Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance DOOR NO 48 50 PRAKASAM STREET SKCL HARMONY SQUARE T NAGAR T NAGAR CHENNAI TAMIL NADU 600017 | CHENNAI | TAMIL NADU | 600017 | Admitted-Finance |
| 2 | Admitted-Finance 96 ELECTRONIC CITY COMPLEX BANGALORE KARNATAKA 560100 | BENGALURU URBAN | KARNATAKA | 560100 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹18.5 L
Closing Date
17 Feb 2023, 3:00 pmClosed
Sekar Hirudhayam
TECHNIP ENERGIES INDIA LTD, CHENNAI
DCS AND ESD SYSTEM FOR NUMALIGARH REFINERY EXPANSION PROJECT
2022_NRL_723064_1
TP/082176C/NRL/PQ/077
Open Tender
Electronic Components And Devices
790 days
NUMALIGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹18.5 L
Yes
ONLINE
19 May 2023
11 Nov 2022
18 Feb 2023
11 Nov 2022
17 Feb 2023
10 Jan 2023
14 Nov 2022 - 6 Dec 2022
24 Nov 2022
Supply of complete DCS, ESD & ESD (F&G) package including Design, Engineering, manufacture of material and bought out components procurement, Assembly at shop. System Engineering, supply, testing and inspection (Factory Acceptance Test, IFAT & System Integration Test), Packing & forwarding,Documentation, commissioning spares, special tools and tackles, consumables erection materials along with its sub system and accessories, common monitoring systems as per enclosed specification/licensor specification, system architecture drawing, JSS, datasheet and other codes and standards or referred comprising of systems as prescribed in MR
Unit rate for Site Supervision charges for co-ordination with other 3rd party system vendors and unit EPCM contractors for erection, tray routing, installation, wiring, termination, testing activities of 3rd party cabinets in SRR/control room as listed in MR, Per Diem charges on normal working hours. (As per MR TP-1ZZZA-IC-RFQ-0020_D6) ( BIDDERS TO QUOTE UNIT RATE FOR DIEM CHARGES )
Unit rate for Site Supervision charges for co-ordination with other 3rd party system vendors and unit EPCM contractors for erection, tray routing, installation, wiring, termination, testing activities of 3rd party cabinets in SRR/control room as listed in MR for Overtime rate per hour (beyond normal working hours). (As per MR TP-1ZZZA-IC-RFQ-0020_D6) ( BIDDERS TO QUOTE OVER TIME RATE PER HOUR )
Unit rate for Site Supervision charges for co-ordination with other 3rd party system vendors and unit EPCM contractors for erection, tray routing, installation, wiring, termination, testing activities of 3rd party cabinets in SRR/control room as listed in MR for Overtime rate per hour for work on weekly off days / holidays (as applicable to Refinery Site). (As per MR TP-1ZZZA-IC-RFQ-0020_D6) ( BIDDERS TO QUOTE OVER TIME RATE PER HOUR )
Description of Work / Item(s)
2 years Normal operational & maintenance spares (as per vendor recommendation) item Sr No 1.00 (Spare no. - 1.01 (Mention the spare name and Qty in unpriced schedule)
Spare no. - 1.02 (Mention the spare name and Qty in unpriced schedule)
Spare no. - 1.03
Spare no. - 1.04
Spare no. - 1.05
Spare no. - 1.06
Spare no. - 1.07
Spare no. - 1.08
Spare no. - 1.09
Spare no. - 1.10
Spare no. - 1.11
Spare no. - 1.12
Spare no. - 1.13
Spare no. - 1.14
Spare no. - 1.15
Spare no. - 1.16
Spare no. - 1.17
Spare no. - 1.18
Spare no. - 1.19
Spare no. - 1.20
Spare no. - 1.21
Spare no. - 1.22
Spare no. - 1.23
Spare no. - 1.24
Spare no. - 1.25
Spare no. - 1.26
Spare no. - 1.27
Spare no. - 1.28
Spare no. - 1.29
Spare no. - 1.30
Spare no. - 1.31
Spare no. - 1.32
Spare no. - 1.33
Spare no. - 1.34
Spare no. - 1.35
Spare no. - 1.36
Spare no. - 1.37
Spare no. - 1.38
Spare no. - 1.39
Spare no. - 1.40
Spare no. - 1.41
Spare no. - 1.42
Spare no. - 1.43
Spare no. - 1.44
Spare no. - 1.45
Spare no. - 1.46
Spare no. - 1.47
Spare no. - 1.48
Spare no. - 1.49
Spare no. - 1.50
Description of Work / Item(s)
Supply of complete DCS, ESD & ESD (F&G) package including Design, Engineering, manufacture of material and bought out components procurement, Assembly at shop. System Engineering, supply, testing and inspection (Factory Acceptance Test, IFAT & System Integration Test), Packing & forwarding, Transportation, Documentation, commissioning spares, special tools and tackles, consumables erection materials along with its sub system and accessories, common monitoring systems as per enclosed specification/licensor specification, system architecture drawing, JSS, datasheet and other codes and standards or referred comprising of below systems: Unloading, handling at site, transportation to site store and from site store to worksite. Assembly at site, site installation, site testing, pre-commissioning, loop checking, site acceptance test. Hand over to client and other associated work includes associated residual civil/structural works for the below indicated items and Additional Services as required (e.g. Site services, training).
Description of Work / Item(s)
Site Services for installation, erection, cable routing activities inside SRR/control room, wiring, testing , pre-commissioning and commissioning activities as per clauses listed as part of Material requisition and its documents
Site services for installation, erection, cable routing activities inside SRR/control room, wiring , testing in co-ordination with respective package vendors, pre-commissioning & commissioning assistance for 3rd party systems as per clauses listed as part of Material requisition and its documents
Service support at site till commissioning: Bidder shall consider the following and shall comply: DCS & ESD system vendor to consider a group of residential staff (Expert (expert of OEM or OEM’s representative)) related to supplied DCS/PLC with technical staff) be available at site (on 24x7 basis at site) during the entire site activities (right from erection/ installation etc.), pre commissioning, commissioning activities related to DCS/ ESD system , unit commissioning stage and Post SAT Service support. Moreover mobilization/ de mobilization/ re-mobilization clause of CCD/CDD will be applicable for any situation not attributable to the bidder w.r.t delay in site works/ commissioning. This shall supersede the related clause mentioned in the MR.
Service support after SAT: The period shall be considered as 12 months from the date of completion of SAT irrespective of any warranty period/clause mentioned in the MR. Post SAT service mentioned as “during warranty period” in the MR (if any) to be ignored by the bidder. Also, bidder shall provide minimum 2 technical staff in addition to Engineer (s) for this service. For this service, separate work order shall be placed later on just before the completion of the SAT.
Unit Rate for addition & Deletion of DCS controller (For each type, make, model, series along with its mounting assembly)
Unit Rate for addition & Deletion of ESD controller (For each type, make, model, series along with its mounting assembly)
Unit Rate for addition & Deletion of ESD (F&G) Controlller (For each type, make, model, series along with its mounting assembly)
Unit Rate for addition & Deletion of Power Supply unit (a. For each type, make/model and rating of power supply unit used in the DCS, ESD, ESD (F&G) system and marshalling cabinets, IRP cabinets etc. b. Redundant Power supply in SIL 3 configuration)
Unit Rate for addition & Deletion of DCS Analog Input module- Non redundant (For each type, make/model, series of DCS non-redundant analog input module with their mounting /termination assembly)
Unit Rate for addition & Deletion of DCS Analog Input module- Redundant (For each type, make/model, series DCS redundant analog input module with their mounting /termination assembly)
Unit Rate for addition & Deletion of DCS Analog Output module – Non redundant (For each type, make/model, series of DCS non-redundant analog output module with their mounting /termination assembly)
Unit Rate for addition & Deletion of DCS Analog Output module- Redundant (For each type, make/model, series of DCS redundant analog output module with their mounting /termination assembly)
Unit Rate for addition & Deletion of DCS Digital Input module – Non redundant (For each type, make/model, series of DCS non-redundant digital input module with their mounting /termination assembly)
Unit Rate for addition & Deletion of DCS Digital Input module –Redundant (For each type, make/model, series of DCS redundant digital input module with their mounting /termination assembly)
Unit Rate for addition & Deletion of DCS Digital Output module – Non redundant (For each type, make/model, series of DCS non-redundant digital output module with their mounting /termination assembly)
Unit Rate for addition & Deletion of DCS Digital output module –Redundant (For each type, make/model, series of DCS redundant digital output module with their mounting /termination assembly)
Unit Rate for addition & Deletion of ESD Analog Input module- Redundant / Non-redundant (For each type, make/model, series ESD redundant analog input module with their mounting /termination assembly)
Unit Rate for addition & Deletion of ESD Analog Ouput module- Redundant / Non-redundant (For each type, make/model, series ESD redundant analog input module with their mounting /termination assembly)
Unit Rate for addition & Deletion of ESD Digital Input module –Redundant / Non-redundant (For each type, make/model, series of ESD redundant digital input module with their mounting /termination assembly)
Unit Rate for addition & Deletion of ESD Digital output module –Redundant / Non-redundant (For each type, make/model, series of ESD redundant digital output module with their mounting /termination assembly)
Unit Rate for addition & Deletion of ESD(F&G) Analog Input module- Redundant / Non-redundant (For each type, make/model, series ESD(F&G) redundant analog input output with their mounting /termination assembly)
Unit Rate for addition & Deletion of ESD(F&G) Analog output module- Redundant / Non-redundant (For each type, make/model, series ESD(F&G) redundant analog input module with their mounting /termination assembly)
Unit Rate for addition & Deletion of ESD(F&G) Digital Input module – Redundant / Non-redundant (For each type, make/model, series of ESD redundant digital input module with their mounting /termination assembly)
Unit Rate for addition & Deletion of ESD (F&G)Digital output module – Redundant / Non-redundant (For each type, make/model, series of ESD redundant digital output module with their mounting /termination assembly)
ESD (F&G) Unit rate for addition & Deletion of AI Barrier & Isolator (For each type of SIL-2 , Non SIL Analog Input Barrier & Isolator suitable for DCS, ESD, ESD (F&G), Remote IO cabinet etc.,)
Unit rate for addition & Deletion of AO Barrier & Isolator (or each type of SIL-2 , Non SIL Analog Output Barrier & Isolator suitable for DCS, ESD, ESD (F&G), Remote IO cabinet etc.,)
Unit Rate for addition & Deletion of DI Barrier (For each type of SIL-2, Non SIL Digital Input barrier suitable for ESD, ESD (F&G), Remote IO cabinet etc)
Unit Rate for addition & Deletion of DO Barrier (For each type of SIL-2 , Non SIL Digital Output barrier suitable for DCS, ESD, ESD (F&G), Remote IO cabinet etc)
Unit Rate for addition & Deletion of DI relays (For each type SIL-2, Non SIL Digital input rays suitable for DCS, ESD, ESD(F&G), Remote IO caninet etc)
Unit Rate for addition & Deletion of DO relays (For each type SIL-3, SIL2. Non SIL Digital output rays suitable for DCS, ESD, ESD(F&G), Remote IO caninet etc)
Unit Rate for addition & Deletion of Cabinet (For each type of system, marshalling, Power distribution cabinet, Remote IO, IRP, server, network cabinets etc)
Unit Rate for addition & Deletion of Engineering station (With all associated license, patch updates suitable for operation)
Unit Rate for addition & Deletion of Operator station (With all associated license, patch updates suitable for operation)
Unit Rate for addition & Deletion of RTD to mA converter (With provision of DIN rail mounting)
Unit Rate for addition & Deletion of Laptop (As per specification which shall be reviewed and approved)
Unit Rate for addition & Deletion of RTDBMS, Historian Batch license cost (In Increment of 1 batch (5000 tags))
Unit Rate for addition & Deletion of Auxiliary Console (Complete Auxiliary console)
Unit Rate for addition & Deletion of Single Mode FO cable (24 Core) (As per requirements provided in the Cable specification provided with MR)
Unit Rate for addition & Deletion of OPC server (As per specification defined elsewhere)
Unit Rate for addition & Deletion of Power cable 3Core 2.5 Sq mm (As per requirements provided in the Cable specification provided with MR)
Unit Rate for addition & Deletion of Chairs (To be quoted from reputed vendors and as per approved vendor list)
Unit Rate for addition & Deletion of Network switch (24 Port) (To be quoted from reputed vendors and as per approved vendor list)
Unit Rate for addition & Deletion of Router (To be quoted from reputed vendors and as per approved vendor list)
Unit Rate for addition & Deletion of Firewall (To be quoted from reputed vendors and as per approved vendor list)
Unit Rate for addition & Deletion of Console table (To be quoted from reputed vendor& as per approved vendor list)
Unit Rate for addition & Deletion of Printer Desk (To be quoted from reputed vendor& as per approved vendor list)
Unit Rate for addition & Deletion of Corrosion Monitor (To be quoted from reputed vendor& as per approved vendor list)
Unit Rate for addition & Deletion of RTD I/O card (For each type, make/model, series of RTD IO ce with their mounting /termination assembly)
ABB India Limited
Yokogawa India Limited
ABB India Limited
Yokogawa India Limited
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid