Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 LAccepted-AOC 3 39 TEACHERS COLONY LALGUDI TRICHY 621 601 | LALGUDI | TIRUCHIRAPPALLI | TAMIL NADU | 621601 | ₹18.1 L | L1 | Accepted-AOC L1 Tenderer |
| 2 | L2₹19.5 LRejected-AOC | ₹19.5 L | L2 | Rejected-AOC Rejection due to L2 bidder |
| 3 | L3₹26.5 LRejected-AOC 11 B EAST VEERAPANDIYAN STREET VIRUDHACHALAM 606001 | VIRUDHACHALAM | CUDDALORE | TAMIL NADU | 606001 | ₹26.5 L | L3 | Rejected-AOC Rejection due to L3 bidder |
| Sl No | Description | Qty | Unit | Samsudeen L3 | creepers engineering contractors L1 | L.MANI&CO L2 |
|---|---|---|---|---|---|---|
| 1.00Supply of various types of steels including Cost of steel, Freight & Handling confirming to IS 2062 Gr A at site, Fabricating the steels in to specified structures as per the std.design/Drawing, Painting of Primer coat of Redoxide paint and first finishing coat of Aluminium Paint with supply of reputed make paints after proper surface preparation such as cleaning of rust scales using appropriate machinery including all Labour, machinery and Consumables and as directed by the field Engineer at the SS site. | ||||||
| 1.01110kV Structures (3 m centre to centre) | ||||||
| 1.02 | 110kV Take off/ Strung Bus structure using Double Butt pole 200x100 RSJ. | 1 | Set | 1,18,000 ₹1.2 L | 1,10,000 ₹1.1 L | 1,15,000 ₹1.1 L |
| 1.03 | 110kV AB Switch Structure | 2 | Set | 78,000 ₹1.6 L | 77,500 ₹1.6 L | 75,000 ₹1.5 L |
| 1.04 | 110kV CT or PT Structure | 2 | Set | 49,000 ₹98,000 | 47,000 ₹94,000 | 45,000 ₹90,000 |
| 1.05 | 110kV LAS Structure below Strung Bus | 1 | Set | 63,000 ₹63,000 | 58,400 ₹58,400 | 50,000 ₹50,000 |
| 1.06Non-specified structures, Extension, Alterations, and Deductions as per station requirement. | ||||||
| 1.07 | Heavy section using RSJ 200x100 mm | 1 | Ton | 1,04,000 ₹1.0 L | 75,000 ₹75,000 | 93,000 ₹93,000 |
| 1.08 | Light section (other than heavy section) | 0.5 | Ton | 1,00,004 ₹50,002 | 95,000 ₹47,500 | 1,10,000 ₹55,000 |
| 2.00Supply of various types of steels including Cost of steel, Freight & Handling confirming to IS 2062 Gr A at site, Fabricating the steels in to specified structures as per the std.design/Drawing, Painting of Primer coat of Redoxide paint with supply of reputed make paints after proper surface preparation such as cleaning of rust scales using appropriate machinery including all Labour, machinery and Consumables and as directed by the field Engineer at the SS site. | ||||||
Tender Value
Refer Docs
EMD Value
₹18,900
Closing Date
18 Feb 2026, 2:00 pmClosed
SE/GCC/TRICHY
O/o SE/GCC/Trichy, Periyamilagu parai, Trichy
Supply of Steel and labour for fabrication, erection of steel structures and erection of equipments , erection of earth mat, earth bore , station accesseries and allied works for 110KV Bay extension at existing Eachangadu 230/110KV SS
2026_EB_650522_1
Spec No GCC075 MM059 2025-26
Open Tender
Electrical Works
90 days
Eachangadu
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹18,900
Yes
26 May 2026
3 Feb 2026
19 Feb 2026
3 Feb 2026
18 Feb 2026
3 Feb 2026
Supply of various types of steels including Cost of steel, Freight & Handling confirming to IS 2062 Gr A at site, Fabricating the steels in to specified structures as per the std.design/Drawing, Painting of Primer coat of Redoxide paint and first finishing coat of Aluminium Paint with supply of reputed make paints after proper surface preparation such as cleaning of rust scales using appropriate machinery including all Labour, machinery and Consumables and as directed by the field Engineer at the SS site.
110kV Structures (3 m centre to centre)
110kV Take off/ Strung Bus structure using Double Butt pole 200x100 RSJ.
110kV AB Switch Structure
110kV CT or PT Structure
110kV LAS Structure below Strung Bus
Non-specified structures, Extension, Alterations, and Deductions as per station requirement.
Heavy section using RSJ 200x100 mm
Light section (other than heavy section)
Supply of various types of steels including Cost of steel, Freight & Handling confirming to IS 2062 Gr A at site, Fabricating the steels in to specified structures as per the std.design/Drawing, Painting of Primer coat of Redoxide paint with supply of reputed make paints after proper surface preparation such as cleaning of rust scales using appropriate machinery including all Labour, machinery and Consumables and as directed by the field Engineer at the SS site.
Other Station Structures
110kV Breaker Platform
AC Junction Box fixing frame
Labour for the Erection of the fabricated steel structures at the SS site with Supply of GI Bolts, Nuts & Washers (Spring/Flat as required) confirming to IS including Labour, machinery and Consumables as required & as directed by the field Engineer.
110kV Structures (3 m centre to centre)
110kV Take off/ Strung Bus structure using Double Butt pole 200x100 RSJ.
110kV AB Switch Structure
110kV CT or PT Structure
110kV LAS Structure below Strung Bus
Non-specified structures, Extension, Alterations, and Deductions as per station requirement.
Heavy section using RSJ 250x125mm/200x100 mm
Light section (other than heavy section)
Other Station Structures
110kV Breaker Platform
AC Junction Box fixing frame
Supply and fabrication and erection of eye bolts/ grout bolt with 20/22 mm rod confirming to IS with proper threading and 2nos MS Nuts as directed by the field Engineer
Grout Bolt
Eye Bolt
Earthings
Supply of Various types of Steel materials confirming to ISS 2062 –Gr A including, Freight, Handling, etc., at site for Earthing with Labour for Fabrication & erection for Earthing including Labour, Machinery and Consumables as Required and as directed by the Field Engineer.
Labour for excavating and refilling of earth /trench for earthmat, cable, etc., of any size/depth narrow excavation as directed by the field Engineer.
Normal clay / hard gravel soil
Providing Earth bore 140/150 mm dia using power rig or 100/125 mm dia using hand bore set including the labour, lead, lift etc., sedimentary strata of clay & sand stone shale pebbles boulders etc., for earth Pits with supply and providing of Bentonite powder (Sodium Bentonite) 5Kg /Mtr depth of the bore mixed with low resistivity earths as directed by the field Engineer (Earth to be supplied by the contractor)
Supply and providing of 450-600 mm dia, 300 mm height, 36 mm thick cement collar for identification of earth electrode location as directed by the field Engineer.
Transportation of Department materials by the Contractor from any department stores to site or as directed by the field Engineer. Damages if any will be recovered from the contractor.
Hire Charges per day for 1 No. Diesel driven lorry of 10 T capacity upto 24hrs a day normally upto 100kms
Hire charges Upto 100kms
kilometer charges in excess of 100 kms in a day additional charges per km
Rentention charges beyond 24 Hours a day
From 1Hour to 6Hours
From 6Hour to 8Hours
From 8Hour and above
Insurance coverages for transporting both fragile and Non-fragile of Equipment in contractor's Diesel driven lorry of 10T capacity from store to site or as directed by field Engineer
HANDLING: Labour for the loading/ unloading/ shifting of Department materials at stores or site by the Contractor WITHOUT using Board's crane for one operation.
Non-Fragile Materials
110kV Isolators
Cables/Conductors including cutting and rewinding
Busbars
Fragile Materials
110kV Breaker
230/110kV CT/PT/LAS/CVT/CC/WT/Others
110kV Insulators
AC/DC/C&R Panels of Non grid type, Single feeder Control/ Relay Panels of Grid type
Labour for the erection of Insulator single pole stack for supports/ Underhang including Meggering & other consumables and as directed by the field Engineer.
110kV or 66kV
Labour for the erection of Busbar including suitable Modifications of End Clamps, providing holes wherever necessary as directed by the field Engineer.
75 mm (1 length)
Labour for the Erection of Jumper/ Droppers using Moose/ Zebra/ panther Conductors including Modification of End clamps, providing holes etc wherever necessary as directed by the field Engineer.
POWER CONNECTORS: Supply & Fixing of Aluminium Power Connectors/ Clamps/ Fittings with SS Bolts and Nuts, including, frieght etc., confirming to IS as per the drawing and specification.
Switch End Clamp for Zebra
Switch End Clamp for Panther
Switch End Clamp for 75mm Bus
T clamp for Zebra to Zebra
T Clamp for 75mm Bus to Zebra
Free End clamp 75mm
75mm Corona Bell
OUTDOOR BREAKERS: Labour for the Erection of 230/110 KV Breakers complete set using Crane with proper levelling, proving holes cutting, jointing, bending of pipes wherever required and filling of SF6 gas, Providing conductor jumpers from the Breaker to CT's & Isolators, Supply & Erection of Earthing steels two Riser to Breaker Structure from Earthmat/ electrode using 65x10 MS Flat Providing Flexible tinned Copper Earthing loops to the Breaker earthing points, Supply & painting of first primer coat of redoxide and two coats of Bus green Enamel paint on to the Earth risers including cost of reputed make paints, consumable, frieght, etc., and as directed by the field engineer.
110 KV Breaker using Crane arranged by the Contractor
MEASURMENT TRANSFORMERS:Labour for the erection of 3 Nos Measurement Transformers using Crane, Supply and Erection of Earthing steels using (65x10 for 230 KV SS) 50x8 MSF & Flexible tinned Copper loops to CT/PT for equipment & Junction box earthing, structure earting, Erection of CT/PT Junction boxes, Supply and erection of Fixing steels, Painting of Primer Redoxide, Two coats of Bus Green enamel Paint on Earthing steels with supply of reputed make paints, including, frieght & all consumables as directed by the field engineer.
110 KV using crane arranged by the Contractor
Labour for erection of Measurement transformers, reactor units, using Crane arranged by the Contractor including providing holes wherever required as directed by the field Engineer.
Labour for erection of C.T/P.T junction box
Labour for the Erection of Isolators to correct alignment, including the cost of Consumables and lubricants, Meggaring, replacement of insulators if necessary etc, Supply and erection of Earthing steels to Isolator Bases, Insulators, ABS Booms, Poles, Earth Blades, operating Mechanism earthing etc., using (65x10 MSF for 230kV SS) 50x8 MSF, Supply and Erection of 25 x 3mm² Flexible tinned copper to the centre Rotating Insulators, Mechanism Box etc, Supply and Applying of one coat of Primer Redoxide paint and Two coats of Bus Green Enamel Paint on earthing material including Freight, consumables etc.,.as directed by the field Engineer.
110kV Isolators With Earth - hand Operated
110kV Isolators W/O Earth - hand Operated
Supply of MOM/BOM for 230/110KV Isolator with all accessories
Bottom operated Mechanism box - 110 V DC
Motor operated Mechanism box - 110 V DC
LAS:Labour for erection of LAS station type with surge monitor/ accessories etc., (3 Nos single pole stack) including Supply and erection of Earthing steels, (connecting to earth electrode & mat) Supply and Painting of Primer Paints and Two coats of Enamel Paints of reputed make, including frieght, consumables etc., as directed by the filed Engineer.
110 KV LAS with surge monitors
CONTROL ROOM MATERIALS:Labour for the Erection of Control Panels includings consumables as directed by the field engineer.
Simplex type/AC/DC/C&R Panel of Non-Grid type, Battery Chargers, Single feeder Control/ Relay Panels of Grid type (P&C)
Supply and Erection of 5m Grouting type lamp post of B class MS pipe (3 inch dia for 3mtrs & 2.5inch dia for 2mtrs) including single/double fitting (Straight or 'V' type) fixing arrangements, 1 inch dia B class pipe arms, yard light box fixing flat and one coat of redoxide and one coat of aluminium paint.
Supply and Erection of reputed make street light fitting with 1x(70-75)W or 2x(35-40)W, 240V CGL/ PHILIPS make LED Light.
Supply of Erection of yard light fuse unit mounting box of size 200x200x150mm (BxHxD) out of 18 SWG (1.22mm) M.S Sheet including primer paint as per Drawing including the Supply, Fabrication and Erection of Box fixing Flat using 50x8MSF, Two coat of enamel paints, provided with 16/20A rewirable Porcelain Fuse carrier unit, 16 A Bakelite connenectors including its cost materials, consumables, freight, etc and as directed by the fiels Engineer on site requirements. (The box shall be vermin proof, shall be provided with sturdy hinges, with provision for cable entry and locking arrangements).
PAINTING:Supply and Labour for the Second Finish Coat of Aluminium paint on standard Steel Structures including cost of Paints of reputed make, Consumables etc., as directed by the field Engineer.
110kV Structures (3 m centre to centre)
110kV Take off/ Strung Bus structure using Double Butt pole 200x100 RSJ.
110kV AB Switch Structure
110kV CT or PT Structure
110kV LAS Structure below Bus Bar
Labour charges for two coats of enamel painting in substation structures, steels etc., including the cost of reputed make paints and other consumables as directed by the field Engineer.
Other Station Structures
110kV Breaker Platform
AC Junction Box fixing frame
200 x 100 RSJ Pole Bottom (height 0.45 to 0.5 m )
Yard Light Pole Bottom
Supply & Labour charges for two coats of enamel painting in any substation structures, steels, etc and wherever required including the cost of reputed make paints and other consumables as directed by the field Engineer.
Labour charges for writing details in any finished surface/board including cost of enamel paints and other consumables as directed by the field Engineer.
Labour for erection of cable in duct/ trench/ clamping on structures - neat laying in the ducts with identification Aluminium tags in all duct corners for easy identification of cables including fabrication of clamps and fixing at uniform intervals as directed by the field Engineer
Up to 8 Core
Above 8 Core
Supply and Erection of Rubber mat of size 2000 × 1000 × 10 mm as directed by the field Engineer.
Providing PVC down fall pipe using 110mm dia 4Kg/sqcm, PVC pipe and PVC clamp line supreme ec, including fixing PVC washer type door bend & shoe, in correct position and connecting from the roof slab including cost of all materials, labour, transport lead, lift, etc., complete, including PVC accessories and washers as required and as directed by the field Engineer.
Supply and glanding of ISI mark cable gland of suitable size of reputed make including removing of insulation of cables and providing suitable holes as required and as directed by the field Engineer.
Supply and termination of cable core end dressed neatly including the cost of cable socket (lug) ferrules, sleeves, tags, ties, stropes, etc., as directed by the field Engineer. (No.of core ends in unit of 1000).
Supply and erection of Vinyl Sticker cutting/ Printing on Vinyl Sticker/ Foam board to be used for main equipment, slogan, name board & any other purpose of required sizes as directed by the field Engineer.
Supply and erection of "B" class G.I.pipe for extension of tandem/ down pipe for A.B.Switches and for any other work required as directed by the field Engineer.
40 mm Dia
50 mm Dia
Supply and provision of 12/25x3mm flexible braided tinned copper / tinned copper flats as required and as directed by the field Engineer.
Supply & Crimping of Copper Lugs of Suitable sizes as required and as directed by the field Engineer.
Supply and fixing of MCB of Havells/Schneider/ MDS/ Reputed make with ISI mark wherever required as directed by the field Engineer.
32 AMPS - 3 phase, 4 pole
16 AMPS - single phase, single pole
Supply and fixing of Terminal blocks of reputed make such as Elmex/WAGO/Connectwell/Phoenix as directed by the field Engineer.
Regular type (Non Disconnecting type)
Disconnecting type (Link type)
Supply and provision of M8, M10, M12 and M16 (full /Half thread) G.I.bolt and nuts of various sizes including plate/ spring washers as required and as directed by the field Engineer.
Supply and fixing of godrej 6 lever long shackle navtol lock with triplicate keys for A.B.Switches and for any other purpose including the cost of ring and key token as directed by the field Engineer.
SGST & CGST /IGST (If applicable quote the value, if not enter '0')
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.90 MB
BOQ_779971.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid