Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.1 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹12.4 L+₹9,282 (0.75%)Rejected-Finance MAGADH COLONY ROAD NO 6 PS MAGADH MEDICAL COLLEGE PO CHANDAUTI MORE DISTT GAYA BIHAR PIN 823001 | GAYA | BIHAR | 823001 | L2 | Rejected-Finance Quoted amount more than L1 | |
| 3 | L3₹12.5 L+₹15,465 (1.25%)Rejected-Finance | L3 | Rejected-Finance Quoted amount more than L1 | |
| 4 | L4₹12.6 L+₹29,725 (2.41%)Rejected-Finance | L4 | Rejected-Finance Quoted amount more than L1 | |
| 5 | L5₹14.2 L+₹1.9 L (15.5%)Rejected-Finance SHANTI KUNJ CHESIRE HOME ROAD BARIATU RANCHI 834009 JHARKHAND | RANCHI | JHARKHAND | 834009 | L5 | Rejected-Finance Quoted amount more than L1 |
Tender Value
₹13.9 L
EMD Value
₹28,000
Closing Date
5 Jun 2021, 6:00 pmClosed
Lt Col Vipin V Kumar
Garrison Engineer Ranchi, 7th Club Road, PIN-834001
SPECIAL REPAIR WORK TO BUILDING NO MES-15 (OR LIVING ACCN) OF 100 FD REGT AT ARMY CAMP JAMSHEDPUR UNDER GE RANCHI
2021_MES_439600_1
8200/1337/E8
Open Tender
Civil Works
Item Rate
180 days
Ranchi
Class E Cat a (i)
6 documents required · 6 mandatory
₹500
GE Ranchi
₹28,000
Yes
19 Jul 2021
30 Apr 2021
7 Jun 2021
1 May 2021
5 Jun 2021
14 May 2021
Amount
Dismantling timber scantling under 40 sqcm in section (Unframed work) as in filets, rails post, rafter etc all as specified and directed.
Dismantling of wall and ceiling boards any thickness including corner fillets all as specified and directed.
M&L for E-board ceiling sheet 600x600x4 mm thick fixed on GI Snap grid system (consisting of angle or tee section size 24 x 24 x 1.5mm thick angle section and 24 x 32 x 1.5 mm Tee Section) GI snap grid hanging with 03 mm dia GI hanger/wire fixed with steel dashed fastners complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S & F roof trusses (framed ) trussed, purline , crane gantries , rafter, rails and fastening and heavy brackets framing fast and similar small (beam, Tee, angle , channel plates or flat sections) including distance pieces cleats etc and necessary nuts bolts , rivets, welding, plates etc complete all as specified and directed by Engr-in-Charge Quality confirming to Fe-410-W ( Gde E-250) quality B.
S&F straps, supports or suspenders, hooks for hanging fans , MS plates,nut bolts, hold fast , clamps ,hooks , plate and similar small article etc. confirming to Fe 290 & Gde E-165 complete all as specified and directed.
M&L for preparation of old painted steel & iron surface of any description n exc 10 cm width or girth when connected with other painting or when painted in different tint applying two coats of synthetic enamel paint over on steel surface.
All as per item No 07 above but over 10 cm in width or girth , not otherwise described.
M&L for preparation of new painted steel & iron surface of any description n exc 10 cm width or girth when connected with other painting or when painted in different tint applying two coats of synthetic enamel paint over one coat of red oxide zink chromium primer on steel surface.
Dismantling AC corrugated /semi corrugated sheets in roof covering complete all as specified and directed.
S & F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Demolition of cement concrete (Un reinforced) in ground floors and pavings n. exc 15 CM thickness (below or above ground level) complete all as specified and directed.
Taking down cement plaster on brick or stone wall and any other type of wall finishes incl racking out joints hacking for key, scrubbing down with water and removing the debris from site complete all as specified and directed.
M & L PCC 1:3:6 type C2 , using 20mm graded aggregates as in 75mm thick plinth protection including bitumen joints in 1.0 Mtr centre to centre as required complete all as specified and directed.
S&F sheet glass ordinary quality & glazing with wooden bead/oil putty in Square n.exc 0.5Sqm in each panel 3 mm thick incl hacking out old broken glass ( any thickness, size, quality or des) complete all specified and directed.
Demolition of Brick work or stone masonry built in cement mortar complete all as specified and directed..
M & L Brick work with sub class `B` bricks straight or covered on plan any radius built in cm 1:6 complete all as specified and directed.
M & L Brick work with sub class `B` bricks straight or covered on plan to any radius in half brick thick wall built in cm 1:4 complete all as specified and directed.
M & L for rendering in cement mortar (1:6) , 15 mm thick on fair faces of brick work / Concrete /stone surfaces finished even & smooth without using extra cement complete all as specified and directed.
Taking down chowkats or frame exc.1.5 Sqm but not exc. 4 Sqm each with shutters (without taking off shutters) complete all as specified and directed.
All as item No 21 above but not exc 1.50 sqm
M & L for Cement conc type C-1 (1:3:6) 20mm graded stone aggregate as in bed block of hold fast complete all as specified and directed.
M&L for rolled section as in framing for door chowkat fixed with angle plate and connecting plate etc conforming to Gde- Fe -290 & Gde E-165
M&L for 35 mm thick flush shutters solid core construction,with block board core and plywood face panels,commercial type on both sides complete all as specified as directed.
S & F mild steel in framed work such as grills, grating, guard bars welded to steel frames and similar work confirming to Fe 410-O complete all as specified and directed.
S&F 35mm thick 2nd class HW Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed.
S&F 2nd class soft wood glazed and skeleton shutters 35 mm thick, open rebated and prepared to receive glass, gauze, etc (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred with beads for securing glass, etc. size of members of shutters as specified in SSR Part-I, Sec 8, Clause 8.24 (b) complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or stainless steel wire staples complete all as specified and directed.
S&F 150mm length of bolt aluminium anodized, barrel tower bolt of extruded section and fixed complete all as specified and directed.
S&F aluminum handles, cast type ,anodised 150 mm
S&F mild steel butt hinges cold rolled 100 mm size medium weight.
All as item No 32 but 75 mm size.
S&F Small article Such as wooden stopper (cleat) n.exc 200 Cucm each of 2nd class hard wood.
S&F mild steel sliding door bolts plate type stove enameled black with bright bolt not less tan 12 mm dia with and including minimum of 6 bolt & nut four on bolt plate and two on staple plate 250 mm.
M & L applying two coats of synthetic enamel paint over a coat of pink primer incl cleaning for new wooden surface complete all as specified and directed.
M&L for preparing newly plastered surfaces on walls/ceilling and applying two coats of distemper oil emulsion over JK wall care putty (two coats) including necessary chalk whiting and priming coats complete all as specified directed.
Complete removal of existing treatment of walls/ ceiling and applying two coats of distemper oil emulsion over JK wall care putty (two coats) including necessary chalk whiting and priming coats complete all as specified directed.
M&L Complete removal of existing treatment on wall and applying two coats of cement base paint of any colour over one coat primer complete all as specified and directed.
M&L for PCC/RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping, benching and other similar location with weathering slightly round edges and throating etc required with and incl all necessary form work complete all as specified and directed.
M&L preparation of old wooden surfaces exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
M&L for machine cut Kota stone slab flooring 18-20 mm thick (square or rectangular size.) over cement screed bed laid and pointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
All as item No 43 above but on vertical surface as dado/ skirting.
M&L for screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in C.M.1:4 for tiles.
M & L for rendering in cement mortar (1:3), 10 mm thick on fair faces of brickwork / Concrete /stone surfaces for backing coat of tiles / stone for dado and skirting.
M/L for cement concrete type B-0 (1:2:4) 12.50 mm graded stone aggregate 25 mm thick as in floor finish even and rough to receive topping layer.
Taking down carefully surface copper/ aluminium existing point wiring with wooden battens / PVC conduit (light, fan, socket, bell or power) including fittings such as switches, ceiling roses, lamp holders, pendants, sockets, regulators etc complete including removing material from site and making good any disturbed surfaces complete all as specified and directed.
Material and labour for point wiring alongwith earth continuity conductor with 1100 volts grade PVC insulated and FR multistranded copper conductor cable 1.5 sqmm (Phase - Red, Neutral - Black, Earth - Green) FRLS grade dwawn in and including PVC casing and caping not less than 20mm size and fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.12 mm covered with 2.80 mm thick phenolic laminated white sheet cover for mounting switches, sockets, fan regulators complete including 1.5 sqmm copper stranded earth wire for all as specified for the following :-
One light point controlled by one switch.
One fan point controlled by one switch.
One socket outlet 6 amp controlled by one switch on the same board.
One socket outlet 6 amp controlled by one switch on indepdendent board.
Material and labour for point wiring alongwith earth continuity conductor with 1100 volts grade PVC insulated FR multistranded copper conductor cable 2.5 sqmm (Phase - Red, Neutral - Black, Earth - Green) FRLS grade dwawn in and including PVC casing and caping not less than 20mm size and fixing accessories and sunken galvanized pressed steel terminal boxes of thickness not less than 1.12 mm covered with 2.80 mm thick phenolic laminated white sheet cover for one 15 amp socket outlet controlled by one switch on independent board incl 1.5 Sq mm copper conductor earth wire and connected to common earth dolly on independent board.
Supplying and fixing angle holder, insulated polycabonate body with back plate complete.
Supplying and fixing switch piano flush button single pole one way 5/6 amp complete.
Supplying and fixing switch socket combination two in one 5 and 15 Amps multipurpose flush type universal 240Volts.
Supplying and fixing socket outlet 2 in 1, 5 pin, 5/6 amp, flush type complete.
Supplying and fixing ceiling rose 63 x 25 mm three terminals complete all as specified and directed.
Material and labour for submain wiring alongwith earth continuity conductor with PVC insulated FR multistranded copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) drawing into existing surface / concealed conduit of nominal size 6 sqmm complete with 2.50 sqmm copper conductor as earth continuity. (Note:- Locations where concealed conduit will be found damaged or submain wiring requires relocation, it will be done by laying new PVC conduit and making it concealed. Cost of conduit is not included in this item).
Taking down U/S fan regulator and Supplying and fixing hum free electronic step fan regulator 120 - 280 volts of 100 watt capacity (socket type) including connecting up complete all as specified and directed.
Supplying and fixing integrated LED 18 watt complete. Make - Philips or Osram or Wipro as approved.
Supplying and fixing LED tube light fiting 1X18 watts , 230V with 18 watts slim tube Box type epoxy powder coated CRCA sheet housing with reflector cover channel, with bipin holders, connector block etc complete with all accessories internally pre wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size. Make - Philips / Wipro/ Hawells
Supplying and fixing LED bulk head fitting 1x 9 watt with LED including connection with PVC insulated flexible flat twin core multi stranded copper conductor cable 0.5 sqmm as required.
Supplying and fixing powder coated, CRCA steel sheet MCB distribution board double door (minimum thickness 1.2 mm & constructed as per IS : 8623), degree of protection IP 43 - IK 09 with metal door, recess mounted, having insulated 100 amp tinned copper bus bar, neutral busbar, earth bar, din bar, detachable gland plate, interconnection, earthing connection, blanking plates in unused spaces etc as required of following ratings & ways:-
SPN, 240 volts, 4 ways. Make - Legrand / L&T (Hager) or HPL as approved.
Taking down U/S MCBs/ELCBs with incoming and outgoing controls any make, any capacity after disconnecting complete.
S&F MCB SPN 6A to 40A 240V 9KA
S&F MCB SP 6A to 32A 240V 9KA
Supplying and fixing in renewal PVC insulated and sheathed three core multi stranded copper conductor flexible cable of size 0.5 sqmm complete all as specified and directed.
Taking down MCB distribution boards with incoming and outgoing controls any make, any capacity after disconnecting complete all as specified and directed.
Taking down carefully aluminium submain wiring with wooden battens / PVC surface conduit and making good disturbed surfaces complete all as specified and directed.
Taking down U/S wooden board off any sizes
Taking down U/S service connection with suspension wire and S/F twin core PVC insulated and PVC sheathed cable 10 Sqmm with aluminum stranded conductor in service connection suspended by insulated hangers and not more than 1.0 Mtr apart and including 4mm dia suspension GI wire etc complete all as specified and directed.
S/F House service bracket (hook Type)Complete with 3.0 M long GI Pipe 40mm dia med grade with 2 Nos 90 degree bends M S Hook and stay or guy complete all as specified and directed.
Dismantling house service bracket any type complete all as specified and directed.
M/S Sweta Construction
UPENDRA KUMAR SINGH
M/S Anjan Kumar Singh
BHARATI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .