work of partial modification in HVAC services which includes reconfiguration of AHUs with additional provision of redundancy, manufacturing and Rerouting of ducts with insulation, rerouting of chilled/Hot water lines and raising of AHUs enabling wate
2023_DBTEC_764731_1
CIAB/7(98)/2021-Works
Open Tender
Electrical Works
Item Rate
70 days
Mohali
Please refer Tender documents.
2 documents required · 2 mandatory
₹1
Yes
CIAB
₹50,000
Yes
13 Sept 2023
1 Aug 2023
23 Aug 2023
1 Aug 2023
22 Aug 2023
1 Aug 2023
Dismentalling and reinstallation of existing AHU of capacity 10500 CFM rasied on the MS platform stand specifically customised and manufactured for the purpose as per on site conditions.
Supply and Installation required on site for the of MS Steel work for AHU Pletform as per site conditions and proposed design.
Supplying and carrying out single layer polycarbonate sheet work for AHU & Duct Covering Sheet as per site conditions or proposed design.
Buy Back of ducts and pipes removed from the site which shall be replaced with the new ones as per site conditions or proposed design.
Supply, installation, testing and commissioning of complete set of High rangeability control valve or Pressure independant control valve, kit comprising of Two Way Control Valve of Brass construction rotary / ball type for DN15 and DN32 of PN25 rating with screwed connections. DN 40-DN150 shall be C.I body of PN16 ratings, motorised modulating actuators with linear stroke of minimum 15 mm, LCD display digital controller(BMS compatible),three nos NTC sensors with complete wiring with in AHU room,one thermowell,one power supply unit of 230Vac/24Vac.Control box for mounting Digital controller and power supply unit and 10 Amps Double pole MCB should be also provided.The valve size shall be suitable for pipe size/coil TR capacity. (Make - Anergy/Belimo/Siemens) 50 mm dia
Supplying, laying/ fixing of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note : The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 100mm dia. (50mm thick insulation)
Supplying, laying/ fixing of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note : The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 80mm dia. (50mm thick insulation
Supplying, laying/ fixing of following nominal sizes of chilled water piping plumbing inside the building (with necessary clamps, vibration isolators and fittings but excluding valves, strainers, gauges etc.) duly insulated with fire retardant quality expanded polystrene moulded pipe section of density 20 kg/cu.m after a thick coat of cold setting adhesive (CPRX compound) wrapping with 500g polythene faced hessain and finally applying 0.63mm aluminium sheet cladding complete with type3 , grade 1 roofing feltstrip(as per IS:1322 as amended up to date ) at joints repairing of damage to building etc. as per specifications and as required complete in all respect. Note : The Pipes of sizes 150mm & below shall be M.S. ‘C’ class as per IS : 1239 and pipes size above 150mm shall be welded black steel pipe heavy class as per IS: 3589, from minimum 6.35mm thick M.S. Sheet for pipes upto 350 mm dia. and from minimum 7mm thick MS sheet for pipes of 400 mm dia and above. 65mm dia. (50mm thick insulation)
Supply , installation , testing and commissioning of condensate drain water piping of GI 'Medium' class complete with Medium Class fittings like elbows, tees, reducers bends, MS flanges, supports, welding, painting 25 mm thick EPS insulation etc. as required conforming to standard specifications and of following sizes. 25 mm dia pipe
Supply , installation , testing and commissioning of condensate drain water piping of GI 'Medium' class complete with Medium Class fittings like elbows, tees, reducers bends, MS flanges, supports, welding, painting 25 mm thick EPS insulation etc. as required conforming to standard specifications and of following sizes. 32 mm dia pipe
Supply , installation , testing and commissioning of condensate drain water piping of GI 'Medium' class complete with Medium Class fittings like elbows, tees, reducers bends, MS flanges, supports, welding, painting 25 mm thick EPS insulation etc. as required conforming to standard specifications and of following sizes. 50 mm dia pipe
Supply, installation, testing and commissioning of auto air vent valve of following sizes:- 12 mm dia auto air vent valve
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and pecifications of following sheet thickness complete as required. Thickness 0.63 mm sheet
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and pecifications of following sheet thickness complete as required. Thickness 0.80 mm sheet
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and pecifications of following sheet thickness complete as required. Thickness 1.00 mm sheet
Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and pecifications of following sheet thickness complete as required. Thickness 1.25 mm sheet
Supplying, Fixing,testing and commissioning of Duct dampers in supply air duct/main branch and return air path as and where required of required sizes i/c control wiring,the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specifications. Damper
Supplying and fixing of following thickness of Acoustic Insulation Inside the Duct with Engineered K-Fonik Open Cell Nitrile Rubber with Density 140 - 180 Kg/m3 & shall be fibre free. The material shall have a thermal conductivity not exceeding 0.047 W/m.K @ 20 Deg. C & shall conform to Class 1 rating for surface spread of Flame in accordance to BS 476 Part 7. The insulation shall pass Air Erosion Resistance Test in accordance to ASTM Standard C 1071-05 (section 12.7), from an independent testing agency & should have built-in Ultra-Fresh Anti-Microbial Protection, and should pass Fungi Resistance as per ASTM G21, UL 181 & E2180. To be applied using recommended K414 Class O low VOC Adhesive 15 mm thick open cell nitrile rubber.
Supply & Installation of Thermal Insulation on ducts Exposed/ not exposed to sunlight using K-FLEX ST Closed Cell Microcellular Elastomeric Nitrile Rubber of specified thicknesses having density between 40 to 60 Kg/m3. Thermal conductivity shall not exceed 0.035 W/m.K at an average temperature of 0 degree C, FM approved. The insulation shall have fire performance such that it passes minimum fire rating Class 1 as per BS 476 Part 7 for surface spread of flame and also pass Fire Propagation requirement as per BS476 Part 6 to meet the Class ‘O’ Fire classification. Water vapour permeability shall not exceed 0.024 Perm inch (2.48 x 10-14 Kg/m.s.Pa) i.e. Moisture Diffusion Resistance Factor or ‘µ’ value should be minimum 7,000 & with factory laminated Aluminium glass cloth backing of 7 micron foil / FR Glue / 90 GSM glass cloth combined with high performance flame retardant solvent adhesive & having tensile strength of 25N/25mm . To be applied on duct using recommended K414, Class O low VOC Adhesive. 25 mm thick (Class O) Foil for Supply / Return Air Duct
Supply, laying, testing and commissioning of power and control cabling, as per Standard specification including end termination as required. Power Cabling (FRLS) insulated and PVC sheathed, armoured, Aluminium Conductor of 1.1 KV grade on cable trays). 3C x 10Sq. Mm
All type of civil work required for comissioning for complete work
kausnvi International Pvt Ltd
Industrial Project and Products Company
CHILL POINT ENGINEERS PVT LTD
PROJENIX PRIVATE LIMITED
Harvex Consulyancy Services
Aircon Technique Pvt Ltd
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .