Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.1 LAccepted-AOC PLOT NO 5 QIAGEN LNDIA PVT LTD CORPORATE ONE DISTRICT CENTRE JASOLA NEW DELHI 110025 JASOLA SOUTH DELHI DELHI 110025 | SOUTH EAST DELHI | DELHI | 110025 | ₹10.1 L Quoted ₹3.4 Cr | L1 | Accepted-AOC as per attachment |
| 2 | L1₹28.9 LAccepted-AOC R 28 PURUSHOTTAM EAST END SBI COLONY MP NAGAR ZONE II BHOPAL M P | BHOPAL | MADHYA PRADESH | 462011 | ₹28.9 L Quoted ₹7.3 Cr | L1 | Accepted-AOC as per attachment |
| 3 | L1₹64.7 LAccepted-AOC 1ST FLOOR BHOPAL MADHYA PRADESH 462001 | BHOPAL | MADHYA PRADESH | 462001 | ₹64.7 L Quoted ₹2.8 Cr | L1 | Accepted-AOC as per attachment |
| 4 | Rejected-Technical | - | - | Rejected-Technical Rejected as per attachment |
Tender Value
Refer Docs
EMD Value
₹16.8 L
Closing Date
9 Jan 2024, 2:00 pmClosed
Police Head Quarter, Bhopal, M.P., 462008
Police Head Quarter, Bhopal, M.P., 462008
FSL Kit Items with Accessories
2023_MPP_319164_1
PHQ/15/GPC/7282-1/23
Open Tender
Miscellaneous Goods
Item Wise
45 days
Police Head Quarter, M.P., 462008
Please Refer Tender Documents
2 documents required · 2 mandatory
₹15,000
Yes
₹16.8 L
Yes
Police Head Quarter, Bhopal, M.P., 462008
30 Jul 2024
12 Dec 2023
10 Jan 2024
13 Dec 2023
9 Jan 2024
23 Dec 2023
19 Dec 2023
List of Kits items with Accessories
Automated DNA Extraction Kit 1. All reagents and plastic ware for the purification of gDNA should be included with the kits. 2. Kits based on pre-dispensed cartridges format, should utilize magnetic bead-based technology for efficient DNA purification from all kind of common & challenging samples like body fluids, blood, vaginal and semen stains, tissue, bone, tooth, hair, chewing gum, cigarette butts samples etc. 3. The required reagents for DNA extraction such as Lysis buffer, Proteinase-K/ DTT and or anything which is part of recommended protocol of the manufacturer including suitable thermomixer (04 nos with the first order) should be supplied 4. The kit should be compatible with Auto Mate Express/EZ1 Advanced instrument / Maxwell FSC instrument 5. Manufacturing of provided kit should follow ISO 18385 certified guidelines and kit should be HID validated 6. All reagents and plastic ware for the purification of gDNA should be included with the kits
DNA Extraction Kit for HID Nimbus Presto Automated DNA extraction System (Routine forensic sample) 1. The kit should be validated in accordance Scientific Working Group on DNA Analysis Methods (SWGDAM) guideline for use in human identification testing (HID Validated). 2. All the Forensic validated reagent and recommended plastic ware for the Purification of gDNA should be supplied along with the kits 3. Kit should utilize integrated magnetic particle-based technology for DNA purification with full optimized and validated scripts compatible with HID Nimbus Presto 4. Kit should utilize optimized and validated scripts for efficient DNA purification from Routine forensic sample types, including: Body fluids (blood, saliva, semen) Stains and swabs of body fluids, Hair roots &Touch/trace samples. 5. Required reagent for DNA extraction such as Lysis Buffer, Magnetic Particles, and Wash Buffers Concentrate & Elution Buffer should be included in the kit. 6. Required plastic wares for DNA extraction and purification should be supplied along with the kit. 7. Kit should with compatible with available HIDNIMBUS Presto System and required documentation should be provided and scripts should be available on the system. 8. Manufacturing of provided kit should follow ISO 18385 certified Guidelines (Forensic Grade Quality assurance production environment in accordance with ISO18385:2016).
DNA Extraction Kit for HID Nimbus Presto Automated DNA extraction System (difficult forensic sample) 1. The kit should be validated in accordance with the DNA Advisory Board (DAB) Quality Assurance Standards and guidelines from the Scientific Working Group on DNA Analysis Methods (SWGDAM) for use in human identification testing (HID Validated). 2. All the Forensic validated reagent and recommended plastic ware for the purification of gDNA should be supplied along with the kit 3. Kit should utilize integrated magnetic particle-based technology for DNA purification in an automated liquid handling platform with full optimized and validated scripts compatible with HID Nimbus Presto 4. All the reagent and plastic ware for the purification of DNA should be supplied along with the kit 5. kit should utilize magnetic bead-based technology for efficient DNA purification from difficult forensic sample types, including: Bone, Teeth, Adhesive substrates (such as cigarette butts, chewing gum, and tape lifts) & Touch/trace samples 6. Required reagent for DNA extraction such as Lysis Buffer, specific Lysis Buffer for Bone Tooth and challenging samples, Magnetic Particles, Wash Buffer A Concentrate, Wash Buffer B Concentrate, Elution Buffer & Proteinase K should be included in the kit 7. The required plastic wares for DNA extraction and purification should be supplied along with the kit 8. Kit quoted should with compatible with available HID NIMBUS Presto System and scripts should be available on the system. 9. Manufacturing of provided kit should follow ISO 18385 certified Guidelines (Forensic Grade Quality assurance production environment in accordance with ISO18385:2016).
DNA Quantification kit 1. The kit should provide all the components and standards to quantify human genomic DNA, male DNA, and determine degradation and Inhibition index of the sample using qPCR. 2. Detection of amplification for all targets using the kit should be performed using TaqMan/Hydrolysis probe chemistry. 3. Detection limit of the kit should be1.0pg/µl or better 4. The quantified DNA should either be suitable for autosomal STR based or Y- chromosome specific STR based testing. 5. Kit should be compatible with ABI 7500 Real time PCR Systems/QuantStudio™ 5 Real-Time PCR System. Required suitable all calibration kit should be provided by the vendor. 6. Kit should be in small aliquots of 100 or 200 or 400reactions. 7. Manufacturing of provided kit should follow ISO 18385 certified guidelines and kit should be HID validated
Genotyping Kit for Autosomal STR Markers 1. The autosomal STR kit should contain all reagents for the multiplex amplification of at least22 or more STR loci with all the 20 CODIS core loci and should include SE33, Penta D and Penta E (at least two of these should be part of single multiplex) along with published forensic validation as per SWGDAM guideline in PUBMED journal. 2. Kit should also include one or more Y Indel /Y STR and Amelogenin marker. 3. Multiplex kit should support 6 dye based improved chemistry and resistance for PCR inhibitors. . 4. Storage at 2-8 degree after initial use. 5. Kit should be compatible with CE System ABI 3500 xL. 6. Suitable allelic ladder, control DNA, suitable size standard, PCR grade water must be included in the kit. 7. Appropriate matrix calibration standard (05 sets), panels, bin sets compatible with Gene Mapper ID-X 1.6 8. The kit should be highly sensitive to detect ≤ 0.5 ng of DNA or better. 9. Manufacturing of provided kit should follow ISO 18385 certified guidelines and kit should be HID validated. 10. Kit should be supplied in small aliquots of 100/200/400 reactions.
Genotyping Kit for Y chromosome Markers 1. Kit should work with 5-dye/ 6-dye chemistry for analysis of 23 or more Y Chromosome STR markers along with published forensic validation as per SWGDAM guideline in PUBMED journal. 2. Reaction Mix should provide excellent sensitivity and robustness against inhibitors, even in high female backgrounds 3. Storage at 2-8 degree after initial use 4. Kit should include Allelic Ladder, Control DNA, PCR grade water and Size Standard along with Master mix and Primer Mix with pack size of 100 reactions or 200 reactions 5. Appropriate matrix calibration standard (5 sets), panels, bin sets compatible with Gene Mapper ID-X 1.6 6. Kit should be compatible with CE System 3500 xL 7. The kit should be highly sensitive to detect ≤200pg or better. 8. Manufacturing of provided kit should follow ISO 18385 certified guidelines and kit should be HID validated.
Mitochondrial Sequencing kit 1. Kit should be sensitive for identification of highly-degraded samples and other difficult samples and should work in cases with failure of autosomal STR amplification. 2. Kit should be Mitochondrial Sequencing of HVI and HVII region. 3. Kit sensitivity- equal to or less than 125 picograms or more 4. Kit should be supplied in small aliquots of 50/100 reactions 5. Kit should have all required chemical and kit for Extracted DNA to Mitochondrial Sequencing of HVI and HVII.
X- STR Kit 1. Kit should have the minimum 12 or more X-STR markers 2. Kit should work on ABI 3500xL Genetic analyzer. 3. Kit sensitivity- equal to or less than 200 picograms 4. Kit should be supplied with appropriate quantity of Control DNA, size standard, allelic ladder and PCR grade water (cost of Control DNA, size standard, PCR grade water and allelic ladder should be included in the kit) 5. Suitable Matrix standards should be supplied with this supply order. 6. Kit should be supplied in small aliquots of 50/100/200 reactions
Kits for STR analysis by NGS 1. Kits should have STR Pannel 35 or More Markers 2. Barcode adaptor 1-32 Set for Automation Process, 3. Library prepation Kits for Automation Process 4. Libray Quantitation kit 5. Template prepation kits for Automation Process 6. Chips-530 7. Sequencing Kits & Reagent and other requirements for automation Process.
Kits for Whole Mitochondrial sequencing analysis by NGS 1. Kits should have whole Mitochondrial sequencing panel 2. Barcode adaptor 1-32 Set for Automation Process, 3. Library prepation Kits for Automation Process 4. Libray Quantitation kit 5. Template prepation kits for Automation Process 6. Chips-530 7. Sequencing Kits NGS & Reagent and other requirements for automation Process.
Rapid body fluid identification kit for human blood (forensic validated kit) 1. Kit should be Forensically validated 2. Kit should be based on Human hemoglobin (Hb) 3. Kit should be specific for human Blood detection 4. The cassettes should have a feature of possible semi-quantitative analysis of body fluid. 5. The detection should be Immunochromatography based with high specificity and high sensitivity (>99.5%) towards detected body fluid. 6. The Kits supplied have peer reviewed publications in forensic journals in international journals.
Rapid body fluid identification kit for human semen (forensic validated kit) 1. Kit should be Forensically validated 2. Kit should be based on Prostate-Specific Antigen (PSA) 3. Kit should be specific for human semen detection 4. The cassettes should have a feature of possible semi-quantitative analysis of body fluid. 5. The detection should be Immunochromatography based with high specificity and high sensitivity (>99.5%) towards detected body fluid. 6. The Kits supplied have peer reviewed publications in forensic journals in international journals.
Rapid body fluid identification kit for human saliva (forensic validated kit) 1. Kit should be Forensically validated 2. Kit should be based on Human Alpha Amylase 3. Kit should be specific for human saliva detection 4. The cassettes should have a feature of possible semi-quantitative analysis of body fluid. 5. The detection should be Immunochromatography based with high specificity and high sensitivity (>99.5%) towards detected body fluid. 6. The Kits supplied have peer reviewed publications in forensic journals in international journals.
Anode Buffer Container (ABC) 3500 Series, 4 per pack
Cathode Buffer Container (CBC) 3500 Series, 4 per pack
3500 POP-4TM POLYMER EA 384 sample, 384 samples
HI-DI FORMAMIDE 25mL BOTTLE, 384 samples
Conditioning Reagent, 3500 Series,
Septa for 3500/3500xL Genetic Analyzers, 96 well, 20 per pack
24 Capillary array 36 cm compatible with 3500xl , one set
MicroAmp™ 96-Well Support Base, 10 per pack
MicroAmp™ Adhesive Film Applicator, 5 per pack
Retainer & Base Set (Standard) for 3500/3500xL Genetic Analyzers, 4 per pack
ROI & Background Calibration Kit compatible with ABI 7500 Real time PCR Systems/QuantStudio™ 5 Real-Time PCR System
QuantStudio™ 3/5 10-Dye Spectral Calibration Kit
QIAGEN INDIA PVT LTD
V.K.Traders
V.K.Traders
QIAGEN INDIA PVT LTD
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .