Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.2 LAccepted-AOC C 150 ADG P CHENNAI | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹44.8 L+₹5.1 L (12.8%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | L2 | Rejected-Finance BEING NOT L1 BIDDER | |
| 3 | L3₹45.9 L+₹6.2 L (15.7%)Rejected-Finance C 101 ADG P CHENNAI | L3 | Rejected-Finance BEING NOT L1 BIDDER | |
| 4 | L4₹47.6 L+₹7.9 L (19.9%)Rejected-Finance 109 D ALLAI SALT COMPOUND OLD LAKSHMI THEATRE KRISHNAPURAM COONOOR 643102 THE NILGIRIS | COONOOR | THE NILGIRIS | TAMIL NADU | 643102 | L4 | Rejected-Finance BEING NOT L1 BIDDER |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
23 Jun 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE DSSC
GE DSSC WELLINGTON BARRACKS-POST, WELLINGTON, THE NILGIRIS, TAMIL NADU,PIN-643231
UPGRADATION OF SQUASH COURT AT GORKHA HILL AT DSSC WELLINGTON
2022_MES_524740_1
8242/E8
Open Tender
Civil Works
Item Rate
120 days
WELLINGTON
PLEASE REFER TENDER DOCUMENTS AND NIT
8 documents required · 8 mandatory
₹500
GE DSSC WELLINGTON
₹84,000
Yes
5 Jul 2022
18 May 2022
25 Jun 2022
18 May 2022
23 Jun 2022
1 Jun 2022
60 days
Amount
Taking down wooden boarding of any size & thickness fixed on floor/wooden scantling with nails/screws all as specified and as directed.
Taking down framed wooden scantling 40 sq. cm and over in section fixed on PCC floor/concrete blocks with or without nails, brads, spikes, etc. all as specified and as directed.
Demolition of unreinforced plain cement concrete in ground floors and pavings n. exc 15 cm thickness (below or above ground level) and removing debris from site all as specified and as directed.
M&L for providing and injecting chemical emulsion for Post construction Antitermite treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 liters per linear meter including drilling and plugging holes etc. in apron complete all as specified and as directed.
M&L for providing and injecting chemical emulsion for Post construction Antitermite treatment of soil under existing floors using emulsion @ one liter per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc all as specified and as directed.
Brushing neat cement slurry with 3.0kg of cement per sq. meter prior to laying of concrete for bonding between layers of old/new concrete surfaces all as specified and as directed.
M&L for plain cement concrete type E- 2, (1:4:8) using 40mm graded stone aggregate 100 mm thick as in sub base of floors and the like finished even and fair to receive the topping layer complete all as specified and as directed.
M&L for plain cement concrete type B-1 (1:2:4) using 20mm graded stone aggregate 75 mm thick as in floors and the like finished even and smooth without using extra cement, to an uniform layer in level, for receiving the wooden floor system for Squash court all as specified and as directed.
Supply, installing and finishing of air-cushion wooden hardwood non-slippery sports flooring system for Squash courts confirming to the requirement of WSF (World Squash Federation) consisting of 'L-MAC PAVE' CX 14B Series or equivalent with the following members & specification:-
(i) The playing surface comprises of Surface Board kiln seasoned imported Hard Maple (Syca More) or White Oak solid wood surface board of finished size 22 mm thick with 60 to 70 mm width and in random length in tongue & groove shape, joints to be supported by12 mm thick Gum Wood Counter Board over under frame battens. 1mm noise reducer, 10mm rubber. The edges of the board shall have a finger lock grove and the bottom side shall have air pass groove and applied with polyurethane lacquer. The boards shall be secret-nailed/screwed to under frame battens and the end of each board is supported by batten, nailed/screwed through the tongue only and shall lock the groove of the adjoining board. The edges of the board shall be locked by inserting the wooden fingers through the edge groove and fixed with suitable adhesive. An expansion gap of 6-9 mm shall be left open at junction of wall & floor all around. A vapour barrier of 6ml (600 micron) thick will be placed on the leveled IPS sub-floor before laying under the frame. (ii) The under frame Batten System comprises of commercial quality Fir/Spurce/Pine wood kiln seasoned wood runners of 39 mm (H) x 45 mm (H) treated with anti-termite solution and fixed on the bottom side with 10 mm thick air cell cushioning pads by staple through the wings at 300 mm c/c /rubber pads. 1 mm Noise reducer shall be provided.
(iii) A vapour barrier of 6 mil (600 micron) thickness shall be placed on the already leveled and cured PCC floor IPS sub floor system before laying the under frame Batten system. The under frame Battens having air cell cushioning pads at bottom shall be placed on the vapour barrier in perfect level at 300 mm c/c in one direction only. The boards shall be placed and nailed/screwed on the the battens in the other direction only. (Note: PCC floor IPS sub floor system is to be measured and paid separately against the corresponding items catered in the above schedule. The Difference in height between IPS floor system & top playing surface shall be 85 mm, leveled to a tolerance of 3 mm.) (iv) After the installation of floor system, the floor shall be machine sanded in uniform level (permissible tolerance of 3 mm with a 3000 mm straight edge as per WSF regulations) and finished with non-skid Polyurethane lacquer. Game Line marking on the wooden floor shall be carried out in required colours as per WSF regulations to the dimensions as specified prior to the application of finishing coat. Note:- 1. The wooden floor system shall be laid after a min. period of 21 days after the concrete floor system is laid including curing. 2. The timber used for surface boards shall be imported Hard Maple or Oak wood kiln seasoned. 3. The varying colour of the wood due to its natural characteristics shall not be considered as defect. 4. All timber shall be free from loose knots, bee or borer holes, splits, cracks & fungal attack. 5. All timber shall be kiln seasoned with moisture content approx 10 to 12%.
Taking down cement or cement lime plaster of any thickness and any description on brick or stone wall etc incl racking out joints, hacking for key scrubbing down with water etc and removing debris from site all as specified and as directed.
Demolition of brick work / pre cast concrete article / stone masonry built in cement mortar all as specified and as directed.
M& L Rendering in CM (1:4) avg 25 mm thick on stone masonry or other than fair faces of brick work surfaces of wall finished even and smooth without using extra cement all as specified and as directed.
M& L Rendering in CM (1:6) 20 mm thick on fair faces of brick work surfaces of wall finished even and smooth without using extra cement all as specified and as directed.
M& L Rendering in CM (1:4) 20 mm thick in cement mortar 1:4 using integral water proofing compound on fair face of brick/concrete surfaces and finished even and smooth without using extra cement all as directed.
M& L Rendering in CM (1:4) 5 mm thick on fair faces on ceiling surfaces of wall finished even and smooth without using extra cement all as specified and as directed.
M & L for Hard Plaster System for Squash Court on play area walls confirming the specification laid down as per WSF ( World Squash Federation). The system consists of a total coating thickness of 12 to 13mm thickness in two layers of base coat 9 to 10mm and top coat 3mm thicness. The Hard plaster used is as per ANSI A118.4-1999 and A111.1-1999, provides a shear bond (28 days cure) of 300 PSI (2.0 MPa) and compressive strength of 2750 PSI. The water based nonflammable binder used is specially designed to create an everlasting bond between the two substrates. Non-Structural wire mesh reinforcement of glass fiber is added to the mixture to give further strength to the system.
Mixing ratio for first coat of Comp A : Comp B : Comp C shall be maintained as 1:1/4:1 in 5-6 Ltrs of water. Mixing ratio for second coat shall be 1:1/4:0.5 in 5-6 Liters of water for second coat. Enamel Painting over the hard plaster & Game Line Marking on the wall shall be carried out in required colours as per WSF regulations to the dimensions as specified. Comp A - Hard plaster Comp B : Binder, Comp C : Additives shall be all as per WSF Specification Note : (i) Work shall be carried out by specialized authorised agency as approved by WSF and Sports Authority of India only. (ii) Warranty for the Hard plaster shall be for two years from the date of completion of the work. (iii) Hard plaster for squash court shall be incorporated only after getting approval from GE.
M/L Preparation of new surfaces of walls by sanding the surface and applying one coat of wall paster primer (water thinable / solvent thinable), two coats of Acrylic wall putty for making the surface smooth and even including sanding each layer to receive next new layer, one coat of wall plaster primer and applying two coats of plastic emulsion to be applied by approved applicator of the manufacturer of the paint and all as specified and as approved.
M&L for preparation of new surfaces of walls and applying with white putty and making the surface to an even &smooth finish, rubbing with sand paper of different grade etc and applying two coats of tractor emulsion or Oil bound emulsion distemper over a coat of primer to be applied by approved applicator of the manufacturer of the paint and all as specified and as approved.
M&L for complete removal of existing treatment on surfaces of wall &applying with white putty and making the surface to an even &smooth finish, rubbing with sand paper of different grade etc and applying two coats of tractor emulsion or Oil bound emulsion distemper over a coat of primer to be applied by approved applicator of the manufacturer of the paint and all as specified and as approved
M & L for Preparation of old decorated surfaces of walls, cornices etc including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots etc and applying three coat of white wash on wall complete all as specified and as directed by Engr-in-Charge
M & L for Preparation of old decorated surfaces of walls, cornices etc including brooming down or steel wire brushing, scraping down smoke soot, moulds, moss and efflorescent salt and trading oil and greasy spots etc and applying three coat of white wash on ceiling complete all as specified and as directed by Engr-in-Charge
M& L for applying three coats of white wash on walls including preparation of newly plastered surfaces of wall complete all as specified and as directed by Engr-in-Charge
M&L for Preparing newly plastered surfaces on external walls and applying one coat of exterior wall putty for smoothness, one coat of exterior wall primer and two coats of Exterior Emulsion anti-algal weather proof paint complete all as per manufacturer instruction as directed.
Complete removal of existing treatment on external walls by wire brushing, crack filling & Bio-wash to fight microbial growth and applying one coat of exterior wall putty for smoothness, one coat of exterior wall primer and two coats of Exterior Emulsion anti-algae weather proof paint complete all as per manufacturer instruction as directed.
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (any shade) over a coat of red oxide zinc chrome primer all as specified and directed.
Taking down wooden boarding of any size & thickness fixed on floor/wall with screws and removing from site all as specified and as directed.
Supply & installing 'Tin' made of white melamine faced particle board or other sheet material with void behind to make hollow sound when struck by ball. The 'Tin' is fixed with splayed top batten 'Board' at top and bottom cover moulding for floor mounting at bottom. The total height of 'Tin' including 'Board' from FFL is 480 mm & length of 6400mm. The 'Board' colour matches the play lines - red and bottom cover moulding is white. Note:- Ventilation holes of specific pattern to be drilled at locations where air holes are provided at the bottom at 'Tin' location as required and as per WSF specification. Ant strengthening if required at ventilation location may be done with metal sheets and the same is deemed to be included in the above rates.
Taking door frame with shutter (without taking off shutters from the frames) n. exc. 1.5 Sqm each all as specified and as directed.
Taking door Chowkhats or frames with shutter (without taking off shutters from the frames) exc 1.5 sq. m but n exc 4 sq. m each all as specified and as directed.
Taking door Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each all as specified and as directed.
M&L for Forming jambs, etc. to openings (to foregoing item) in cement mortar 1:4 including cutting toothing and properly bonding into old work also facing, jointing and pointing to match existing work complete all as specified and as directed.
M&L for providing UPVC Door with Shutters. The construction profile for UPVC Door shall be overall frame sectional size 60 x 58 mm with wall thickness 2.70 +/- 0.2 mm extruded sections. The corners shall be plastic welded. The hinge side vertical outer frame shall be reinforced with galvanised steel profile of wall thickness 1.2 mm +/- 0.2 mm. The door shall be fixed to walls using 8 mm dia 80 mm long MS screws minimum 3 Nos on each side. The glazing shall be fixed to door frame with UPVC standard beadings of sectional size 24.05 x 16 mm & 2 mm thick. The bottom portion of door shutter shall be provided with UPVC board 5 mm thick & 1 mtr in height and the balance shall be glazed excluding the shutter frame area. The shutter shall be fixed to frame using 3 nos of 3D hinges. The Door shutter shall be provided with 12 mm thick sheet glass & 5 mm UPVC board with EPDM rubber gasket, one mortice lock with powder coated handles and two numbers powder coated MS tower bolts complete all as specified & as directed.
S & F Toughned glass door 12 mm thick fixed in position with suitable SS fittings & locking arrangements, 600mm size stainless steel handles etc all as specified and as directed.
S & F 12mm thick Toughned glass to be fixed in position with suitable SS fittings etc all as specified and as directed.
Supply and fixing Stainless steel railing made of any dia/gauge and grade 304 fixed in vertical and horizontal position in railing cut to length required welded and moulded for fixing of 12 thick plain toughned glass complete all as specified and as directed.
S&F 12 thick plain toughned glass fixed to SS railing using suitable stainless steel fixing arrangements in opening of any size with appropriate screw/clamps and ends caps/ base caps, etc. all as specified and directed by manufacturers instruction including moulding all as specified
M&L for providing UPVC Casement window with outside openable Shutters having UPVC Frame & shutter with friction hinges 300 x 19 x 1.9 mm with Shutters. The construction profile for UPVC Casement Window shall be overall frame sectional size 60 x 58 mm with wall thickness 2.70 +/- 0.2 mm extruded sections. The corners shall be plastic welded. The hinge side vertical outer frame shall be reinforced with galvanised steel profile of wall thickness 1.2 mm +/- 0.2 mm. The window frame shall be fixed to walls using 8 mm dia 80 mm long MS screws minimum 3 Nos on each side. The glazing shall be fixed to window shutter frame with UPVC standard beadings of sectional size 24.05 x 16 mm & 2 mm thick. The shutter shall be fixed to frame using 2 nos of friction hinges of size 300 x 19 x 1.9 mm. Each shutter shall be provided with 12 mm thick sheet glass with EPDM rubber gasket, one powder coated casment window handle and one no powder coated Casement lock complete all as specified & as directed.
Demolition of brick tiles or terracing tiles, single layer on roofs including removal of existing water proofing treatment of any description and removal of debris to out side MD land complete all as specified and as directed.
M&L for laying 3mm thick APP modified water proofing membrane weighing not less than 3.6 Kg/Sqm, reinforced with non woven polyster matt black finished weighing not less than 100 gm/Sqm having softening point not less than 140 degree celsius longitudinal tensile strength not less than 300 N/Sqm, side lap 10cm & end lap 15cm over a coat of bitumen primer @ 0.40 Ltr/Sqm and finished with aluminum paint @ 0.10 Ltr/Sqm all as per manufactures instruction and as directed by Engr-in charge. Note : The work shall be carried out by authorised applicators of manufactures.
Material and labour for providing cement concrete type B-0, 1;2;4 (12.5mm graded agregate) avg 30mm thick in floors,roofs etc (for roof padding) finished even and fair all as specified and as directed
Rendering 10mm thick cement screed in cement mortar 1:3 mixed with liquid water proofing compound FOSROC's complast 421 IC @ 130ml per bag of cement including a bonding coat of FOSROC's Nito bond AR cement slurry (or) Equivalent as per manufactures instruction on roofcslab/ floor complete all as specified (liquid water proofing compound are measure seperately)
S&F Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top and screwed lid type) FDA grade material of capacity 1000 litres hoisted and fixed in position. Dismantling existing tanks exc. 250 lit & n. exc. 500 litres capacity and as specified in SSR Part I as specified and as directed.
Supply and fix 25mm bore, Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule complete all as specified and as directed.
Supply and Fix in repairs Gun metal globe or gate valve of size 25mm bore confirming to IS 778-1984 with iron wheel head, screwed both ends for GI pipe including all fittings / fixtures like nipple, union etc., complete all as specified and as directed.
S&F mild steel works as framed roof members, rafters, purlins, trusses, connecting plates, cleats, etc. including distance pieces conforming to Fe-410-W(Gde E-250) quality-A complete all as specified and as directed.
Excavating in trenches n.exc. 1.50 m wide and not exceeding 1.50 mtrs in depth for foundation etc and getting out in hard / dense soil all as specified and as directed.
Returning filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm all as specified and as directed.
Removing of surplus excavated materials exc 250 m but n.exc 500m depositing where directed at a level n.exc 1.5 m above the starting points all as specified and as directed.
Material and labour for plain cement concrete 1:4:8type D2, using 40mm graded stone aggregate as in foundation, filling and mass concrete all as specified and as directed.
M&L for Precast cement concrete solid building blocks Type C1 (1:3:6) using 20 mm graded aggregate, exc 10 cm width set in CM 1:6 all as specified and as directed
M&L for plain cement concrete 1:2:4, type B1, using 20mm graded stone aggregate as in coping including necessary form work all as specified and as directed.
Material and labour for 15 mm thick rendering in cement mortar 1 : 4 on brick / concrete surfaces, finished fair and even without using extra cement all as specified and as directed.
Surfaces excavation n exc 30 cm deep and averaging 15cm deep and getting out in hard/dense soil.
M&L hardcore of gauge n.exc 63 mm deposited, spread & levelled in layers n. exc 15 cm thick, watered & rammed to a true surface with broken stone or boulders complete as specified and as directed.
Dismantiling of floor hearth wall tiling or terrazzo flooring including cement mortar bedding removing debris off the premises complete all as specified and as directed.
M&L glazed ceramic coloured tiles (600x300) x 7mm thick on vertical surfaces such as skirting, dados and risers to steps etc. set and jointed neat cemet slury and pointed in coloured cement to match the colouring tile all as specified and as directed.
M&L Chequered cement concrete coloured tiles 20cm x 20cm x 25mm thick set jointed and pointed in neat cement slury with grey cement pigment complete all as is specified.
M&L for screed bed or bedding layer of mortar 20 mm thick for laying floor finishes in CM 1:4 complete all as specified and as directed.
M&L 75mm thick Plain Cement Concrete type C-1, 1:3:6 (20mm graded stone aggregate) as in floors, plinth protection etc. finished even & fair without using extra cement complete as specified and as directed.
S&F 18/19mm thick Particle board, exterior grade prelaminated both sides with decorative choice lamination, fixed with nails/ screw screws to timber frame work including liping work teak wood beading 6mm thick comple all as specified and directed
S&F Continuous (Piano) hinges brass, bright finish width of flaps 40mm all as specified and as directed.
S&F brass knobs 35-40mm dia complete all as specified and directed
S&F ball catches with 8mm dia steel ball and bras body and striking plate including letting in and fixed complete all as specified and directed
Demolition of cement concrete (reinforced ) of any description and in any postion not otherwise spcifically provided etc. exc 15cm thickness (below or above ground level) and removing debris from site complete all as spcified and as directed.
Taking up or down steel tubing 20mm bore and connections taken on credit complete all as specified and as directed.
Taking up or down steel tubing 25mm bore and connections taken on credit complete all as specified and as directed.
Supply and fix Galvanised steel water tubing medium grade 20mm bore conforming to IS specifications and ISI marked with all fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc fixed on walls/ceiling or laid in floors etc., complete all as specified and as directed.
Supply and fix Galvanised steel water tubing medium grade 25mm bore conforming to IS specifications and ISI marked with all fittings such as bends, tees, unions, elbows, connecting pieces, plugs, sockets etc fixed on walls/ceiling or laid in floors etc., complete all as specified and as directed.
M&L for TMTbars,10mm dia and over cut to length,bent to shape required,including cranking, bending spirally for hooping for columns,hookingends and binding with mild steel wire (anealed) not less than 0.9mm dia or securing with clips all as specified.
M&L for fair finished flat surfaces of concrete formwork to soffits of suspended slab such as roof,floorslabs,landing and similar work not exceeding 200mm thick all as specified and as directed.
M&L for fair finished flat surfaces of concrete formwork to soffits of beam or roof beams, lintels, cantilevers etc. and complete all as specified and as directed.
M&L for reinforced Cement Concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in Beams and columns in floors roofs,landing,balconies,canopies,deck slab and in shelves and like complete as specified and as directed.
M&L for providing, erecting, removing and taking away using steel tubular vertical props upto 10 mtrs height, horizontal members supporting and other necessary members, nuts, bolts, clamps, etc. as in scaffolding complete all as specified. Note : 1. The measurements shall be taken for the vertical height x length of the scaffolding erected. 2. The scaffolding shall be retained till the work is complete in all respects, including curing & finishes, etc. After completion of work, the scaffolding shall be dismantled and removed out of premises all as directed.
Material and labour for chipping of spalled cracked concrete up to minimum depth of 25 mm behind the reinforcing bars in columns, beams, ceiling, chajjas, fins and facias etc., remove loose concrete particles and cleaning of rusted reinforcement bars with wire brush, emery paper etc., remove all traces of rust, scales any dust, oil, paint, grease by cleaning with water jet, expose fully any corroded steel and remove all scale and corrosion and prepare the structure for the application of micro concrete for an average thickness of 50mm as per standard specification and manufacturer's instruction complete all as specified and as directed.
Supply, fabricating and placing in position of new TMT bars of any dia conforming to Fe-550D by welding or inserting by drilling holes and embeded in epoxy grout bonding agent of hilti or equivalent for all existing reinforcement repair works in any position wherever necessary complete all as specified and as directed by Engineer-in-charge. Note: (a) The lap provided shall be 15 cm on either side of bar which has lost its sectional area. (b) The unit rate quated shall be deemed to include the cost of epoxy grout bonding agent.
M&L for exposing the existing reinforcement bars fully in the repair area and remove all loose scales and corrosion deposits using Dr. Fixit Rust Remover or equivalent of other specified makes on effected steel surface by brush with coverage of 18sqm/Ltr and applying protective zinc primer using Fosroc Nitoprime Zincrich or Dr. Fixit Zinc primer or equivalent on bars of dry thickness 40 micron (wet thickness 130 micron) with approx coverage of 7.40 Sqm/litre before concreting all as specified and as directed.
Supply & Fixing of slurry tight formwork which shall not deform or leak due to pressure of micro concrete shall be fabricated and erected in position. Provision shall be made for a suitable feed hopper for pouring in the micro concrete in the formwork. The form work shall be coated with Nafuplan UST liquid for steel surfaces, Nafuplan-K for wooden surfaces or Fosroc Reebol mould releasing agent or equivalent releasing agent prior to final fixing in position as per manufacturers instruction. Proper supporting arrangements to be made for keeping the shutter in correct line and length complete all as specified and as directed by Engineer-in Charge.
M&L for stocking sufficient quantity of micro concrete material comprising 10 mm down graded aggregate chips, pouring in a continuous operation with a grout/ concrete mixer of low speed heavy duty dram fitted with suitable paddle shall be kept ready and chips slowly mixed in the dram thoroughly in a forced action. The mixed materials shall be placed immediately in to the position formwork continuously without any time gap complete for an average thickness of 40 - 50 mm including finishing the exposed surface even and smooth complete all as specified and as directed by Engineer-in charge. Note: (a) The micro concrete shall be Shikacrete-114 AE or Dr. Fixit Micro Concrete or equivalent of Manufactured by Fosroc or Bouchemie. (b) The unite rate quoted shall be deemed to include the cost of micro concrete materials,admixtures,lead and lift and T&P required for pouring or pumping etc.,
Taking down carefully old existing Un-Serviceable Al/Copper batten/surface conduit point wiring (light/exhaust fan/socket/call bell/ Power point) complete including (fittings and fixtures such as switches, ceiling roses, shades, brackets, sockets, holders, light fittings, call bells, Fluorescent tube light fitting) removing the Un-Serviceable retrieved materials from site making good the disturbed surfaces of walls/floors/ ceilings etc. complete all as specified and directed by Engr-in-Charge.
Taking out unserviceable PVC insulated/sheathed sub main wiring with 2 single core aluminium conductor cable of size upto 10 Sqmm on wooden batten/PVC conduits complete with battens/conduits and shall be removed from site and making good the disturbed surfaces of wall complete all as specified and directed by Engr-in-Charge.
M&L for point wiring with 1.5 Sq mm, PVC insulated, FRLS,single core, copper conductor cable, 1100 Volt grade, multi stranded drawn through and including medium grade Rigid non metallic PVC conduit concealed in wall/ceiling/roof etc with all necessary accessories for the following controlled by one switch with and including continuous 1.5 Sqmm PVC insulated single core copper conductor cable earth continuity conductor connected to common earth and earth dolly, in the modular flush boxes etc. complete all as specified and directed by Engr-in-Charge. Note: (i) The wiring shall be done in proper color coding using red,yellow,blue for phases, black for neutral and green for earth. (ii) The cost of cutting chases and making good the disturbed surfaces is deemed to be included in the unit quoted rates.(iii) Modular flush boxes will be measured & paid separately. Make of cable: Havells/Finolex/polycap. Make of conduit: Precision/Bajaj Plast/Modi/presfit. a) One light/fan/call bell point controlled by one switch.
b) One 5 amps 5 Pin socket outlet on independent board
All as per Item No-82 above but with PVC insulated copper conductor cable of size 2.5 Sqmm and 2.5 Sqmm for earth continuity conductor for 16A switch socket. Make of cable: Havells/Finolex/polycap. Make of conduit: Precision/Bajaj Plast/Modi/presfit. Note: (i) The wiring shall be done in proper color coding using red,yellow,blue for phases, black for neutral and green for earth (ii) The cost of cutting chases and making good the disturbed surfaces is deemed to be included in the unit quoted rates.(iii) Modular flush boxes will be measured & paid separately.
M&L for sub main wiring with two single core, multi stranded, PVC insulated, 1100 Volt grade, FRLS cable with multi stranded copper conductor of size 6 Sq mm drawing through and including medium grade non metallic rigid PVC conduit concealed in wall/ceiling/roof etc. including continuous PVC insulated copper conductor single core earth continuity conductor of size 6 Sqmm connected common earth complete all as specified and directed by Engr-in-Charge. Make of cable: Havells/Finolex/polycap. Make of conduit: Precision/Bajaj Plast/Modi/presfit. Note:(i) 3 runs of 6 Sqmm cable and one run of conduit shall be measured as one unit length (ii) The wiring shall be done in proper color coding using red,yellow,blue for phases, black for neutral and green for earth (iii) The cost of cutting chases and making good the disturbed surfaces is deemed to be included in the unit quoted rates
S&F Modular type socket outlet 2 in 1, 6/16 Amps all as specified and as directed. Cat No ACVKCWW163 Verona of Crabtree or techno-commercially equiv In Legrand/Anchor Roma.
S&F in repairs Modular type switch single pole 16 Amps one way all as specified and as directed. Cat No ACVSXXW161 Verona of Crabtree or techno-commercially equiv In Legrand/Anchor Roma.
S&F in repairs Modular type switch single pole 6 Amps one way all as specified and as directed. Cat No ACVSXXW101 Verona of Crabtree or techno-commercially equiv In Legrand/Anchor Roma.
S&F in repairs Modular type socket out let 6 Amps 2/3 pin combined 2 module all as specified and as directed. Cat No ACVKSWW065 Verona of Crabtree or techno-commercially equiv In Legrand/Anchor Roma.
Supply & Fixing and concealing modular metal flush box suitable for fixing switches/sockets of 1 modules all as directed.
Supply & Fixing and concealing modular metal flush box suitable for fixing switches/sockets of 3 modules all as directed.
Supply & Fixing and concealing modular metal flush box suitable for fixing switches/sockets of 4 modules all as directed.
Supply & Fixing and concealing modular metal flush box suitable for fixing switches/sockets of 12 modules all as directed.
Supply & Fixing modular cover plate suitable for fixing switches etc of 1 modules all as directed.
Supply & Fixing modular cover plate suitable for fixing switches/sockets of 3 modules all as directed.
Supply & Fixing modular cover plate suitable for fixing switches/sockets of 4 modules all as directed.
Supply & Fixing modular cover plate suitable for fixing switches/sockets of 12 modules all as directed.
Note for item No 90 to 97:- The make/model of modular metal flush boxes & modular cover plates shall be same as that of modular switches & sockets.
S&F of ceiling rose surface mount PVC/Polycarbonate, isolated body with face bakelite two/three terminal complete all as specified and directed. Make: Havells/CG/Anchor
S&F IP>=20, Class I, Wall mounted 4 feet LED lighting fixture with integrated electronic driver & polycarbonate difuser complete with all accessories, prewired, 20 W with min 1800 lumens,≥ 5700K, PF>=0.90, CRI>=80 and connecting of flexible wire twin core from ceiling rose to fitting in flexible conduit all as specified and directed by Engr-in-Charge. Make: Luker Cat No:LT5M20 or techno-commercially equiv in Philips/Jaguar
S&F IP>=20, Class I Wall mounted 2 feet LED LED lighting fixture with integrated electronic driver & polycarbonate diffuser complete with all accessories, prewired, including 10 W with min 900 lumens, ≥ 5700K, PF>=0.90, CRI>=80 and connecting of flexible wire twin core from ceiling rose to fitting in flexible conduit all as specified and directed by Engr-in-Charge. Make: Luker Cat No:LT5M10 or techno-commercially equiv in Philips/Jaguar
S&F IP >= 66,IK>=07, Class I Environment friendly, energy saving, surface mounted, decorative bulk head edge lit LED luminaire 10W with min 800 lumens made of pressure die cast aluminium housing with suitable fixing arrangement complete with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size complete all as specified and as directed. Make : Havells, Cat no HEXAFT10WLED857SSYMBOPC or techno-commercially equivalent in Philips/Jaguar
S&F Decorative wall mounting fixture 14W, white, IP>=20 with aluminium die cast body with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size in flexible conduit all as specified and as directed. Make: Cat No LWL112-2 of Luker or techno-commercially equivalent in Philips/Jaguar.Note: The cost of making good and matching to the existing surface is deemed to be included in the unit quoted rates.
Supply, install, testing & commissioning of Exhaust fan, PVC body with automatic back shutter louvers 250 mm sweep, 1280 RPM or more, Air Delivery not less than 860 CMH, single phase, 240 Volts, AC, 50 Hz and connecting up complete including louvers and provision of cable 3/2 core of suitable size from ceiling rose to fan in flexible hose and making of suitable sized hole in the wall/existing window/ventillator etc. for fixing of the exhaust fan & making good the disturbed surfaces (if any) complete all as specified & as directed. Make : Havells, Cat No: Ventil Air - DX White or techno-commercially equivalent in Usha/Crompton. Note :- (i) The cost of making hole in walls/other surfaces & making good the disturbed surfaces incl any framework/cement work/wood work/welding work etc. required for proper fixing of the exhaust fan & matching to the existing surface is deemed to be included in the unit quoted rates.(ii) Old unsv Exhaust fans should be handed over to MES stores.
S&F IP>=65, IK>=07, Class I, Suspension/Side etc mounted highbay LED light complete with all accessories, prewired, of rating 120 W with min 15000 lumens ,5700 K, with PDC housing and polycarbonate diffuser, suitable for focusing the squash court at the height of 7 mtrs (Approx) from FFL including necessary electric connection & fixing arrangement with & incl suitable size/Nos of bolts,nuts,washers etc all as complete inconsultation with the OEM and inbuilt electronic driver & high brightness LED all as directed by the Engr- in- charge. Make: Havells Cat No: SAUCERGENXPROHBP120WLED757P90DBOLT G or techno-commercially equiv in Jaguar/Philips. Note : (i) The quoted rate is deemed to be inclusive of use/hiring/rent including transportation of aluminum tower ladders/Scaffolding arrangements (if any) required for successful execution of the complete work/Job. (ii) All safety precautions to be taken by the contractor for labour employed at the site. (iii) Design/Drawing/BOM of the lighting design/scheme got to be obtained from OEM & the same is to be approved by GE before placing the final order.
S&F IP>=66 IK>=07, Class I, Suspension/Side etc mounted floodlight LED light complete with all accessories, prewired, of rating 70 W with min 7000 lumens ,5700 K, with aluminium di-cast body and polycarbonate diffuser including necessary electric connection & fixing arrangement with & incl suitable size/Nos of bolts,nuts,washers etc all as complete inconsultation with the OEM and inbuilt electronic driver & high brightness LED all as directed by the Engr- in- charge. Make: Havells Cat No: JETA PRO70 or techno-commercially equiv in Jaguar/Philips. Note : (i) The quoted rate is deemed to be inclusive of use/hiring/rent including transportation of aluminum tower ladders/Scaffolding arrangements (if any) required for successful execution of the complete work/Job. (ii) All safety precautions to be taken by the contractor for labour employed at the site.
S&F MCCB, 4 pole,63-80A rating (Ics=100% of Icu),415Volts,25 KA Breaking capacity with adjustable thermal and fixed magnetic setting complete all as directed by the Engr-in-Charge.Make: Legrand, Cat No 4200 53 or techno-commercialy equiv in L&T/ABB. Note: The cost of cutting/grinding etc to match the MCCB with the existing TPN MCCB DB is deemed to be included in unit quoted rates.
S & F SPN DB, 8 Way IP43, IK09, Metal double door type 240 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed by Engr-in-Charge.Make: L&T, Cat No: DBSPN008DD or techno-commercially equiv in Legrand/Siemens. Note:- (i) The cost of making good the disturbed surfaces is deemed to be included in the unit quoted rates.
S & F SPN DB, 12 Way IP43, IK09, Metal double door type 240 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed by Engr-in-Charge.Make: L&T, Cat No: DBSPN012DD or techno-commercially equiv in Legrand/Siemens. Note:- (i) The cost of making good the disturbed surfaces is deemed to be included in the unit quoted rates.
S&F Miniature circuit Breakers, SPN,C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge.Make:L&T/Legrand/Siemens
S&F Miniature circuit Breakers, SP,C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge Make:L&T/Legrand/Siemens
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25mtrs deep below ground level) with top edge of plate not less than 1.5mtrs below normal ground level, connected to GI wire of size 4mm by means of bolts,nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 3 connected to earthing test point on completion with and including 15mm bore medium grade GI protection pipe (upto 7.5mtr long) for earth and 20mm GI medium grade for watering including PCC chamber pit & cover with suitable lifting hooks, with funnel, wire mesh, common salt, charcoal filling, necessary excavation and earth work in any type of soil complete all as specified and directed by Engr-in-Charge.Make of pipe-Tata/Jindal/Prakash.
M&L for conceal the existing MCCB DB flush to wall & making good to the disturbed surface incl matching with the existing complete all as specified and directed by Engr-in-Charge.
Supply and laying light grade GI Pipe (ISI Marked) of 50mm dia for cable protection to be fixed on wall with necessary clamps or in road crossing, complete all as directed. Make: TATA/Jindal/Prakash Note: Rate qouted shall be inclusive of MS clamps of required size.
M & L for cutting the existing hard standing/ PCC/ WBM road at a depth not less than 45 cm and 25 cm in width for passing of cable through GI pipe, returning filling in, complete including finishing the surfaces by providing 25 mm thick cement concrete type B-1 (1:2:4) using 20 mm grade aggregate, bottom filled with excavated earth and remain finishing to a uniform smooth surface complete all as specified and directed.
Sree Constructions
ACE PROMOTERS
K.AYYAPPAN
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .