Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.7 LAccepted-AOC 217 ARHAT BAZAR KASAULI DISTT SOLAN HP 173204 | SOLAN | HIMACHAL PRADESH | 173204 | L1 | Accepted-AOC L1 QUOTED | |
| 2 | L2₹18.7 L+₹43,905 (2.40%)Rejected-AOC | L2 | Rejected-AOC L2 QUOTED |
Tender Value
₹21.1 L
EMD Value
₹42,300
Closing Date
5 Feb 2024, 6:00 pmClosed
GE AF Chandigarh
GE AF Chandigarh PIN-160003 C/o 56 APO
RENOVATION OF BLDG NO P-111 AND PROVN OF CERTAIN MINOR WORKS AT AF STATION KASAULI
2024_MES_636399_1
GE(AF)/CHD/T-58/2023-24
Open Tender
Civil Works
Item Rate
183 days
Kasauli
All as per NIT and Tender documents
9 documents required · 9 mandatory
₹500
GE AF Chandigarh
₹42,300
Yes
20 Mar 2024
8 Jan 2024
12 Feb 2024
8 Jan 2024
5 Feb 2024
22 Jan 2024
8 Jan 2024 - 15 Jan 2024
Amount
Excavating in post holes (or similar holes) in soft/ loose soil each n. exc. 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 using graded stone aggregate as in mass concrete such as embedding the fencing posts/ struts complete all as specified and directed.
S&F rolled mild steel sections as Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc conforming to Fe-410W (Gde E-250) complete all as specified and directed.
M&L for preparation of new steel surface of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws including dismantling old corrugated steel sheeting of any thickness as in roof coverings complete all as specified and directed.
S&F pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.5mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws including dismantling old plain steel sheeting of any thickness as in roof coverings complete all as specified and directed.
Dismantling timber scantlings 40 sq. cm and over in section in unframed work, in any position complete all as specified and directed.
M&L for brick work with old size sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6) including dismantling of old brick work complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:3) on concrete surface as in chajja, ceiling etc. finished even and smooth without using extra cement in and including taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish outside MoD land complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:6) on brick or concrete surfaces finished even & smooth without using extra cement in and including taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish outside MoD land complete all as specified and directed.
M&L for rendering 15mm thick on brick or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement in and including taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish outside MoD land complete all as specified and directed.
M&L for rendering 15mm thick on brick or concrete surfaces in cement mortar (1:4) finished even and smooth without using extra cement complete all as specified and directed.
M&L for 15mm thick rendering in cement mortar (1:6) on brick or concrete surfaces finished even & smooth without using extra cement cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surface of walls and applying two coats of oil bond distemper over a coat of primer complete all as specified & directed.
M&L for preparation of new surface and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489: 2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm complete all as specified and directed.
M&L for cleaning of roof slab surfaces including sweaping cleaning & washing down with water to remove dust & providing water proofing treatment of roof consisting as under complete all as specified and directed:- (a) Applying bituminous primer @ 0.30 litre per sqm over cleaned and dry roof surface including parapet. (b) Applying a coat of blown bitumen 85/ 25 grade @ 1.20 kg per sqm over priming coat of roof. (c) Providing and laying 3mm thick APP modified polyester reinforced water proofing membrane with minimum weight of 3.60 kg/ sqm as specified. The APP membrane shall be laid using torch-on application with minimum 10cm side overlap and 15cm end overlap. The APP membrane shall be fixed with termination bar and fasteners and end shall be properly sealed with sealant. The rain water gutter portion shall be finished with cement mortar (1:4) to provide requisite slope towards rain water pipe outlet. Make of APP membrane: Pidilite Industries/ STP/ IWL/ Torch Tar as approved by GE. (d) preparation of new plastered surface and applying two coats of aluminium paint.
M&L for plain cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate, as in padding on roof to maintain desired slope, roof kerb, benching and the like, finished even and fair complete all as specified and directed.
M&L for complete removal of existing treatment from brick/ stone/ plastered surface of walls including brooming down or steel wire brushing scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc, washing, rubbing down and stopping of surfaces using sand paper and applying two coats of oil bound distemper including a coat of primer and 1mm thick wall care putty for smoothing the surface complete all as specified and directed.
M&L for complete removal of existing treatment of brick/ stone/ plastered surface of walls and applying two or more coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/ litre and UV resistance as per IS 15489: 2004, alkali & fungal resistant, dirt resistant exterior paint of required shade in camouflage pattern as approved by GE with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surface complete all as specified.
M&L for Non skid joint free ceramic coloured tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc. set and jointed in neat cement slurry and pointed in white/ coloured cement to match the shade laid over and including 15mm thick screed bed or bedding layer in cement mortar (1:6) and including dismantling old floor tiling including cement mortar bedding, removing serviceable tiles to store and rubbish off the premises and out of defense land complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D-2 using 40mm stone graded aggregate as in sub base of floors including demolition of cement concrete (un-reinforced) in ground floors and paving n.exc. 15cm thickness (below or above ground level) and removing debris out of MoD land complete all as specified and directed.
M&L 40mm thick PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in flooring, finished even and smooth using extra cement complete all as specified and directed.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty or wooden bead in squares n. exc. 0.5 Sqm in each pane complete all as specified and as directed.
S&F 5.5mm thick sheet glass ordinary quality and glazing with oil putty or wooden bead in squares n. exc. 0.5 Sqm in each pane complete all as specified and as directed.
S&F, Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples Complete all as specified and as directed.
S&F 200mm long aluminium anodized barrel tower bolts of extruded section Complete all as specified and as directed.
S&F aluminium alloy, anodized, sliding door bolt 300mm long with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolt and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed.
M&L for metal suspended ceiling system OREO GI laid in plain 600mm x 600mm x 0.5mm (tegular) edge tiles in global white colour to be laid on strong 24mm T-section flanges colour white having rotary stitching on the main runner with web height of 38mm comprising main runner spaced at 1200mm c/c securely fixed to the structural soffit at 1200mm maximum c/c and first/ last suspension system at the end of each main runner not more than 450mm from the adjacent wall, flush fitting 1200mm long cross tees interlocked between main runners at 600mm c/c to form 1200mm x 600mm mould, cut cross tees longer than 600mm having independent support; 600mm x 600mm module to be formed by fitting 600mm long flush fitting cross tees centrally between 1200mm cross tees; perimeter trim to wall angles of size 3000mm x 19mm x 19mm secured to walls at 450mm (maximum) c/c, suspension system accessories consisting of HLC sleeve anchor fasteners of thread size 6.50mm x 25/5 with soffit cleat made of galvanised steel of size 27mm x 37mm x 1.60mm & level clip in dimensions of 85mm x 30mm x 0.80mm with 4mm GI wire including dismantling ceiling boards any thickness, complete all as specified & directed. Make: High steel, Armstrong & Dexune.
Taking down chowkats or frames with shutters (without taking of shutter from the frame) of any description along with fittings exc. 1.50 Sqm but n. exc. 4.00 Sqm each complete all as specified and directed.
Taking down chowkats or frames with shutters (without taking of shutter from the frame) of any description along with fittings n. exc. 1.50 Sqm each complete all as specified and directed.
S&F powder coated (minimum thickness of powder coating 50 micron) anodised aluminium sections as in frame for doors, windows and ventilators (minimum weight not less than 1.20 kg/ RM) with one or more rebates including necessary joining cleats for fixing etc. complete all as specified and directed.
S&F powder coating of any colour (Thickness or powder coating not less than 50 micron) anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, 200 mm aluminium handles D type 2 Nos in each door, 100mm stainless steel hinges 3 Nos in each door, anodised aluminum snap beading screws etc. complete all as specified & directed.
S&F12mm thick prelaminated particle board, exterior grade prelaminated both sides with decorative choice laminated fixed in aluminium shutter/ partition complete all as specified & directed
S&F aluminum door closer (die cast body) hydraulically regulated designation No. 3, universal type, suitable for door shutters of 851 to1000mm in width and of weight between 61 to 80 kgs complete all as specified and directed.
S&F floor door stopper 140mm overall cover plate length of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F aluminium grills powder coated of standard pattern as per drawing No CE A/F/STD/144/02 dated 17.10.2002 fixed to aluminium frames including aluminium fillet to cover the edges around complete all as specified and as directed.
Supply, fabrication and fixing aluminium windows, triple track fabricated with powder coated aluminium sections with three sliding shutters (02 No. glass shutters and 01 No. wire gauzed shutter) with following sections including joining cleats, glazing clips, rubber packaging, snap beading and other builders hardware as required complete all as directed:- [a] Top and side members for three track frame shall be of size 92.00mm x 31.75mm x 1.5mm. [b] Three track bottom rail of frame for sliding of shutter shall be of size 92.00mm x 31.75mm x 1.5mm. [c] Top and bottom rail of sliding shutter shall be of size 40mm x 18mm x 1.55mm. [d] Side rail of sliding shutter with handle and self locking arrangement section shall be of size 40mm x 18mm x 1.55mm. [e] Sliding shutter to be provided with 5.5mm thick tinted glass (Tinted glass to be measured and paid for separately). [f] One shutter to be provided with stainless steel wire cloth 0.36mm dia and width of aperture 1.4mm (Wire cloth to be measured and paid for separately).
S&F aluminium powder coated (minimum thickness of powder coating 50 micron) window and ventilator shutters, side hung type without sash bar; aluminium section weighing not less than 2.2 KG/ RM including necessary joining cleats, glazing clips, rubber packing, aluminium snap beading, screws, aluminium fittings such as peg stays 150mm long (1 No.), hinges type B-21 100mm Long (2 Nos), suitable handle (1 No) to each shutter complete all as specified and directed.
S&F plain tinted glass 5.5mm thick fixed in aluminium frame as in windows/ ventilators complete all as specified and directed.
Taking down carefully aluminium/ copper point wiring (light/ fan/ socket/ power) complete (fittings such as switches, sockets, ceiling roses pendants, regulators, sockets, light fitting etc. to be measured separately), removing materials to store for keeping in safe custody or for taking credit as per Schedule of credit including making good disturbed surfaces of walls, floors etc. all as specified and directed.
M&L for point wiring complete with multi stranded copper conductor cable of size 1.5 sqmm PVC insulated unsheathed FRLS colour coded 1100 volts grade drawn in and including medium grade non metallic rigid PVC conduit 19mm dia or higher fixed on surface/ concealed with all standard fittings such as Tee junction, bends, on existing sunken terminal boxes and new 3mm thick PVC laminated hylam sheet for mounting switch/ sockets etc. including PVC insulated un-shearthed 1.5 sqmm multi-stranded copper conductor cable FRLS colour code cable 1100 volts grade for earth continuity for the following complete all as specified and directed:-
One light point controlled by one switch.
One exhaust fan controlled by one switch/ ceiling fan controlled by one switch .
One 3 pin, 5 Amps socket outlet on the same board with other switches.
One 3 pin, 5 Amps socket outlet on independent board.
All as per item No 43.00 here-in-before but with cable of size 4.00 Sqmm for 3 pin, 15 Amps socket outlet on independent board with 4.00 sqmm multistrand copper earth continuity conductor as earth continuity conductor complete all as specified and directed.
M&L for point wiring complete with multi stranded copper conductor cable of size 1.5 sqmm PVC insulated unsheathed FRLS colour coded 1100 volts grade drawn in and including surface/ concealed stove enamelled medium grade ERW steel conduit of size 19/ 20mm dia or higher size with all fittings such as tees, bends etc. including PVC insulated unshearthed 1.5 sqmm multistranded copper conductor cable FRLS colour code cable 1100 volts grade for earth continuity for one light point controlled by one flame proof switch complete all as specified and directed.
All as per item No 45.00 here-in-before but with cable of size 2.5 Sqmm for 3 pin, 15 Amps socket outlet on independent board with 2.5 sqmm multistrand copper earth continuity conductor as earth continuity conductor complete all as specified and directed.
S&F switch piano flush type 5 Amps single pole one way complete all as specified and directed.
S &F switch piano flush type 15 Amps single pole one way complete all as specified and directed.
S&F socket outlet 3 pin, 5A, flush type complete all as specified and directed.
S&F socket outlet, flush type, multipurpose multi pin, 2 in one 3 pin, 5 Amps & 15 Amps, 230 volts, complete all as specified and directed.
S&F Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
S&F Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed.
S&F ceiling rose surface bakelite two to three terminals complete all as specified and directed.
S&F in replacement MCB SP 240 volts 6 to 32 Amps 'B' curve type all as specified and directed.
S&F in replacement MCB SPN 240 volts 32 Amps ‘B’ curve complete all as specified and directed.
S&F in replacement DB sheet metal enclosure double door for MCB’s company made, SPN 240 Volts 12 ways with IP 42 protection with 200 amps rated bus bars complete all as specified and directed.
S&F in replacement sheet metal enclosure for incoming MCCB and outgoing MCBs factory made double door, VTPN 415 volts 08 ways with 200 Amp bus bar with IP43 protection complete in all aspects all as specified and directed.
Supply, fix, connecting and testing MCCB four pole 100 Amps, 415 volts breaking capacity, 16kA with adjustable thermal and fixed magnetic setting conforming to IS/IEC 60947-2 including taking down the existing one complete all as specified and directed.
S&F factory made sheet metal enclosure single pole & neutral with a two pin & earth plug and socket etc complete with provision for one single pole 'B' series MCB 20 Amps 240 volts complete all as specified and directed.
S&F in replacement LED lights fitting channel and rod type) 4 feet long 1 x 18/ 20 W, 220V, AC decorative box type with driver, holder including LED tube rod connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F in LED light fitting 1x16 watt flame proof, CMRI certified recommended for gas/ vapour group of IIA & IIIB, zone 1 & 2 and IP 65 protection with die cast aluminum housing with heat resistatn toughened glass with LED tube light fixtures driver, holders, connector etc. Complete with all accessories prewired and inlcuding connection up with three cor flexible copper conductor cable with suitable size complete all as specified and directed by Engineer-in-Charge
S&F in repairs recess mounting LED slim ceiling light fitting extruded aluminium housing and milky diffuser suitable for 36W 2' X 2' ceiling cell of 36 watt complete all as specified complete all as specified and directed.
S&F in repairs LED bulk head luminaire 1 x 10W with IP 65 & heat resistance complete prewired complete all as specified complete all as specified and directed.
M&L for submain wiring complete with two runs of 6.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including rigid non metallic PVC conduit medium grade ISI marked 25mm external dia concealed in wall/ floor along with conduit fittings and accessories, fixed on ceiling with one run of 6.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring with conduit any type complete all as specified. Note: Two runs of 6.0sqmm multistranded cable and one run of 6.0sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
M&L for submain wiring complete with two runs of 4.0 Sqmm single core, multistranded, FR PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn through and including rigid non metallic PVC conduit medium grade ISI marked 25mm external dia concealed in wall/ floor along with conduit fittings and accessories, fixed on ceiling with one run of 4.0 Sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dolly including taking down existing submain wiring with conduit any type complete all as specified. Note: Two runs of 4.0sqmm multistranded cable and one run of 4.0sqmm cable as earth continuity conductor alongwith PVC conduit shall be considered as one unit length.
M&L taking down ceiling fan/ exhaust fan after dis-connecting the electric connection and keeping in safe custody and hanging the same after repairs to building including making connection from ceiling rose to connector of fan with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed.
M&L earthing complete with GI earth plate electrode of size 600mm x 600mm x 6mm thick buried directly in ground vertically with top edge of earth plate not less than 1.5m below normal ground level (depth of pit not less than 2.25m below normal ground level), earth plate surrounded from all sides by 15cm thick packed alternate layers of charcoal dust and common salt, electrode connections using galvanized iron wire of 4mm dia (8 SWG) by means of GI bolts, nuts, check nuts & GI washers and other end of earth lead connected to main switch board or main control board or test point or equipment, earth lead protected by galvanized iron pipe light grade (ISI marked) 20mm bore, alongwith watering pipe 20mm bore GI medium grade (ISI marked of specified make), funnel with wire mesh including all necessary excavation & earth work, PCC chamber in PCC (1:2:4) type B-1 and RCC cover all as shown in electrical plate No 3 of MES Schedule Part-I including testing on completion complete all as specified and directed.
Notes:- (i) Pit cover shall be 80mm thick pre-cast of RCC (1:1½:3) type A-1 reinforced with XPM not less than 4Kg/ Sqm. (ii) PCC Chamber shall be constructed 500mm away from the edge of earth pit. (iii) Rate shall include earth lead and protection pipe of length 7.5m, excess beyond 7.5m length required at site shall be measured and paid separately. (iv) Earth resistance should be less than 5 Ohm. In case the test results are not found below 3 Ohm, complete earthing will be redone without any extra cost to Govt.
Supply,fixing & testing AC timer digital supply 230 Volt AC, 50 hz( +/- 15%) Contact rating 30Amp at 230 volt for compressor and 5 amp at 230 V for alarm, potential free point to switch off the AC in case of fire for any type Split / window AC complete all as specified and directed. Make Creative Techonology Model no TT-02 Or equivalent in make comfort services/ RYB solution with same performance & specification as approved by GE.
S&F exhaust fan, flameproof steel body AC single Phase, 240V of size 300mm sweep with, blades and frame and louvers including cutting hole in brick wall, finishing work and 04 Nos 12 mm dia 150 mm long anchor fasteners including making electrical connections complete all as specified and directed.
Varindera And Varindera Construction
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .