Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance ARIMALAM TAMIL NADU | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
₹59.3 L
EMD Value
₹62,000
Closing Date
18 Sept 2020, 3:00 pmClosed
The Project Director
The Project Director DRDA vellore
Vellore District Implementation of jal jeevan Mission II to Provide functional Household tap connection to rural household at mothakkal panchayat in kaniyambadi Block package no.75
2020_RDTN_176942_1
A11/1458/2020
Open Tender
Civil Works - Water Works
Item Rate
180 days
DRDA vellore
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹62,000
1 Oct 2020
24 Aug 2020
18 Sept 2020
24 Aug 2020
18 Sept 2020
24 Aug 2020
Amount
Providing for FHTC to MOTHAKKAL , ANNA NAGAR, VADAKKU KOTTAI, KASIMA NAGAR at Mothakkal Pt.Delivery Pipe Line to MOTHAKKAL , ANNA NAGAR, VADAKKU KOTTAI, KASIMA NAGAR at Mothakkal Pt. Const. of New 10000 Litres OHT at Anna Nagar at Mothakkal Pt.New Bore Well in Anna Nagar at Mothakkal New Bore Well in Mothakkal at Mothakkal Pt.
Providing Functional house hold tap connection @ MOTHAKKAL , ANNA NAGAR, VADAKKU KOTTAI, KASIMA NAGAR in Mothakkal Pt.
Providing Functional house hold tap Connection for etc Complete
Providing Delivery Pipe line Connection @ MOTHAKKAL , ANNA NAGAR, VADAKKU KOTTAI, KASIMA NAGAR in Mothakkal Pt.
Earth work excavation and depositing on bank with initial lead of 10m & 2m for pipe laying work with Standard trench width and depth etc completed.
Supplying and Delivery of 63mm dia 4 KSC PVC pipe as per IS 4985/part I/2000 including all conveyance charges 6KSC ISI standard PVC pipe including all labour charges etc completed
Supply and fixing of 63mm PVC Tee including all conveyence charge etc.
Supply and fixing of 63mm PVC Elbow including all conveyence charge etc.
Supply and fixing of 63mm PVC Bend including all conveyence charge etc.
Supply of Soluvent solution including all conveyence charge etc.
Laying and jointing of PVC pipe including all labour charges ets.
Refilling the excavated earth in the trench including all labour charges ets.
Construction of 10,000 LITRES Capacity OHT, Extension of pipe line at Anna Nagar in Mothakkal panchayat
Earth work excavation and depositing on bank with initial lead of 10m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth mixed with small sized boulders and hard gravelly soil as per SS 20B
Supplying and filling foundation and basement with filling sand in layers not more than 15cm thick well rammed, watered and compacted complete complying with standard specification
Cement conrete 1:4:8 mix using 40mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing laying and curing etc ocmplete for bed blocks for 10 cum
RCC1:1.5:3 mix using 20mm HBGS and 10mm HBS excluding the cost of reinforcement, centering and shuttering but including the cost of mixing placing vibrating of concrete curing and finishing etc., complete as directed by the officers.
below GL 1.50m to 4.50m
below GL 0m to 1.50m
above GL 0m to 4.50m ht.
above GL 4.51.to 7.32 ht.
above GL 7.33.to 10.98 ht.
Centering for soffits of RCCmembers or plane surface including shutterin, strutting to centering and providing supports etc complete for the following mbers using MS sheets of size 90cmx60cm BG 10 gauge stiffened with welded MS angles of size 25x25x3mm laid over silver oak (Country wodde) joist of size 10x6.5cm as directed by the officers
For Plane Surface
below GL
from 0.0m to 3.30m height above GL
from 3.30m to 4.30m height above GL
from 6.30m to upto 7.30m height above GL
Curve surface
upto 0.0m- 3.30m height (from floor slab)
Floor slab
Square Surface
Below GL
Columns above 0m to 3.30m height
Columns above 3.30m to upto 4.30m height
Columns above 4.30m to upto 5.30m height
Columns above 5.30m to upto 6.30m height
Columns above 6.30m to upto 7.30m height
Painting two coats with approved cement paint best quality over the plastered surface including cleaning preparing the surface, curingetc complete the quality, shade/colour of paing shall be got approved by the executive engineer.
Supplying fabricating and placing in position of RTS steel rods for reinforcement for various members including cost of steel and binding wire for all RCC works as directed by the officers.
Fabrication, supply and fixing of outside MS Lader 45 cm clear wide made out of 50 mm X 50 mm X 6 mm MS angle for both sides and for the steps at 30 cm center to center welded, joints etc., for 1st staging from ground level to 1st level grace.(weight 4.50KG per M 2nd and 3rd stating upto four slab and 4th staging from floor slab to roof top supply and delivery fixing of 32 mm gi pipe, medium for hand rail from 1st stage to 4th stage RCC M30 grade mix for landing slab - 5 nos, (ground level 1 no and above ground level (4 nos )supply and fixing of 30 mm GI pipe medium
Supplying and fixing of RCC inner access ladder in RCC 1:1 1/2: 3 mix etc complete
Providing GI Ventilation arrangement 2 nos mosquito proof nylon net with 65 mm GI pipe and spls as directed by the Board officers 1 m 65 mm Gi pipe, 4 nos 65 mm Gi elbow , 4nos cutting and 8 nos threading and 2 nos 65 mm GI tee
Providing cut stone slab in CM 1:3 of size 0.3 m x 0.3 m x 0.15 m and as directed by TWAD Board officers
Providing Manhole cover of size 60 x 60 cm in RCC 1: 1 1/2: 3 mix with suitable reinforecement including all labour charges
Provision for pipe connection arrangements
65m dia GI Pipe for inlet connection& outlet
65mm dia GI Pipe for over flow and rain water harvesting pipes
50mm dia GI Pipe for scour pipes
65mm dia GM Gate valve
50mm dia GM Gate valve
50 mm dia Flange set
Lifting charges for pipe connection
75mm dia pvc thread coupler
65mm dia GI Tee
65mm dia GI flange set
65mm dia GI coupling
65mm dia GI Elbow
50 mm dia GI Elbow
65mm dia pvc thread coupler
65mx 50mm dia GI Reducer
75mm x 63mm PVC Reducer
90mm x 75mm PVC Reducer
Refilling in basement with excavated earth in layers of not more than 15cm thick well rammed, watered and consolidated complying with standard specifications etc complete
Labour charges for GI pipe connection to the OHT, for inlet, outlet, overflow and scour arrangements including cutting and threading, earth work excavation & refilling.
Providing Hand rails over the Roof slab by using 32 mm GI Pipe with 40mm x 6mm MS Flat and fixied with 12mm dia Fastner Bolt 75mm long and as directed by TWAD Bd officers
Providing Hand rails over the Standing Platform by using 32 mm GI Pipe with 40mm x 6mm MS Flat and fixied with 12mm dia Fastner Bolt 75mm long and as directed by TWAD Bd officers
Electro Chloranation Disinfection Common salt as Per TWAD SOR Page No. 57 Clause 21.2
Construction of Platform allaround the OHT with Community Soak Pit and Anti Corrosive Epoxy Paint to the steel Reinforcement etc., Complete
Water Meter for Pumping Main Lines
Water Meter for Distribution Lines
Providing New Bore Well with 7.5 HP Motor and extension of pipe line at Anna Nagar in Mothakkal panchayat
7.5 Hp Sub Mersible Pumpset Heavy Duty 50 LPM x 225m Head
7.50HP Panel Board
4.00 Sqmm cable
50 mm GI Pipe Without Coupling
50mm GI Long coupling
50mm GI Elbow
50mm MS clamp set
50mm GI Flange set
50 mm Non Return Value
7/20 PVC Copper Wire EB Service
7/20 GI Wire
63A Fuse unit
Teakwood Board
MS Kiosk Board
HDPE PIPES -PN 6 - 90mm Dia (PE 100 AS PER IS 4984/2016)
HDPE PIPES -PN 6 - 90mm Dia SPECIALS FOR HDPE PIPES AS PER IS 8360/1997
Bore cover plate
Drilling of 180mm Dia Vertical Borewell in Over Burden area by using hard rock rig including cost of drilling etc.,
Casing pipes 180mm Dia
Drilling of 150mm Dia Vertical Borewell in Over Burden area by using hard rock rig including cost of drilling etc.,
Construction of Masonary pedeatal for Kiosk as per type design
Earthwork Excavation and depositing on bank with initial lead and lift in all soil
Labour charge for errection ofl three phase pumpset with GI pipe & cable connection complete
Laying and jointing the PVC pipes & specials into trench
Refilling the trench with excavated earth after laying the pipe
Provision for EB Deposit
New 10000 Litres OHT at Vadakku Kottai Medu with New Bore Well to Vadakku Kottai Medu ,New Bore Well in Kasima Nagar at Mothakkal Pt.
Construction of 10,000 LITRES Capacity OHT, Extension of pipe line at Vadakku Kottai in Mothakkal panchayat
Earth work excavation and depositing on bank with initial lead of 10m and initial lift of 2m in hard stiff clay, stiff black cotton soil, hard red earth mixed with small sized boulders and hard gravelly soil as per SS 20B
Supplying and filling foundation and basement with filling sand in layers not more than 15cm thick well rammed, watered and compacted complete complying with standard specification
Cement conrete 1:4:8 mix using 40mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing laying and curing etc ocmplete for bed blocks for 10 cum
RCC1:1.5:3 mix using 20mm HBGS and 10mm HBS excluding the cost of reinforcement, centering and shuttering but including the cost of mixing placing vibrating of concrete curing and finishing etc., complete as directed by the officers.
below GL 1.50m to 4.50m
below GL 0m to 1.50m
above GL 0m to 4.50m ht.
above GL 4.51.to 7.32 ht.
above GL 7.33.to 10.98 ht.
Centering for soffits of RCCmembers or plane surface including shutterin, strutting to centering and providing supports etc complete for the following mbers using MS sheets of size 90cmx60cm BG 10 gauge stiffened with welded MS angles of size 25x25x3mm laid over silver oak (Country wodde) joist of size 10x6.5cm as directed by the officers
For Plane Surface
below GL
from 0.0m to 3.30m height above GL
from 3.30m to 4.30m height above GL
from 6.30m to upto 7.30m height above GL
Curve surface
upto 0.0m- 3.30m height (from floor slab)
from 5.31 - 6.30 (floor slab sides)
Square Surface
Below GL
Columns above 0m to 3.30m height
Columns above 3.30m to upto 4.30m height
Columns above 4.30m to upto 5.30m height
Columns above 5.30m to upto 6.30m height
Columns above 6.30m to upto 7.30m height
Painting two coats with approved cement paint best quality over the plastered surface including cleaning preparing the surface, curingetc complete the quality, shade/colour of paing shall be got approved by the executive engineer.
Supplying fabricating and placing in position of RTS steel rods for reinforcement for various members including cost of steel and binding wire for all RCC works as directed by the officers.
Fabrication, supply and fixing of outside MS Lader 45 cm clear wide made out of 50 mm X 50 mm X 6 mm MS angle for both sides and for the steps at 30 cm center to center welded, joints etc., for 1st staging from ground level to 1st level grace.(weight 4.50KG per M 2nd and 3rd stating upto four slab and 4th staging from floor slab to roof top supply and delivery fixing of 32 mm gi pipe, medium for hand rail from 1st stage to 4th stage RCC M30 grade mix for landing slab - 5 nos, (ground level 1 no and above ground level (4 nos )supply and fixing of 30 mm GI pipe medium
Supplying and fixing of RCC inner access ladder in RCC 1:1 1/2: 3 mix etc complete
Providing GI Ventilation arrangement 2 nos mosquito proof nylon net with 65 mm GI pipe and spls as directed by the Board officers 1 m 65 mm Gi pipe, 4 nos 65 mm Gi elbow , 4nos cutting and 8 nos threading and 2 nos 65 mm GI tee
Providing cut stone slab in CM 1:3 of size 0.3 m x 0.3 m x 0.15 m and as directed by TWAD Board officers
Providing Manhole cover of size 60 x 60 cm in RCC 1: 1 1/2: 3 mix with suitable reinforecement including all labour charges
Provision for pipe connection arrangements
65m dia GI Pipe for inlet connection& outlet
65mm dia GI Pipe for over flow and rain water harvesting pipes
50mm dia GI Pipe for scour pipes
65mm dia GM Gate valve
50mm dia GM Gate valve
50 mm dia Flange set
Lifting charges for pipe connection
75mm dia pvc thread coupler
65mm dia GI Tee
65mm dia GI flange set
65mm dia GI coupling
65mm dia GI Elbow
50 mm dia GI Elbow
65mm dia pvc thread coupler
65mx 50mm dia GI Reducer
75mm x 63mm PVC Reducer
90mm x 75mm PVC Reducer
Refilling in basement with excavated earth in layers of not more than 15cm thick well rammed, watered and consolidated complying with standard specifications etc complete
Labour charges for GI pipe connection to the OHT, for inlet, outlet, overflow and scour arrangements including cutting and threading, earth work excavation & refilling.
Providing Hand rails over the Roof slab by using 32 mm GI Pipe with 40mm x 6mm MS Flat and fixied with 12mm dia Fastner Bolt 75mm long and as directed by TWAD Bd officers
Providing Hand rails over the Standing Platform by using 32 mm GI Pipe with 40mm x 6mm MS Flat and fixied with 12mm dia Fastner Bolt 75mm long and as directed by TWAD Bd officers
Electro Chloranation Disinfection Common salt as Per TWAD SOR Page No. 57 Clause 21.2
Construction of Platform allaround the OHT with Community Soak Pit and Anti Corrosive Epoxy Paint to the steel Reinforcement etc., Complete
Water Meter for Pumping Main Lines
Water Meter for Distribution Lines
Providing New Bore Well with 7.5 HP Motor and extension of pipe line at Vadakku Kottai in Mothakkal panchayat
7.5 Hp Sub Mersible Pumpset Heavy Duty 50 LPM x 225m Head
7.50HP Panel Board
4.00 Sqmm cable
50 mm GI Pipe Without Coupling
50mm GI Long coupling
50mm GI Elbow
50mm MS clamp set
50mm GI Flange set
50 mm Non Return Value
7/20 PVC Copper Wire EB Service
7/20 GI Wire
63A Fuse unit
Teakwood Board
MS Kiosk Board
HDPE PIPES -PN 6 - 90mm Dia (PE 100 AS PER IS 4984/2016)
HDPE PIPES -PN 6 - 90mm Dia SPECIALS FOR HDPE PIPES AS PER IS 8360/1997
Bore cover plate
Drilling of 180mm Dia Vertical Borewell in Over Burden area by using hard rock rig including cost of drilling etc.,
Casing pipes 180mm Dia
Drilling of 150mm Dia Vertical Borewell in Over Burden area by using hard rock rig including cost of drilling etc.,
Construction of Masonary pedeatal for Kiosk as per type design
Earthwork Excavation and depositing on bank with initial lead and lift in all soil
Labour charge for errection ofl three phase pumpset with GI pipe & cable connection complete
Laying and jointing the PVC pipes & specials into trench
Refilling the trench with excavated earth after laying the pipe
Provision for EB Deposit
Providing New Bore Well with 7.5 HP Motor and extension of pipe line at Kasima Nagar in Mothakkal Panchayat.
7.5 Hp Sub Mersible Pumpset Heavy Duty 50 LPM x 225m Head
7.50HP Panel Board
4.00 Sqmm cable
50 mm GI Pipe Without Coupling
50mm GI Long coupling
50mm GI Elbow
50mm MS clamp set
50mm GI Flange set
50 mm Non Return Value
7/20 PVC Copper Wire EB Service
7/20 GI Wire
63A Fuse unit
Teakwood Board
MS Kiosk Board
HDPE PIPES -PN 6 - 90mm Dia (PE 100 AS PER IS 4984/2016)
HDPE PIPES -PN 6 - 90mm Dia SPECIALS FOR HDPE PIPES AS PER IS 8360/1997
Bore cover plate
Drilling of 180mm Dia Vertical Borewell in Over Burden area by using hard rock rig including cost of drilling etc.,
Casing pipes 180mm Dia
Drilling of 150mm Dia Vertical Borewell in Over Burden area by using hard rock rig including cost of drilling etc.,
Earthwork Excavation and depositing on bank with initial lead and lift in all soil
Labour charge for errection ofl three phase pumpset with GI pipe & cable connection complete
Laying and jointing the PVC pipes & specials into trench
Refilling the trench with excavated earth after laying the pipe
Provision for EB Deposit
GST Amount for providing service to Government contract works for the above construction works. { GST amount is the Total GST amount for total overall quoted amount above this row in column "BB" for all works in this package}
Velu Raghavan
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .