Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.2 LAccepted-AOC H NO 787 22 JHANG COLONY ROHTAK 124001 | ROHTAK | HARYANA | 124001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹51.9 L+₹17.8 L (51.9%)Rejected-Finance SCF 15 HUDA COMPLEX 184 NEW IDC 124001 | ROHTAK | HARYANA | 124001 | L2 | Rejected-Finance L2 | |
| 3 | L3₹54.8 L+₹20.6 L (60.3%)Rejected-Finance | L3 | Rejected-Finance L3 | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Eligible |
| Sl No | Description | Qty | Unit | Sh. Shyam Lal Contractor L3 | Highlight Associates and Contractors L2 | Janta Electric Store L1 |
|---|---|---|---|---|---|---|
| 1.00 | [13.19]Providing and fixing galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm fixed on steel windows of standard rolled steel section, with 3 mm thick MS flat iron cover moulding of 12.5 mm width, fixed with machine screws welded complete in all respects. 0 0 0 [Through Rate] | 80 | SQM | 1,000 ₹80,000 | 1,000 ₹80,000 | 900 ₹72,000 Lowest |
| 2.00 | [22.91.7]Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc. External work 7. 65 mm dia nominal bore [Through Rate] | 12 | Per Meter | 900 ₹10,800 | 450 ₹5,400 | 400 ₹4,800 Lowest |
| 3.00 | [23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA [Through Rate] | 1 | Each | 20,000 ₹20,000 | 17,000 ₹17,000 | 6,000 ₹6,000 Lowest |
| 4.00 | [23.22.1.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.7. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 400 Amp, 50 KA [Through Rate] | 2 | Each | 22,000 ₹44,000 | 24,500 ₹49,000 | 10,000 ₹20,000 Lowest |
| 5.00 | [23.22.1.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.8. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 600 to 800 Amp, 50 KA [Through Rate] | 1 | Each | 45,000 ₹45,000 | 45,000 ₹45,000 | 18,000 ₹18,000 Lowest |
| 6.00 | [24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate] | 4 | Each | 3,000 ₹12,000 | 2,000 ₹8,000 | 1,600 ₹6,400 Lowest |
| 7.00 | [24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate] | 4 | Each | 600 ₹2,400 | 1,000 ₹4,000 | 200 ₹800 Lowest |
| 8.00 | [24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate] | 6 | Each | 2,000 ₹12,000 Lowest | 2,500 ₹15,000 | 3,000 ₹18,000 |
| 9.00 | [24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate] | 12 | Each | 7,500 ₹90,000 Lowest | 10,000 ₹1,20,000 | 8,000 ₹96,000 |
| 10.00 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate] | 18 | Each | 400 ₹7,200 Lowest | 1,000 ₹18,000 | 400 ₹7,200 Lowest |
Tender Value
₹46.5 L
EMD Value
₹92,929
Closing Date
8 Sept 2025, 5:00 pmClosed
PRAMESH Kumar
ED - Hisar
CONSTRUCTION OF 50 BEDDED TO 100 BEDDED HOSPITAL AT NARNAUND IN DISTT. HISAR (PDG. ELECTRIC SUB STATION BALANCE WORK ONLY)
2025_HRY_468579_1
2025C9655F83 3C28 4964 94C5 F52FD534132F666BAR
Open Tender
Electrical Works
Works
90 days
Narnaund
2 documents required · 2 mandatory
₹5,000
₹92,929
Yes
28 Nov 2025
29 Aug 2025
9 Sept 2025
29 Aug 2025
8 Sept 2025
29 Aug 2025
Amount
[13.19]Providing and fixing galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm fixed on steel windows of standard rolled steel section, with 3 mm thick MS flat iron cover moulding of 12.5 mm width, fixed with machine screws welded complete in all respects. 0 0 0 [Through Rate]
[22.91.7]Providing and fixing G.I. pipes complete with G.I. fittings including trenching up to 0.30m to 1.00m depth and refilling etc. External work 7. 65 mm dia nominal bore [Through Rate]
[23.22.1.5]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.5. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 200 to 250 Amp, 25 KA [Through Rate]
[23.22.1.7]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.7. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 400 Amp, 50 KA [Through Rate]
[23.22.1.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 1.8. Supply and erection of Modular case circuit breaker single pole/4 pole on existing wall/pedestal/Panel including bounding to earth and making necessary connections required to complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work. TRIPLE POLE MCCB 600 to 800 Amp, 50 KA [Through Rate]
[24.1.1]EARTHING AND LIGHTENING ARRESTOR 1. Earthing with GL earth pipe 4.5 m long and 40 mm dia with masonry enclosures on the top etc. (but without charcoal or coke and salt) as required. [Through Rate]
[24.1.2]EARTHING AND LIGHTENING ARRESTOR 2. Extra for using salt and char coal/coke for pipe earth electrode as required. [Through Rate]
[24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate]
[24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate]
[24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate]
[24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate]
[24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate]
[24.13.100]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 100. 400 Sq mm 3.5 core (Arm.) [Through Rate]
[24.13.88]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE LOOSE IN EXISTING PIPE OR TRENCHES COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 88. 240 Sq mm 3.5 core (Arm.) [Through Rate]
[24.16.5]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 5. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 120 Sq mm 3 core [Through Rate]
[24.2.10]LT CABLE 10. Supply and erection of cable route marker made of 50 cm long 10 mm dia M.S. Rod welded/riveted at the top with 10 cm dia 3 mm thick MS plate inscribed with cable word on it, having a cross arm 30 cm long of the same dia welded at the bottom, in exiting trench 45 cm below ground level. [Through Rate]
[24.2.7.6]LT CABLE 7.6. Supply and erection of suitable compression type brass cable glands for underground Cable :- 240 sqmm to Cable 3 to 32 Core [Through Rate]
[24.2.7.7]LT CABLE 7.7. Supply and erection of suitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmm Cable 3 to 3½ Core [Through Rate]
[24.3.3.1]HT CABLE 3.1. Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm [Through Rate]
[24.3.4.1]HT CABLE 4.1. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm [Through Rate]
[24.5.2.4]MISCELLANEOUS ITEMS 2.4. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 90/75 mm outer dia/inner dia [Through Rate]
[24.5.2.6]MISCELLANEOUS ITEMS 2.6. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 145/123 mm outer dia/ inner dia [Through Rate]
[9.57.3]Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 3. 150 mm diameter [Through Rate]
Supply and erection of 11 KV gang operated switch make conforming to IS with latest amendment including suitable size of copper blade erection of same on the existing `H` pole with the help of 3 No. channels of size 75 mm x 40 mm x 6 mm, 1.8 M long fixed with suitable size of MS clamp, nuts and bolts including cost of 6 No. 11 KV insulator with GI pin R.D. fuses and painting with 2 coat of approved paint and one cost of red oxide and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of work.(Excluded GST)
Street Light. HSR 31.30 VI) Supply and erection of prestressed cement concrete pole as per IS : 1678-1960. \iii) 11 meters long 152 mm x 203 mm at top and 152 mm x 368 mm at bottom with working load of 360 Kg. buried 2.20 m in ground. (Exclusive GST)
Supply and erection of Rubber Mat 1mx2mx 12mm thick suitable for 11/33 KVA as per IS No. 15652C/M/L 3017739 as per approved by Chief Electrical inspector, Govt. of Haryana (Exclusive GST)
S/E of MS bucket stand suitable for six Nos. fire buckets (but without buckets) including the cost of welding and painting with all cost of red oxide and two coat of enameled paint of red colour completion all respect. (Exclusive GST)
Supply and erection of stay wire suitable for 9/11 M. long RCC pole make out of 7/8 SWG GI wire with U type MS rod 5/8` dia duly threaded by means of angle iron of size 50 mm x 6 mm x 30 cm and 6 ft. long MS rod 5/8` dia 5` buried in the ground after fixing with cross channel size 75 mm x 40 mm x 60 cm. The stay wire will be binded on the top of the pole with help of suitable size of double U type MS clamps and stay fixed with nutsand bolts. The stay wire shall be insulated in the middle point with the help of egg. Insulator and complete with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. (Exclusive GST)
Supply and erection of 11 KV disk insulator with all labour and material required to complete the job including fixing the same on existing channels up to the entire satisfaction of Engineer-in- Charge of the work (Exclusive GST)
Supply and erection of lightening arrester module suitable for 11 KV G.O. switch with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-Charge of the work. (Exclusive GST)
S/E of Copper Strip 40X5 mm for Earthing on Surface and recess in ground including petty ,aterial i.e. Nuts Bolts, Stapples etc complete in all respect upto Entire satisfication of Engineer-in-charge of the work (Exclusive GST)
a) S/E of 1 No. 630 Amps motorised Vacumm Circuit Breaker triple pole, single break 3 position as incomer (On, Off and earth having STC capacity 20 KA for 3 seconds with copper bus bar and copper earth bar fitted with fixed type voltage indicator device as per IEC 61958-1, fully rated with earth switch, spring assisted mechanism, Red/ Green Push Button for On/ Off operation. Arc proof hinged type cable cover interlocked with earth switch. Air insulated cable boxes and boots suitable for bottom entry front termination of 3 core cable 95/120/185 Sqmm. (b) 2 Nos. 630 Amps manual Vacumm Circuit Breaker triple pole, single break 3 position as outgoing (On, Off and earth having STC capacity 20 KA for 3 seconds with copper bus bar and copper earth bar fitted with fixed type voltage indicator device as per IEC 61958-1, fully rated with earth switch, spring assisted mechanism, Red/ Green Push Button for On/ Off operation. Arc proof hinged type cable cover interlocked with earth switch. Air insulated cable boxes and boots suitable for bottom entry front termination of 3 core cable 95/120/185 Sqmm.(c) 3O/C plus IE/F self powered relay with low and high set for over current and earth fault. Relay should have LCD (16 x 2). Relay should have facility to trip the breaker from remote commands without shunt trip coil, Last 5 fault record with time stamp, battery pack replaceable from front. Make of RMU : ABB/siemens/Schneider/ Voltamp.As per approved DNIT Items no. 22. (Exclusive GST)
S/E angle iron, GI channel and GI clump GI nut and bolts of various sizes required for made the platform and G.O. switch etc. (Exclusive GST)
SITC of Co2 type Fire Extinguisher 4.5 Kgs capacity made from brand new seamless cylinder, as per ISI 7285 and CCE approval, fitted with a Discharge hose and horn and squeeze Grip type valve with initial charge as per ISI 15683:2006 specification, bearing ISI Mark.(Make - Cease fire/ Savemax/ SAFEX). (GST Exclusive)
Supply and erection of 11 KV pin insulator with pin make with all labour and material required to complete the job including fixing the same on existing channels up to the entire satisfaction of Engineer-in- Charge of the work. (Exclusive GST)
Supply, Erection, Testing, commissioning of L.T Essential Panel of 16 Guage CRCA sheet Powder coated indoor type having 1 Nos. 1000A ACB incomer and 1 No. Changeover 1000 A having complete arrangement with Aluminium Bus Bar, Protections, Metering Outgoing ACB’s and MCCB as per BOM complete as per the requirement and satisfaction of Engineer-in-charge of the work (Exclusive GST)
POWER FACTOR PANEL 400 KVAR: Supply erection, testing and commissioning of cubical type panel dust and vermin proof. L.T. automatic power factor control panel 400 KVAR capacity suitable for automatic operation and control of power factor within the set limits free standing floor mounting made out of 14 guage mild steel with channel iron base frame painted with stove synthetic light grey enamelled paint suitable for operation on 3 phase 4 wire 50 cy cle persecond 400/440 volts A.C. supply equipped with the following as per diagram attached: 1 No. automatic power factor control relay of EE Co./ LandT make.Power factor meter size 96 x 96mm of AE C15 for incomer 200 amp. triple pole moulded case circuit breaker.A set of pilot lamps (3 Nos.) phase indicating lamp of LandT make.Iron clad bus bar chamber suitable for 200 amp. 440 volts having 4 No. copper bars of cross section 25 mm x 5mm duly tinned and insulated with PVC sleeves.as per approved DNIT item no. 20. C15(Exclusive GST)
Supply Erection testing and Commissioning of 11 KV HT metering panel complete with C.Ts P. Ts. Cubical and electronic meter with accuracy class as per requirement/approved by DHBVN at the time of installation, consisting of the following. (As per Approved by DHBVPNL). Cubical panel free standing floor mounting type made out of sheet steel 14 SWG CRCA sheet with channel iron base frame spray painted with strong synthetic light grey enamel paint as per size and design approved by the DHBVNL 3 Nos. 11 KV CTS of rating as approved by DHBVNL for indoor installation of appd. Make of 1 Nos. 11 KV PTs 11000/110 Volts Oil filled suitable for indoor installation of approved make DHBVNL. Space for Digital Electronic Meter 3 phase 4 wires recording in KWH and rating and accuracy as by DHBVNL with push button display operating system of different kind of readings. The cubical panel will be completed in all r espectincluding intter connection, internal wiring with PVC copper cable, its testing and approval of all item by DHBVNL including cost of all testing/ approval charges of all items of DHBVNL with a guarantee of one year from the date of commissioning including cost of all labour and material required to complete the job but excluding the cost electronic meter in all respect up to the entire satisfaction of the engineer in charge of the work. (Exclusive GST)
S/E of fire bucket 9 Ltrs Capacity of G.I. sheet of 24 gauge write with ` FIRE` as per fire pecification. (Exclusive GST)
Highlight Associates and Contractors (BID ID -1330429)
Sh. Shyam Lal Contractor (BID ID -1332022)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .