Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC | L1 | Accepted-AOC Accepting being lowest | |
| 2 | L2₹20.6 L+₹41,127 (2.04%)Rejected-Finance | L2 | Rejected-Finance Rejected being other than lowest | |
| 3 | L3₹25.7 L+₹5.6 L (27.6%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-Finance Rejected being other than lowest | |
| 4 | L4₹27.4 L+₹7.3 L (36.0%)Rejected-Finance | L4 | Rejected-Finance Rejected being other than lowest | |
| 5 | L5₹31.9 L+₹11.7 L (58.3%)Rejected-Finance | L5 | Rejected-Finance Rejected being other than lowest |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
6 Oct 2021, 6:00 pmClosed
Maj Pramod Kumar Tripathi
Garrison Engineer (South) Ahmednagar, Military Engineer Services, Ahmednagar- 414002
Repair/Maint of internal wiring and connected works at Aurangabad under GE (S) Ahmednagar
2021_MES_473356_1
8816/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Aurangabad
Class D Cat b (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (South) Ahmednagar
₹60,000
Yes
27 Oct 2021
7 Sept 2021
8 Oct 2021
7 Sept 2021
6 Oct 2021
21 Sept 2021
7 Sept 2021 - 13 Sept 2021
Amount
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fittings such as switches, ceiling roses, pendants, regulators, sockets etc but excluding DBs, light fittings etc and making good disturbed surfaces of walls, floors etc. and matching with existing surface all as specified and as directed.
M&L for point wiring complete with 1.5 Sqmm single core, multistranded, copper conductor, fire retardant, PVC insluated and unsheathed cable 650/1100 volts grade,conforming to IS-694 1990, drawn through and including casing capping 25mm/32 mm width with all accessories as specified with modular cover plate with frame and modular metal flux boxes, blank plate for mounting fittings & fixing like switches sockets and fan regulators etc. including copper earth continuity wire for PVC insulated of size 1.5 Sqmm for one light point controlled by one way switch complete all as specifed and as directed.
All as per serial item No. 2 above but for one fan point controlled by one way switch and regulator.
All as per serial item No. 2 above but for one 3 pin socket outlet, 5 Amps on same board with other switches
All as per serial item No. 2 above but for one 3 pin socket outlet, 5 Amps on independent board but below the switch board of light points in the same vertical plane, with cables, 1.5 sq. mm size
All as per serial item No. 2 above but for one light point controled by two, two way switch
All as per serial item No. 2 above but for one bell point controlled by one bell push
All as per serial item No. 2 above but for one 3 pin socket outlet, 5 Amps on independent board.
All as per serial item No. 2 above but with 4.0 Sqmm copper conductor cable for socket outlet 15 Amps
S&F modular switch, piano type, 5 Amp, single pole, one way, flush type, white or ivory, ISI marked all as specified and as directed.
S&F modular switch, piano type, 15 Amp, single pole, one way, flush type, white or ivory, ISI marked all as specified and as directed.
S&F modular switch, piano type, 5 Amp, single pole, two way, flush type, white or ivory, ISI marked all as specified and as directed.
S&F modular bell push, piano flush type, one way, ISI marked all as specified and as directed
S&F modular socket outlet, 3 pin, 5 Amps, flush type, ISI marked all as specified and as directed
S&F modular socket outlet, 6 or 5 pin & 15 Amps, flush type, ISI marked all as specified and as directed
S&F electric door bell, 230 V, multi music type, ISI marked all as specified and as directed
S&F ceiling rose, surface bakelite, 65 x 20 mm, two to three terminals all as specified and as directed
S&F standard PVC batten/angle holder including LED bulb of 12 watts all as specified and as directed.
S&F in repairs, condesor, 2.5 mfd to 3.5 mfd all as specified and as directed
S&F modular fan regulator, electronic step type, humming free, ISI marked all as specified and as directed.
S&F in repairs, sheet metal enclosure, SPN with 2 pin and earth plug and socket complete with and including single pole, 20 Amps MCB, 240V (for AC/Geyser) all as specified and as directed.
S&F in repairs, electronic ballast, suitable up to 28 Watt LED, surface mounted light fittings, all as specified and as directed. Make- Philips/Bajaj/Havells/Cromption
S&F in repairs, LED tube rod, suitable for 36W/40W tube light fitting /fulouroscent tube light fitting all as specified and as directed. Make- Philips/Bajaj/Havells/Cromption
S&F in repairs, ultra slim LED ceiling panel light fitting, 2 x 2 feet, recessed type, 28 W, 220 Volt, AC, white, powder coated Aluminium housing, main current 0.130A, power factor 0.95, THD ≤20, colour temp.(CCT) 5700 K, CRI ≥80 & system lumens 3640 lm all as specified and as directed. Make : Havells cat No PLANO2X2PLR28WLED857S or equivalent model of make Philips /GE/ Crompton/ Luker/ Halonix/Century LED ltd.
S&F in repairs, LED tube light fitting with single LED tube 1x18 W, 230V, four feet long, energy efficient, direct surface mounted, decorative with aluminium extrusion with PC diffuser including connecting up with twin core PVC insulated copper conductor cable of suitable size all as specified and as directed. Make : Havells cat No LUMILINEPLUSBS18WLED865SPCSS or equivalent model of make Philips /GE/ Crompton/ Luker/ Halonix/Century LED ltd.
S&F in repairs, bathroom/mirror light LED tube light fitting with single LED tube 1x10 W, 230V, energy efficient, direct surface mounted, decorative with aluminium extrusion with PC diffuser including connecting up with twin core PVC insulated copper conductor cable of suitable size, all as specified and as directed. Make : Havells cat No LUMILINEPLUSBS10WLED865SPCSS or equivalent model of make Philips /GE/ Crompton/ Luker/ Halonix/Century LED ltd.
S&F in repairs, MCB DB, double door panel, prewired with inbuilt MCCB 100A, TPN, 415 Volts, 25 KA for incoming and 6 Nos MCB SPN 63A, 10 KA MCBs for out all as specified and as directed.
S&F in repairs, sheet metal enclosure, single pole & neutral for 240 volts, 4 way with 200 Amp rated bus bar, flush /surface mounting, double door complete all as specified and as directed.
S&F in repairs, sheet metal enclosure, single pole & neutral for 240 volts, 8 way with 200 Amp rated bus bar, flush /surface mounting, double door complete all as specified and as directed.
S&F in repairs, sheet metal enclosure, single pole & neutral for 240 volts, 12 way with 200 Amp rated bus bar, flush /surface mounting, double door complete all as specified and as directed.
M&L for sub main wiring with 2 runs of 4 sqmm, single core, PVC insulated & unsheathed cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size casing / caping (ISI marked) with all accessories such as Tees, Elbows, junction box etc as requied alongwith one run of 2.5 sqmm single core PVC insulated & unsheathed copper conductor as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of casing/caping, complete all as specified and as directed. Note : Two runs of 4 Sqmm cable, one run of 2.5 Sqmm cable and one run of PVC casing/caping will be measured as one Rm unit.
M&L for sub main wiring with 2 runs of 6 Sqmm, single core, PVC insulated & unsheathed cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size casing / caping (ISI marked) with all accessories such as Tees, Elbows, junction box etc as requied alongwith one run of 4 Sqmm single core PVC insulated & unsheathed copper conductor as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of casing/caping, complete all as specified and as directed. Note : Two runs of 6 Sqmm cable, one run of 4 Sqmm cable and one run of PVC casing/caping will be measured as one Rm unit.
M&L for sub main wiring with 2 runs of 10 Sqmm, single core, PVC insulated & unsheathed cable, conforming to IS-694, 1100 volts with copper conductor, multi stranded, drawn in and including suitable size casing / caping (ISI marked) with all accessories such as Tees, Elbows, junction box etc as requied alongwith one run of 6 Sqmm single core PVC insulated & unsheathed copper conductor as continuous earth wire dolly and connecting to existing main switch board / distribution board of each building / qtr as ordered and testing on completion including taking down old submain wiring and any type of casing/caping, complete all as specified and as directed. Note : Two runs of 10 Sqmm cable, one run of 6 Sqmm cable and one run of PVC casing/caping will be measured as one Rm unit.
S&F in repairs, MCBs, SP 6 to 32 Amps, 10 KA, IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and as directed.
S&F in repairs, MCB, SPN 40 to 63 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and directed.
S&F in repairs, MCB, TPN 63 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and directed.
S&F in repairs, MCB, TPN 100 Amps, 10 KA, 'C' curve IS/IEC 60898-1 2002 marked fixing in DBs complete all as specified and directed.
S&F in repairs, RCBOs, 40A for earth leakage, overload and short circuit protection double pole 100mA all as specified and as directed.
S&F tamper proof electronic energy meter, digital LED display, single phase, 220 Volts, suitable for 40 Amp current rating capacity with FRP box & locking arrangement including taking down old energy meter and depositing in MES storeyard all as specified and as directed.
S&F tamper proof electronic energy meter, digital LED display, single phase, 220 Volts, suitable for 60 Amp current rating capacity with FRP box & locking arrangement including taking down old energy meter and depositing in MES storeyard all as specified and as directed.
S&F tamper proof electronic energy meter, digital LED display, three phase, 415 Volts, suitable for 0-100 Amp current rating capacity with suitable raing CTs and FRP box with locking arrangement including taking down old energy meter and depositing in MES storeyard all as specified and as directed.
Taking down electirc water heater (geyser) of any type/capactiy for repairs, dismantling the accessories carefully after disconnecting the water/electirc connection and transporting to workshop(if required) for repairs and refixing the same in original position after repairs and connecting up the water/electric connections including testing complete all as specified and as directed. Note : Replacement of unserviceable parts shall be measured and paid seperately.
S&F in repairs, heating element, triangular or square type, 1500watts, 230 volts, suitable for geyser and as per approved sample all as specified and as directed.
S&F in repairs, heating element, triangular or square type, 2000watts, 230 volts, suitable for geyser and as per approved sample all as specified and as directed.
S&F in repairs, thermostat, auto cut with thermal setting upto 80 degree centigrade, 230 Volts, suitable for existing geysor of various capacities all as specified and as directed.
S&F in repairs, heating element triangular/ square headed with inbuilt thermocut switch/ thermostat of 1.5/2.0 KW, suitable for 25/50 litre capacity geyser existing at site all as specified and as directed.
S&F in repairs, inner copper, water storage tank of 25 ltr capacity geyser existing at site all as specified and as directed.
S&F in repairs, psyphon assembly suitable for 25/50 ltr capacity geyser existing at site all as specified and as directed.
S&F in repairs, aperture plate assembly complete suitable for 25/50 Ltrs capacity geyers existing at site all as specified and as directed.
S&F in repairs, 15mm bore dia, non return valve, cast copper alloy suitable for geyser all as specified and as directed.
S&F in repairs, 15mm bore dia, pressure release valve, cast copper alloy suitable for geyser all as specified and as directed.
S&F glass wool in geyser of 25/50 litre capacity all as specified and as directed.
S&F indicator, pamp red/green for geyser all as specified and as directed.
S&F drain plug for geyser all as specified and as directed.
S&F in repairs, 15mm bore dia, stop cock, cast copper alloy, chromium plated, screwed for iron pipe and fixed all as specified and as directed.
S&F 16 mm outer dia, 3-layer PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc including taking down old pipes all as specified & as directed.
S&F in repairs, heat resistant, PVC, flexible connection pipe, 450 mm long, suitable for 15 mm dia pipe with brass creamed nipple and nuts, heavy duty pressure grade 6 Kg/cm2 all as specified and as directed.
M&L for preparation of surface and spray painting to geysers of any type/capacity from out side with one under coat and one finishing coat of synthetic enamel paint, white in colour and marking MES No. with black colour as specified and as directed.
Taking out the old thermostat/heating element and refixing the same after descaling/ cleaning and making electrical connection and calibrating/adjusting to a temperature rating as per manufacturer recommendation all as specified and as directed.
S&F wall mounting fan, 450 mm sweep with all accessories complete & testing at site including taking down old wall mounted ceiling fan and depositing in MES storeyard all as all as specified and as directed.
S&F PVC flexible copper conductor wire 1.5 sqmm all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode, 60cm x 60cm x 6.3 mm thick, burried directly in ground(earth pit not less than 2.25metre deep below normal ground level) with top edge of earth plate not less than 1.5 metre below normal ground level, connected to and including galvanised earth lead wire of 4 mm dia from earth pit to each qtr DB by means of nuts & bolts, check nuts and washers of galvanised including PCC pit of 1:2:4, type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, mild steel angle iron 25 x 25 x 3mm in frame, excavation and earth work in any type of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate no 3 of MES sch 2009 (Part I), including taking down old earthing connected main switch board all as specified and testing on completion.
SONU ENTERPRISES
Shri Sai Enterprises
Paras Electricals
M/s S.R lahoti
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .