Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.4 LAccepted-AOC | ₹8.4 L | L1 | Accepted-AOC BEINGL1 |
| 2 | Rejected-Technical C 357 MIDC INDL AREA PAWANE THANE MAHARASHTRA 400705 | THANE | MAHARASHTRA | 400705 | - | - | Rejected-Technical techincally not sutable |
| 3 | Rejected-Technical 301 AKASHGANGA NR GUJARAT COLLAGE ELLISBRIDGE AHMEDABAD GUJARAT 380006 | AHMADABAD | GUJARAT | 380006 | - | - | Rejected-Technical Technically not sutable |
Tender Value
Refer Docs
Closing Date
8 Jan 2021, 10:00 amClosed
H.K. MEENA
Room No. 52, Ground Floor, Administrative Building, Purchase Department, RCF LTD, Chembur Mumbai. 74
SUPPLY OF PIPE FITTING AT RCF TROMBAY UNIT.
2020_RCFL_592821_3
E230200708
Open Tender
Machinery and Machining Tools
Supply
30 days
RCF TROMBAY
Please refer Tender documents.
9 documents required · 9 mandatory
₹0
Exempted
13 Dec 2022
1 Jan 2021
8 Jan 2021
1 Jan 2021
8 Jan 2021
1 Jan 2021
SAP- ELBOW (PTFE LINED) SIZE: 6"" DIA, 90 DEGREE END CONNECTIONS: FLANGED, FLAT FACED. FIXED FLANGE ON ONE SIDE <(>&<)> SWIVEL (LOOSE) FLANGE ON OTHER SIDE ELBOW: ASTM A234 WPB ELBOW DIMENSIONS: AS PER ANSI B16.9 FLANGE MATERIAL: ASTM- A 105 FLANGE DIMENSIONS: AS PER ANSI B 16.5/ASA 150. ELBOW CENTRE: 203 MM LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95 LINING THICKNESS: 3 MM MINIMUM. PTFE/ PFA : ASTM D -1457 TYPE III. TESTS : SPARK TEST @ 15 KV AND HYDROTEST@ 10 KG/CM2 PAINTING : EXTERNAL SUFACES SHALL BE EPOXY PAINTED WITH PRIMER OF 40 MICRON DFT FOLLOWED BY FINISH PAINT(COLOUR-DARK VIOLET) OF 40 MICRON DFT . NOTE : 1) VENDOR SHALL SUBMIT TEST REPORTS/ CERTIFICATES ( HYDROSTATIC, ELECTROSTATIC TEST, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES) ALONG WITH THE SUPPLY.2) PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING.
SAP- PIPE (PTFE LINED) SIZE: 6"" (150 NB) END CONNECTIONS: FLANGED, FLAT FACED. FIXED FLANGE ON ONE SIDE <(>&<)> SWIVEL (LOOSE) FLANGE ON OTHER SIDE PIPE:ASTM A-106 GR B SCH 40 PIPE LENGTH FACE TO FACE = 200 MM FLANGE MATERIAL: ASTM- A 105 FLANGE DIMENSIONS: AS PER ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95 LINING THICKNESS: 3 MM MINIMUM. PTFE/ PFA : ASTM D -1457 TYPE III. TESTS : SPARK TEST @ 15 KV AND HYDROTEST@ 10 KG/CM2 PAINTING : EXTERNAL SUFACES SHALL BE EPOXY PAINTED WITH PRIMER OF 40 MICRON DFT FOLLOWED BY FINISH PAINT(COLOUR-DARK VIOLET) OF 40 MICRON DFT NOTE : 1) VENDOR SHALL SUBMIT TEST REPORTS/ CERTIFICATES ( HYDROSTATIC, ELECTROSTATIC TEST, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES) ALONG WITH THE SUPPLY.2) PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING.
SAP- PIPE (PTFE LINED) SIZE: 6"" (150 NB) END CONNECTIONS: FLANGED, FLAT FACED. FIXED FLANGE ON ONE SIDE <(>&<)> SWIVEL (LOOSE) FLANGE ON OTHER SIDE PIPE:ASTM A-106 GR B SCH 40 PIPE LENGTH FACE TO FACE = 1000 MM FLANGE MATERIAL: ASTM- A 105 FLANGE DIMENSIONS: AS PER ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95 LINING THICKNESS: 3 MM MINIMUM. PTFE/ PFA : ASTM D -1457 TYPE III. TESTS : SPARK TEST @ 15 KV AND HYDROTEST@ 10 KG/CM2 PAINTING : EXTERNAL SUFACES SHALL BE EPOXY PAINTED WITH PRIMER OF 40 MICRON DFT FOLLOWED BY FINISH PAINT(COLOUR-DARK VIOLET) OF 40 MICRON DFT NOTE : 1) VENDOR SHALL SUBMIT TEST REPORTS/ CERTIFICATES ( HYDROSTATIC, ELECTROSTATIC TEST, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES) ALONG WITH THE SUPPLY.2) PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING.
PIPE 6IN DIA PTFE LINED. FLANGE TO FLANGE DISTANCE AFTER LINING 2000 MM PIPE MATERIAL : ASTM A 106 GR.B SCH 40 FLANGE MATERIAL : AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. ONE SIDE FIX & OTHER SIDE LOOSE FLANGE LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95.LINING THICKNESS : 3 MM MINIMUM.FITTING : ASTM A234 WPB. PTFE/ PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST
SAP- PIPE (PTFE LINED) SIZE: 6" (150 NB) END CONNECTIONS: FLANGED, FLAT FACED. FIXED FLANGE ON ONE SIDE <(>&<)> SWIVEL (LOOSE) FLANGE ON OTHER SIDE PIPE:ASTM A-106 GR B SCH 40 PIPE LENGTH FACE TO FACE = 500 MM FLANGE MATERIAL: ASTM- A 105 FLANGE DIMENSIONS: AS PER ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95 LINING THICKNESS: 3 MM MINIMUM. PTFE/ PFA : ASTM D -1457 TYPE III. TESTS : SPARK TEST @ 15 KV AND HYDROTEST@ 10 KG/CM2 PAINTING : EXTERNAL SUFACES SHALL BE EPOXY PAINTED WITH PRIMER OF 40 MICRON DFT FOLLOWED BY FINISH PAINT(COLOUR-DARK VIOLET) OF 40 MICRON DFT . NOTE : 1) VENDOR SHALL SUBMIT TEST REPORTS/ CERTIFICATES ( HYDROSTATIC, ELECTROSTATIC TEST, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES) ALONG WITH THE SUPPLY.2) PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING.
TEE EQUAL 6 X6 X6 IN PFA LINED(PERFLUORO ALKOXY) WITH FLAT FACED FIXED FNGES. FLANGE TO FLANGE DISTANCE FOR 6IN FLANGES AFTER LINING 406 MM . FLNGE MATERIAL : AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95.LINING THICKNESS : 3 MM MINIMUM. FITTING : ASTM A234 WPB. PTFE/ PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST
ELBOW 90 DEGREE 4IN DIA PTFE LINED WITH FLAT FACED FIXED FLANGES. CENTERTO CENTER DISTANCE AFTER LINING 165 MM. FLANGE MATERIAL : AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95.LINING THICKNESS : 3 MM MINIMUM. FITTING : ASTM A234 WPB. PTFE/ PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST
M.S. TEFLON LINED CONCENTRIC REDUCER. SIZE : 6X4 IN FLANGE TO FLANGE DISANCE AFTER LINING 230 MM FLANGE MATERIAL : AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING : PTFE / PFA LINING AS PER ASTM F- 1545-95.LINING THICKNESS : 3 MM MINIMUM. FITTING : ASTM A234 WPB. PTFE/ PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST
SAP-PIPE 4" DIA PTFE LINED. FLANGE TO FLANGE DISTANCE AFTER LINING 200 MM.PIPE MATERIAL: ASTM A 106 GR.B SCH 40.FLANGE MATERIAL: AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. ONE SIDE FIX & OTHER SIDE LOOSE FLANGE. LINING : PFA LINING AS PER ASTM F- 1545-95. LINING THICKNESS : 3 MM MINIMUM.FITTING : ASTM A234 WPB. PFA: ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST & 10 KG/CM2 HYDROTEST
FLANGED TEFLON LINED PIPE,SIZE: 4" NB x 500 LONG, TEFLON LINING THICKNESS: 3 MM MINIMUM, MOC: PIPE: ASTM A-106 GR B SCH 40 , FLANGE : ASTM A-105 B, 150 PSI , ANSI B 16.5 FLAT FACE, TEFLON LINING: ASTM F- 423-75, PRODUCT STANDARD: PS33-70,PAINTING: EXTERNAL SUFACES EPOXY PAINT WITH 40 MICRON PRIMER FOLLOWED BY 40 MICRON FINISH PAINT. PARTY SHALL SUBMIT TEST REPORTS/ CERTIFICATES (MINIMUM HYDROSTATIC ,ELECTROSTATIC TEST, MECHANICAL PROPERTYS OF LINING MATERIAL, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES), ALONG WITH THE SUPPLY. PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING.
FLANGED TEFLON LINED PIPE,SIZE: 4" NB x 1000 LONG, TEFLON LINING THICKNESS: 3 MM MINIMUM, MOC: PIPE: ASTM A-106 GR B SCH 40 , FLANGE : ASTM A-105 B, 150 PSI , ANSI B 16.5 FLAT FACE, TEFLON LINING: ASTM F- 423-75, PRODUCT STANDARD: PS33-70,PAINTING: EXTERNAL SUFACES EPOXY PAINT WITH 40 MICRON PRIMER FOLLOWED BY 40 MICRON FINISH PAINT. PARTY SHALL SUBMIT TEST REPORTS/ CERTIFICATES (MINIMUM HYDROSTATIC,ELECTROSTATIC TEST, MECHANICAL PROPERTYS OF LINING MATERIAL, EXTERNAL PAINT DFT, MATERIAL TEST CERTIFICATES), ALONG WITH THE SUPPLY. PACKING: FLANGE SHALL BE CLOSED AT BOTH THE END SUITABLY BEFORE DISPATCH TO AVOID DAMAGE OF THE LINING.
SAP-TEE EQUAL 4"X4"X4" PFA LINED(PERFLUORO ALKOXY) WITH FLAT FACED FIXED FLANGES. FLANGE TO FLANGE DISTANCE FOR 4" FLANGES AFTER LINING 330 MM . FLANGE MATERIAL : AS PER ASTM A 105, DIMENSIONS TO ANSI B 16.5/ASA 150. LINING : PFA LINING AS PER ASTM F- 1545-95.LINING THICKNESS : 3 MM MINIMUM. FITTING : ASTM A234 WPB. PFA : ASTM D -1457 TYPE III.TESTS : 15 KV SPARK TEST& 10 KG/CM2 HYDROTEST
EASYFLO POLYMER ENGINEERS PVT LTD
SARASONS ENGINEERING INDUSTRIES
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_637670.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .