| 1 | L1₹20.9 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L1 | Accepted-AOC lowest Bidder | |
| 2 | L2₹21.6 L+₹10,240 (0.48%)Rejected-AOC | L2 | Rejected-AOC Not lowest Bidder | |
| 3 | L3₹23.2 L+₹1.7 L (8.09%)Rejected-AOC | L3 | Rejected-AOC Not lowest Bidder | |
| 4 | L4₹23.4 L+₹1.9 L (8.86%)Rejected-AOC GROUND BALURGHAT COMPOUND NEAR TRIPURA ROAD KHANAPARA ROAD GUWAHATI KAMRUP METROPOLITAN ASSAM 781029 | KAMRUP METRO | ASSAM | 781029 | L4 | Rejected-AOC Not lowest Bidder | |
| 5 | L5₹2.4 Cr+₹2.2 Cr (1020.5%)Rejected-AOC | L5 | Rejected-AOC Not lowest Bidder |
Tender Value
₹29.5 L
EMD Value
₹59,000
Closing Date
20 May 2020, 6:00 pmClosed
GE(P) Kanasar
GE(P) Kanasar Military Engg Service , Kanasar, Bikaner -334001
Outsourcing of Services for Manning, Operation of water supply installation including repair and Maintenance of pumps, motors, starters etc at Military Station Kanasar
2020_MES_339778_1
CA No. GE(P)KNS-01/2020-21
Open Tender
Miscellaneous Works
Item Rate
334 days
Kanasar
As per NIT
7 documents required · 7 mandatory
₹500
Garrison Engineer(P) Kanasar
₹59,000
Yes
9 Jun 2020
21 Apr 2020
22 May 2020
21 Apr 2020
20 May 2020
5 May 2020
Amount
Note For Item No. 2.00, 3.00 & 4.00 here-in-after:- After opening of Financial Bid, if it is found out that quoted rates are below the existing minimum labour wages rates of semi-skilled labour (inclusive reliever to operator as per labour act) as prescribed by the Government of India/State Government/Local body whichever is higher including all statutory provisions such as EPF , ESI, Bonus, GST, Labour welfare cess etc as applicable, than Accepting officer at his sole discretion, has the rights to reject the quoted bid and the same shall be treated as “Non-Bonafide”. In such case the lowest tender shall be determined by lowest amount amongst valid bonafide bids for acceptance. Pl ref Note 50 on Page 18
Manning and operation of booster pump house at Shobhasar filtration plant also operate DG Sets in case of power failure with one FGM in each shift of eight hours for three shifts round the clock every day of month including Sunday and holidays, operating the pump sets and DG set all as specified and directed.
Manning and operation of water supply installation comprising of intake water from Shobhasar and pumping into the distribution system from 06 Nos booster pumps and also operate DG Sets in case of power failure with one FGM in each shift of eight hours for three shift every day of month including Sunday and holidays, operating the pump sets and DG Sets at FAD Kanasar all as specified and directed.
Manning and operation of FMN water supply installation comprising of intake water from main pump house and pumping into the distribution system i.e. 50 Nos SWTs within 10 KM radius and 50 Nos watch towers along with the security wall of approximate length 20 Km with two FGM in each shift of eight hours for one shift every day of month including Sunday and holidays, operating the pump sets , DG Set and distribution of water at 27 FAD Kanasar all as specified and directed.
NOTES :-( For Sch ‘A’ item No 2.00, 3.00 & 4.00 here-in-before) (a) The DG Sets shall run only in case of failure of electricity.(b) DHPP will be issued by the department under Sch `B' free of cost for running of DG Sets only at 27 FAD Kanasar MES store. (c) Timing of shifts shall be as directed by Engineer-in-Charge. (d) If any loss/damage takes place during operation of DG Sets the same shall be made good by the contractor and cost of the same shall be deemed to be included in rates quoted by tenderer. (e) Operator / FGM/ Electrician should be qualified as mentioned in PSS-II. (f) Rates quoted by tenderer is deemed to include following: -(i) General cleaning of DG Set rooms with cleaning of plants machinery, LT Panels, DG Sets, filter battery terminals.(ii) Cost of log sheets for DG Sets for daily running records in booklet form for a day complete all as directed by Engineer-in-Charge and as per sample supplied here-in-after in the CA.(iii) Cost of perishable & petty items such as oiling/greasing to moving parts generators, PVC insulation tapes wherever required and cost of broom sticks, cotton waste, dhoties etc for cleaning of machinery, LT panels, DG sets etc for installation shall be deemed to be included in quoted rates. (iv) Carry the diesel from MT yard of GE (P) Kanasar, Bikaner to installations as per requirement by the contractor at his own arrangement. (v) Necessary tools and plants required for efficient maintenance of DG Sets and pumps including required minor stores shall be provided by the contractor and the rates are inclusive in the quoted rates(vi) Cost of Uniform (Pant & Shirt ) and electric shock proof shoes (two times in the year) approved by Engineer-in-Charge.
M&L for disconnecting suction/delivery lines and coupling, taking down from foundation base frame, opening including dismantling of centrifugal pump set of capacity 10 HP and replacement of worn out spare parts and re-assembling, installed at same location, commissioning & testing complete all as directed by the Engineer-in-Charge. Notes:- (i) The spare parts required to be replaced shall be measured and paid for separately as "Supply only" under the relevant item here in after. (ii) Unit rate shall be deemed to include for all minor spares/extras. (iii) All spare parts shall be fixed in the pumps only after prior inspection & approval of Engineer-in-Charge.
SS Pump shaft.
CI Impeller complete with impeller key.
Shaft sleeve bronze with locking screw & lock nut.
Bearing suitable for pump set.
Bearing ring (DE & NDE) CI
Set of 'O' ring
CI gland cap with eye bolt complete.
GM gland sleeve bush.
All as per item No. 5.00 here-in-before including Notes but centrifugal pump set of capacity 40 HP
SS Pump shaft.
CI Impeller complete with impeller key.
Shaft sleeve bronze with locking screw & lock nut.
Bearing suitable for pump set.
Bearing ring (DE & NDE) CI
Set of 'O' ring
CI gland cap with eye bolt complete.
GM gland sleeve bush.
All as per item No. 5.00 here-in-before including Notes but centrifugal pump set of capacity 50 HP
SS Pump shaft.
CI Impeller complete with impeller key.
Shaft sleeve bronze with locking screw & lock nut.
Bearing suitable for pump set.
Shoulder Ring MS
Bearing ring (DE & NDE) CI
Set of 'O' ring
CI gland cap with eye bolt complete.
Gasket Set
All as per item No. 5.00 here-in-before including Notes but centrifugal pump set of capacity 25 HP
SS Pump shaft.
CI Impeller complete with impeller key.
Shaft sleeve bronze with locking screw & lock nut.
Bearing suitable for pump set.
Bearing ring (DE & NDE) CI
Set of 'O' ring
CI gland cap with eye bolt complete.
GM gland sleeve bush.
All as per item No. 5.00 here-in-before including Notes but centrifugal pump set of capacity 20 HP
SS Pump shaft.
CI Impeller complete with impeller key.
Shaft sleeve bronze with locking screw & lock nut.
Bearing suitable for pump set.
Bearing ring (DE & NDE) CI
Set of 'O' ring
CI gland cap with eye bolt complete.
GM gland sleeve bush.
Supply and fixing in replacement Flexible rubber Type of coupling suitable for following capacity motor pump set all as specified and directed :-
Suitable for 10 HP motor pump set
Suitable for 20 HP motor pump set
Suitable for 25 HP motor pump set
Suitable for 40 HP motor pump set
Suitable for 50 HP motor pump set
M & L for taking down defective induction motor of 10 HP capacity, 3 phase, 415 Volt, 50Hz from the foundation, disconnecting the electric connections coupling pulley and transporting to work shop, cutting down and removing existing burnt out copper winding, cleaning of slots and rewinding with solid copper conductor (winding wire) complete including varnishing, drying, ovening, overhauling, greasing and fixing in the same position, making necessary electric connection and testing of induction motor complete all as specified and as directed. Make of winding wire : CHETAK/ DEVIDAYAL/ FINOLEX/ ASIAN/EMGEE
All as per item No. 11.00 here-in-before but induction motor of 20 HP capacity, 3 phase, 415 Volt, 50Hz
All as per item No. 11.00 here-in-before but induction motor of 25 HP capacity, 3 phase, 415 Volt, 50Hz
All as per item No. 11.00 here-in-before but induction motor of 40 HP capacity, 3 phase, 415 Volt, 50Hz
All as per item No. 11.00 here-in-before but induction motor of 50 HP capacity, 3 phase, 415 Volt, 50Hz
S & F 15mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, including dismantling & taking out old unserviceable gate valve of 15mm bore, complete, all as specified & directed
All as per item No. 12.00 here-in-before but 20 mm bore
All as per item No. 12.00 here-in-before but 25 mm bore
All as per item No. 12.00 here-in-before but 40 mm bore
All as per item No. 12.00 here-in-before but 50 mm bore
All as per item No. 12.00 here-in-before but 80 mm bore
Supply and fixing Power Contactor 3 Pole MNX-32 complete including taking down old unserviceable power contactor all as specified & directed.
Supply and fixing Power Contactor 3 Pole MNX-50 complete including taking down old unserviceable power contactor all as specified & directed.
Supply and fixing Power Contactor 3 Pole MNX-80 complete including taking down old unserviceable power contactor all as specified & directed.
Supply and fixing overload relay range 6-20 Amps direct mounting on MNX power contactor complete including taking down old unserviceable relay all as specified & directed.
Supply and fixing overload relay range 30-50 Amps direct mounting on MNX power contactor complete including taking down old unserviceable relay all as specified & directed.
S & F electronic type Single phase Preventer in existing panel boards (max 600V & min 380V) three phase 415 Volts variation voltage 4% tripping time 2-5 second maximum including disconnecting & taking down old unserviceable Single phasing preventer, complete all as specified & directed.
M&L for repair to unserviceable sluice valve of size 80mm bore by dismantling and opening the gland cap and head of sluice valve and taking out the unserviceable lock nut, fitting the material on serviceable spindle, grinding the material cutting the threads by lathe machine and fabrication of new lock nut with cutting the threads inside the lock nut according to the spindle threads and refixing in the same position, testing the sluice valve, complete, all as specified and directed
All as per item No. 24.00 here-in-before but 100 mm bore
All as per item No. 24.00 here-in-before but 150 mm bore
Supply & fixing cast iron body sluice valve heavy duty class ‘PN-1.6’ of 150 mm bore, ISI marked with IS 14846, both flanged ends and drilled, high tensile stainless steel spindle, CI gate with brass ring, non rising type, cast iron wheel handle, cast iron cap, complete with 3mm thick neoprene rubber gasket joint and nuts, bolts (high tensile), washers etc, and testing, including dismantling & taking out old unserviceable CI sluice valve of 150 mm bore, complete all as specified & directed
All as per item No. 27.00 here-in-before but 100 mm bore
All as per item No. 27.00 here-in-before but 80 mm bore
M&L for repair to existing leaking run lead joint of CI/DI pipe or fittings of 80mm bore spigot and socketed ends by dismantling joint by melting the lead with the help of burner/blower including taking out old spun yarn and rejointing with & including additional quantity of pig lead required and good quality of spun yarn and testing of joint including necessary excavation & earth work in any type of soil including dewatering complete all as specified & as directed
All as per item No. 30.00 here-in-before but 100 mm bore
All as per item No. 30.00 here-in-before but 150 mm bore
Supply and fixing in replacement high tensile mild steel nuts, bolts & washers of any size, complete all as specified & as directed
Supply only Stable Bleaching Powder Grade-I conforming to IS-1065/1989 containing minimum chlorine percentage 34%, packed in laminated HDPE bags of 25 Kg each having two inner liners, ISI marked, complete all as specified & directed. Note : Bleaching powder shall be supplied on requirement basis as directed by the Engineer-in-Charge. Rate shall deemed to include this aspect.
Excavation in trenches not exceeding 1.5 mtr wide, and not exceeding 1.5 mtr in depth; for laying of cables, pipes in soft/loose soil etc and not exceeding 10 Sqm on plan and getting out including trimming of sides all as specified and directed by Engineer-in-Charge
Returning and filling in including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in soft/loose soil and making mounts of surplus soil
Removing excavated surplus soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point all as specified
M& L for galvanised steel water tubing medium grade of 15mm bore with & including all fittings complete, fixed to wall and ceilings or laid in floors, including taking up or down old unserviceable steel water tubing and connections of 15mm bore, complete all as specified
All as per item No. 38.00 here-in-before but 20 mm bore
All as per item No. 38.00 here-in-before but 25 mm bore
M&L for galvanised steel water tubing medium grade of 40mm bore with & including all fittings complete laid in trenches, including taking up or down old unserviceable steel water tubing and connections of 40mm bore, complete all as specified and directed. Note : Excavation & earth work shall be measured & paid separately under relevant items of this Schedule.
All as per item No. 41.00 here-in-before but 50 mm bore
All as per item No. 41.00 here-in-before but 80 mm bore
All as per item No. 41.00 here-in-before but 100 mm bore
Earthing complete with galvanized iron earth plate electrode of size 60cm x 60cm x 0.60 cm buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to the galvanized iron strip 32 x 6 mm as earthing lead by means of GI bolts/ nuts/ washers, protected by 15mm bore GI light grade pipe from earth plate and upto 3m along pole fixed with 2 clamps made from mild steel flat iron 25x3mm bolts, nuts and washers etc. Earth plate shall be surrounded by packed layer of coal dust 300mm and common salt 15cm thick all around bottom and top. 20mm GI light grade pipe for watering and including funnel , wire mesh , RCC 1:2:4 type B-1 using 20 mm graded stone aggregate cover of size 30 cm X 30 cm X 8 cm thick reinforced with expanded metal weighing not less than 4Kg/Sqm, PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in earthing pit including necessary excavation and earth work, all as specified and shown in electrical plate No-3 of SSR part-I and connected to earthing point and testing on completion. Note : PCC chamber shall be constructed at least 1.5m away from the Earth electrode and pipe for watering shall be provided in slanting manners
Supply, fixed in replacement multistranded cable PVC insulated 10 sqmm single core conforming to IS complete all as specified.
Supply & fixing cast iron foot valve of of 150 mm bore, ISI marked including dismantling & taking out old unserviceable CI sluice valve of 150 mm bore, complete all as specified & directed
All as per item No. 47.00 here-in-before but 100 mm bore
All as per item No. 47.00 here-in-before but 80 mm bore
Supply & fixing Non Return valve of of 150 mm bore, ISI marked including dismantling & taking out old unserviceable CI sluice valve of 150 mm bore, complete all as specified & directed
All as per item No. 50.00 here-in-before but 100 mm bore
All as per item No. 50.00 here-in-before but 80 mm bore
All as per item No. 50.00 here-in-before but 50 mm bore
Supply and fix in replacement Ammeter of size 96x96mm 0-60 Amp range complete all as directed by Engr in charge
Supply and fix in replacement Voltmeter of size 96x96mm 0-500 volts range complete all as directed by Engr in charge
Supply and fixed in replacement MCCB 400 Amps, 4 Pole, breaking capacity not less than 36 KA, 415 Volt, Thermal Adjustment & Adjustable Magnetic setting all as specified.
Supply and fixed in replacement MCCB 200 Amps, 4 Pole breaking capacity not less than 36 KA, 415 Volt, Thermal Adjustment & Adjustable Magnetic setting all as specified.
Supply and fixed in replacement MCCB 160 Amps, 4 Pole, breaking capacity not less than 36 KA, 415 Volt, Thermal Adjustment & Adjustable Magnetic setting all as specified.
Supply and fixed in replacement MCCB 100 Amps, 4 Pole, breaking capacity not less than 36 KA, 415 Volt, Thermal Adjustment & Adjustable Magnetic setting all as specified.
Supply and fixed in replacement MCCB 63 Amps, 4 Pole, breaking capacity not less than 36 KA, 415 Volt, Thermal Adjustment & Adjustable Magnetic setting all as specified.
Supply and fixed in replacement MCCB 32 Amps, 4 Pole, breaking capacity not less than 36 KA, 415 Volt, Thermal Adjustment & Adjustable Magnetic setting all as specified.
Cutting of road/ hard standing including repair of road with PCC as per existing all as specified and as directed by Engineer-in-Charge..
Supply only chlorine gas ISI marked, complete all as specified & directed. Note : Chlorine gas shall be supplied on requirement basis as directed by the Engineer-in-Charge. Rate shall deemed to include this aspect.
Supply and fixed in replacement change over switch of capacity 63 Amp with enclousers all as specified and directed by Engineer-in-Charge.
M/s Chopra Associates
JWALA ENTERPRISES
M/S SHREE SHYAM TRADERS
Aman Enterprises
Goyal Enterprises
NATIONAL ASSOCIATES
M/s Luxmi Constructions
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .