| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.2 LAccepted-AOC JAIGAON MANGLANBARI | JALPAIGURI | WEST BENGAL | 734001 | 1 | Accepted-AOC Being L1 Bidder | |
| 2 | 2₹2.3 L+₹11,572 (5.38%)Rejected-AOC | 2 | Rejected-AOC Being L2 Bidder | |
| 3 | 3₹2.5 L+₹32,474 (15.1%)Rejected-AOC | 3 | Rejected-AOC Being L3 Bidder |
Tender Value
₹2.2 L
EMD Value
₹4,000
Closing Date
25 Aug 2021, 12:00 pmClosed
SE OMC-III,2X250MW CTPS PARICHHA
OFFICE OF SE OMC-III,2X250MW CTPS PARICHHA JHANSI
Breakdown maintenance and Cutting welding work of hardware, fittings of isolating valves, impulse lines etc. of C and I equipments in unit 5 and 6 2X250 MW CTPS Parichha
2021_RVUNL_605151_1
T04/OMC-3/CIMD-I/CTPS/2021-22
Open Tender
Power/Energy Projects/Products
Lump-sum
365 days
2X250MW, CTPS, PARICHHA JHANSI
Refer to tender document
2 documents required · 2 mandatory
₹590
refer to tender documents
₹4,000
26 Nov 2021
22 Jul 2021
27 Aug 2021
22 Jul 2021
25 Aug 2021
22 Jul 2021
22 Jul 2021 - 25 Aug 2021
Arresting the leakage from 10mm and 20mm impulse line by cutting and/or welding.
Replacement of damaged 10mm/20mm impulse line by cutting and/or welding with proper coupling, adopter tail nipples, clamping & required bends.
Replacement of damaged isolating valve for pressure/ Temperature gauges & Switches, instrument air/oil/steam line, transmitter etc.
Re-visioning & servicing of high pressure isolating valve size (0.5”, 1”and 2”) by lapping, grinding and replacement of gland packing.
Fabrication & modification in end fittings of pressure/ temperature gauges & switches, Transmitter, solenoid valve, transmitter manifolds.
Cutting and complete removal of old and damaged 5/3/2/ way H.P./L.P. manifolds of SS 316 from LIE panels. Cleaning, grinding of 10mm/20mm impulse line and welding of new/repaired 5/3/2/ way manifolds with the help of socket with suitable welding electrodes at two process connections.
Repairing of the old/defective 5/3/2 way manifold by cutting from site and dismantle/replace the stem/gland of the valve or welding of the defective body of the manifold.
Cutting and removal of odd size of female fittings of pressure gauges at different places of unit and auxillaries of 2x250 MW and replacement and welding of new female fittings.
Mounting/welding of snubber and isolating valves on high pressure line before pressure gauges for obtaining correct readings and improve the life of pressure gauges.
Repalcement of old and damaged hose pipe by cutting, welding and grinding flexible SS hose pipes (which are under division’s scope) installed at various locations of 2X250 MW units
Fabrication & modification of different sizes of links and other fittings of PFT and Positioners of various pnematic instruments installed at diffierent locations of 2X250 MW units.
M/S S.K.ENGINEERING WORKS
M/s JAHANGIR ENTERPRISES
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .