismantling of old unsv pipes, complete all as specified and directed.
S&F in repair 75mm CI spun soil, waste and vent pipe in any length with or without ears with cement joints fixed to walls, including dismantling of old unsv pipes complete all as specified and directed.
S&F in repair 100mm dia CI spun soil, waste and vent pipes in any length, with or without ears, with run lead joints, laid in trenches or in floors including dismantling of old unsv pipes, complete all as specified and directed. (Run lead shall be measured and paid separately).
All as per Srl item No. 58 above but 75mm dia
M & L for run lead joint for spigot or socket joints of 100mm dia spun pipes complete all as specified and directed by the Engr-in-Charge.
All as per Srl item No. 60 above but 75mm dia
S&F in repairs 100mm bore spun cast iron bends/Tee (any radius) diminishing pieces or tapers (larger bore to be measured) with oval access doors complete all as spd and directed.
All as per item No. 62 above but 75mm bore of pipe.
S&F CI Cowl for 100mm bore of CI pipe.
S & F 75mm dia CI floor trap with grating including jointing to waste pipe with lead joint, fixed complete all as specified & directed.
M & L for preparation of old painted wood or wood based surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (approved tint) complete as specified and directed.
Material and labour for preparation of old steel surface of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint (approved tint) complete as specified and directed.
Demolition of brick work or stone/boulder masonry built in cement mortar incl all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and Precast concrete articles, complete all as sfd and directed.
M&L for Brick work with Sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in Cement mortar 1:6
M&L for Brick work with Sub class 'B' bricks straight or curved on plan to any radious in half brick thick walls, built in Cement mortar 1:4 complete all as specified and directed.
M&L for Providing precast cement concrete type B0 1:2:4 (12.5 mm graded agg) louvres and jallies, 25mm thick (measured solid), including all mouldingsfixed to brick/concrete surfaces with cement mortor 1:4 complete all as specified and directed.
S&F GI tubing medium grade15mm bore with all fittings and fixed complete to wall and ceiling or laid in floors inlcuding cutting chases for inserting GI tubing in walls, floor etc and making good incl taking down old steel GI tubing 15mm complete all as specified and directed.
S&F GI tubing medium grade 20mm bore with all fittings and fixed complete to wall and ceiling or laid in floors incl taking down old steel GI tubing 20mm complete all as specified and directed.
S&F in repair vitreous chinaware wash hand basin flat back of size 550mm x 400mm complete including provision of pair of mild steel angle iron brackets of suitable size duly painted, 32 mm dia chromium plated waste coupling, PVC waste pipe and cutting for pinning in ends of brackets in wall etc complete all as specified and directed.
S&F in repair viterous china squatting pan (orissa pattern) long pan size 580x440mm white with integral footrest with 'P' or 'S' trap complete (excluding flushing cistern and flush pipe), connection to tarap (leakage proof) etc and make functional complete all as specified and directed.
S & F vitreous china, white european type water closet 580 mm including PVC seat cover, fixing with brass bolts, jointing to flushing cistern and flush pipe complete all as specified and directed.
M & L for hand shower (health faucet) (ABS chromium plated ) with 8mm dia, 1m long flexible tube and wall hook complete all as specified and directed.
S&F in repair curtain rods of stainless steel 25mm dia with and including SS decorative finials and SS brackets suitable for SS curtain rod fixed on wall etc complete all as specified & directed. Note : - (a) Only length of SS curtain rod shall be measured and paid. (b) SS decorative finisals and brackets shall be provided for each curtain rod and rate shall be incuded with SS curtain rod.
S&F curtain rods of stainless steel 25mm dia with and including SS decorative finials and SS brackets suitable for SS curtain rod fixed on wall etc complete all as specified & directed. Note : - (a) Only length of SS curtain rod shall be measured and paid. (b) SS decorative finisals and brackets shall be provided for each curtain rod and rate shall be incuded with SS curtain rod.
S&F in repair 15 mm bore angle valve, cast copper alloy screwed down high pressure with capstain head with long shank & cup complete all as specified and directed.
S&F 15 mm bore angle valve, cast copper alloy screwed down high pressure with capstain head with long shank & cup complete all as specified and directed.
S & F 15 mm dia two way angle valve cast copper alloy chromium plated with capstan head handle, screwed down high pressure screwed for iron pipe or for brass ferrule complete all as specified & directed.
S&F in repair 15mm dia bib tap long body fancy type, screwed down, screwed for iron pipe, cast copper alloy, chromium plated with flange complete all as specified and directed.
S&F in repair 15mm dia bib tap with capstan head, screwed down, screwed for iron pipe, fancy type, cast copper alloy, chromium plated with wall flange complete all as specified and directed.
S&F 15mm dia bib tap with capstan head, screwed down, screwed for iron pipe, fancy type, cast copper alloy, chromium plated with wall flange complete all as specified and directed.
S&F Brass CP mixer for mixing hot & cold water (for wash hand basin) and fixed including dismantling of 15mm dia chromium plated pillar tap, complete all as specified and directed.
S&F in repair stop valve fancy type chromium plated with long shank and cup (Concealed type) with screwed down both ends for high pressure suitable for 15 mm dia iron pipe all as specified.
S & F in repair CP shower rose 150x150mm with 190mm long shower arm rod all as specified and directed.
S&F in repairs 20mm bore of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as spd & directed.
S & F PVC connection 15mm dia & 600mm long for hot water using with gyser with two nos brass check nuts complete all as specified & directed.
S&F in repair sink made of stainless steel 1mm thick for kitchen with plugs, washers and waste including bedding in cement mortar to dwarf wall or including fixing cantilever, brackets and connecting union to pipe over all size 495 x 420 mm, bowl size 410 mm x 330 mm x 160mm complete all as specified and directed.
S&F in repairs PVC low level white flushing cistern, valveless syphonic action type 10 ltr capacity with inlet, ball valve, float and handle including PVC flush pipe 32mm dia bend and a pair of mild steel iron brackets of suitable size including making necessary connection to water supply pip line, complete all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortor bedding (but not backing removing serviceable to store and rubbish off the premises complete all as specified and directed.
M&L for Glazed ceramic colour tiles in vertical surface of size 350 x250x 7 mm or 450x 350x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick cement plaster in CM 1:4 all as specified and directed.
M&L for Non Skid ceramic tiles joint free 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.18 sq m but not exceeding 0.38 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed or bedding layer in CM 1:6, all as specified and directed.
All as per item 194 above but in skirting/ dado all as specified and directed.
S&F in repair stainless steel kitchen plate rack made out of stainless steel sheets 1mm thick overall size 600mm x 750mm x 250mm including complete
M & L for green marble 18mm thick (table rubbed and polished) in cooking platform/floor, trades & risers, skirting etc machine cut laid over 20mm thick screed bed or beding layer in CM 1:4 and jointed and pointed with grey cement mixed with colour pigment to match the shade of the slab including rubbing and polishing and making edges chamfered and demolition of old stone slab of any description, complete all as specified and directed.
M&L for Machine cut kota stone as in trades and risers (in one piece) 18-20mm thick over 15mm thick cement screed base in CM 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing incl demolition of old stone slab of any description complete all as spd & directed.
Dismantling of PVC water storage tanks exc 500 ltrs & n.exc 1000 ltrs capacity and removing from site all as specified.
S&F rotational moulded polythylene water storage tanks 500 Ltrs capacity, white coloured, triple layered (cylindrical vertical with closed top) hoisted including 20mm GI water tank nipple connection, ball valve high pressure of PTMT with epoxy coated alumminium rod high density plastic ball screwed for iron 20mm dia iron pipe and fixed in position complete all as spd & directed.
M & L for providing and injecting chemical emulsion for post construction antitermite treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the substructure to a depth of 300 mm including excavating channel along the wall and rodding etc. complete.
M & L for treating of soil under existing floors using emulsion @ one litre per hole, 300 mm apart including drilling and plugging 12 mm dia. Holes with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floors
M & L for 18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified & directed.
S&F 100mm size stainless steel handle, bow shaped as per sample for cupboards complete all as specified and directed.
S&F 75mm thick heavy duty stainless steel butt hinges for cup boards complete all as specified and directed. Make : Hettich or equivalent.
S & F 50mm drawer lock (as approved) gde-I complete all as specified and directed. (Make : Godrej/Harrison or equivalent.
Excavation in trenches in soft/loose soil not exc 1.5m wide and not exc 1.5m deep complete all as specified.
Returning filling in, including spreading leveling, watering and well ramming in layers n. exc. 15 cm in soft/loose soil, complete all as specified and directed.
Removing excavated material and disposed off from MoD land complete all as directed
Impregnating cream for injection into masonry or concrete wall 230mm thick against capilary rising humidity. Rising bar super srong (Product No. 201) of chowgale building chemicals or equivalent piilite/Drfixit/sika/fosroc complete all as specified and directed. Method of Application Methodology (a) The surface must be sound, absorbent, clean, free of dust, oil, paint, curing agents, loose cement or lime plaster & concrete, debris, or any separation layers. (b) The plaster must be knocked off at least 50cm beyond the visibly penetrated area. (c) Damaged mortar joints are to be scraped out to a depth of approximately 2-3cm. All sharp edges/joints needs to be levelled, loose concrete to be removed. (d) Drill boreholes at ground level horizontally. The boreholes are drilled horizontal into the masonry. (e) The holes should be drilled until a depth of approx 5cm (for a 6cm thick wall) before the end of the all is reached. The boreholes should have a diameter of 12mm upto a maximum of 15mm and should be spaced approx 100 to 120mm apart and the vertical offset is 6cm max. (f) Before inserting Rising Bar Super Strong or equivalent the boreholes must be cleaned from boring dust by using air pressure, it is not necesary to pre-wet the borehole. (g) For applying of Rising Bar Super Strong or equivalent the dosing system inserted as far as possible into the borehole. While dosing the product uniformly, the injection nozzle is pulled out leading to a completely filled borehole. (h) Treatment of highly absorbent masonry might require repeated filling of the borehole. Depending upon extent of damage, Rising Bar Super Strong or equivalent can be re-injected into the same hole after 24hrs. Depending on abosrbency, application or masony thickness 0.1 to 0.15 litre/m with 10cm wall thickness.
S & F stainless steel double layer shelf with towel rod, multypupose wall mount bath shelf fixed with SS screws (as approved by GE) complete all as specified and directed.
PMM : REPAIRS (FOR PATCH REPAIRS)
a)25 mm average thickness ( in 2 layers)
b) 50 mm average thickness ( in 3 layers )
PMM repairs at (a) and (b) above shall be done as per following methodology (From sub items (i) to (vi) below)
i) Chipping of plaster and unsound/weak concrete material till reinforcement bars are exposed, which enabls their rust removal vides item ii) below, from slabs, beams, and columns etc. with standard power driven percussion type or pneumatic chisel of standard make as directed by Engineer-incharge including tapering all edges, making square shoulders of cavities etc complete and disposal of debris up for all lifts and leads .
ii) ) Rust removal by Providing and applying Fosroc Reebaklens RR or equivalnet from SIKA/ BASF, a combination of acid based material, corrosion inhibitors and dispersing agents rust remover, for removal of all rust/ scales/corrosion from reinforcement bars before microconcreting or patch repair,It Shall be applied with brush for complete wetting of rusted metal surface at coverage of 2- 2.5 Sqm/ltr. & allow it to react for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal /steel for about 5-7 days. Before applying any protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth.
iii) Anticorrosive treatment by Providing and applying Nitozinc Primer an epoxy based zinc rich anti corrosive primer having adhesive bond strength ≥ 1.5 MPa as per ASTM D4541, & shall comply to per ASTM B-117 to be applied on well cleaned, fully exposed and all loose scale , rust free rust free surface obtained by grit blasting or suitable means , to be done with coverage @4.5sqm/litres to achieve a minimum thickness of 40microns DFT or as per direction of Engineer-In charge.
iv) Epoxy bonding for Old concrete & New concrete by providing and applying bond coat on the prepared surface with two component epoxy based bonding coat Nitobond EP of Fosroc make or equivalent, having specific gravity 1.15 to 1.2 gm/cc, Compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, Flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, Tensile strength (BS 6319 Pt.7)- 20 Mpa at 7 days, Shear Strength (BS 6319 Pt.4)- 10 Mpa at 7 days, having an over lay time of 6 hrs and 30 ̊C. Bonding agent shall have coverage not less than 2.5sqm/litres Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat. Item rate is inclusive of materials all labour, tools and tackles. complete as per specification and as directed by Engg.-in-charge.
v) PMM by providing and laying single component, polymer modified, fibre reinforced cementitious repair mortar, Rendroc SP40 or equivalent from SIKA/BASF over the tacky bond coat, that achieves Compressive strength (BS 1881 Pt.116) > 20 MPa at 1 day , > 45 Mpa at 28 days, Tensile Strength > 2.5MPa, Flexural Strength > 7Mpa at 28 days, Finishing the same with trowel carefully compacting the same around the rebars and finishing to bring it in line with existing concrete surface on the beams, slabs, piles etc., , complete in all aspect as per manufactur's methodology. Rates include cost of all labour, materials, Tools and Plants,propping, scaffolding, shuettering, safety arrangment, quality control, testing complete as per specifications and direction of engineer in charge.
vi) Item rates of PMM 25 mm and PMM 50 mm (against items (a) and (b) respectively ) are inclusive of all materials, labour, tools and plants, propping, scaffolding, safety, arrangement, quality control, testing and all items of works from i) to v) above quality control, testing etc. complete in all respect, as per specifications and as directed by Engineer.-in-charge. Work shall be complete only after proper wet curing has been done by contractor and surface has been evaluated for satisfactory quality by sounding/tapping with a blunt metal instrument, and testing of PMM cubes filled up and cured by contractor during the application of PMM (75mm size cube crushing strength at the end of 28- day to be not less than 45 N/sqmm) in addition to NDT Testing as per under item of "Testing of works"
Drilling suitable holes in reinforced cement concrete with power driven drill machine to a minimum depth of 10D(D-Dia of Bar in mm) in RCC beams, lintels, columns and slabs to introduce new steel bars including fixing the steel bars in position using Lokfix E75 or equivalnet from SIKA/ BASF a two-component epoxy anchoring material, supplied in 3:1 ratio having compressive Strength (EN196) >110 MPa, Flexural Strength (EN196) >40MPa, E Modulus (EN196) 10,800 MPa. or of equivalent make but excluding the cost of reinforcement, all complete as per direction of Engineer-In- Charge.
a) 8mm Shear Connectors
b) Anchoring bars for 10mm Dia
c) Anchoring bars for 12mm Dia
d) Anchoring bars for 16mm Dia
Providing and applying a non shrink, polymer modified cementitious micro-concrete Rendroc RG or equivalent from SIKA/BASF having compressive strength (BS 4551-80)-50 Mpa at 28 Days, Tensile strength- 2 Mpa @ 28 Days, Flexural Strength(BS 4551-80)-5 Mpa at 28 Days. product shall have A1 Class Fire Rating confirming to EN1504 cl 5.5, Thermal conductivity of 1.5W/m degree C. Renderoc RG can be applied in sections upto 100mm deep. Pouring the same into the formwork using suitable arrangement or if required using pumping device for uniform flow of micro concrete. Rate is inclusive of preparatory works from item i) to item v) below, rates also includes cost of materials labour, tools and plants, cost of shuttering & scaffolding, safety arrangement quality control and testing etc. complete as per specification and as directed by Engineer.-in-charge
i) Chipping of plaster and unsound/weak concrete material till reinforcement bars are exposed, which enabls their rust removal vides item ii) below, from slabs, beams, and columns etc. with standard power driven percussion type or pneumatic chisel of standard make as directed by Engineer-incharge including tapering all edges, making square shoulders of cavities etc complete and disposal of debris up for all lifts and leads .
ii) ) Rust removal by Providing and applying Fosroc Reebaklens RR or equivalnet from SIKA/ BASF, a combination of acid based material, corrosion inhibitors and dispersing agents rust remover, for removal of all rust/ scales/corrosion from reinforcement bars before microconcreting or patch repair,It Shall be applied with brush for complete wetting of rusted metal surface at coverage of 2- 2.5 Sqm/ltr. & allow it to react for 16-24 hours. After 24 hours, a white layer will appear which will protect further corrosion of metal /steel for about 5-7 days. Before applying any protective coating, the surface should be wire brushed and thoroughly cleaned for dust with dry cloth.
iii) Anticorrosive treatment by Providing and applying Nitozinc Primer an epoxy based zinc rich anti corrosive primer having adhesive bond strength ≥ 1.5 MPa as per ASTM D4541, & shall comply to per ASTM B-117 to be applied on well cleaned, fully exposed and all loose scale , rust free rust free surface obtained by grit blasting or suitable means , to be done with coverage @4.5sqm/litres to achieve a minimum thickness of 40microns DFT or as per direction of Engineer-In charge.
iv) Epoxy bonding for Old concrete & New concrete by providing and applying bond coat on the prepared surface with two component epoxy based bonding coat Nitobond EP of Fosroc make or equivalent, having specific gravity 1.15 to 1.2 gm/cc, Compressive strength(BS 6319 Pt.2)- 50 Mpa at 7 days, Flexural strength strength(BS 6319 Pt.3)- 35 Mpa at 7 days, Tensile strength (BS 6319 Pt.7)- 20 Mpa at 7 days, Shear Strength (BS 6319 Pt.4)- 10 Mpa at 7 days, having an over lay time of 6 hrs and 30 ̊C. Bonding agent shall have coverage not less than 2.5sqm/litres Laying of reinstatement polymer modified mortar or micro concrete shall be completed within the overlay time of bonding coat. Item rate is inclusive of materials all labour, tools and tackles. complete as per specification and as directed by Engg.-in-charge.
v) Work will complete only after proper wet curing has been done and testing of Microconcrete cubes filled up and cured by contractor during column jacketing work (100 mm size cube crushing strength at the end of 28-day to be not less than 45 N/sq.mm) and NDT tests mandated under item "Testing of works"
SHOTCRETING (For through repairs of RCC elements like Slabs, Beams etc) with
a) 25 mm thick in grade M25 with cement content not les than 330 kg per cum
Shotcreting (Guniting) of R.C.C. components with approved mix mortar [with ordinary portland cement, coarse sand in proportion (1:3)] including the cost of materials, labour, Plants and equipment, centering and shuttering at edges and corner if required, propping, scaffolding and safety arrangment quality control & testing of works, the rate will also include Chipping (sub item i below) cleaning of concrete surface and reinforcement rust with sand blasting (sub item ii) below, wet curing quality control and testing etc. complete as per specifications and as directed by Engineer- in-Charge. Surface shall be evaluated by sounding /tapping with a blunt metal instrument by engineer incharge or his representative apart from cube tests for compressive strength of 25 N/sqmmand NDT tests under Item "Testing of Works"
i) Chipping of plaster and unsound/weak concrete material till reinforcement bars are exposed from slabs, beams, columns etc. with standard power driven percussion type or pneumatic chisel of standard make as directed by Engineer-incharge including tapering all edges, making square shoulders of cavities etc complete and disposal of debris up for all lifts and leads .
ii) Cleaning of concrete surface and reinforcement rust of by sand blasting with coarse sand followed by and including cleaning with oil free air blast so as to de-rust reinforcement bars as per direction of Engineer in charge.
Waterproof coating including surface preparation and laying of geotextile layer: Providing and applying waterproofing treatment to sound, moisture free concrete surface using Nitoproof 600PF manufactured by Fosroc or equivalent from SIKA/BASF by authorised applicator. Nitoproof 600 PF shall be liquid applied single component pitch free polyurethane coating capable of bridging substrate cracks upto 2 mm. It shall be applied in two coats at coverage rate of 2kg/sm to a achieve a minimum DFT of 1.3 mm. The membrane formed shall confirm to following minimum properties: 1) Elongation : >400% as per ASTM D 412 2) Tensile Strength : 2.5 N/mm2 as per ASTM D 412 3) Adhesion in-peel test : >50 N as per ASTM C- 836 4) Recovery from 350% elongation : 95% as per ASTM D 412 5) Water Vapour Transmission 2.3mm film: 0.6 g/m2/hr 6) Initial Hardness Shore A : min 60 as per ASTM D 2240. 7) Root resistant : protection by screed is required. 8) Crack bridging not less than 2mm Membrane Termination shall be done at 300 mm above FFl and and secured by providing a groove cut of 10mm x 10mm & seal it with Renderoc HSXtra of fosroc. System shall be applied in two coats on to a well cleaned and moisture free substrate using brush, squeegee, roller/suitable spray applied machine. The second coat shall be applied in perpendicular direction to the first, all complete as per the fosroc methodology. Rate shall include cost of surface preparation (sub item (i) below) and providing and laying of Geotextile layer (sub item (ii) below), all materials, labour, Tools & Plants, quality tests (Ponding etc.) complete in all respects as per specifications and as per direction of Engineer in charge. In addition contractor has to submit a minimum of 10 years' gaurantee against lealage through water proofed Terrace.
Surface Preparation: RCC Surfaces must be clean, even and sound concrete. Remove all oil, existing broken/damaged coving, dirt, laitance, protrusions(by light grinding) and other contaminants manually to attain a fairly smooth surface. Any undulations, pot holes, cracks shall be opened & treated with polymer modified mortar made by mixing Nitobond SBR or equivalent from SIKA/BASF @10% by weight of cement in Cement: Sand mix of ratio 1:3. This includes making of coving at all wall floor corners using PMM, complete in all respect as per the direction of Engineer incharge. The entire repair shall be allowed to cure before proceeding with any waterproofing treatment. Cement and sand shall be arranged by contractor himself.
(ii) Geotextile layer : Providing and installing 180 GSM non-woven geotextile membrane over the finish waterproofing treatment prior to protection screed as per specifications and direction of Engineer in charge
Pipe Penetration Treatment: Providing and applying Nitobond EP or equivalent from SIKA/BASF an epoxy bonding agent over the PVC and internal side of of concrete after rubbing it with emery paper/sandppaper and fixing hydroswellable waterbar supercast SW in the centre of depth of slab. Later Filling the pipe gap with Conbextra GP2 leaving 20 mm * 20mm gap from the top all over the periphery, with all shuttering already in place. Later the gap shall be filled with Nitomortar S, two component epoxy mortar only after complete hydration of the prefilled grout, before treating the surface with Waterproofing layer. (Upto 100mm Dia)
M&L for laying PCC of M-15 grade( min 50 mm thick finishing at the drain pipe )mixed with approved water proofing compound like Conplast WL Xtra (Integral waterproofing compound confirming to IS 2645). This includes making of coving at the wall-floor corners using same concrete.Average 75mm thk.
PLASTERING:
Repairs to plaster of thickness 6 mm to 20 mm,upto floor 5 including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in- Charge -with cement mortar.
a) 6 t0 10 mm cement plaster of ( 1:4) added with Polymer SBR @2% of cement
b) 15mm cement plaster of ( 1:5) added with Polymer SBR @2% of cement (c) Rate quoted against this item vide sub items (a) and (b) above shall include all materials, labour, tools and plants, scaffolding, safety arrangemetn and preparation of surface as mentioned vides (a) and (b) above complete in alln respects as per specifications and directions of Engineer-in-Charge.
Supplying and providing of FRP Chhajjas of 450mm width suitable for various opening incl grounting in existing wall and fitting with suitable screws and fixtures upto 5th floor level incl all labour material tools and plants scaffolding safety arrangements quality checks complete in all respect all as specified & directed
Waterpoofing of Wet area : Wet areas/ Sunken area/Utility area/Balcony area waterproofing using Fosroc Brushbond RFX or equivalent from SIKA/BASF
Waterproof Coating: Providing and applying two coats of Brushbond RFX, high performance, elastomeric, acrylic polymer modified cementitious coating having a mixed density of 1.6 kg/cc manufactured by fosroc chemicals india pvt. ltd or equivalent from SIKA/BASF by authorized applicators. Minimum recommended coverage is 0.5m2/per kg /2 coats to achieve a min DFT of 1mm. waterproof coating shall confirm to ASTM C-836, ASTM D 4541 & ASTM D 4060. Brushbond RFX coating shall exhibit below properties: 1. Abrason resistance ASTM-D4060 : 0.85 , 2. Tensile strength as per ASTM D412 is 1N/mm2 3. Adhesion to concrete is greater than 1N/mm2 4.static crack accommodation ASTM-C836. min 1mm System include supply and application, all complete as per the fosroc methodology. Item shall include making of coving at all the wall-floor corners using 1:4 Cement Sand mortar admixed with Nitobond SBR latex, & termination at 300mm above FFL by cutting of 10mm X 10mm chase and later filling with Nitobond SBR Latex admixed PMM. Size of coving may vary as per site conditions. Payment shall be made as per actual area of measurement. Rates are inclusive of cost of preparatory works vides item (i) and item (ii) below. Rates includes all materials, labour, tools, plents, safety arrangement, quality control and testing etc. complete as per specifications and direction of Engineer in charge.
(i) Coving: Opening up the corners of Wall-floor corners to a minimum 10mm *10mm groove, later cleaning the same using water, later filling the groove using 1:3 Cement Sand Mortar Admixed with Nitobond SBR Latex @ dosage of 10% by wt. of cement, followed by making of concave coving of size 40mm *40mm, including finishing, curing, all complete as per manufacturer's methodology.
(ii) Construction Joint & Crack Treatment: Chase open construction joints in v shape of 15mm x 15mm using suitable means, later cleaning the same using water jet and applying a bond coat of Nitobond SBR Latex orequivalent from SIKA/BASF mixed with cement and water in a ratio of 1:1:3(Water : Polymer : Cement), followed by filling of Nitobond SBR Latex admixed PMM in the groove, including, filling, finishing, curing all complete as per the direction of Engineer In-Charge. In case of structural cracks, injection grouting shall be carried out either using Cementitious Grout or Low viscous epoxy grout, depending upon the kind of cracks. In case of poor/weak construction joints, injection grouting at the CJ's should be carried out depending upon the joint characterstics and shall be paid separately.
Bore Packing : Providing and applying Nitobond EP an epoxy bonding agent over the PVC and internal side of of concrete after rubbing it with emery paper/sandppaper and fixing hydroswellable waterbar supercast SW20 in the centre of depth of slab. Later Filling the pipe gap with Conbextra GP2 from the top all over the periphery, with all shuttering already in place, (Upto 100mm Dia).
Protection Plaster: Providing and applying Cement plaster/screed of proportion 1:4 admixed with integral waterproofing admixture Conplast WL Xtra or equivalent from SIKA/BASF, a Corrosion resistant admixture as per ASTM G1, JISZ 1535 mixing @ 200ml/bag of cement. This shall include all champering , rounding off of corners, protusion and shall include shuttering cost or as per Engineer in-charge specification. Cement and sand will be in client scope.
a) 12mm thk 1:4 Cement: Sand Plaster for Verticals Areas
b) Min 40mm thk 1:4 Cement: Sand Screed for Horizontal Areas
Testing of Works: Apart from supervision and inspectionof materials the Works under this work order (Shekhawati Blocks) would be tested by NDT methods; for this purpose 10 Rebound Hammer Tests and 10 UPV tests Tests would be conducted on PMM, Microconcrete and Shotcrete (Gunniting) works per block (on an average basis) would be conducted as per specifications of materials and applications as also the specifications of NDT tests and as directed by Engineer in charge. The cost of these tests shall be born by contactor and this cost is supposed to be built up in items of work above, no separate payment will be payable on this account.
Description of Work / Item(s)
Amount
Taking down carefully copper/aluminium any type of point wiring (light/fan/socket /power) complete (fittings such as switches, ceiling roses, holders, sockets, light fittings) and removal from site and making good the disturbed surfaces of wall/floors/ceiling etc) complete all as specfied & directed.
M&L for concealed point wiring with PVC FRLS insulated multi stranded unsheathed cable 1.5 sqmm size with stranded copper conductor, 1100 volts grade conforming to IS-: 694 drawn in and including concealed PVC rigid conduits 20 mm dia incl cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed with concealed sunk in pressed steel terminal boxes of 1.6mm thick factory made and painted with stove enameled black paint covered with 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washers including single core stranded copper conductor 1.5 sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified for the following :-
(a) One light/fan/bell point controlled by one way switch 5 amps.
(b) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(c) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board.
(d) One two way point controlled by 2 way switch 5 amps.
Material and Labour for concealed point wiring with PVC insulated unsheathed multistranded FRLS copper conductor in PVC conduit with cable 2.5 Sqmm size 1100 volts grade conforming to IS:694 in new modular metal flush box of 1.6 mm thick including one coat of syenthetic enamelled black paint with new modular white cover plate with frame of suitable size of required colour fixed with brass screws and cup washers including single core stranded FRLS copper conductor 1.5Sqmm PVC insulated cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same concealed conduit for One 3 Pin socket 15A Indepentent board
S&F of switch piano type 5 amps single pole one way complete all as specified and directed.
S&F of switch piano type 15 amps single pole one way complete all as specified and directed.
S&F of socket outlet multipurpose 2/3 pin 5 amps flush button type complete all as specified and directed.
S&F of socket outlet multipurpose 2 in 1, 5 and 15 Amps complete all as specified and directed.
S&F of ceiling fan regulator step type for 1200/1400 mm sweep ceiling fan including connections complete all as specified and directed.
S&F of 2 way switch flush type SP two way 6 amp complete all as specified and directed.
S&F bell push switch complete all as specified and directed.
S&F of electric bell Ding-Dong AC 230 Volt SP with brass screws and cup washers all as specified and directed.
M & L for Decorative walll light CITY-3 fixture made up of Polycarbonate, Spiral B-22 including 7 Watt LED Bulb complete Watts.
S & F of Lamp holder,PVC /Polycarbonete type with back plate suitable for batten fittings with connections complete all as specified and directed
S&F of LED bulb of 9 watt complete all as specified and directed.
Supply, laying and drawing in and including 20 mm dia concealed PVC rigid conduits including cutting of chases for laying conduit making good the surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforing to IS : 694 of 1990 complete including connection all as specified and directed.
Taking down ceiling fan, sealing cable end, dismantling blades and removing fan and blades to store complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
S & F LED light fitting 1X10W bulk head luminaires includin LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F of factory made epoxy polyester powder coated distribution board SP & N 8 way fabricated from minimum 1.6 mm thick CRCA sheet with metal double door (IP-43 protection ) fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, eath bar and cable ties for cable management, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and conforming to IS: 8623 alongwith cable end box for above DB all as specified and directed. NOTE (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F of factory made epoxy polyester powder coated distribution board TP & N 6 way (VTPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 125, 4 pole MCCB and ELM as incommer and 16 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs all as specified. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F of factory made epoxy polyester powder coated distribution board TP & N 4 way (VTPN MCCB DB) with metal double door (IP-54 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed on wall and suitable for universal mounting and including 200 Amps copper bus bar, Neutral bar, standard DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with provn for DPX 160, 4 pole MCCB and ELM as incommer and 12 SP MCBs outgoings complete all as specified and conforming to IS: 8623 along with cable end box for above DB including taking down old DBs all as specified. NOTE :- (a) MCBs shall be measured and paid separately. (b) All cables terminating into MCBs shall be connected by using suitable copper lugs/thimbles/sleeves and its cost shall be deemed to be included under respective item of Sch.
S&F in of MCCB 125 Amp 4 pole 16 KA at 415 V with fixed thermal megnatic release complete all as specified directed.
S&F of single pole MCB 6 to 32 Amps, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity complete conforming to IS 8828 of 1996 including taking down old MCB's complete all as specified and directed.
S&F of SP pole MCB 40 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘B’ curve, 10 KA breaking capacity, complete all as specified and directed.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.complete all as specified and directed.
S&F Exhaust fan metallic body single 230/240V of 250 mm sweep including cutting of holes in a round shape and including fixing the exhaust fan complete all as specified and directed.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed.
S&F ceiling rose 3 phase/PVC/polycarbonate isolated body complete all as specified and directed.
S&F SPN MCB 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed.
Supply & fix AC single phase static energy meter of accuracy class 1.0, 240 V, 50 Hz with Backlit LCD display of rating 10- 60 A, (measures and displays KWH ,V, Current I, KW, pf last month history of KWH, MD in KW) with special features like TOD, temper logging, optical communication port display in absence of power with transparent hinge type box complete all asspecified and directed.
Supply and Fix HOT press moulded SMC Meter box of inside dimensions 250x150x155 mm with hinged doors and all accessories required for fixing 01 nos single phase digital electronic meter complete all as specified and directed.
S&F single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
S&F of electric storage water heater of capacity 25 ltr with vitreous enamel coating with all accessories and fittings arrangements and testing after installation complete all as specified and directed. Note: Rates are inclusive of connection from existing pipe line to electric storage water heater.
S&F PVC connection with brass nipple of size 15 mmx600 mm long with ISI marked suitable for hot and cold water of 25 ltrs capacity of geysers as hot and cold water connection complete all as specified and directed.
M&L far Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, burieddirectly in ground (earth pit not lessthan 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion all as specified and directed.
AMIT ASSOCIATES
M/s Matadeen Ramchandra Agarwal
Global Enterprises
LUMOS INFRA PVT LTD
AMIT ASSOCIATES
M/s Matadeen Ramchandra Agarwal
Global Enterprises
LUMOS INFRA PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .