Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹31.4 L+₹2.7 L (9.56%)Rejected-Finance BHU | L2 | Rejected-Finance Other than lowest | |
| 3 | L4₹32.2 L+₹3.5 L (12.0%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 4 | L4₹33.1 L+₹4.4 L (15.4%)Rejected-Finance 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹33.8 L+₹5.1 L (17.8%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | Bharat Sales Corporation L6 | PAWAN COOL CORPORATION L3 | anand enterprises L1 | VEE KAY ENTERPRISES L5 | Lalta Prasad vijay kumar Forwarding Agency L2 | PRAGYA GREENTECH L8 | santosh electronics L4 | AARADHIRAJ ASSOCIATES L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge. | 578 | Cum | 130 ₹75,140 | 125 ₹72,250 | 100 ₹57,800 | 90 ₹52,020 Lowest | 120 ₹69,360 | 260 ₹1,50,280 | 200 ₹1,15,600 | 90 ₹52,020 Lowest |
| 2.00 | Supply and filling fine ganga sand to the full width of trench for cushioning of cable for cable protection including spreading and punning down complete all as specified and directed. Note: Punned thickness of sand after laying shall be measured for payment purpose. | 174 | Cum | 375 ₹65,250 | 565 ₹98,310 | 250 ₹43,500 Lowest | 250 ₹43,500 Lowest | 450 ₹78,300 | 800 ₹1,39,200 | 420 ₹73,080 | 450 ₹78,300 |
| 3.00 | M&L foe ell burnt old size bricks, sub class B brick laid dry flat with width equal to length of whole brick, as cable protection complete all as specified and directed. | 18.61 | 1000 Per Nos | 4,000 ₹74,440 Lowest | 6,275 ₹1,16,777.75 | 5,000 ₹93,050 | 6,000 ₹1,11,660 | 5,000 ₹93,050 | 8,000 ₹1,48,880 | 4,400 ₹81,884 | 5,000 ₹93,050 |
| 4.00 | Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete etc all as specified and directed. | 247 | Cum | 40 ₹9,880 | 35 ₹8,645 | 50 ₹12,350 | 30 ₹7,410 Lowest | 60 ₹14,820 | 80 ₹19,760 | 55 ₹13,585 | 35 ₹8,645 |
| 5.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeking 25 cm in soft & loose soil complete etc all as specified and directed. | 331 | Cum | 70 ₹23,170 | 45 ₹14,895 | 60 ₹19,860 | 35 ₹11,585 | 25 ₹8,275 Lowest | 70 ₹23,170 | 50 ₹16,550 | 29 ₹9,599 |
| 6.00 | Plain cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregates ) as in foundation filling and mass concrete complete all specified and directed. | 2 | Cum | 4,000 ₹8,000 | 4,525 ₹9,050 | 3,000 ₹6,000 | 2,000 ₹4,000 Lowest | 3,800 ₹7,600 | 8,000 ₹16,000 | 5,000 ₹10,000 | 3,000 ₹6,000 |
| 7.00 | Plain cement concrete (1: 2:4) type B-1 (using 20mm graded crushed stone aggregates ) as in stay filling or pole coping etc including necessary form work for rough finished surfaces complete all specified and directed. | 2 | Cum | 5,600 ₹11,200 | 4,765 ₹9,530 | 3,500 ₹7,000 | 1,500 ₹3,000 Lowest | 4,200 ₹8,400 | 7,500 ₹15,000 | 6,000 ₹12,000 | 3,500 ₹7,000 |
| 8.00 | S&F of GI tubing light grade 50mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc all as specified and directed. | 60 | Rm | 200 ₹12,000 Lowest | 275 ₹16,500 | 200 ₹12,000 Lowest | 300 ₹18,000 | 280 ₹16,800 | 420 ₹25,200 | 400 ₹24,000 | 300 ₹18,000 |
| 9.00 | S&F of GI tubing light grade 100mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc all as specified and directed. | 12 | Rm | 500 ₹6,000 | 675 ₹8,100 | 250 ₹3,000 Lowest | 400 ₹4,800 | 490 ₹5,880 | 900 ₹10,800 | 700 ₹8,400 | 450 ₹5,400 |
| 10.00 | Supply and lay testing and commissioning of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded Aluminium conductor of size 6 Sqmm 2 core. laid in trench/ duct / along pole/wall etc including suitable size lugs, glands,Nut, bolts, washers & insulation tape etc making connection complete incl taking out ot old unsericeable/damaged cable complete etc all as specified directed.
Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it. | 60 | Rm | 120 ₹7,200 | 125 ₹7,500 | 70 ₹4,200 Lowest | 100 ₹6,000 | 105 ₹6,300 | 105 ₹6,300 | 90 ₹5,400 | 111 ₹6,660 |
Tender Value
₹38.8 L
EMD Value
₹77,660
Closing Date
10 Jan 2026, 6:00 pmClosed
GE(AF) EM Chakeri
GE(AF) EM Chakeri Kanpur
UP-GRADATION OF LT CABLE, ELECTRIC DISTRIBUTION SYSTEM CABLES, PANELS AND ASSOCIATED WORKS AS PER INCREASED LOAD FOR MD ACCN AT N-2, CHARARI, KAZIKHEDA AND RAMADEVI AT AFS KANPUR
2025_MES_745553_1
8785/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Area under GE(AF) EM Chakeri
As per tender document
9 documents required · 9 mandatory
₹500
GE(AF) EM Chakeri
₹77,660
Yes
15 Apr 2026
20 Dec 2025
15 Jan 2026
22 Dec 2025
10 Jan 2026
5 Jan 2026
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in soft/loose soil complete all as specified and directed by Engr-in-Charge.
Supply and filling fine ganga sand to the full width of trench for cushioning of cable for cable protection including spreading and punning down complete all as specified and directed. Note: Punned thickness of sand after laying shall be measured for payment purpose.
M&L foe ell burnt old size bricks, sub class B brick laid dry flat with width equal to length of whole brick, as cable protection complete all as specified and directed.
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete etc all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeking 25 cm in soft & loose soil complete etc all as specified and directed.
Plain cement concrete (1:3:6) type C-2 (using 40mm graded crushed stone aggregates ) as in foundation filling and mass concrete complete all specified and directed.
Plain cement concrete (1: 2:4) type B-1 (using 20mm graded crushed stone aggregates ) as in stay filling or pole coping etc including necessary form work for rough finished surfaces complete all specified and directed.
S&F of GI tubing light grade 50mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc all as specified and directed.
S&F of GI tubing light grade 100mm dia with all fittings laid in trenches/fixed on wall/ceiling including dismantling of old pipe etc all as specified and directed.
Supply and lay testing and commissioning of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded Aluminium conductor of size 6 Sqmm 2 core. laid in trench/ duct / along pole/wall etc including suitable size lugs, glands,Nut, bolts, washers & insulation tape etc making connection complete incl taking out ot old unsericeable/damaged cable complete etc all as specified directed. Note : The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Description all as per item No.10 above but cross sectional area 10 Sqmm 4 core complete all as specified and directed.
Description all as per item No.10 above but cross sectional area 16 Sqmm 4 core complete all as specified and directed.
Description all as per item No.10 above but cross sectional area 25 Sqmm 4 core complete all as specified and directed.
Description all as per item No.10 above but cross sectional area 35 Sqmm 3.5 core complete all as specified and directed.
Description all as per item No. 10 above but cross sectional area 70 Sqmm 3.5 core complete all as specified and directed.
Description all as per item No. 10 above but cross sectional area 90 Sqmm 3.5 core complete all as specified and directed.
Description all as per item No. 10 above but cross sectional area 120 Sqmm 3.5 core complete all as specified and directed.
Description all as per item No. 10 above but cross sectional area 150 Sqmm 3.5 core complete all as specified and directed.
Description all as per item No. 10 above but cross sectional area 185 Sqmm 3.5 core complete all as specified and directed.
Description all as per item No. 10 above but cross sectional area 240 Sqmm 3.5 core complete all as specified and directed.
Description all as per item No. 10 above but cross sectional area 300 Sqmm 3.5 core complete all as specified and directed.
Supply laying and fixing testing and commissioning LT oherhead XLPE insulated AB cable 3 core x 70 sqmm 1 core x 35 sqmm phase cires twisted around aluminium alloy insulated messenger conductor confirming to IS 14255 including indentification of phase by ridges provided on the insulation of phase conductors 1 ridge for the 1st phase, 2 Ridges for the 2 nd phase, 3 Ridges for the 3rd phase and 4 Ridges for neutral including accessories like Anchor clamp, Suspension clamp, line connector, service clamp, insulation piercing connectors, (IPC for tap from bare lines) dead end, suspension clamp, I hook etc complete incl taking out old unsericeable/ damaged UG cable complete etc all as specified directed. Note:- The cost of thimbles/lugs and cable gland etc is incl in quoted rate and no extra payment will be made for it.
Supply and fixing in repair 1.5 Sqmm three core PVC insulated copper conductor wire for street/security light terminal box, including suitable size of bottle lugs etc complete all as specified and directed
M&L for making horizantal boring 60cm deep anually below top of road crossing for passing of 40 to 50mm dia GI pipe including making good damaged portion of road etc. complete all as specified and directed by EIC.
S&F Sintex SMC junction box GSJB-3020 of size 340x280x130mm with locking arrangement, shockproof and rustproof, rot-proof and termite resistance, cable entry from bottom and side, 100% weather proof for outdoor installation suitable for pole mounting. tamper proof, restricts unauthorised tapping, IS 11731, IP 66/67 suitable for 16-35 sqmm 3.5 core aluminium cable including 1 No MCB 6 Amp. 04 Nos aluminium bus bars of suitable size mounted on epoxy insulators with holes for incoming and outgoing cables and connector block two way and fixing with flat aluminium clamps not less than 25 mm x 3 mm with suitable size nuts, bolts and washers inside and outside looping box complets as directed.
Supply, installation, commissioning and testing in replacement of LT feeder piller box outdoor type, IP 54 protection made out of 3 15mm thick CRCA sheet metal, double door type and sitable MS angle iron base frame, cubical type floor mounted 3 phase 4 wire, 415V properly insulated aluminium bus bar-04 Nos having capacity 400 Amps on phase and neutral, dustand vermin proof, both side open with locking arrangement, danger board plate. duly painted internally and externally with powder coated, RYB indication lamp with Digtal multifunction meter, suitable size plate form built with brick work in CM (1:4) 15mm thick plastering in CM (16), 0.6Mtrs height from GFL, incl lugs, gland, thimble and nut bolts etc electric connection complete etc all as specified and directed by EIC.
Taking out carefully, shifting and reinstalling of LT Panel to a distance not more than 5 kms from any place and connecting including panel shall be mounted on brick work plate from of size 250x400x600mm in two number duly plasterd and PCC coping work om top surface height shall be 6. mtr above the GL and 0.40 mtr all aroung the FPB complete all as specified and directed by EIC
S & F Galvanized anti corroded weather proof octagonal electric poles 7 Mtrs long top mounting on foundation complete with base plate as per IS 2713 for tubular steel poles and IS 4759 for hot-dip galvanization, including PCC foundation as per SSR provision and directed with 1200 mm long arms bracket, tapper plug, bolts, nuts and screws etc as specified complete including taking out existing RCC/damaged rusted MS pole and street light bracket complete all as specified and directed by Eng in Charge. Note:- (1) Rate quoted by contractor deemed to be inclusive of required excavation work (2). Rate quoted by contractor deemed to be inclusive of required PCC(1:2:4) type B2 and foundation etc work complete.
Earthing complete with galvanised steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 mtr below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to galvanised iron strip 25×4mm means of bolts, nuts check nut & washers of galvanised iron or steel & connected to main switch including complete excavation and earth work in soft/loose soil and disposal of surplus soil to a distance not exc 50 meters, PCC Chamber (1:3:6) type C-2 precast RCC cover with frame, funnel wire mesh, 20mm bore light grade galvanised iron or steel pipe for water, charcoal or coke and salt in alternative layers of 15cm compacted thickness all round the earth electrode complete alll as shown in electrical plate No 3 of SSR part-I including welding with suitble electrode and testing complete all as directed. NOTE :- (i) Main earthing strip from earth plate electrodeto test point upto length of 7.5 mtrs length shall deem to be included in the unit rate quoted against this item. (ii) M&L Tubing GI med grade 40mm dia for protection of earthing strip and passing the Road/passes and etc.shall deem to be included in the unit rate quoted against this item.
Supply, installation, comissioning and teasting in replacement of out door type LT panel of approved make, CPRI approved, make, fabricated out of 3.15mm thick CRCA steel sheet powder coated, double door with and incl MS angle iron (40x40x6mm) base frame, cubical type floor mounted, dust and vermin proof, both side open and locking arrangement, danger board plate,Cable gand, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit,chamber for aluminium bus bars including aluminium busbars 4 Nos,375 Amp on phase & neutral, 415 volts, properly insulated aluminium bus bar capacity insulated with colored PVC sleeves mounted on suitable insulators and separators, holes drilled for connections including panel shall be mounted on brick work plate from of size 250x400x600mm in two number duly plasterd and PCC coping work om top surface height shall be 0.60 mtr above the GL and 0.40 mtr all aroung the FPB complete all as specified and comprising of the followings:-
Supply, installation, comissioning and teasting in replacement of out door type LT panel of approved make, CPRI approved, make, fabricated out of 3.15mm thick CRCA steel sheet powder coated, double door with and incl MS angle iron (40x40x6mm) base frame, cubical type mounted, dust and vermin proof, both side open and locking arrangement, danger board plate,Cable gand, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit,chamber for aluminium bus bars including aluminium busbars 4 Nos,200 Amp on phase & neutral, 415 volts, properly insulated aluminium bus bar capacity insulated with colored PVC sleeves mounted on suitable insulators and separators, holes drilled for connections including panel shall be mounted on brick work plate from of size 250x400x600mm in two nmber duly plasterd and PCC coping work om top surface height shall be 0.60 mtr above the GL and 0.40 mtr all aroung the FPB complete all as specified and comprising of the followings:-
INCOMING -(a) MCCB 4 Pole, 415 V, adjustable thermal setting, Ics 100% Icu, 125 Amps with breaking capacity 25 KA-01 No OUTGOING : (a) MCB 4 Pole, 415 V, 32 Amps with breaking capacity 10 KA-10 No. (b)) Voltmeter, electronic, digital type, AC 50 Hz-1 No (c) Ammeter electronic, digital type, 0-400 amps, AC, 50 Hz-1 No. (d) Current transformer 200/5 amps rating, AC, 50 Hz-3 Nos. (1) Phase indication LED lamps-3 Nos (RYB).
Supply, installation, comissioning and teasting in replacement of out door type LT panel of approved make, CPRI approved, make, fabricated out of 3.15mm thick CRCA steel sheet powder coated, double door with and incl MS angle iron (40x40x6mm) base frame, cubical type mounted, dust and vermin proof, both side open and locking arrangement, danger board plate,Cable gand, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit,chamber for aluminium bus bars including aluminium busbars 4 Nos,525 Amp on phase & neutral, 415 volts, properly insulated aluminium bus bar capacity insulated with colored PVC sleeves mounted on suitable insulators and separators, holes drilled for connections including panel shall be mounted on brick work plate from of size 250x400x600mm in two number duly plasterd and PCC coping work om top surface height shall be 0.60 mtr above the GL and 0.40 mtr all aroung the FPB complete all as specified and comprising of the followings:-
Supply, installation, comissioning and teasting in replacement of out door type LT panel of approved make, CPRI approved, make, fabricated out of 3.15mm thick CRCA steel sheet powder coated, double door with and incl MS angle iron (40x40x6mm) base frame, cubical type mounted, dust and vermin proof, both side open and locking arrangement, danger board plate,Cable gand, bottom with detachable plates, front and rear with hinged type door and locking arrangements, chamber for cable entry and exit,chamber for aluminium bus bars including aluminium busbars 4 Nos,300 Amp on phase & neutral, 415 volts, properly insulated aluminium bus bar capacity insulated with colored PVC sleeves mounted on suitable insulators and separators, holes drilled for connections including panel shall be mounted on brick work plate from of size 250x400x600mm in two number duly plasterd and PCC coping work om top surface height shall be 0.60 mtr above the GL and 0.40 mtr all aroung the FPB complete all as specified and comprising of the followings:-
stage.html
html • 0.06 MB
techsummary_834828.pdf
finance_834828.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 3.03 MB
8785E8_Tender_1.pdf
Tender Documents • 0.78 MB
BOQ_834828.xls
BOQ • 0.41 MB
8785E8_CreditSchdule_1.pdf
Additional Documents • 0.17 MB
Tender_Acceptance_Letter.pdf
Additional Documents • 0.08 MB
Workdetails.pdf
Additional Documents • 0.09 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .