| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.5 LAccepted-Finance 03 GOVIND PURAM EIDGHAH ROAD BIJNOR BIJNOR UTTAR PRADESH 246701 | BIJNOR | UTTAR PRADESH | 246701 | ₹11.5 L | L1 | Accepted-Finance OK |
| 2 | L2₹16.5 L+₹5.1 L (44.1%)Accepted-Finance | ₹16.5 L+₹5.1 L (44.1%) | L2 | Accepted-Finance OK |
| 3 | L3₹19.9 L+₹8.4 L (73.4%)Accepted-Finance | ₹19.9 L+₹8.4 L (73.4%) | L3 | Accepted-Finance OK |
| 4 | Rejected-Technical | - | - | Rejected-Technical NON FULFIMENT OF PQR (EXPERIENCE) |
Tender Value
₹23.2 L
EMD Value
₹24,000
Closing Date
12 Jan 2022, 5:00 pmClosed
SE ETC NOIDA
220 KV SUBSTATION SECTOR-20 NOIDA
Patrolling and annual general maintenance of various transmission lines under ETD-I Noida
2021_UPTCL_664396_1
E-T-51/ETCN/2021-22
Open Tender
Electrical Works
Item Rate
365 days
NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,770
EE ETD NOIDA
₹24,000
28 Jan 2025
24 Dec 2021
13 Jan 2022
24 Dec 2021
12 Jan 2022
24 Dec 2021
Amount
Regular tower to tower ground patrolling of following mentioned Line. Patrolling work consist of detection of the defect like missing/theft tower parts/bird nest , hot point,punchered/flash over insulator disc, dislocation of vibration dampers/damaged conductor /earth wire ,checking of foundation / stub & position of trees in the corrider of 27 meter of the line.Patrolling shall be done regurlarly on quarterly basic i.e 4 times in the year. Submission of patrolling report on perscribed computerized Performa in 3 sets after each patrolling duly binded along with one soft copy within 10 days after completion of the patrolling.
i)220KV D/C Greater Noida(400kV)-Sec-20 Noida Line Circuit I ii)220KV D/C Greater Noida(400kV)-Sec-20/Sec-62 T-Off Noida Line Circuit II iii)220 kV Ghazipur-Sec-20-Botanical Garden-BTPS Line iv) 220 KV S/C Gr. Noida(400kv)-Sec-129 Noida Line-Circiut-II v) 220 KV S/C GIS S/S Sec-148-Sec-129 Noida Line-Circiut-I
i) 132 KV D/C Sec-129 Noida-Samsung Line ii)132 KV D/C Sec-115 Noida LILO Line Circuit II iii)132 KV D/C Sec-20-Sec-115- Sec-45 Noida upto pt. sec-115 S/S iv)132 KV D/C Greater Noida(400kV-SurajpurSector-20 Noida Line v)132 KV Bhangel-Sec-45- Sec-129 LILO Line vi)132 KV Sector-45-Sec-115- LILO Line vii) 132 KV Sec-45- Sec-129 Line viii)132 KV Sec-20- Sec-45 LILO Line
Opening/cutting of nut-bolts of remaning cut pieces of tower parts theft by miscreants safely with the help of gas cutter/hacksaw blade including all required labour and T&P for proper complition of works satisfactory.
Fabrication & fixing of tower parts/members from scrap GI angle including carriage of angels from the substation store, punching hole, proper tightening of nut & bolts, punching & chamfering of bolts at different of above transmission line.
Tack welding of New Nut & Bolts.
Strengthening/Replacing of damaged jumpers ( tension tower ) in emergency to restore the supply.
Tightening of Red hot/loose 220/132KV jumper on both ends at Lattice tension towers.
Tightening of Red hot/loose 220/132kV jumper on both ends at tension Monopole .
Repairing of damaged ACSR Panther/Zebra conductor by using repair sleeves either one or more as per requirment.( repair sleeve will be provided by the department.)
Replacment of damaged/puncture insulator string at different tower location including carriage of matrial from store to site and remaining / scrap matrial back to store . Including all associated work.
For Tension String
For Suspension String
Lopping, Chopping & cutting of tree branches in the 27 Mtr. Safe Corridor of above Transmission line .
In Emergency Tower to Tower ground patrolling of 220/132 kv lines after tripping of line. Team will move well equipped for all assocaited work i.e. looping , chopping of trees.removal of foreign wire, nest to restore the supply.
Cleaning of pilot String of 220/132 kV above line
Removal Of Bird Nest of 220/132 kV above line
Removing of Sign Board,advertisement board ,from the towers of 220/132 kv above line .
Half yearly hot spot scanning of mid span joint,repair sleeve, Dead end & Jumpers of following 132kV Lines.Real line pictures of thermoscanning of Jumpers,Dead end , midspan Joint & repair sleeve comprising all details of tower & Temperature must be provided in 2 sets in A4 photo sheet, one A4 sheet should not contain more than 4 photographs.
R.K.Engineers & Traders
BARKATI ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .