| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.0 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹29.2 L+₹1.2 L (4.32%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Rejected not being lowest | |
| 3 | L3₹31.5 L+₹3.5 L (12.5%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L3 | Rejected-Finance Rejected not being lowest |
| Sl No | Description | Qty | Unit | M/S ANIL KUMAR L2 | mayur enterprises L3 | Commercial Traders L1 |
|---|---|---|---|---|---|---|
| 1.00 | Supplying, erecting, installing, testing and commissioning including topographical survey of Grid connected Rooftop Solar Photo-voltaic (PV) plant of 30 KWp at 20 Mandir Marg PV output at STC comprising of following sub-components and meeting the specifications as given here-in-after.
Note- Design structural drawings of module mounting structure alongwith design calculations shall be submited by the contractor duly vetted from MNRE approved organisation/ NIT/ IIT / Govt Research Institute/NISE. The cost of the same shall be deemed to be included in this item. Minimal technical requirements/standards for SPV systems/plants to be deployed as per MNRE are mandatorily to be complied within the design.Some of these are narrated here-in-after.For other details website of MNRE may be referred. Bidder must visit the site before quoting the tender. In case any bidder feels that one or more of these system specifications can not be met in his design. | 1 | Each Job | 29,19,999 ₹29,19,999 | 31,50,000 ₹31,50,000 | 27,99,000 ₹27,99,000 Lowest |
| 1.01Photo Voltaic (PV) Modules : The PV modules must conform to the latest edition of any of the following IEC/equivalent BIS Standards for PV module design qualification and type approval:Mono Crystalline Silicon Terrestrial PV Modules:IEC61215/IS14286/ Equivalent IS (if available as on last date of receipt of tender) In addition, the modules must conform to IEC 61701 Salt mist corrosion testing, IEC 62804- Certification for PID resistance, IEC61730Part1-requirements for construction & Part2-requirements for testing, for safety qualification or Equivalent IS. | ||||||
| 1.02Each PV module must use a RF identification tag(RFID),which must contain the following information: (i) Name of the manufacturer of PV Module (ii) Name of the Manufacturer of Solar cells(iii) Month and year of the manufacture(separately for solar cells and module) (iv) Country of origin (separately for solar cells and module)(v) I-V curve for the module(vi) Peak Wattage, Im, Vm and FF for the module(vii) Unique Serial No and Model No of the module(viii)Date and year of obtaining IEC PV module qualification certificate (ix) Name of the test lab issuing IEC certificate (x) Other relevant information on traceability of module as per ISO 9000 series.Note:RFID shall be mandatorily placed inside the module laminate. | ||||||
| 1.03Authorized testing laboratories /centre: PV modules must qualify (enclose test reports/certificate from IEC/NABL accredited laboratory) as per relevant IEC standard.Qualification certificate from IEC/NABL accredited laboratory as per relevant standard for any of the higher wattage regular module should be acompanied with the STC report/certificate. For details of Test Labs refer Ministry of New And Renewable Energy website. The report submitted should not be older than 1 year from the date of issue of Tender. | ||||||
| 1.04PV modules used in solar power plants/ systems must be designed for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. PV modules shall have product warranty of 10 years after completion of work. Contractor shall obtain the warranty certificate from the manufacturer and will submit the same to the AGE SLDC Office. | ||||||
| 1.05Mono Crystalline SPV cells shall be used in the Solar Photo voltaic module. SPV modules should be essentially indigenously manufactured(manufactured in India) irrespective of any other provisions in this tender. The make of SPV shall be Vikram Solar/Indo Solar/Warree/Tata Solar/Adani as approved by MNRE | ||||||
| 1.06Peak power rating of the module shall not be less than 500 Wp. | ||||||
| 1.07The module efficiency shall be more than 16% at standard test condition and the cell should have minimum fill factor of 0.7 with anti reflective coating. It shall be made of high transmittivity glass & front surface shall give high encapsulation gain. | ||||||
| 1.08All materials used shall have a proven history of reliability and stable operation in external applications.It shall perform satisfactorily in relative humidity upto100% with ambient temperatures between -4°C and +60°C and shall withstand wind gust upto 180km/h on the surface of the panel. Each and every SPV module shall be checked for conformity with relevant standard and no negative tolerance shall be accepted. | ||||||
| 1.09The interconnected cells shall be laminated in vacuum to withstand adverse environmental conditions | ||||||
Tender Value
₹31 L
EMD Value
₹62,000
Closing Date
27 May 2026, 6:00 pmClosed
GE Utility Electric Supply
GE Utility Electric Supply Delhi Cantt-10
PROVISION OF 30KW SOLAR CAR ROOF SHEDS AT 20 MANDIR MARG HRCO HUT IN THE AREA OF AGE U SLDC UNDER GE U ELECTRIC SUPPLY DELHI CANTT
2026_MES_763771_1
GE ELECT/TOKEN-01/2026-2027
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE Utility Electric Supply
As Per Tender Documents
7 documents required · 7 mandatory
₹500
GE Utility Electric Supply
₹62,000
6 Aug 2026
6 May 2026
29 May 2026
6 May 2026
27 May 2026
20 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying, erecting, installing, testing and commissioning including topographical survey of Grid connected Rooftop Solar Photo-voltaic (PV) plant of 30 KWp at 20 Mandir Marg PV output at STC comprising of following sub-components and meeting the specifications as given here-in-after.
Note- Design structural drawings of module mounting structure alongwith design calculations shall be submited by the contractor duly vetted from MNRE approved organisation/ NIT/ IIT / Govt Research Institute/NISE. The cost of the same shall be deemed to be included in this item. Minimal technical requirements/standards for SPV systems/plants to be deployed as per MNRE are mandatorily to be complied within the design.Some of these are narrated here-in-after.For other details website of MNRE may be referred. Bidder must visit the site before quoting the tender. In case any bidder feels that one or more of these system specifications can not be met in his design. | 1 | Each Job | - | - |
| 1.01 | Photo Voltaic (PV) Modules : The PV modules must conform to the latest edition of any of the following IEC/equivalent BIS Standards for PV module design qualification and type approval:Mono Crystalline Silicon Terrestrial PV Modules:IEC61215/IS14286/ Equivalent IS (if available as on last date of receipt of tender) In addition, the modules must conform to IEC 61701 Salt mist corrosion testing, IEC 62804- Certification for PID resistance, IEC61730Part1-requirements for construction & Part2-requirements for testing, for safety qualification or Equivalent IS. | - | - | - | - |
| 1.02 | Each PV module must use a RF identification tag(RFID),which must contain the following information: (i) Name of the manufacturer of PV Module (ii) Name of the Manufacturer of Solar cells(iii) Month and year of the manufacture(separately for solar cells and module) (iv) Country of origin (separately for solar cells and module)(v) I-V curve for the module(vi) Peak Wattage, Im, Vm and FF for the module(vii) Unique Serial No and Model No of the module(viii)Date and year of obtaining IEC PV module qualification certificate (ix) Name of the test lab issuing IEC certificate (x) Other relevant information on traceability of module as per ISO 9000 series.Note:RFID shall be mandatorily placed inside the module laminate. | - | - | - | - |
| 1.03 | Authorized testing laboratories /centre: PV modules must qualify (enclose test reports/certificate from IEC/NABL accredited laboratory) as per relevant IEC standard.Qualification certificate from IEC/NABL accredited laboratory as per relevant standard for any of the higher wattage regular module should be acompanied with the STC report/certificate. For details of Test Labs refer Ministry of New And Renewable Energy website. The report submitted should not be older than 1 year from the date of issue of Tender. | - | - | - | - |
| 1.04 | PV modules used in solar power plants/ systems must be designed for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. PV modules shall have product warranty of 10 years after completion of work. Contractor shall obtain the warranty certificate from the manufacturer and will submit the same to the AGE SLDC Office. | - | - | - | - |
| 1.05 | Mono Crystalline SPV cells shall be used in the Solar Photo voltaic module. SPV modules should be essentially indigenously manufactured(manufactured in India) irrespective of any other provisions in this tender. The make of SPV shall be Vikram Solar/Indo Solar/Warree/Tata Solar/Adani as approved by MNRE | - | - | - | - |
| 1.06 | Peak power rating of the module shall not be less than 500 Wp. | - | - | - | - |
| 1.07 | The module efficiency shall be more than 16% at standard test condition and the cell should have minimum fill factor of 0.7 with anti reflective coating. It shall be made of high transmittivity glass & front surface shall give high encapsulation gain. | - | - | - | - |
| 1.08 | All materials used shall have a proven history of reliability and stable operation in external applications.It shall perform satisfactorily in relative humidity upto100% with ambient temperatures between -4°C and +60°C and shall withstand wind gust upto 180km/h on the surface of the panel. Each and every SPV module shall be checked for conformity with relevant standard and no negative tolerance shall be accepted. | - | - | - | - |
| 1.09 | The interconnected cells shall be laminated in vacuum to withstand adverse environmental conditions | - | - | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.42 MB
TD1.pdf
Tender Documents • 1.25 MB
BOQ_855499.xls
BOQ • 0.25 MB
Amend01new_merged.pdf
PDF • 2.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .