EXECUTIVE ENGINEER
Room No. 602, 6th floor, BSNL Bhavan, Adarsh Nagar, Hyderabad-063
Providing Electrical Wiring, Computer sockets, LAN network, Fire Extinguishers, and other associated works for VMS at 7th floor Telephone Bhavan Saifabad (Recall)
2024_BSNL_208949_1
53/BEDH-II/2024-25 Dated 20-09-2024
Open Tender
Electrical Works
Item Rate
60 days
HYDERABAD
Please refer Tender documents.
15 documents required · 15 mandatory
₹590
AO CASH MAIN BSNL HYDERABAD
₹7,549
9 Oct 2024
21 Sept 2024
3 Oct 2024
21 Sept 2024
1 Oct 2024
21 Sept 2024
21 Sept 2024 - 27 Sept 2024
Amount
SH:I Electrical Installation and LAN wiring Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. a) 12 Module (200mmX150mm)
Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc., as reqd a) 5/6 A Switch
b) 3 pin 5/6A socket outlet
Supplying of following size of copper cable, PVC sheathed PVC insulated GI wire braided (flexible armouring) of 1.1kV grade suitable for operation on 230volts single phase AC supply of 50Hz, including laying on the cable on the surface/wall/existing cable tray, providing clamps, nuts and bolts, washers, cable tags where ever required etc., as required. a) 3 x 1.5 Sqmm
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 8 way (4 + 24), Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
Supplying and fixing following rating four pole 415V Isolator in the existing MCB DB complete with connections, testing and commissioning etc., as reqd a) 63Amps
Supplying and Laying of 3½ X 25 sq.mm Aluminium Armoured XLPE insulated and PVC sheathed power cable of 1.1 KV grade on existing cable tray / on wall etc., complete as required.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. a) 3½ X 25 sq. mm (28mm)
b) 3 x 1.5 Sqmm
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. (a) 1 run of cable
(b) 2 run of cable
(c) 3 run of cable
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. a) 20 mm
Supplying and fixing of LAN CAT6 RJ45 I/O Network Keystone Jack along with surface type gangbox, single face plate including all accessories, interconnections, testing etc., as reqd. M/s D-Link or SS make
Proviving and fixing of LAN CAT6 RJ45 connector to the existing LAN cable i/c interconnections, testing etc., as reqd.
Supplying and fixing of following accessores of LAN netwrok i/c interconnections, testing etc.as reqd. a) 2 mtr length Patch Cord (Ready made) M/s D-Link or ss make
Supplying and fixing of 16 port Gigabit LAN rack mount switch suitable for operation on 240V, 50Hz, AC supply including interconnections, testing etc., as reqd M/s Dlink / TP-Link or ss make
Supplying and fixing of 9U Metal Mounting Rack suitable for holding 2no 16 Port LAN switches with transparent door, locking arrangement, 4no power socket, cooling fan, wall mountable type etc. as reqd.
SH: II Misc works Supplying and fixing of 2KG Clean agent type Fire Extinguisher fitted with discharge control valve and pressure gauge i/c intial charging etc., as required. (Make:Safex dupoint FE 36 or ss make)
Portable Fire Extinguisher 4.5-Kg CO2 type: Supplying installation testing and commissioning of CO2 type (4.5kg) wall mounting type fire extinguisher with hose of suitable length including first charge / refilling & providing hook, hose clamps and with ISI mark on the extinguisher etc. as required. (Note: The Extinguisher will be Manufactured Strictly as per BIS: 13849:1993 bearing ISI. mark.
Supplying and fixing of floor grills of 700mm x 500mm MS supply air grills with aluminum louvers in two quadrants properly powder coated in matching with the colour of existing false floor and having adequate strength for 300Kgs weight along with volume control damper flush mounted on false floor. The frame should be free of rough edges and louvers must not project out of MS frame. Complete assembly is to fit seamlessly in the existing tile slot etc., as required. Damper should be operational from both the sides and settings should not get disturbed by flow of air through it. Minimum 70% area of floor grill should be supply air area. The air leakage through closed damper should not exceed 5% of fully opened air quantity.
Supplying and fixing of return air aluminum grills of 600mm x 600mm powder coated in matching with the colour of existing false ceiling, complete assembly is to fit seamlessly in the existing tile slot etc., as required.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .