Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹41.8 L+₹70,933 (1.73%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹44.5 L+₹3.4 L (8.27%)Rejected-Finance 39 40 DASHMESH MARKET CIVIL GURUDWARA LINE PORT BLAIR 744 101 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹45.0 L+₹3.9 L (9.50%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹45.7 L+₹4.6 L (11.1%)Rejected-Finance FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L5 | Rejected-Finance Not being L1 |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
14 Aug 2020, 6:00 pmClosed
GE UTILITY SECUNDERABAD
GE UTILITY, MUDFORT, SECUNDERABAD-500003
REPAIRS RENEWAL OF STREET LIGHTS, LT CABLES, CAPACITOR PANELS, EARTHINGS, OH LINES AND CONNECTED WORKS AT DGQA COMPLEX UNDER AGE EM.II OF GE UTILITY SECUNDERABAD
2020_MES_364232_1
GE(U)/SEC/TOKEN/28 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
SECUNDERABAD
As per NIT
6 documents required · 6 mandatory
₹500
GE UTILITY SECUNDERABAD
₹99,000
Yes
7 Dec 2020
27 Jul 2020
17 Aug 2020
27 Jul 2020
14 Aug 2020
8 Aug 2020
Amount
Taking down/out unserviceable UG Cables of any Cross Sectional Area and Connections including Pipes, Bricks, etc. of any descriptions, laying in Trenches and/or fixing with Walls/Poles including Segregating of Serviceable Materials viz cable, Bricks, Pipes, etc. and keep in Safe custody for re-use, complete all as specified and as directed.
Supply and lay in trenches/fixed to walls/poles etc connecting buy using lugs and commissioning XLPE insulated and PVC sheathed heavy duty LT 1100 Volts grade armoured under ground cable with aluminium conductor of 2 Core 10 Sqmm COMPLETE all as directed. Make : Havells/Finolex/POLYCAB/KEI Note :- Earth work excavation, sand cushioning and brick protection shall be measured and paid separately.
All as per item no:02 above but 4 Core 10 Sqmm
All as per item no:02 above but 4 Core 16 Sqmm
All as per item no:02 above but 3.5 Core 25 Sqmm
All as per item no:02 above but 3.5 Core 50 Sqmm
All as per item no:02 above but 3.5 Core 95 Sqmm
Relaying of LT cable of size10sq mm to 120 Sqmm 2/3.5 core after carrying out necessary Repair such as joining with Epoxy joint and laid with sand Cushioning and brick protection and making connection By using Lugs all as specified and directed by ingr in charge. Note: ( Earth work , sand Cushioning, brick protection, Lt Joints shall be measured and paid separately under Relevent Item)
Supply and lay GI tubing , 100 mm bore light grade for cable protection at road crossing / on poles/ fixing of post top lantren and tubing sealed at both ends after laying the cables complete all as directed by Engineer-in-Charge. Make :- ISI
All as per item no:9 above but 80 mm bore
All as per item no:9 above but 50 mm bore
All as per item no:9 above but 40 mm bore
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 35 sqmm to 150 sqmm complete including taking out old unserviceable one all as specifide and directed.
Supply and Fixing of cable jointing kit for 1.1 KV grade cable for outdoor end termination heat shrinkable type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 185 sqmm to 300 sqmm complete including taking out old unserviceable one all as specifide and directed.
Cutting & trimming of tree branches any girth and size touching to overhead lines and cleaning the distance 1.5 mtr both sides of overhead line with in a gap of span 35 mtrs each depositing the same for cleaning the site all as directed by the Engr-in-Charge.
Excavation in trenches not exc 1.5 mtr wide and n.exc 1.5 mtr in deep and getting out in Hard/Dense soil laying of cables etc.
Returning filling in including spreading, leveling watering and well ramming in layers n.exc 25cm thick using excavated soil
Removing excavated surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5mtr above from the starting point
Supplying and laying UNreinforced precast concrete cable cover class LV , Type 1 flat with size 250mm x150 mm x 40mm all as specified and directed by Engr-in-Charge.
M & L for brick protection cover of old size bricks common burnt clay building bricks sub class ’B’ of size 230 X 113 X 75mm laid dry and flat abutting each other with width equal to length of brick and gap between adjacent bricks not exceeding 10 mm complete all as specified.
Supply and spread approved dry river sand for foundations/Cable duct including watering and consolidation, cushioning of cable laid in trenches complete all as directed by Engineer-in-Charge Note:- Punned thickness will be measured for payment purpose
Laying only old Brick in trenches for Under Ground Cable Protection (Serviceable Materials obtained from Item No. 1 here-in-before), complete all as directed.
M&L for cleaning thoroughly the street light poles/LT distribution poles of any height and any description (Maximum 11 Mtr long ) with necessary cleaning agent including scrapping of old corroded paint dirt/ rust carefully and applying two coat of synthetic aluminium paint over existing coat of paint including marking of pole numbers and colour washing of pole coping complete all as specified and directed by Engineer-in-Charge. Make:- ASIAN (APCOLITE)/ SHALIMAR (SUPERLAC)/ BERGER (LUXOL)
All As per item No: 23 but for Two pole structure
All As per item No: 23 but for Four pole structure
S&F galvasised steel strip 32X6 mm with saddles and fixing screws on poreceling insulator/ spacer fixed at every 1 mtr length as lightening conductor on roof/wall of explosive building and joining the same with existing earth test point all as directed by Engr-in-Charge.
Advance Maintenance Free G.I. SAFE EARTHING Electrode with PIPE of not less than 50 mm outer dia( THICKNESS NOT LESS THAN -2.5MM) and two meter length, The electrode should be of galvinised (80 -100 micron) along with earth lead as Galvanised steel strip of size 32 X6 mm 7.5 m . The GI Electrode shall be pre-filled with Cristaline Conductive Material (CCM) . The GI electrode shall be surrounded with 25 kg BackFill compound to provide maximum contact between the electrode and Back Fill Compound. Backfill compound should be eco-frendly and having RoHs certification . GI Electrode Shall be tested from CPRI.The earting pit should be cover with pcc(1:2:4 , B1) cover ,of 300 x 300 mm complete all as specified and directed make ASHLOK / INDELEC/JMV /TERCEL/true power.
M&L preparing Steel and Iron Surfaces of any description, over 100mm width or girth and applying One Coats of Synthetic Enamel Paint (First quality) over a Coat of Red Oxide Zinc Chrome Primer, complete all as specified and as directed.
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 185 to 300 Sqmm 3.5 core complete all as specified and directed
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 70 to 150 Sqmm 3.5 core complete all as specified and directed
M&L for stright Through Joint heat shriankable type suitable for 1100 volt 25 - 50 Sqmm 3.5 core complete all as specified and directed
M&L for road crossing/drain crossing by adopting trench less tunneling work through specified pipe jacking method by erecting the equipment to true to the allignment and gradient by haidrolic pipe jacking technique complete including tunneling, excavation in any type of soils including hard rock, MS casing pipe havy duty of size 100 mm dia with 3 mm thick in any length including jointing materials to carry LT UG cables of size upto 120 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorites complete all as specified and as directed.
Supply and replace contactor ML 3 with coil operating voltage 230 Volt complete all as directed
Supply and replace Timer Analog Type Suitable for 24 hours operation of street light of 16 amps capacity (LEGRAND/AVV/CG)
Supply and Replace MCB TPN 32 Amps 10 KA, C Curve complete all as directed
supply and fix Nature switch operation should be based on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off > 10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs. complete including taking down old one. Make swadeep Model Nature switch -02(sensor)/ equivalent as approved by GE
supply and fix Nature switch operation should be based on natural light lux level. Required illuminance level for switching on is < 30 Lux and for switching off > 10 lux. The sensor should also have part night operation facility of min 4 hrs to max 12 hrs. The nature switch to be fiffed in a IP 54 SMC enclosure and protected with MCB SP 10 Amps complete including taking down old one Make swadeep Model Nature switch -02 E (sensor)
Taking down street light fittings of any watt ( tube light / T5 fittings only/SVL/MH FITTINGS ) existing position on pole/ wall/ tower, complete and deposite to MES store yard complete all as specified and as directed
Taking down serviceable street light fittings of any watt and type from existing position on pole/ wall/ tower including bracket / clamp and refix the same at new location in pole complete all as specefied and directed.
Taking out unserviceable junction boxes of any type or size for replacement from pole/wall and removing the same from site completeall as specified and directed.
Taking down old unserviceable post top lantern/bollard / Garden/ Gate light fitting of any watt and type from existing position complete for repair and replacement all as specified and as directed
Cutting anxious green growth / vegitation growth for cleaning out the area around transformer installations and four pole structure yards at ground level by cutting out roots, un wanted plants bushes and removel of the same by surface excavation not exceeding 30 cm deep average 15 cm complete INCLUDING REMUVING OF SHRUBS/ TREES
Supply, fixing, connecting and testing post top light fitting in spherical shape polycarbonate PMMA clear diffuser and IP65 protection, new generation energy saving and environmental friendly long life aesthetically desinged aluminium decorative luminaires with high power LED as light source of capacity 1X35/40 watts, fixed to Pole/Wall in any position including taking down old existing street light fitting of any type and capacity complete all as specified and directed. Make:- PHILIPS Cat Part No BGP161 LED2500/NW PSU 220-240V 7043 IN or CG MODEL NO LPTO 40 CDL/ Surya model lP07 501-XXX-57-CL / Havells Cat No. RUBYPT35WLED757PSYMTOPC or Wipro cat No.LP07-501-XXX-57-CL.
Supply, fixing, connecting and testing decorative LED Bollard light with opal diffuser and aluminium reflector of 8/9/11 watt LED including nut, bolts, washers, clamps etc as in repair complete all as specified and directed. Make:- C&S Cat Part NoLTGLCW9WLED or SURYA MODEL NO SLEBL 6W BLK800 or Havells Cat No. BAMBOOBL8WLED830SSYMTOPCM (1.0) or Wipro cat No.LB14-131-XXX-65-05.
Supply, fixing, connecting and testing energy saving, environmental friendly long life Varsatile pressure die cast aluminium alloy for housing (heat sink) with IP66 protection road way light fitting with high power LED as light source of capacity 60 watts with warranty option of 5 years with suitable driver and cable gland for maintaining ingress protection with Epoxy powder coated siemens grey finish after phosphochromate treatment, Tempered protective toughened glass,thermal shock and impact resistant fixed to the housing with SS screws , High efficiency long life LED chip in modules with lumen efficacy of >140 lm/W with PC lens and system lumen 6000. Powered by Built-in electronic LED driver with APFC (SMPS based constant current supply), lower THD, Open Circuit protection, Phase to Phase protection, Over Voltage protection, Surge Voltage protection. CCT 5700, CRI>70, THD<10%, PF>.95, IP66, IK07.Life class of 50,000 hrs @ L70, Operating Temperature:-10 TO +50 DEG.C; Input Supply Voltage Range:140-270 V, Frequency : 50-60 HZ, Driver
safety requirement standards :IS 15885-2-13, Test report to be submitted for Driver performance requirements as per IS 16104, for Photo bilogical safety norms as per : IS 16108, Certification as per LM 79 for Luminaire , LM 80 for LED Source, with all standard accessories etc, including disconnecting and taking down old existing light fittings any type/capacity from any height/position complete all as specified and as directed. Make: Bajaj Cat No.BRTFG 60W LED V3 or Havells Cat No. ENDURAPEARLPLUSSL60WLED757SASYTOPC or Wipro cat No. LR02-671-XXX-57-G2.
All as per item No.45 above, but 90 Watt LED Street light fitting with minimum system lumen out put 9000 lumen. Make: Bajaj Cat No.BRTFG 90W LED I or Havells Cat No. ENDURAPEARLPLUSSL90WLED757PASYTOPCASTHO or Wipro cat No. LR02-102-XXX-57-G2.
All as per item No. 45 here-in-before but Flood light of high power LED as light source of capacity 200 watts.. Make: Make : Bajaj Cat No.BARFEG 200W LED or Havells Cat No. JETAVALOURFL200WLED757PINTWBLTG or Wipro cat No. LF20-272-060-57-G2.
All as per item No. 45 here-in-before but Flood light of high power LED as light source of capacity 100 watts.. Make: Make : Bajaj Cat No.BARFEG 100W LED or Havells Cat No. JETAIRISFLS100WLED757SYMLTG or Wipro cat No. LF20-122-060-57-G2. Notes for item Nos 45 to48 :- (i) LED's used should be the make of Cree/Osram/Lumilieds/Nitchia, (ii) Contractor has to produce LM-79/ LM-80 certificate along with purchase vouchers and Guarantee certificate from Manufacturer. (iii) Surge protection (In-built) of the drive shall not be less than 10 KV or equivalent model in philips or Wipro.
All as per item No 43 above, but single phase load of 8 KW with Circuit wiring min10 sq mm 1 nos contactor each of 40 amps incoming and outgoing MCB (1 nos) rating 40 amps Make:-Model No. Swadeep-02EC 8kW1P or equivalent make as approved. Note for item No 49 and 50 :- (i) The contractor shall be obtained 1year gurranty and 1 year warranty for the sensor and 1 year warranty for the other accessories from the manufacturer and submitted to the deparment duly signed by all concerned.
Supply and fix lead acid battery 12 volt 180 AH suitable for DG set cmplete all as specified and directed . Make : Exide / amaron
Supply and fixing lantren of dia 60 CM for fixing of flood light, cap type to be fixed on the top of 9 m SP-31 Steel pole , made of MS pip medium grade dia greater than the top dia of the pole of length 0.35 M supported by MS flat iron of size 50X6 mm 8 nos including two coat of aliminium painting over a coat of redoxide primer complete all as directed
Supply and Replace Change over switch 200 amps side handel ONLOAD type 4 pole 415 volt with enclosure . Make: Havells/L&T/Schneider
Supply and Replace Change over switch 400 amps side handle ONLOAD type 4 pole 415 volt with enclosure . Make: Havells/L&T/Schneider
Supply and Replace Change over switch 400 amps suitable for panel mounting front operated ONLOAD type 4 pole 415 volt without enclosure . Make: Havells/L&T/Schneider
Supply and Replace Change over switch 200 amps suitable for panel mounting front operated ONLOAD type 4 pole 415 volt without enclosure . Make: Havells/L&T/Schneider
Supply and Replace Spreader link suitable for MCCB up to 125 Amps after taking proper shutdown in existing panel /feederpiller box complete all as directed
Supply and Replace Spreader link suitable for MCCB of 160 A after taking proper shutdown in existing panel /feederpiller box complete all as directed
Supply and Replace Spreader link suitable for MCCB of 200/250 A after taking proper shutdown in existing panel /feederpiller box complete all as directed
Disconnection and removing of MCCB's 415 volts 4 pole 35 KA breaking capacity Adjustable type of 400 Amps Capacity burnt out one from the existing position supply and fixing the same making conncetions including install and testing complete all as specified and directed. Make : L&T/Legrand/Havells.
All as per item no: 63 above but MCCB's 415 volts 4 pole 35 KA breaking capacity Adjustable type of 315-350 Amps Capacity
All as per item no:63 above but MCCB's 415 volts 4 pole 25 KA breaking capacity fixed type of 250 Amps Capacity
All as per item no:63 above but MCCB's 415 volts 4 pole 25 KA breaking capacity fixed type of 200 Amps Capacity
All as per item no:63 above but MCCB's 415 volts 4 pole 25 KA breaking capacity fixed type of 160 Amps Capacity
All as per item no:63 above but MCCB's 415 volts 3pole 25 KA breaking capacity fixed type of 160 Amps Capacity
All as per item no:63 above but MCCB's 415 volts 4pole 25 KA breaking capacity fixed type of 100 Amps Capacity
All as per item no:63 above but MCCB's 415 volts 3pole 25 KA breaking capacity fixed type of 100 Amps Capacity
Fabrication and installation of GI pipe bracket made of midium Grade tubing of size 40 mm dia, duly bended by hot forgoing after filling of sand, length 1.20 mtr including providing two pair of MS flat strip clamps 40 mm x 4 mm with GI bolts nuts and washer complete all as specified and directed
Material and Labour for drawing two runs of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 2.50 sq mm with one run of PVC insulated unsheathed single core multi stranded copper conductor FRLS cable of size 2.50 sq mm including 20mm dia PVC conduit of dia 20 mm medium gradeexclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, pipe hooks, clamps etc complete all as specified
S & F hot press moulded SMC junction / terminal box of size with internal diamensions of 200 x 140 x 95 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/glands, fixied on pole by means of clamps made out of MS flat iron of size 25 mm x 3 mm including dismantling of old unserviceable all as specified and as directed.Make: Hensel/Syntex/C&S/nyptune
M&L for Supply, test, erection & commissioning of Steel tubalar swaged poles staying in a truely vertical position till the foundations are properly set with the help crane complete with cast iron base plate, finial taper plug, bolts, nuts & screws including drilling of holes to poles for clamps & hooks for running of earth wire/Strip complete all as specified type 410 SP-31,09 mtrs LT poles and inluding and applying two coats of aluminum paint over a coat of red oxide primer and marking of zebra crossings up to a height of 1.0m above the coping with black and yellow strips of synthetic enamel paint including white wash to the coping and marking of pole numbers complete all as directed by Engr-in-Charge. Note:- (i) Crane charges for erection shall be deemed to be including in quoted rate. (ii) Earth work, PCC, coping shall be deemed to invluding in quoted rate. (iii) The rates include staying the poles in truely vertical position till the foundations are properly set. (iv)The rates include cast iron base plate, nuts, bolts, screws, painting of steel tubular poles, drilling of holes in steel tubular poles for fixing of clamps, hooks for continuous earth wire/strip. (v) The rate quoted shall be inclusive of pole painting.
Excavating in Trenches, not exc. 1.50 METRE wide and exc. 1.50 METRE but not exc. 3.00 METRE in depth, for Foundation of Poles, etc. and getting out in Soft/ Loose Soil, complete all as specified and as directed.
M&L for PCC 1:3:6 type C1 using 20mm graded aggregate as in coping /pedestals of poles including necessary form work and applying two coats of white wash to exposed surface of coping/platform complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded aggregate as in foundation, filling and mass concrete for pole / stay / post etc complete all as specified and directed.
Supply and fixing bracket/clamps made of MS flat strips, angle iron suitable size and shape duly fabricated to be fixed with GI bolts/nuts and washer for fixing of GI bracket, PVC conduit, pole junction box or flood lights all as directed and specified
M&L for twin core 1100 volt grade aluminium service wire cross sectional area 4.0 Sqmm for connection of light complete all as specified and directed
Supply, lay, test and commissioning of galvanized iron tubing 50 mm bore light grade with all fitting for fixing of garden light incl necessary clamp, bolt/nut if any and making hole on wall complete all as specified and as directed.
Cutting the existing PCC PATH / road straight by manual, depth and width not less than 0.5 mtr below ground level for passing of underground cable and filling back with excavated soil upto 75% road portion and 25% shall be made with cement concrete 1:2:4 (using 20 mm graded aggregate stone complete all as specified and directed.
S&FMCCB box made of sheet of 2mm thick size 30X20X15 CM Powder coated Suitable for fixing at Pole including two set of clamps comprisinf with the following i) MCCB 63 Amps 16 KA TP WITH BOTH SIDE SPREADER LINK.
Supply and lay PVC Insulated , PVC sheathed industrial HV round multicore flexible cable with copper conductor THREE core 2.5 sqmm including PVC conduit 20 mm dia medium grade and necessary bends, fittings and fixtures as required for connection of light fittings . ( uSED FOR GARDEN LIGHT CONNECTION, EXCAVATION , RETUNING FILLIING ETC WILL BE MEASURED AND PAID SEPARATELY.
Supply and fix Solar LED street light of 30 watt , 120 Lm/w , IP66 protection WITH LITHIM BATTERY complete all as specified and directed. Make : LUKER model LSTSOL30 / EQUIVALENT FROM PHILIPS/HAVELLS
Dismentling of damage / broken coping of PCC/steel pole of any size anf and removing the debries from site complete all as specified and directed
Dismantling Cross-Arms of Mild Steel Channel or Angle Sections, etc, including Mild Steel Bolts, Nuts, Washers, etc. and Serviceable Materials keep in Safe Custody for Re-use, complete all as specified and as directed.
Dismantling Insulators from Poles of any description and any size including Serviceable Materials Keep in Safe Custody for Re-use, complete all as specified and as directed.
Dismantling ACSR or AAC Conductors from the disturbed Span including Line Spacer, etc. Serviceable Materials Keep in Safe Custody for Re-use, complete all as specified and as directed.
M&L for making 2 nos hole in existing steel tubuler pole by welding for passing of street light cable inside the pole ( one near JB and another near buttom portion of street light bracket ) complete all as specified and directed
Cross-arms, Bracings, Supports, Clamps and Back Plates fabricated from Structural Steel Sections including Nuts, Bolts, Washer, welding, bending cold or hot, drilling holes for Bolts, in any shape or size as indicated or directed and inclusive of One Coat of Aluminium Primer, One Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed.
Re-fixing only Cross-arms, Bracings, Supports, Clamps and Back Plates, etc (Serviceable Materials obtained from Item No. 64 here-in-before) including applying One Coat of Aluminium Primer, One Under Coat and One Finishing Coat of Aluminium Paint, complete all as specified and as directed.
Stay Assembly complete with Accessories as show in Electrical Plate No. 1 of MES Schedule Part-I, diameter of Stay Rod 20mm, size of Plate 300X300 X6mm including 7/3.14.00mm Galvanised Stay Strand One Loop type Insulator, Vitreous Porcelain, White Brown or Green, Large size with Overall dimensions 90X140mm Clearance of Hole 25.5mm dia, complete all as specified and as directed.(CLAMPS ,EXCAVATION ,CONCRETE Measured and paid separately under relevent item)
Re-stringing & Re-Tightening of Stay Wire and maintaining Electric Poles of any descriptions properly Vertical after Stretching, adjustment of Stay Wire, etc., removing excess Sags if any, complete all as specified and as directed.
Re-fixing Serviceable Insulator of any description any Type, obtained from Item No.04 here-in-before complete all as specified and as directed.
S&F Insulator Pin type of size 100 mm height, 65 mm dia for 1100 Volt grade, porcelain, vitreous, white, brown or green including one galvanized MS Spindle, two GI washers and one GI washers including disconnecting/taking out old existing unsv insulators complete all as specified and directed.
S&F Insulator Shackle type of size 100 mm height, 115 mm dia for 1100 Volt grade, porcelain viterous, white, brown or green including galvanised mild steel straps of size 31x5 mm, washers, insulator bolts of size 14 mm and nuts including disconnecting/taking out old existing unsv insulators complete all as specified and directed.
S&F loop type insulator type of size 100 mm height, 115 mm dia for 1100 Volt grade, porcelain viterous, white, brown or green including galvanised mild steel straps of size 31x5 mm, washers, insulator bolts of size 14 mm and nuts including disconnecting/taking out old existing unsv insulators complete all as specified and directed.
Aluminium Conductor Steel Reinforced (ACSR) (sizes as ordered) and fixing on Electric Poles with binding to Insulators with Aluminium Binding Wire as in OH Conductors including Stringing, Tightening, complete all as specified and as directed.
Re-fixing ACSR Conductor of any size (serviceable ACSR Conductor obtained from Item No. 5 here-in-before) on Electric Poles and with binding to Insulators with Aluminium Binding Wire as in OH Con-ductors including Stringing, Tighten-ing, complete all as specified and as directed.
M & L Cradles, hexagonal/rectangular fabricated with Galvanised Steel Wire with 4.00/3.15 mm dia and fixed including dismantling old one , complete all as specified and as directed.
Re-stringing of LT over head line ACSR conductor on existing lines by unbinding at each pin/shackle type insulator and re-fixing the same after stretching conductor, removing exess sag, maintaining proper dintance between conductors as specified, trimming of tree branches, girth n. exc 30 cm up to two meter distance form line conductor, tightening of stay wire and making pole properly vertical all as specified and as directed.
Supply anf fix PVC separator suitable for LT 440 VOLT LINE ROUND TYPE MADEOUT OF 20MM DIA HEAVY DUTY PVC PIPE OF LENGTH NOT LESS THAN 30CM, SUITABLE FOR TWO LINE COMPLETE ALL INCLUDING NECESSARY FIXING ARRANGEMENT ALL AS SPECIFIED AND DIRECTED.
Supply anf fix PVC separator suitable for LT 440 VOLT LINE ROUND TYPE MADEOUT OF 20MM DIA HEAVY DUTY PVC PIPE OF LENGTH NOT LESS THAN 0.90RM, SUITABLE FOR FOUR LINE COMPLETE ALL INCLUDING NECESSARY FIXING ARRANGEMENT ALL AS SPECIFIED AND DIRECTED.
S&replace LED Driver suitable for 45 watts to 60 watts LED light fittings of philips make complete all as specified and directed.
S&replace LED Driver suitable for 70 watts to 90 watts LED light fittings of philips make complete all as specified and directed.
S&replace LED Driver suitable for 45 watts to 60 watts LED light fittings of bajaj make complete all as specified and directed.
S&replace LED Driver suitable for 70 watts to 90 watts LED light fittings of bajaj make complete all as specified and directed.
S&replace LED Driver suitable for 45 watts to 60 watts LED light fittings of havells make complete all as specified and directed.
S&replace LED Driver suitable for 70 watts to 90 watts LED light fittings of havells make complete all as specified and directed.
S&replace LED Driver suitable for 120/ 150 watts LED flood light fittings of havells make complete all as specified and directed.
S&replace LED Driver suitable for 200 watts LED flood light fittings of havells make complete all as specified and directed. Note for item No.76 to 83:Drivers shall be techincally compitable for existing fittings & frame size shall be matched to existing fittings.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–(SIZE NOT LESS THAN 1.05mx1.25mx0.4m)
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–(SIZE NOT LESS THAN 1.25mx1.25mx0.4m)
(a) Aluminium bas bar 200amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 160 amps ,415 volt ,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 01 NosMake Legrand model no: 420017/ Equivalent from Schinder/L&T/Hagar/Havells c)MCCB TP,63 Amp, 3 Pole, 415 Volt, 16 KA Breaking Capacity duly connected to Bus-bar as OUTGOING - 04 N0s.MAKE : Legrand model no: 420003 /L&T/Hagar/Havells (d) LED indicating lamps with holder for main supply indicating RYB - 01 set(03 Nos) Make AE/L&T (e) Instrument fuse holder, fused 4 amps - 06 Nos.
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3 mm thick CRCA Sheet with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–(sIZE NOT LESS THAN 1.35mx1.25mx0.4m)
Note:i) All Internal connection between MCCB and Changeover and Bus baNote:i) All Internal connection between MCCB and Changeover and Bus bar shall be connected by aluminium strip of suitable size and capacity. (II) All MCCB to be connected with both side Spreader Link. The rate shall deemed to be include in the item rate r shall be connected by aluminium strip of suitable size and capacity. (II) All MCCB to be connected with both side Spreader Link. The rate shall deemed to be include in the item rate
Supply, Installation, test and Commissioning CPRI APPROVED factory fabricated, out door type,LT FEEDER PILLAR BOX made out of 3 mm thick CRCA Sheet of size 1MX.75mX.35M with projected Globe roof for rain water protection Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :–
(a) Aluminium bas bar 200amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral. b) MCCB 100 amps ,415 volt ,16 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 01 NosMake Legrand model no: 420015/ Equivalent from Schinder/L&T/Hagar
Notes for Sl no 1 to 5 : Note:- (a) All existing incoming and out going cables are to be connected to the above panel with proper lugs, glands nuts, bolts etc the cost of work is deemed to be included in the above item.. (b) The cost shall also be include the breaking of floors/walls IF ANY including digging of trenches for removing of cables of loops and connecting to the new panel boards and making good the disturbed surfaces to match with the existing surfaces (c) The panel shall be Fabricated from a reputed firm(CPRI Approved) . Make of MCCB's: L&T or equivalent in Havells, lEGRAND etc. (d) All Internal connection between MCCB and Changeover and Bus bar shall be connected by aluminium strip of suitable size and capacity. (e) All MCCB to be connected with both side Spreader Link. (f) Sufficient space to be provided for cable connection between MCCB and Bottom of the panel board. (g) Base of the panel should not be less than 600 cmm above the ground level. Necessar PCC for base /foundation required deemed to be included in the quoted rate. (j) The rate shall deemed to be include in the item rate.
Supply and fix stay wire galvnised stay strand of size 7/3.15mm
M/S K Rama Rao
STANDARD AGENCIES
diesel power services (a.p)
L and S ENTERPRISES
EXELLENT POWER CORPORATION
Srinivasa Consructions
POWER CONSTRUCTION COMPANY
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .