| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹46.0 LAccepted-AOC 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹49.6 L+₹2.8 L (5.96%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹50.2 L+₹3.4 L (7.20%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹50.5 L+₹3.6 L (7.79%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹50.8 L+₹4.0 L (8.61%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
Refer Docs
EMD Value
₹87,468
Closing Date
28 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) BHISIANA
GE (AF) BHISIANA PIN - 151201
PROVISION OF CERTAIN TOILETS AND ADDN/ ALTRN TO EXISTING TOILETS AT VARIOUS LOCATIONS AT AF STN BHISIANA
2024_MES_672282_1
GE/BHI/CAP-08/2024-25
Open Tender
Civil Works
Item Rate
183 days
GE (AF) BHISIANA
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
Yes
GE (AF) BHISIANA
₹87,468
Yes
7 Nov 2024
5 Sept 2024
1 Oct 2024
5 Sept 2024
28 Sept 2024
21 Sept 2024
5 Sept 2024 - 14 Sept 2024
Amount
Excavation trenches n.exc 1.50M deep and n.exc 1.50 M depth, for foundation, etc or for shafts well, and & getting out in soft/loose soil, complete all as specified and directed by Engineer in Charge.
Excavation trenches exc 1.50M deep each additional 1.5m or part thereof in depth beyond the first 1.5 m and getting out soft/loose soil, complete all as specified and directed by Engineer in Charge.
M&L hardcore of broken stones or boulders of gauge n.exc 63mm deposited,spread & levelled in layers 10cm thick, watered & rammed to a true surfaces, complete all as specified and directed by Engineer in Charge.
M&L for PCC 1:3:6 type C2 ( using 40 mm graded aggregate) as in foundations, filling and mass concrete, complete all as specified and directed by Engineer in Charge.
M&L RCC M-30 (Design Mix) using 20mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete, complete all as specified and directed by Engineer in Charge.
M&L RCC M-30 (Design Mix), using 20mm graded stone aggregate as in Columns, pillars, piers, posts and struts, complete all as specified and directed by Engineer in Charge.
M&L RCC M-30 (Design Mix), using 20mm graded stone aggregate as in beams, cantilevers, lintel beam,lintels over 1.5 m span, complete all as specified and directed by Engineer in Charge.
M&L RCC M-30 (Design Mix) using 20mm graded stone aggregate as in slabs supported on walls, beams and columns , in floors, roofs, landings, balconies, complete all as specified and directed by Engineer in Charge.
M&L RCC M-30 (Design Mix) using 20mm graded stone aggregate as in Chajjas complete all as specified and directed by Engineer in Charge.
Formwork having fair finished surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter, complete all as specified and directed by Engineer in Charge.
Formwork having fair finished surface to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed by Engineer in Charge.
Formwork having fair finished surfaces to sides & soffits of floor or roof beams, beam haunchings, girders,bresumers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors & beams etc. complete all as specified and directed by Engineer in Charge.
Formwork having fair finished surfaces to soffits of suspended slabs, floor slabs, landings and similar work; not exceeding 200 mm thick ( Horizontal or sloping) complete all as specified and directed by Engineer in Charge.
M&L mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending , hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia, complete all as specified and directed by Engineer in Charge.
M&L mild steel TMT bars 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking,, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90 mm dia, complete all as specified and directed by Engineer in Charge.
Demolition of brick/stone massonry work built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed by Engineer in Charge.
M&L for brick work with sub class ‘B’ bricks (locally available best quality) straight or curved on plan exceeding 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer in Charge.
M&L for brick work with subclass ‘B’ bricks, (locally available best quality) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and as directed.
Demolition of cement concrete (unreinforced) exc 15 cm thickness but above ground floor, sunkan floor, complete all as specified and directed by Engineer in Charge.
M&L for 15 mm thick rendering in cement mortar (1:3) as in sunken portion walls and floor,mixed with water proofing compound 3% by weight of cement, finishing surfaces even & smooth without using extra cement complete all as specified and directed by Engineer in Charge. (Note :- water proofing compound shall be measured and paid under appropriate item of this Sch ‘A’)
Supplying only integral water proofing compound, mixed as per instruction given over it, complete all as specified and directed.as per manufactures direction
M&L for Bitumen hot blown any grade, applied hot,in two coats to concrete surfaces at the rate of 1.5 Kg per Sqm per coat, including cleaning of surfaces, complete all as specified and directed by Engineer in Charge.
Material and labour for laying 50 micron polythelene film, black in floors of sunkan, complete all as specified and directed by Engineer in Charge.
M&L for PCC (1:5:10) type E-2 using 40mm graded stone aggregate as in filling of sunken floor and mass concrete complete all as specified and directed by Engineer in Charge.
M&L for 50 mm dia GI spought pipe fixed in sunken floors by means of cutting holes in wall/ taaking down old u/s pipe,fixed and beded in cement mortor/PCC (1:2:4) and making good the disturbed portion of wall, complete all as specified and directed by Engineer in Charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer in Charge.
M&L non skid coloured ceramic tiles 7 to 8mm thick, (square/rectangular) area of each tiles exc 0.11 sqm but not exc 0.18 sqm as in floors set and jointed in cement slurry and pointed in white cement mixed with colour pigment to match existing surfaces with 15 mm thick screed bed in cement mortar (1:4) complete all as specified and directed by Engineer in Charge.
S&F for glazed ceramic tiles coloured of size 450x300X7mm thick fixed in verticle surfaces, set and jointed in neat cement slurry and pointed in white and colour cement to match incl 10mm thick screed bed in CM 1:4 complete all as specified and directed by Engineer in Charge.
Dismantling of stone slabs and tiles of andy description or thickness as on platform, shelves, floors etc laid, bedded and pointed in any mortar, complete all as specified and directed by Engineer in Charge.
M&L 20 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table and like over 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engineer in Charge.
Taking down Chowkhats or frames/ steel windows/ventilators, not exc 1.5 Sqm each (without taking off shutters from the frames) complete all as specified and directed by Engineer in Charge.
Taking down chowkats & shutters without taking off shutters from the frame, size of opening exc. 1.50 sqm but not exc 4 sqm each, complete all as specified and directed by Engineer in Charge.
S & F Pressed steel frames for doors with one or more rebates including necessary fixing lugs,hinges, lock strike plate, etc complete all as specified and directed of size 105 X 60mm, complete all as specified and directed by Engineer in Charge.
M&L for PCC (1:3:6) type C-1 using 20 mm graded agg as in back of pressed steel chowkat/ hold fast etc complete all as specified and directed by Engineer in Charge.
Solid PVC door frame of size 50mm x 47mm made out of 5mm plain coloured PVC sheet reinforced with MS square tube, supplying & fixing in opening as per specification and drawing, complete all as specified and directed by Engineer in Charge.
S&F Factory made solid panel PVC door shutter 30mm thick (stile), consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the MS frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, supplying & fixing in the frame at site as per specification and drg complete all as specified and directed by Engineer in Charge.
Supply and fix steel window/ventilator of box section having 1.25 mm thick CRC sheet frame with double shutter inside gauged shutter and outside glazed shutter with one nos steel handle in each shutter,one nos peg stay in each shutter ,complete with glazing bars and 08 Nos of 10 x 10 mm square guard bars in equal spacing, devoited or welded as per sample incl one coat of red oxide primer all as specified and directed.( The rates includes 4 mm thick plain sheet glass and galvanized mild steel wire cloth 0.56 mm nominal dia of wire and average width of aperture 1.18 mm and 2 coat of synthetic enamel paint over a coat of zinc chrome primer) Note : The design of window to be facilitated by cooler fixing provision where ever reqd), complete all as specified and directed by Engineer in Charge.
S&F Anodised aluminium window and ventilator shutters fixed type without sash bar, aluminium section weighing o.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading screws etc complete all as specified and directed by Engineer in Charge.
Supply and fixing, Factory made, 35mm thick plain framed panelled shutters (two panel) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneering on both faces using 2nd class HW as in rail and style. The size of rail and style as per IS-1003 (part – I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engineer in Charge.
S&F 100 mm Butt hinges medium weight, cold rolled mild steel, complete all as specified and directed by Engineer in Charge.
S&F 150 Aluminium anodised barrel tower bolts of extruded section and fixed, complete all as specified and directed by Engineer in Charge.
S&F 300 mm aluminium ally, anodised , sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed ,complete all as specified and directed by Engineer in Charge.
S&F 150 mm extruded Aluminium alloy handles, fabricated type anodised, complete all as specified and directed by Engineer in Charge.
S&F 3 mm thick figured glass pin head type and glazing with oil putty/wooden beads in squares not exc 0.5 sqm in each pane complete all as specified and directed by Engineer in Charge.
S&F galvanised steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with tinned tacks, or galvanised staples complete all as specified and directed by Engineer in Charge.
Taking up or down 15mm bore steel tubing and connections, including cleaning for refixing or removal to store, complete all as specified and directed by Engineer in Charge.
Material and labour 15 mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors , complete all as specified and directed by Engineer in Charge.
Fixing only 15 mm dia steel tubes any grade to walls and ceilings or laying in floors, including new fittings as required complete all as specified and directed by Engineer in Charge.
Taking up or down 20 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by Engineer in Charge.
Material and labour 20 mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed by Engineer in Charge.
Fixing only 20 mm dia steel tubes any grade to walls and ceilings or laying in floors, including new fittings as required , complete all as specified and directed by Engineer in Charge.
Taking up or down 25 mm bore steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and directed by Engineer in Charge.
Material and labour 25 mm dia tubes medium grade galvanised with all fitting and fixed complete to walls and ceilings or laid in floors, complete all as specified and directed by Engineer in Charge.
Fixing only 25mm dia steel tubes any grade to walls and ceilings or laying in floors, including new fittings as required including taking down old pipes, complete all as specified and directed by Engineer in Charge.
Cutting chases, pining in making good to facing where required and pointing in cement mortar 1:3 for concealed water tubing , cutting not exc 10 cm girth , complete all as specified and directed by Engineer in Charge.
Dismantling PVC water tanks Exc 500 Ltr and n exc 1000 Ltr and removing to store, complete all as specified and directed by Engineer in Charge.
Material and labour, for three layered white colour Rotational moulded polyethylene water storage tanks of 1000 ltr Capacity (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed by Engineer in Charge.
Material and labour, 20mm Ball valves, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed as in repairs, complete all as specified and directed by Engineer in Charge.
Material and labour for Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed Screwed both ends for iron pipes or for union and fixedin repair to 20mm dia of pipe, complete all as specified and directed by Engineer in Charge.
M&L Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed Screwed both ends for iron pipes or for union and fixed in repair to 15 mm dia of pipe, complete all as specified and directed by Engineer in Charge.
Material and labour Vitreous china squatting pan , 'Orissa' pattern, size 580 x 440 mm white , with integral foot rests complete including provision of lime concrete bedding fixed as in repairs, complete all as specified and directed by Engineer in Charge.
Material and labour PVC valveless , syphonic action type , flushing cistern, low level ,white, with inlet, ball valve, float and handle, flush pipe of polythelene of low or high density or PVC 32 mm dia , including brackets / fastening assesoriesof 10 litres capacity ,complete all as specified and directed by Engineer in Charge.
S&F vitreous china wash down water closet pan ( pedestal pattern) , white (excluding fixing bolts, flushing cistern and flush pipe) but with & including plastic seat cover of approved colour with flat bottom , and cover and mild steel chromium plated or aluminised hinging device etc complete complete all as specified and directed by Engineer in Charge.
S&F in repair Material and labour Vitreous China wash basin, white , flat back,size 550x400mm fixed on brackets or stands , including 32 mm waste coupling of PTMT (half or full threaded)/ CP Brass and corrugated waste pipewith adopter of 900 mm long, complete all as specified and as directed
S&F in repair Material and labour Vitreous China wash basin white, oval type counter top of size 550mmx400mm fixed on and including cast iron cantilever brackets 32mm dia brass waste coupling and 32mm dia PVC waste pipe waste fitting etc complete all as specified and directed by Engineer in Charge.
S&F in repair vitreous china Urinal, full stall type white (excluding flushing cistren, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plug with and including 60mm long brass screw, pointing around urinal back in cement fixixng automatic flusing cistern with bracket flush pipe grating and union for discharge pipe complete all as specified and directed by Engineer in Charge.
S&F vitreous china Urinal, full stall type white (excluding flushing cistren, flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2 securing urinal to plug with and including 60mm long brass screw, pointing around urinal back in cement fixixng automatic flusing cistern with bracket flush pipe grating and union for discharge pipe complete all as specified and directed by Engineer in Charge.
S&F urinal spreader of PTMT any colour for fixing with 15 mm dia pipe complete all as specified and directed by Engineer in Charge.
Supply and Fixed in repair 15 mm dia bore angular stop cock with wall flange cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed by Engineer in Charge.
Supply and Fixed 15 mm dia bore angular stop cock with wall flange cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and directed by Engineer in Charge.
Supply and Fixed in repair 15 mm dia bore concealed stop cock cast copper alloy chromium plated with long sahnk , fancy type,screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union complete all as specified and as directed by Engineer-in-charge
Supply and Fixed in repair PVC connections 15 mm size with PTMT nuts of length 450mm, complete all as specified and directed by Engineer in Charge.
Supply and Fixed in repair PVC connections 15 mm size with PTMT nuts of length 600 mm, complete all as specified and directed by Engineer in Charge.
Supply and Fixed in repair, 15 mm dia Bib taps , fancy type Chromium plated , screwed down , screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer in Charge.
Supply and Fixed, 15 mm dia Bib taps , fancy type Chromium plated , screwed down , screwed for iron pipe or for brass ferrule complete all as specified and directed by Engineer in Charge.
Supply and Fixed in repair, Brass Chromium plated shower rose 125 mm size with or without swivel joints,including fixing to steel pipe or union ,complete all as specified and directed by Engineer in Charge.
Supply and Fixed in repair, stainless steel soap dish , complete all as specified and directed by Engineer in Charge.
Supply and Fixed in repairs, Glass Corner shelf (single) of size 300 MM(brass brackets) complete all as specified and directed by Engineer in Charge.
Supply and Fixed in repairs, Brass CP tubular towel rail of 20 mm dia, D type ,60 CM long between flange , complete all as specified and directed by Engineer in Charge.
S&F stainless steel towel ring round/square with cap , with fixinf screws, complete all as specified and directed by Engineer in Charge.
S&F in repairs SS grating, 125 mm size( Dia /square) without hole , complete all as specified and directed by Engineer in Charge.
S&F in repairs Pillar taps 15 mm dia, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe complete all as specified and directed by Engineer in Charge.
S&F Pillar taps 15 mm dia , cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed by Engineer in Charge.
S&F in repairs of CP Health faucet set with 15mm dia 1 mtr long tube acrylic type complete all as specified and directed by Engineer in Charge.
Taking down cement plaster/cement mud plaster on brick walls etc, incl racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed by Engineer in Charge.
M&L for rendering 15mm thick in cement mortar 1:6 on fair faces of brick/concrete surfces finished even and smooth without using extra cement, complete all as specified and directed by Engineer in Charge.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick/concrete surfaces finished even and smooth without using exta cement with using WPC @3% by the wt of cement. WPC shall be measured and paid seperately.
M&L for rendering 5mm thick in cement mortar 1:4 on fair faces of brick/concrete surfces as in ceiling finished even and smooth without using extra cement complete all as specified and directed by Engineer in Charge.
M&L for APP based polymeric membrane of minimum 3 mm thick and minimum weight not less than 3.0 Kg/sqm, reinforced with polyster non woven fabric matt (weight not less than 150 gm/sqm), laid with forced application over roof surface with a coat of hot blown bitumen conforming to IS-3384-1965 of grade 85/25 @ 1.2 kg/Sqm at bottom of the membrane as bonding material, complete all as per manufacturer's instructions all as specified and directed by Engineer-in-Charge.
S&F Applying two coat of aluminium paint over the APP modified membrane @ 0.11Kg/sqm complete all as specified and directed by Engineer in Charge.
M&L for preparation of new steel or iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paints over a coat of red oxide, zinc chrome primer complete all as specified and directed by Engineer in Charge.
M&L for preparation of new wood or wood based surface of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paints over a coat of pink primer complete all as specified and directed by Engineer in Charge.
M&L for prepration of new plastered surfaces of ceiling and applying three coats of white wash, complete all as specified and directed by Engineer in Charge.
M&L for preparation of old decorated surfaces of ceiling and applying one coats of white wash, complete all as specified and directed by Engineer in Charge.
M&L for prepration of new plastered surfaces of walls and applying three coats of white wash, complete all as specified and directed by Engineer in Charge.
M&L for preparation of old decorated surfaces of walls and applying one coats of white wash, complete all as specified and directed by Engineer in Charge.
M&L for preparation of new plastered surfaces of walls, pillars, cornices and applying Two coats of premium quality exterior emulsion paint over priming coat of exterior primer complete all as specified and directed by Engineer in Charge.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings,heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engineer in Charge.
S&F in repairs 110mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed by Engineer in Charge.
S&F in repairs 75mm dia bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed by Engineer in Charge.
S&F in repairs 110mm dia bore PVC (SWR) bends any radius complete all as specified and directed by Engineer in Charge.
S&F in repairs 75mm dia bore PVC (SWR) bends any radius complete all as specified and directed by Engineer in Charge.
S&F in repairs 75 mm PVC (SWR) vent cowl complete all as specified and directed by Engineer in Charge.
S&F stack clamps out of 50 mm by 5 mm flat iron and 16 mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof for 75mm/100mm dia bore of pipe, complete all as specified and directed by Engineer in Charge.
S&F in repairs PVC (SWR) floor trap plain with grating incl jointing with solvent cement of 75mm dia complete all as specified and directed by Engineer in Charge.
S&F in repair PVC (SWR) gully trap 125/110 mm,setting and jointing with solvent cement complete all as specified and directed by Engineer in Charge.
Demolition of reinforced cement concrete of any description and in any position , cut as required to facilitate demolition, complete all as specified and directed by Engineer in Charge.
M&L for Pre cast RCC cover slab (1:2:4) type B-1 (Using 20 mm graded crushed stone aggregate ) as in manhole cover slab etc and set in Cement Mortar (1:4) including necessary form work complete all as specified and directed by Engineer in Charge.
Excavating in trenches n exc 1.5m wide and n exc 1.5m depth and getting out in soft / loose soil complete all as specified and directed by Engineer in Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed by Engineer in Charge.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed by Engineer in Charge.
Demolition and breaking up drain pipe SGSW/CI/PVC pipes of 110/150mm dia from trenches including cement concrete haunching etc complete all as specified and directed by Engineer in Charge.
S&F PVC (SWR) 150mm bore (dia) 6 kg/Sqcm Soil, Waste and Ventilating Pipe, single socketed, in any length with PVC Joints, with or without Ears, laid in Floors, complete all as specified and directed by Engineer in Charge.
M&L Concrete bed to drain pipes including forming cradles in PCC 1:4:8 type D2 using 40 mm graded aggregate for PVC (SWR)/RCC, Soil pipes after they are laid and tested for 150 mm dia bore pipe complete all as specified and directed by Engineer in Charge.
Cutting into existing manholes for connecting new drains 150/200mm bore pipe including removing existing branch drain pipes of 150/200mm bore & benching to form branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) surface finished and reforming benching as required and making good surface with plaster etc to match existing , etc complete all as specified and directed by Engineer in Charge.
Demolition of cement concrete unreinforced of any description in any position not exceeding 150 mm thick (below or above ground level), complete all as specified and as directed by Engineer-in-charge.
Material and labour for 75mm thick PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in plinth protection finishing cement concrete surface even and smooth without using extra cemENT, including making construction joint at a interval not exceeding 2.00 m and at each corner / tornn and filled with sealing compound with grade A(normal)in 25/30 , complete all as specified and as directed.
M&L for 100 mm thick Cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base to paving complete all as specified and directed by Engineer in Charge.
M&L for Coloured Chequred cement concrete tiles 20cm x 20 cm x 25 mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and directed by Engineer in Charge.
S&F roof trusses (framed) , trussed purlins crane gantries rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces cleats etc. complete all as specified and directed by Engineer in Charge.
S&F Pre-painted galvatume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer in Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engineer in Charge.
M&L for suspended false ceiling using E-grid 2430, 180 GSM (exposed ceiling suspension system ) of grid size 600mmx600 mm with main runner 38 mm x 24 mm and wall angle 24mm x 24mm using 4mm thick High Pressure stean Crude Everest Non Asbestos Fiber Cement plain Board (E-Board Classic) in & including a grid of GI system duly suspended with 4mm dia GI wire hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip providing positions for light fixtures,air conditioning diffuser and ducts ,sprinkler ,smoke detectors etc.The main runners to be secured to structural soffits by hanger @ 1220 mm maximum c/c. the last hanger at the end of each main runner should not be placed at more than 450mm from the adjucent wall,Flush fitting 1220 mm cross tee to be interlocked between main runners @ 610mm Centre/Centre,so as to form 600mm x 600 mm grid complete all as specified and directed by Engineer in Charge.
M&L submain wiring with 2 runs of copper conductor PVC insulated unsheathed cable 1100 volt grade 4 sqmm drawn through PVC conduit medium grade ISI marked 25mm dia as per IS specification fixed concealed in wall/ceiling including conduit and conduit accessories and incl provn of PVC insulated 4 Sqmm multistranded copper conductor as earth continuity conductor connected to earth dolly all as specified including dismantling old and making good to the disturbed surface by plastering and two coat of distamper complete all as specified and directed by Engineer in Charge. Note : Two runs of 4 sqmm cable alongwith one run of 4 Sqmm PVC insulated unsheathed copper conductor as earth wire, conduit and conduit accessories will be measured as one length.
M&L for point wiring light point / bell point with single core PVC insulated unsheathed 1100 volt grade cable with stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through in existing concealed conduit, fixed on wall, ceiling with GI saddles GI screws, rawal plugs (concealed conduit wiring) with all fittings including Tee, junction boxes and provision of modular metal flush box of suitable size modular white cover plate with frame for mounting switch sockets and regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 volts grade cable with stranded coper conductor of size 1.5 Sq mm (Nominal area) complete all as specified and directed By Engineer in charge. NOTE:- After rewiring cutting chasing portion should be matched with existing finishes of walls.
All as per item No.126 above but 5 Amp socket outlet, independent complete all as specified and directed by Engineer in Charge.
All as per item No.126 above but 5 Amp socket outlet, same board complete all as specified and directed by Engineer in Charge.
S&F Switch piano type 5 amp SP one way ISI Marked complete all as specified and directed by Engineer-in-Charge.
S&F Socket outlet 3 pin 5 Amps flush type complete all as specified and directed by Engineer-in-Charge.
Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engineer-in-charge
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer in Charge.
S&F LED light fitting 1x9W/ 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer in Charge.
S&F for MCB SP 5 to 32 Amps, 240 volts curve 'C',breaking capacity 10KA, Complete all as specified and directed by Engineer in Charge.
S&F for MCB SPN 32 /40 Amps, 240 volts, curve 'C', breaking capacity 10 KA, Complete all as specified and directed by Engineer in Charge.
S&F Sheet metal enclosures DB Double door type 8 way SPN 240 volt including 200 Amps rated bus bar with neutral link Complete all as specified and directed by Engineer in Charge.
S&F for ceiling rose surface bakelite 65x50mm two to three terminals Complete all as specified and as directed by Engr-in-Charge.
Supply and fix metallic exhaust fan complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m complete all as specified and directed by Engineer in Charge.
M&L Earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected toand including galvanized earth lead wire 4.0 mm dia upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc complete all as specified and directed by Engineer in Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 4 core,complete all as specified and directed by Engineer-in-Charge.
M&L for Excavation in trenches not exceeding 1.5 Mtr wide and not exceeding 1.5 Mtr in deep for foundation of poles/stays/cables/Pipe lines etc and getting out in soft/loose soil, complete all as specified and as directed by Eng -in - Charge.
M&L for Returning, filling in including spreading, leveling, watering and well ramming in layers each not exceeding 25 cm thickness, complete all as specified and as directed by Eng -in - Charge.
M&L for Removing surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point, complete all as specified and as directed by Eng -in - Charge.
M&L for brick protection with sub class 'B' bricks laid dry flat over electric cable in trenches all as specified and directed by Engineer-in Charge.
M&L for Sand cushioning with a layer of sand 80mm thick consolidated before laying of cable and 150mm thick consolidated after laying of cable in trenches ducts for electric cable protection including consolidation complete all as specified and directed by Engineer in Charge.
yogesh kumar contractor (BID ID -3117973)
REYANSH GARG AND COMPANY (BID ID -3114469)
M/s DHEERAJ JAIN CONSTRUCTION COMPANY (BID ID -3114267)
STELLAR PROJECTS (BID ID -3114931)
M/s Kamal Builders (BID ID -3113309)
GUPTA AND ENGINEERS (BID ID -3118093)
M/s BALDEV SINGH (BID ID -3119212)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .