Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.5 LAccepted-AOC SHED NO 9 TAHLIWAL DISTT UNA H P | L1 | Accepted-AOC Bidder has been place L1 | |
| 2 | L2₹6.8 L+₹30,451.67 (4.66%)Rejected-Finance 1ST FLOOR AMRIT EDUCATION GOVT DEGREE COLLAGE ROAD DHALIARA TEHSIL DEHRA DISTT KANGRA H P | KANGRA | HIMACHAL PRADESH | 175013 | L2 | Rejected-Finance The bidder is replaced L2 and hence not qualified for bid | |
| 3 | L3₹7.1 L+₹51,573.08 (7.89%)Rejected-Finance | L3 | Rejected-Finance The bidder is replaced L2 and Hence not qualified for Bid | |
| 4 | L4₹7.6 L+₹1.0 L (15.5%)Rejected-Finance | L4 | Rejected-Finance The bidder is replaced L4 and hence not qualified for bid | |
| 5 | L5₹8.0 L+₹1.4 L (21.7%)Rejected-Finance BILASPUR | L5 | Rejected-Finance The bidder is replaced L5 and hence not qualified for bid |
Tender Value
Refer Docs
EMD Value
₹7,930
Closing Date
17 Feb 2022, 5:00 pmClosed
SE
(OP) Circle, HPSEBL, Una
Tender for prov. 11 KV HT Line to proposed 11 0.4 KV 250 KVA Sub Station for SOP to 190 BHP M C of IPH Deptt. at village Nakroh Ramnagar under ESD HPSEBL, Bharwain
2022_HPSEB_56737_1
OCU-12/2021-22
Open Tender
Electrical Works
Item Rate
60 days
Nakroh
please refer tender document
3 documents required · 3 mandatory
₹590
₹7,930
30 Mar 2022
11 Feb 2022
18 Feb 2022
11 Feb 2022
17 Feb 2022
12 Feb 2022
Amount
A ERECTION PART of 11 KV HT Line
Errection of S.T pole Single Pole 9 Mtr. Long:- Digging of Pit fixing of insulator , X-arm and cutting, drilling of holes in X-Arm , Bracing Set, Top Clamp, errection of pole, fixing of barbed wire and danger plate, filling of Pit and ramming, painting of poles x-arms complete in all respect.
Errection of S.T pole double Pole 9 Mtr. Long (Dead pole str.):- Digging of Pit fixing of insulator, disc and drilling of holes in X-Arm , Bracing Set, Top Clamp, errection of pole, fixing of barbed wire and danger plate, filling of Pit and ramming & painting of poles, x-arms complete in all respect.
Errection of S.T Single Pole 9 Mtr. Structure for tapping pole structure:-Digging tapping str. of pit , errection of pole i/c pit ramming, fixing of suitable X-arm, knee bracing set & pin/G.O switch, D.O fuse wire, disc insulator, painting of pole complete in all respect.
Digging of pits and fixing of earthing pipe of pit for coal earthing, fixing of G.I wire to system filling of pit and remaning work complete in all respect.
Errection of Stay Set HT:- Digging of Pit fixing of Stay Rod, filling of Pit, Nozeiling & Tightning complete in all respect.
Stringing and sagging conductor:- Laying of conductor (7/3.15mm) stringing and sagging, binding with insulator complete in all respect (11 kv line=0..425kmsx3 wires=1.313 kms condt. )
Laying of G.I Wire, Stringing, Sagging and binding complete in all respect.(Double Wire)
Fixing of jumper complete in all respect.
A) Erection Part of 11/0.4 KV, 250 KVA Transformer
Errection of drop out, fuse unit, linghting arrestor, MCCB Switch of LT paneel Box, Energy Meter, Errection of 400 kVA T/F, and earthing conn. to T/F G.O Switch lightning etc., Errection of Jumper, Pipe earthing 3 Nos., Errection of LT cable, brabed wire and painting, 3 Nos. earthing to S/Stn. by prov. 50Kg Salt charcole in each earthing i/c construction of trench for earthing as per REC Board Standard complete in all respect ,
B) SUPPLY PART of 11 KV HT Line Material to be provided by the contractor
Steel Tubular Pole 9 mtr. long
AAAC 7/3.15mm2 (55mm2) (Eq. to Rabbit)
11 KV Pin insulator (Porcelain, 12 KV, 10 KN)
11 KV Disc insulator set on dead end str. including ball cleave & eye socket and dead end clamp complete in all respect.
11KV Danger Plates (250*200*1.6mm)
Aluminium Paint
Stay set complete in all respect
H.T Stay wire 7/3.15 @ 10Kg Per stay set
A-I Knee Bracing Set Single Pole (50*50*6m) length 750 mm * 2 No * 5 Str.
C.I-X-Arms 1500x100x50x6mm for single pole.
C.I-X-Arms 2400x100x50x6mm for double pole and G.O Switch
A.I-X-Bracing Set for double pole (1500x100x50mm+2700x50x50mm) Two Nos. per set.
Earth hook.
Half clamps
Full clamps
Nut & Bolt off various sizes.
Earthing HT complete.
RCC Muff with filling of concrete
G.I. Wire 8 SWG
G.O Switch complete 400 A, 25 kA
Barbed Wire
B1 Supply Part of 11/0.4 KV, 250 KVA Transformer
Prov. 11/0.4kv- 250 kva Transformer.
Prov. LT Dist.Pannel Box MCCB (400 A, 36 KA, 4P, 1 No) &B32SFU (100A, 4 No, rewirable complete in all respect for 250 kva DTR
Prov. L.T.cable 3-1/2 core 185 mm^2.(Incomig)
Prov. L.T.cable 3-1/2 core 240 mm^2. (Outgoing) for 3 no. Out-Going Feeder.
Prov. Thimbles.
Energy meter (3-phase 4 wire ) DLMS Complaint 400 A ct Type for 250 KVA D.TR
Prov. Pipe earthing of S/Stn .
Surge Arrester , 9 kV Station class (Porcelain Type)
C Civil Work
RCC Foundation for Transformer of size 1.50*1.50*1.25 mtr. (1.00 mtrs above ground level 0.25 mtrs below ground leven in cement concrete 1:1.5:3 on the PCC bed of 1.65*1.65*0.075 proving Tor Steel reimprovement 41 Kg & structured Steel 41 Kg complete i/c form work & curing as per direction of Engineer-In-Charge.
Chain link fencing on vertical support of ISA 65*65*6 mm 1.80 mtr height above ground level and 60 Cm embeded in ground in cement concret 1:2:4 and providing and ereciton of MS Steel gate size 1*1.50 mtrs complete including priming coat and paining complete in all respect as per direction of Engineer-In-Charge.
ILLUMINATE MANAGEMENT AND GLOBAL SERVICES PVT LTD
Lath Electrical Works
M/s Madan Lal Govt. Cont.
Duvedi Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .