Executive Engineer (Elect)
Room No-25, Ground Floor, T.E. Building Kidwai Bhawan MTNL, New Delhi
Refurbishment/ Renovation/ Repairing work of (2x178 TR and 2X120 TRH) central AC plant at TE Bldg JLN Marg, New Delhi.
2022_MTNL_701882_1
EE(E)KBN/2022-23/20-07-2022/21
Open Tender
Electrical Works
Item Rate
365 days
Kidwai Bhawan
Please refer Tender documents.
8 documents required · 8 mandatory
₹590
MTNL Delhi
₹77,299
1 Aug 2022
20 Jul 2022
29 Jul 2022
20 Jul 2022
28 Jul 2022
20 Jul 2022
Amount
Dismantling of faulty/worn-out screw compresssor with motor from AC chilling unit of 120 TR capacity, lifting & shifting it with the help of chain pulley block and heavy labour from terrace of building to ground and transporting the same from site to the workshop, replacement of entire bearings i/c central bearings with the use of hydraulic machine and alignment of central shaft including replacement of defective parts, accessories such as internal/external filters, gaskets, O- rings, gauges, gas valve, checking & replacing of other related components, making the compressor operational, bringing the compressor at site and refixing it on the chiller machine, testing & commissioning etc. complete as required.
Repairing. of energy efficient Heat-Exchanger fan complete with blades, hub, shaft etc. capable for free air-delivery of 20000CFM having electric motor of 3.5 HP, F Class insulation, IP 66 protection suitable for 24 hrs. continuous outdoor-duty operation on 415V +/- 5%, 50Hz, 3 phase a.c. supply including dismantling the existing faulty/burnt-out irheat-exchanger fan with all accessories & motor and fixing it after repairing works i/c testing commissioning etc as reqd .
Rewinding of 12.5 HP, 415V +/- 5%, 50 Hz, 3 phase AC TEFC Squirrel cage induction motor of hot water horizontal split casing pump set with suitable gauge of copper wire, F- class insulation, varnishing, re-fitting the motor-pump set i/c proper alignment, electrical-connections, testing etc. complete as required. (Make: M/s Beacon Flow Rate - 252 USGPM/Head : 30 Metre)
Rewinding of 10 HP, 415V +/- 5%, 50 Hz, 3 phase AC supply, TEFC squirrel cage induction motor of single stage horizontal centrfugal, monoblock pump set with suitable gauge copper wire, F- class insulation, varnishing, re-fitting the motor-pump set i/c proper alignment, electrical-connections, testing etc. complete as required. (Make: Kirloskar)
Repairing & refurbishment of 20 HP chilled water pump i/c the attached coupling, bushes, bearings etc. and dismantling the same from base frame and transporting to workshop for repair & refurbishment, bringing the repaired pump set back at site, installation, testing and commissioning, providing heat-insulation of the pump-set etc complete as required. (Make: M/s Beacon, Model: BWC 80/100)
Replacement and faulty display card in microprocessor based controller fixed in AC chilling units i/c setting all parameters, safety set point, controls i/c checking and carrying out re-wiring to make the controller operational etc. complete as required. (Make: Carel Model:PCO1)
Replacement and filling of following components in fluid/electrical/mechanical/refrigerant circuit of central air-conditioniong system etc. complete as required: a) Sensor Control (Thermostat)
LP Control Switch/Sensor
HP Control Switch/Sensor
Capillary (flexible type)
Water flow switch
Thermometer (Range: -20° C to 50° C, Make - H Guru/SS)
Syphon with valve
Transducer (HP/LP)
Replacement and fixing of V Belts of Air handling units of sizes ranges as under : a)B43
Replacement and fixing of V Belts of Air handling units of sizes ranges as under :a) A 24
Replacement of water pressure gauge in chilled/condensor water pipeline of central AC Plant. (Range : 0 to 10 Kg/cm2, Make : H Guru, )
Refilling/Top up of polyester oil (POE oil) for compressor of 120TR /172TR AC chiller with removing covers, gaskets and emptying of existing oil etc. complete as required. (Make & Grade: Bitzer BSE 32)
Re filling/top up of following refrigent gas (R-134A)) in the existing chilling machines of central AC plant unit
Charging of R-22 refrigerant gas in the existing package/ ductable/ sensicool/ tower/ cassette/ split/ window AC unit after purging the air, testing and commissioning the units etc. complete as reqd. a) ) 1.5 TR / 2.0 TR (nominal capacity) AC unit.
b) 4.0 TR / 5.0TR / 5.5 TR (nominal capacity) AC unit.
c) 7.0 TR / 7.5 TR (nominal capacity) AC unit (each Circuit).
d) 8.5 TR / 9.0 TR (nominal capacity) AC unit (each Circuit).
P/F of following size soft/hard copper pipe including cutting, bending, jointing, brazing etc as reqd. for hot and liquid refrigerant line complete as required as per site requirement. a) 7/8" or 6/8"
P/F of drain arrangement for AC units with following pipe i/c Tee, Union, Socket & Elbow etc as required. a) 40 mm dia medium class PVC pipe.
b) 25 mm diamedium class PVC pipe.
Providing and fixing of 6mm thick cross linked polyethylene insulation for drain / copper piping in order to protect it from air borne impurities complete as reqd. as per site location.
Replacement of dia Strainers with filter for AC plant etc. complete as required. ( Make - Emerald/SS)
Part Renovation/Repairing of Soft Starter of AC chiller having built-in safeties, cards etc with replacement of components such as thyristor, electrical parts, programming of cards and replacement of display system etc as reqd
Replacement of micro processor controller card in controller panel of chilling machines of central AC plant (Make - Carel, Model: PCO1.) including disconnecting and removing of the existing faulty controller card & handing over to the department.
Replacement of butterfly valve of 125mm NB i/c dismantling of non operational valve from chilled water pipeline, providing and fixing new flanges, gaskets, nut bolts, thermal insulation etc. complete as required. Make:-M/s Advance
Replacement of motorized butter fly valve of 300mm dia in chilled water pipeline i/c dismantalling of non operational valve from existing pipeline with replacing with new one along with flanges, nut bolts i/c removing thermal job etc and making the same good etc. complete as required. (Make: Advance/Audco/SS)
Refilling/topup replacement of existing defective sensor of controller of AC Chiller for various functions of components and control wiring as per diagram including software programming with modules and display features of temperature, HP/LP, sensors etc complete as required.
Refilling/Topup of Solution (MEG) of requisite density in the thermal storage tank having two no of storage tank installed in lower basement i/c the work comprising of desilting flushing the tank with pneumatic arrangement and also carryout special jobs related to AC system etc as reqd.
Dismantling the metallic cover of condensing system of 120TRH central plant system for licking condensor coil including repairing welding, brasing the U bends, hadders of copper pipe and making the system operational etc. complete as reqd. (2X60TRH)
C- Shine Chemical/Alakaline based chemical for cleaning of cooling/heating/DX coils of HVAC System with checking conditions of coil i/c combing for enhancing the life span of coils and applying chemical as per recommendations of manufacturer to remove dust/dirty particles from the surface and inner part of aluminium fins and copper tubing etc (Make - Floricon/C-Shine)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .