33KV Line Strengthening work for Better supply at various places under BP 2024-25
2024_PVVNL_922596_1
33KV Line Strengthening work for Better supply at various places under BP 2024-25
Open Tender
Electrical Works
Item Rate
60 days
S.E., EUDC-II
Attached in DOC
2 documents required · 2 mandatory
₹3,540
S.E. EUDC-II, Noida.
₹40,000
31 May 2024
20 Apr 2024
17 May 2024
20 Apr 2024
17 May 2024
20 Apr 2024
Amount
33@11 ds0oh0 fo|qr midsUnz lSDVj&88 uks,Mk ds vfrfjDr lkslZ gsrq fyaDM+ ykbZu ds fuekZ.k dk dk;Z ftls 132@33 ds0oh0 fo|qr midsUnz Hkaxsy uks,Mk ls iksf"kr iks"kd la0&06@07 ls tksMdj fo|qr vkiwfrZ djus dk dk;ZA
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 3 to 14
ST/PCC 11 Mtr long Pole
33KV 3X300SQMM XLPE CABLE
ACSR Dog Conductor
33KV V-Type Steel Cross Arm
MS Channel 125x65x3200mm
MS Angle 75x75x6mm
33KV Polymerice Disc Insulator with Fittings
33KV Polymerice Pin Insulator with Pin.
33KV X Arm
Stay set complete (G.I.Stay rod 16x1800mm, Stay wire 5Kg, Guy insulator, G.I.Stay clamp, bolt, nut & wasther with concrete grouting) for 11KV line.
Heat Shrinkable outdoor type end termination cable jointing kit suitable for 33KV XLPE 3x300 Sq.mm. cable (Make - Raychem/3M/Denson)
Heat Shrinkable Straight Through Box suitable for 33KV XLPE 3x300 Sq.mm. cable (Make - Raychem/3M/Denson)
Errection of above Following material and Supply and errection of the below material for completing the works as per RESPO.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) ST/PCC - 11 Mtr. Long Pole
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 'F' bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required. Single Pole (a) ST/PCC - 11 Mtr. Long Pole
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Single Pole and Double Pole (a) ST/PCC - 11 Mtr. Long Pole
Laying, spreading, lifting and final sagging of 3 phases ACSR Dog conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos. Conductor in parallel as per site requirement.
FIXING OF PIN INSULATOR WITH PIN, COMPLETE WORK IN ALL RESPECT.
FIXING OF Disc. INSULATOR WITH Fitting, COMPLETE WORK IN ALL RESPECT.
FIXING OF MS CHANNEL AS PER SITE REQUIREMENT.
FIXING OF MS ANGLE AS PER SITE REQUIREMENT.
Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps and Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
FIXING OF 33KV V-Type Steel Cross Arm with COMPLETE WORK IN ALL RESPECT.
FIXING OF 33KV X Arms with COMPLETE WORK IN ALL RESPECT.
Preparation of 33 KV Power Cable ends: Making of 33 KV XLPE Heat shrinkable outdoor jointing kits suitable for 3x300sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect.
Laying and commissiong of 33KV 3x300sqmm XLPE Cable Double Ckt. after digging trench of dia 220 mm in two parallel bores for Double Curcuit by manual method at a depth of 1.50 mtrs to 2.50 mtrs. (as requirement at site) below the ground level for laying cable and refilling of trench including connections at both ends after providing and crimping of lugs of proper size for completion of work and Providing & Laying of Ist Class Bricks, along the length on both side of 11KV XLPE Cable in Cable Trench (minium 18No. Bricks/Mtr per Cable) and Stone Slab of size 450x600x50mm on top of the each Cable, Providing 150 thickness mm River sand for cushion beneath and 150mm above the cable and Back filling of excavated earth in the cable trench upto the ground level and ramming properly.
Laying of 33 KV 3X300 Sq.mm XLPE Cable in the air on cable Riser Double Pole, existing trench cable trench, nala x-ing & G.I.Pipe and making connection complete at both ends.
Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop and making risers at double pole and re-filling of pits in proper manner with required material at kacha/pakka and hot mix road. (All Work and material in the scope of contractor)
PROVIDING AND FIXING OF NUT, BOLT AND WASHERS AS PER REQUIREMENT.
Tree Cutting and Chopping in the areas of above line. (All work in the scope of contractor.)
Providing and Driving of MS earth rod of size 20x2500 mm in earth and jointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballast in ration 1:4:8 in Block 600*600*300 mm with binding & nuzzling including providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor)
Repairing of H.V. 33 KV Underground cable faults in various voltage level cables on Turnkey Basis (Providing and its Commissioning New Technology Fault Locator Machine with Driver, and other material related to work etc.) in the areas of SDO -V, Noida. The Contractor shall be responsible for providing the Cable Fault Locating Machines of appropriate and latest version & specifications along with experienced technician, helpers and driver etc. by their own end for locating the 33 KV Cable Fault in the above SDO areas and Pin pointing within two meter of cable fault, exposing the same in the underground HT cable (33 KV) including cutting of the Faulty Cable, its meggering & sealing of healthy cable. In addition to locating and pin pointing of cable faults, the contractor shall also be responsible for digging of cable trench of suitable size so as to enable making of cable joints (one or two straight through joints depending on the requirements), it shall also include cutting of the faulty cable in sufficient length. Road cutting & digging thereof so that cable may be taken out for jointing work. Dressing of road as may be required at various places. as per Following :
33 KV cable fault location & trench digging with the help road cutter/digging machine/tractor etc. as per site requirement (size of trench 4 m length & 1.5 m width) in SDO -V, Noida areas.
Fixing, Making and commissioning of 33 KV Straight through with the help of Jointer per 33 KV joint for filling with complete connections in all respect. (33 KV 3x300/400 Sq.mm. Outdoor, Indoor jointing Kits and Straight through of Raychem/ 3M/ Denson make and Jointer provided by the contractor. and Replacement of 33 KV damaged cable in trench after making joint and filling of sand/brick/soil as per site requirement.
132 ds0oh0 Hkaxsy ls iksf"kr QhMj 01ua0 33@11 ds0oh0 fctyh?kj ,u0,l0bZ0tsM0 vksYM dh 33 dsoh 3x300sqmm Cable ykbZu dk eSVks LVs'ku ,o ukys ds uhps {kfrxzLr 500 ehVj dsfcy dks cnyus gsrqA
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 39 to 40
33KV 3X300SQMM XLPE CABLE
Heat Shrinkable outdoor type end termination cable jointing kit suitable for 33KV XLPE 3x300 Sq.mm. cable (Make - Raychem/3M/Denson)
Errection of above Following material and Supply and errection of the below material for completing the works as per RESPO.
Supply of 140mm OD PN-4-PE-80 Grade UV Stabilized HDPE Pipe.(PVVNL GTP APPROVED)
Drilling of dia 220 mm in two parallel bores for Double Curcuit by trenchless method by horizontal boring machine at a depth of 1.50 mtrs to 2.50 mtrs. (as requirement at site) below the ground level with complete work in all respect as per RESPO.
Laying of HDPE Pipe PE-80, PN-6, DN-140mm dia by HDD trenchless method for 33KV, 3x300sq.mm XLPE cable as per site requirement. (PVVNL GTP APPROVED HDPE PIPE SHALL BE SUPPLIED WITH INSPECTION.)
Laying and commissiong of 33KV 3x300sqmm XLPE Cable Double Ckt. in HDPE Pipe dia after digging HDD trenchless method boring including complete connections at both ends after providing and crimping of lugs of proper size for completion of work. as per site requirement.
Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop and making risers at double pole and re-filling of pits in proper manner with required material at kacha/pakka and hot mix road. (All Work and material in the scope of contractor)
Laying of 33 KV 3X300 Sq.mm XLPE Cable in the air on cable Riser Double Pole, existing trench cable trench, nala x-ing & G.I.Pipe and making connection complete at both ends.
Preparation of 33 KV Power Cable ends: Making of 33 KV XLPE Heat shrinkable outdoor jointing kits suitable for 3x300sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect.
Removal of Damaged HT XLPE Cable 1x400sqmm in pieces and safe carriage of its from Site to any Store Centre of PVVNL Discom including loading and unloading from both ends.
220 ds0oh0 izkFkfed midsUnz lSDVj 129 ls 33@11 dsoh Mh CykWd gkWtjh dkWEiySDl dh ,YVjusV 33 ds0oh0,0 dh vaMjxzkmaM ykbZu cukus dk dk;ZA
Safe carriage of following stock material, from any of the Store Center of PVVNL to work site including Loading from Store and safe unloading at site for Item No. 52 TO 53
33KV 3X300SQMM XLPE CABLE
Heat Shrinkable outdoor type end termination cable jointing kit suitable for 33KV XLPE 3x300 Sq.mm. cable (Make - Raychem/3M/Denson)
Heat Shrinkable Straight Through suitable for 33KV XLPE 3x300 Sq.mm. cable (Make - Raychem/3M/Denson)
Errection of above Following material and Supply and errection of the below material for completing the works as per RESPO.
Supply of 140mm OD PN-4-PE-80 Grade UV Stabilized HDPE Pipe.(PVVNL GTP APPROVED)
Drilling of dia 220 mm in two parallel bores for Double Curcuit by trenchless method by horizontal boring machine at a depth of 1.50 mtrs to 2.50 mtrs. (as requirement at site) below the ground level with complete work in all respect as per RESPO.
Laying of HDPE Pipe PE-80, PN-6, DN-140mm dia by HDD trenchless method for 33KV, 3x300sq.mm XLPE cable as per site requirement. (PVVNL GTP APPROVED HDPE PIPE SHALL BE SUPPLIED WITH INSPECTION.)
Laying and commissiong of 33KV 3x300sqmm XLPE Cable Double Ckt. in HDPE Pipe dia after digging HDD trenchless method boring including complete connections at both ends after providing and crimping of lugs of proper size for completion of work. as per site requirement.
Digging of pits of size 4 mtr x 4 mtr x 1.5 mtr for cable loop and making risers at double pole and re-filling of pits in proper manner with required material at kacha/pakka and hot mix road. (All Work and material in the scope of contractor)
Laying of 33 KV 3X300 Sq.mm XLPE Cable in the air on cable Riser Double Pole, existing trench cable trench, nala x-ing & G.I.Pipe and making connection complete at both ends.
Preparation of 33 KV Power Cable ends: Making of 33 KV XLPE Heat shrinkable outdoor jointing kits suitable for 3x300sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect.
Preparation of 33 KV Power Cable ends: Making of 33 KV XLPE Heat shrinkable Straight Through suitable for 3x300sqmm XLPE Cable after duly plumbing and taping of cable, providing, fixing and crimping of proper size good quality lugs with complete connention in all respect.
M/S SURYA ELECTRICALS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .