Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹55.6 LAccepted-AOC AT BUDBIJAM PO ORIENT COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | L1 | Accepted-AOC The amount quoted by L1 bidder M/s Bikash Enterprises is 28.03 percent below the estimated cost/ updated cost | |
| 2 | L2₹60.3 L+₹4.7 L (8.38%)Rejected-Finance AT RAMPUR COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | L2 | Rejected-Finance On being L2 | |
| 3 | L3₹72.1 L+₹16.5 L (29.6%)Rejected-Finance AT MAGURGANDAPATNA PO BHARATPUR P S KENDRAPADA DIST KENDRAPADA | CUTTACK | ODISHA | 754134 | L3 | Rejected-Finance On being L3 |
Tender Value
₹77.3 L
EMD Value
₹96,700
Closing Date
3 Jul 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Vijay Kumar Staff Officer(EnM) Lakhanpur Area
Vijay Kumar Staff Officer(EnM) Lakhanpur Area GM Office Bandhabahal Dist-Jharsuguda Odisha-768211 Mob-9437595715
Providing power supply arrangement for proposed Y- curve siding at Lakhanpur OCP, Lakhanpur Area, MCL
2023_MCL_281459_1
MCL/LKPA/EnM/eNIT/23-24/35 dt-13.06.2023
Open Tender
Electrical and Maintenance Works
Item Rate
75 days
Lakhanpur OCP, Lakhanpur Area
Please refer Tender documents.
6 documents required · 6 mandatory
₹96,700
22 Aug 2023
13 Jun 2023
7 Jul 2023
13 Jun 2023
3 Jul 2023
14 Jun 2023
13 Jun 2023 - 22 Jun 2023
Amount
Supply of 13 mtr long RS Joist pole 152 x 152 mm.
Supply of swaged type Steel tubular pole. Tubular steel poles shall be conforming to lS 2713/80{Part 1 & 2) with amdt No-1 latest, Designation of Tubular steel poles as per Table 2 ot lS 2713/80 part-2 with amdt No 1 - 410SP-48, Length of Tubular steel poles (Metre)-10, Coating on the tubular steel poles-Bitumen coated as per clause 13. 1 of lS:2713 part 1/1980, BIS Marked, Type of steel poles- Swaged (SP), Finials, Base plates and taper plug shall be as Per clause 15 of lS 2713(Part-l)/1980 , Grade of steeltube, as per lS 1161/1998- YST 240
Erection of Joist(Size-152mm x 152mm) length exceeding 12 mtrs but not exceeding 16 mtrs in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling and secured with holding clamps, bolts, nuts, etc. as required. (Pit size- 0.8 x 0.8 x 2.5 mtr, Concrete-0.4 cu. mtr).
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. -Above 8.0 metre and upto 11.0 metre
Supply of Aerial Bunched Cable, Governing specifictions-As per IS:14255:1995 latest, Aerial Bunched cables Working voltages- Up to and including 1100 Volts, Cable suitable for use on 3 Phase AC system, ISI Marked-Yes, Type of Insulation - (as per Cl.5.1 Table 1 and Table 2 of IS:14255:1995 latest)-Crosslinked Polyethylene compound, Colour of insulation-Black, Conductor material for Phase conductor-Aluminium H2 Grade as per IS:8130:1984 latest, Conductor material for Messenger (Neutral) conductor-Heat treated Aluminium-magnesium-silicon alloy wire as per IS:398 (Part 4):1979 latest, Nominal cross sectional area of Phase conductor (in Sq.mm) 3x95, The size of (Nominal cross sectional area) street lighting conductor (in Sq.mm) 1x16, Nominal cross sectional area of Messenger (Neutral conductor) (in Sq.mm) 1x70, Manufacturer's identification throughout the length of cable As per Cl.12.1 of IS:14255:1995, Packing and marking As per Cl.13 of IS:14255:1995
Erection of Aerial Bunch Cable insulating, fixing, fitting and binding as required. Size- 95 sq.mm
Supply of suspension clamp with nut, bolt and washer Compatible with Swaged Type Steel Tubular pole, 10 mtr length designated as 410, SP-48
Supply of dead end clamp with nut, bolt and washer Compatible with Swaged Type Steel Tubular pole, 10 mtr length designated as 410, SP-48
Supply of pole clamp with nut, bolt and washer Compatible with Swaged Type Steel Tubular pole, 10 mtr length designated as 410, SP-48
Supply of J Hook Clamp with nut, bolt and washer Compatible with Swaged Type Steel Tubular pole, 10 mtr length designated as 410, SP-48
Erection of Suspension clamp/dead end clamp/Pole clamp/J Hook on pole Compatible with Swaged Type Steel Tubular pole, 10 mtr length designated as 410, SP-48.
Supply of conductor having nominal size - 22 sq. mm(as per IS:398 Part IV). Aluminium alloy stranded conductor and aluminium - magnesium - silicon type (AAAC) for over head transmission purpose conforming to IS:398 Part IV/1994 with amendment no. 1, (Reaffirmed 2004). ISI Marked. Packing on drum conforming to IS:1778/80.
Supply of conductor having nominal size- 125 sq. mm(as per IS:398 Part IV). Aluminium alloy stranded conductor and aluminium - magnesium - silicon type(AAAC) for over head transmission purpose conforming to IS:398 Part IV/1994with amendment no. 1, (Reaffirmed 2004). ISI Marked. Packing on drum conforming to IS:1778/80.
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required.(1236 X 0.06 Kg/mtr =74.16 Kg)
Erection of AAA conductor of 125 Sq. mm. diameter including binding etc. as required. (3800 X 0.342 Kg/mtr =1299.6 Kg)
Supplying of two lengths of channel iron 100 mm X 50 mm X 6 mm (9.56 kg per metre) double pole cross arm for three wire 33 KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts, washers etc and painting with primer and finish paint as required.
Supplying and erection of a set of cross bracing frame work for 33 KV over head line double pole structure having four members fabricated out of 65 mm X 65 mm X 6 mm angle iron to form a rectangle of minimum size 2400 mm width X 2800 mm height complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts, washers etc and painting with primer and finish paint as required .
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Supplying of 50 mm X 8 mm M.S. flat iron pole top bracket/ cross arm for single 11/22/33 KV over head line conductor complete with fixing clamps, bolts, nuts and washers drilling holes for insulator pins, bolts and nuts etc and painting with primer and finish paint as required .
Erection of pole top/ straight two wire/ V shape two wire, angle iron/ channel iron, cross arm on steel tubular/ rail/ PCC pole for 11/22/33 KV as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for two 33 KV over head line conductors complete with 50 mm X 50 mm X 6 mm angle iron bracket welded to the channel iron and complete with 50 mm X 6mm M.S. flat iron clamps, bolts and nuts including drilling holes for insulator pins, bolts, nuts, washers etc and painting with primer and finish paint as required.
Supplying and erection of 33 KV, 70KN composite polymer disc insulator with for over head lines with complete 3 bolt hardware fitting as clamps, bolts, nuts, washers etc. as required.
Supplying and erection of 33 KV, 10KN pin insulator composite polymer complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of galvanised stay set for 33 KV over head lines complete with 19/ 20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm thick, thimble, stay clamps, turn buckle ( 20 mm X 600 mm ), 7/ 4.00 mm dia G.I. stay wire and 33 KV strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Supply and erection of 33KV Grade, 200Amp Double Break horizontal type GOAB switch(Fix & moving contact copper suitable for 200amps) on the double pole cross arm as per direction of Engineer Incharge.
Supplying and erection of single piece nonlinear resistor type lightning arrestor suitable for 3 wire, 33 KV overhead lines with rated voltage 30 KV (rms) with a nominal discharge current rating of 10 KA (station class) and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required.
Making of chemical earth pit including earthing electrode (GI Pipe, 50mm dia & 3mtrs length) with MFC-20 (Bentonite powder) 50Kg+10 kg Graphite powder for transformer.
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Supply of G. I. Wire , SWG-8 (37.20*4) = 148.8kg
Erection of cradle guard as required.
Weaving of cradle guard as required.
Supply of LT Cable, Conformity of the specification for XLPE cable as per IS:7098 (Part 1): 1988 latest, Cables suitable for use in mines, Cables suitable for use in low temperature applications, ISI Marked, Classification of cables for improved fire performace category-01, Nominal Area of Conductor (in Sq. mm) 70, Number of core (in Nos.)-4, Material of conductor-Aluminium, Conductor material standard as per IS:8130:2013 latest, Construction of the conductor-Stranded and shaped, Insulation-XLPE, Properties of XLPE insulation as per Table 1 of IS:7098 (Part 1):1988 latest as per Table 1 of IS:7098 (Part 1):1988 latest, Colour of XLPE insulation Red,Yellow,Blue, Black,Grey,Natural,for 6 Core and above as per Cl.10.1 of IS:7098, Type of inner sheath-Thermoplastic, Type of cable-Armoured cable, Material of armouring-Galvanized steel formed wire, Type of armouring-Single strip, Number of armouring wire / strip for each size of cable (in Nos.) - 15, Outer sheath standard -Conforming to IS:5831:1984 latest, Type of outer sheath- PVC-ST2, Colour of outer sheath-Black, Manufacturer's identification on cable-as per Cl.17.1 of IS:7098 Part 1: latest, Type of sequential marking on cable -Screen printing on cable, Cable identification as per Cl.17.2 of IS:7098 Part 1: latest, Packing and marking as per Cl.18.1 and 18.2 of IS:7098 Part 1: latest,
Supply of LT Cable, Conformity of the specification for XLPE cable as per IS:7098 (Part 1): 1988 latest, Cables suitable for use in low temperature applications, ISI Marked, Classification of cables for improved fire performace category-01, Nominal Area of Conductor (in Sq. mm)-95, Number of core (in Nos.)-4, Material of conductor-Plain Copper, Conductor material standard as per IS:8130:2013 latest, Construction of the conductor-Stranded and shaped, Insulation-XLPE, Properties of XLPE insulation as per Table 1 of IS:7098 (Part 1):1988 latest as per Table 1 of IS:7098 (Part 1):1988 latest, Colour of XLPE insulation Red,Yellow,Blue,Black,Grey,Natural,for 6 Core and above as per Cl.10.1 of IS:7098, Type of inner sheath-Thermoplastic, Type of cable-Armoured cable, Material of armouring-Galvanized steel formed wire, Type of armouring-Single strip, Number of armouring wire / strip for each size of cable (in Nos.) - 14, Outer sheath standard -Conforming to IS:5831:1984 latest, Type of outer sheath- PVC-ST2, Colour of outer sheath-Black, Manufacturer's identification on cable-as per Cl.17.1 of IS:7098 Part 1: latest, Type of sequential marking on cable -Screen printing on cable, Cable identification as per Cl.17.2 of IS:7098 Part 1: latest, Packing and marking as per Cl.18.1 and 18.2 of IS:7098 Part 1: latest,
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 4 core, XLPE Cu cable of 415V grade as required : - 95 sq. Mm
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 4 core, XLPE Al cable of 415V grade as required : -70 sq. Mm
Supply and installation of Danger board(warning board) with radium sticker on APC board as per IS:2551-1982(Technical Specification enclosed). Size- 1 ft x 1.5 ft. Language to be decided by Engineer--Incharge.
Supply and erection of 33KV Grade, 400Amp Drop Out Fuse with Pin Insulator on the double pole as per direction of Engineer Incharge.
Supply of PG Clamp for Dog Conductor(125 sq. mm).
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.(3m x 3m * 0.05m) - All kinds of soil.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement: 1.5 coarse sand (zone-lll) derived from natural sources :3 graded stone aggre8ate 20 mm nominalsize de rived from natural sources) (3m x 3m x 2.5m)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Fencing with welded steel wire Fabric 75 mm x 50 mm (Suggestive) - (Providing 1.20 metre high fencing with angle iron posts 50 mm x 50 mm x 6 mm at 3 metre center to center with 0.40 metre embedded in M15 grade cement concrete corner end and every l0th post to be strutted, provided with welded steel wire fabric of 75 mm x 50 mm mesh or 75 mm x 25 mm mesh and fixed to iron posts by flat iron 50 x 5 mm and bolts etc. com in all respects
Supply and stacking of Stone aggregate (single size) 40mm nominal size at required places as per instruction of Engineer Incharge.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/S LIGHT PALACE
MANDAKINI ENGINEERING
stage.html
html • 0.04 MB
techsummary_291432.pdf
PDF • 0.34 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_291432.pdf
PDF • 1.61 MB
LOA35.pdf
PDF • 0.99 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .