Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹2.5 LAccepted-Finance | L-1 | Accepted-Finance L-1 | |
| 2 | L-2₹3.6 L+₹1.1 L (41.7%)Rejected-Finance | L-2 | Rejected-Finance L-2 |
Tender Value
₹2.4 L
EMD Value
₹4,829
Closing Date
22 Jul 2023, 3:00 pmClosed
EE E BSNL Jabalpur
O/o EE E BSNL JABALPUR NEW CTO Building Jabalpur
Addition alteration of Electrical Installation and miscellaneous Electrical work in the rented portion for MP High Court at the New CTO Building , Jabalpur. SUB HEAD Additional requirement of high Court in rent out building
2023_BSNL_160691_1
16/ EE (E)/BSNL/JBP/2023-24
Open Tender
Electrical Works
Works
60 days
CTO Jabalpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
BSNL
₹4,829
6 Oct 2023
11 Jul 2023
24 Jul 2023
11 Jul 2023
22 Jul 2023
11 Jul 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit / Casing Capping with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
Suplying and fixing of following size PVC casing capping directly on wall / partition panels with screws / fasteners & drilling etc. complete as required.
20 mm x 10 mm.
25 mm x 10 mm.
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel / PVC conduit / Casing and Caping as required.
1 x 1.5 sq. mm
2 x 1.5 sq. mm
3 x 1.5 sq. mm
3 x 2.5 sq. mm
6 x 2.5 sq. mm
2 x 4 sq. mm
3 x 4 sq. mm
6 x 4 sq. mm
Supplying and fixing of following piano type switch / socket on existing fittings / switch box / cover including connections etc. as required . ( any ISI Marked )
5/6 amps switch .
5 pin 5/6 amps socket outlet .
15/16 A switch
6 pin 15/16 A socket outlet
Heavy duty regulator
18 Watt LED Tube Fitting
15 Watt LED Lamp
200 mm x 250 mm X35 mm depth Sunmica wooden boards
180 mm x 100 mm X35 mm depth Sunmica Wooden boards
Supplying & Fixing of 8 mm dia 'S' type fan hook in ceiling including digging and tracing re-inforcement rod in ceiling and making good the damages /painting with minor civil works as required.
Supplying and fixing of 230 V & 50 Hz AC Supply operated 1400 mm sweep Ceiling with suitable speed regulation including making suitable fixing / mounting arrangement along with interconnection etc. complete testing as required. [ Bajaj / Crompton / Havells or similar superior make ]
Supplying and fixing extra down rod of 10 cm length G.I. pipe, 15 mm dia, heavy gauge including painting etc. as required . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)
Supplying and fixing of 230 V & 50 Hz AC supply operated 400 mm sweep wall bracket fan with suitable speed regulation and oscillation control switches including making suitable fixing / mounting arrangement along with inter connection etc. complete testing as required. [ Bajaj / Crompton / Havells or similar superior make ]
Supplying and Fixing of Sunmica / phenolic laminated Sheet 3 MM thick suitable size on existing switch boards complete tighting with nut bolts / screws etc. complete as required .
SITC of indoor cubical type wall / floor mounting Control Panel Suitable for 415V 3 phase 50 Hz, A.C. Supply system made out of 16 gauge M.S. sheet suitably bended and welded to impact strength housing for 250 Amp MCCB , Bus bar fixing arrangement , gasketed & vermin proof i/c painting with enamelled paint ( Colour approved by Engineer-in-charge ) i/c interconnection with suitable size of copper conductor cable crimping the lugs ferrules and sign writing complete as per specifications and minor Civil work , the Panel includes the following items with ITC connection etc. complete as required : -
TAB250C X 250AC 3P Three Pole HPL Make MCCB as Main Incomer Supply - 1 No.
Voltmenter ( 0 - 500 V ) Digital Type i/c interconnection with suitable gauge of copper conductor Cable etc. - 1 No.
Ammeter ( 0 - 30 Amp ) i/c CTs with with CT ratio i/c interconnection with suitable gauge of copper conductor Cable etc. - 1 Sets .
Indicating lamps LED type for RYB Phase Indication - 2 Sets
S/F 400 amp 4 strip alu. Bus bar of suitable length - 1 Set i/c colour code sleeves .
Space for cable termination with heavy duty connector both sides of panel .
Drawing of the MV Panel shall be got approved before fabrication and to be submitted after completion.
Supplying and Laying of one number PVC insulated & PVC sheathed / XLPE 3½ x 50 sq mm Alumn Conductor power cable (ISI Make) of 1.1 kV grade in the existing masonry open duct / Open Air / RCC/ HUME/ METAL pipe/wall surface as required. ( Rate are inclusive of Transportation and Extra labour and tools cost for laying of cable on a busy running traffic etc. )
Supplying and making end termination with brass compression gland and aluminum lugs for the following size of PVC insulated and PVC sheathed / XLPE aluminum conductor cable of 1.1 KV grade as required. ( Size 3½ X 50 SQMM )
ATUL TRADERS &CONTRACTOR PROP-ATUL MISHRA
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .