Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Rejected-Technical | Rejected-Technical Technically Disqualified |
| 2 | Rejected-Technical | Rejected-Technical Technically Disqualified |
Tender Value
₹22.1 L
EMD Value
₹44,300
Closing Date
4 May 2026, 3:00 pmClosed
AGM(EM)
FCI Headquarters New Delhi
Supply, Installation, Testing and Commissioning of Split and Window Air Conditioners in Hostel Premises at Institute of Food Security, Gurugram (2nd Call)
2026_FCI_906252_1
EM/08/2025-26
Open Tender
Electrical Works
Item Rate
45 days
Institute of Food Security
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹44,300
19 May 2026
23 Apr 2026
5 May 2026
23 Apr 2026
4 May 2026
23 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying , Installation, Testing and Commissioning of Window type Inverter Air conditioners (1.5 TR with Inverter 5 Star BEE rating) complete with copper power cable upto 3 Mtr, wireless Remote, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing, cooling, dehumidification, air circulation, R-32/R-410A /R-407B Green Refrigerant with Scroll / rotary compressor with min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB), antifreeze thermostat on the coil as a safety feature, complete with fixing including T&P & labour etc as required complete in all respect as specified of following capacity. Sound level of up to 50dB inside the room is acceptable. The unit shall be in confirmation with IS 1391 Part-I 2023 and CPWD Specification. The system shall be able to deliver 100% of the rated capacity upto 42 0C. The system shall be able to operate up to 50 0C (out door ambient temperature). | |||||
| 2Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners Inverter Type - Cooling only 1.5 TR with 5 Star BEE Rating complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). | |||||
| 3Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners Inverter Type - Cooling only 2 TR with 5 Star BEE Rating complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). | |||||
| 4Uninstallation of window/ split Acs in all respect. | |||||
| 5Supply and Installation of additional copper pipe set (with nitrile insulations, wire) inside false ceiling/ underground/ recessed as required. | |||||
| 6Supply and installation of Split AC Wall stand along with fastner set as required on wall. | |||||
| 7Supply and fixing of Drain Pipe for the AC drain system as required | |||||
| 8Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required. | |||||
| 9Supply and installation of Stabilizer for the ACs along with all connections in all respect as per directions of engineer-in-charge. | |||||
| 10Supply and fixing of GI Tray under the window Acs in all respect as per directions of engineer-in-charge. | |||||
stage.html
html • 0.02 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.99 MB
tendoc.pdf
Tender Documents • 1.67 MB
BOQ_952566.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .