Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.7 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹11.5 L+₹75,852 (7.09%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹11.5 L+₹81,360 (7.61%)Rejected-AOC HOUSE NO 2 4 136 LINGREDDY MANSION BLOCK NO IV OPP HANUMAN TEMPLE TADBUND SECUNDERABAD 500009 | SECUNDERABAD | HYDERABAD | TELANGANA | 500009 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹12.6 L+₹1.9 L (17.5%)Rejected-AOC FLAT NO 101 2ND FLOOR RAGHAVENDRA RESIDENCY PLOT NO 1 2 3 SURVEY NO 27 PICKET SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L4 | Rejected-AOC Not Lowest | |
| 5 | L5₹13.2 L+₹2.5 L (23.5%)Rejected-AOC DOOR NO 43 2 BESIDES VIZAG DEFENCE ACADEMY 104 AREA KAPPARADA VISAKHAPATNAM 530013 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530013 | L5 | Rejected-AOC Not Lowest |
Tender Value
₹14.5 L
EMD Value
₹29,000
Closing Date
11 May 2020, 6:00 pmClosed
GE UTILITY SECUNDERABAD
GE UTILITY, MUDFORT, SECUNDERABAD-500003
PROVISION OF TROLLY MOUNTED 400 KVA STEP DOWN TRANSFORMER AT CDM SECUNDERABAD UNDER AGE EM NO I OF GE UTILITY SECUNDERABAD
2020_MES_336157_1
GE(U)/SEC/TOKEN/58 OF 2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
SECUNDERABAD
As per NIT
7 documents required · 7 mandatory
₹500
GE UTILITY SECUNDERABAD
₹29,000
Yes
29 May 2020
24 Mar 2020
13 May 2020
24 Mar 2020
11 May 2020
15 Apr 2020
Amount
Supply, installation, Testing and commissioning of double wound copper transformer step down, outdoor type complete with standard fittings, primary voltage of HT 11000 Volts and secondary LT 433 volts, 3 Phase 4 wire with frequency 50 c/s. Provided with 7 No of off load tappings on HT side to vary secondary voltage within range of +5% to - 10% (in steps of 2.5%), star delta connections with vector group of Dyn 11, Impedance of 4.5% and including first filling of transformer oil as per IS:335 and colour coating with one coat of primer and two coats of BS grey colour. Losses all as per IS:1180 (Level - ii) of capacity of 400 KVA with all standerd accessiories required proper functioning of Transformer including the following :
(a) Rating and Terminal marking plate- one b) Earthing Terminal- Two (c ) Lifting Lugs- Two (d) Drain valve with Blanking plate - One (e) Filter Valve with blanking plate- One (f) Conservator-One (g) Oil Level indicator with minimum marking (h) Dyhydrating breather-One (j) Air Release devise - One (k) Thermometer Pocket-One (l) Pressure relief valve - One (m) Roller unidirectional-Four (n) Both side (HV and LV) cable Box (o) Separate Brought out Neutral Terminal p) Off Circuit Tap Changer (q) 100 MM dia stem type Thermometer Make: Essenor/HIT/ABB/Schneider/BHEL Note: Commissioning of the transformer to be done by SEI/EI as detailed . Contractor should intimate one month in advance for commissioning of the same. Necessary arrangement for testing to be done by the contractor . Rates for the same deemed to be included in the quoted rate.
Supply of Trolley size of 3658mm Length X 1829mm Width X 2300mm Height with main chassis of size 100mm X 50mm MS channel of 6 mm thick, support channel of size 75mm X 40mm MS channel of 6 mm thick and floor with 6mm thick chequred plate. Side walls made up with welded wire mesh and Rear door fixed by hinges & lock. Axle 02 Nos of 63mm square, rim double plated 04 Nos. Tyres 04 Nos of size 7-50:16. Toe hook shall be made of forged steel, suspension system axle will be fitted with leaf spring and roof covered with GI sheet. Isolator and fuse mountings are of 63X63X40cm Box Pipe including connection between transformer and switch fuse box , 500 amps main switch 4 pole with HRC fuse protection , 50x50x5mm MS Angle and 75x38 mm " C" Channel clamp 2 nos for transformer. Carrying capacity of 5 Ton for mounting of 400 KVA Transformer. (Drawing of trolly attached). rate quoted by the contractor inclusive of the following : i) connection with flexible single core copper cable 1100 volt grade of size suitable for full load current ratings of transformer from transformer to Mainswitch. ii) Main switch 500 amps 4 pole with and incl HRC fuse including necessary fixing arrangement with its closed enclosure. Make : Narain Trolly Udhoyg / New India equipments/ Indotech engineers / as approved by GE
Supply, lay, connect, testing and commissioning of HT cable XLPE insulated screened PVC bedded galvanised steel strip armoured electric power cable heavy duty with aluminium conductor 11000 volts(E) grade corss sectional area of 95 Sqmm 3 Core confirming to IS:7098 Part-II laid in trenches/floors complete including lugs all as directed. Make : Havells/Gloster/Polycab
Supply, lay, connect test and commissioning of solid copper conductor cable XLPE insulated screened PVC tape innersheathed, unarmoured electric power cable heavy duty with aluminium conductor 1100 volts grade corss sectional area of 240 Sqmm single Core confirming to IS:7098 Part-I laid in trenches/floors complete including lugs all as directed. Make :- KEI Industries Ltd or equivalent in Havells/ Polycab/Plaza/Gloster
Supply ,Fixing and testing of cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and directed. Make :- M Seal/Raychem or equivalent in Denson/3M
SANJEEV CONSTRUCTIONS
omsai thermax engineers
L and S ENTERPRISES
Mavee Syndicate
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .