Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC TENTUNBARIA GARIA KOLKATA 700084 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700084 | L1 | Accepted-AOC WORK ORDER ISSUED | |
| 2 | L2₹3.7 L+₹1,291.91 (0.35%)Rejected-Finance | L2 | Rejected-Finance Not L1 Bidder | |
| 3 | L3₹3.7 L+₹3,072.46 (0.83%)Rejected-Finance 126 BAGMARI ROAD KOLKATA 700054 | KOLKATA | KOLKATA | WEST BENGAL | 700054 | L3 | Rejected-Finance Not L1 Bidder |
Tender Value
Refer Docs
EMD Value
₹7,700
Closing Date
17 Jul 2025, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer, EMSD-I
Office of the Assistant Engineer, EMSD-I, P16 India Exchange Place (Extn.), C.I.T. Annexe Building, KOL-73
Providing voltage correction arrangement with allied works at P.H. No. Ward No.14 of Ashokenagar Kalyangarh Municipality Ground water-based W/S Scheme under EMSD-I, PHE Dte. in 24Pgs(N).
2025_PHED_871695_9
WBPHED/AE/EMSD-I/NIET-10/25-26
Open Tender
Miscellaneous Works
Item Rate
30 days
Office of the Assistant Engineer, EMSD-I
Please refer Tender documents.
5 documents required · 5 mandatory
₹7,700
15 Oct 2025
4 Jul 2025
22 Jul 2025
4 Jul 2025
17 Jul 2025
4 Jul 2025
Amount
Dismantling the existing damaged voltage stabilizer & allied from existing position all complete & kept at site.
Supply & delivery at site of 25 KVA 3-phase oil cooled type Servo Motor operated copper would line voltage Corrector conforming to IS-9815 (Pt.1)-1994 suitable for unbalanced input and unbalanced load voltage with following specification including first filling oil as per IS-335 where applicable [Make- Eltek/Sen & Pandit/Fiji/ECS/Digitek/OPTP/Any other approve make) Input Voltage: 3 Phase Main supply may or may not be balanced with respect to phase to phase 250V- 500V and Phase to neutral 144V-289V. Output Voltage: 3 Phase balanced output phase to phase 415±1% phase to neutral 240 V±1% and as per NIT Specification.
Installation of the above Voltage Stabilizer on the floor making suitable foundation by supplying all required materials and commissioning the same as per direction of E.I.C.
Supply & delivery at site of a) 100 Amp TPN Rewire able type switch fuse. ( Make Havells/ GEC/ Standard/any other approved make)
Supply & delivery at site of 100Amps wall mounted 4-way Bus-Bar chamber having 4nos. Copper bus-bar. ( Make Havells/ L&T/ Standard/any other approved make)
Supply & delivery at site of 100 Amp kit kat rewireable. ( Make Havells/ L&T/ Standard/any other approved make)
Supply & delivery at site of 100 Amp. 4 pole on load change over switch. ( Make Havells/ Standard/any other approved make)
Supply & delivery at site of 35 Sq. mm. 1.1 KV grade 3 1/2 core Al. conductor armoured P.V.C. /XLPE insulated cable. NB: Cable to be supplied as per sire requirement. ( Make: GLOSTER/NICCO/Polycab / Havell’s/Mescab)
Fitting, fixing of main switch & bus-bar as in item no. 4 to 7 on flat iron frame/angle iron frame on wall by supplying all necessary fixing materials including welding all complete as per direction.
Laying of cable as in item no.8 on wall/surface including S&F of MS saddles with earthing attachment in 10 SWG GI(HOT DIP) wire making holes etc. as necessary mending good damages and paint all complete.
Finishing the end of cable by crimping method including supplying of suitable size Al. thimble, tapes, jointing materials & supplying and fixing suitable type compression gland for above cable including supply of brass gland, rubber ring etc.
Earthing with 50mm dia. G.I. pipe 3.64mm thick x 3Mtr.(10ft.) long and 1 x 4SWG G.I. wire(4Mtr. long) 13mm diametre x 80mm (3inch) long G.I. Bolts, double nuts, washer including S & F 15mm diametre G.I. pipe protection(1Mtr. Long) to be filled with bitumen partly below ground level to an average depth of 3.65Mtr.(12ft.) below the ground level and restoring the surface duly rammed.[This cost includes earth pit and its necessary lid making]
Extra for treatment of soil by salt and charcoal coke for pipe electrode.
Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Brick work around the earth pits, neat cement finishing, supply & fitting fixing of MS cover plates above the earth pits all complete as per satisfaction of E.I.C.
Making internal/external electrification of P/House by 2 x 1.5 sq.mm. P.V.C. cu wire through suitable size casing/capping for 4 nos. point ( 1 no. bracketpoint , 1 no. tube light point , 1 nos. bulk head point and 1 fan point ) and 1 no. 5A ,5 pin plug point with earthing attachment of 1 x 1.5 sqmm cu. Wire with supplying of tube light fittings , bulbs & 1200mm sweep celling fan(Make-As per approved vendor list.) as per approved make including suppying and fixing 10 A. DP MCB (As per approved vendor list.) make on wall all complete as per I.E. rules and direction. (including making external illumination by Supply & fixing of 1 no. 40W LED IP 66 type outdoor luminairie incl. Supply & installation of MS bracket & connection complete)
Testing, Commissioning the whole installation upto entire satisfaction of E.I.C.
Add: GST @ 18%
Add: Cess @ 1%
INDTECH ASSOCIATES (BID ID -6715603)
A. G. ENTERPRISE (BID ID -6715617)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .