Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 CrAccepted-AOC 45 47 INDUSTRIAL ESTATE BHILAI HOUSING BOARD BHILAI DURG CHHATTISGARH 490026 | DURG | CHHATTISGARH | 490026 | ₹9.2 Cr | L1 | Accepted-AOC L1 Bidder after RA. |
| 2 | L2₹9.3 Cr+₹4.0 L (0.43%)Rejected-Finance | ₹9.3 Cr+₹4.0 L (0.43%) | L2 | Rejected-Finance Other than L1 Bidder after Reverse Auction. |
| 3 | Rejected-Technical | - | - | Rejected-Technical The bidder does not meet PQC. |
| 4 | Rejected-Technical A 16 FRONT SIDE MOBILE COMMUNICATIONS INDIA PRIVATE LIMITED NARAINA INDUSTRIAL AREA PHASE II NEW DELHI PHASE II | - | - | Rejected-Technical The bidder has imposed conditions/ counter conditions to the tender terms and specifications in their offer. Against TQCQ, the bidder has not withdrawn the counter conditions. The bid is rejected in line with Clause No. 16.13 of the NIT. |
| 5 | Rejected-Technical | - | - | Rejected-Technical The bidder does not meet PQC. |
Tender Value
Refer Docs
Closing Date
4 Jan 2021, 2:00 pmClosed
SABYASACHI DAS, MANAGER CONTRACTS
Regional Contract Cell, Indian Oil Corporation Ltd. MD, 9th Floor Central Wing, Indian Oil Bhavan, 2 Gariahat Road South, Dhakuria, Kolkata 700068
WBSO ENGG Design, Engineering, Supply, Manufacture, Fabrication, Installation, Testing and Commissioning of Vapour Recovery System Including Comprehensive AMC for 7 years at IOCL, Haldia Terminal, Radhamadhavchak, Haldia, Dist Purba Medinipur, W. B.
2020_ERO_128016_1
RCC/ERO/37/2020-21/PT-137
Open Tender
Mechanical Works
Tender cum Auction
300 days
Haldia Terminal, Radhamadhavchak
As per tender document
11 documents required · 11 mandatory
Exempted
Refer tender document
13 Apr 2021
9 Dec 2020
5 Jan 2021
9 Dec 2020
4 Jan 2021
22 Dec 2020
9 Dec 2020 - 16 Dec 2020
17 Dec 2020
Amount
PART A : CAPITAL WORKS - LSTK for VRU system
Design, Supply, Installation, Testing, Commissioning and Operation of Vapor Recovery Unit at IOCL Depot Manufacture, procurement of materials and bought out components, assembly at shop, painting, testing at manufacturer's works, packing and supply of skid mounted Vapour Recovery System suitable for Class A (Flash point below 23 deg. C) petroleum product including supply of all equipment, power/signal/ control cables (from PMCC, Control Rooms to VRU System), cable trays, instrumentation, commissioning spares, mandatory spares, consumable and special tools & tackles, procurement of materials and bought out components, assembly at shop, painting, testing at manufacturer's works, packing, first fill of lubricants, adsorbents, membranes, drawings and documents as per the enclosed technical specifications & data sheets , other codes and standards as applicable. The scope of supply is inclusive of providing Design, Engineering preparation and submission of all documents & datasheets, drawings, calculation, etc for the proposed VRU system & obtaining approval from IOCL/ PMC Agency. The supply of the VRU system is inclusive of obtaining PESO/ CCOE Approval for the proposed VRU system & its individual components including providing Technical/ Coordination/ Follow up Services, towards preparation and submission of all documents & datasheets, drawings etc including carrying out required no of visits to concerned PESO office. Scope of work involves installation, testing , commissioning and operation of supplied equipment’s. Note: 1) The system to be designed in line with the site requirement/ data sheet/ technical requirement provided along with the tender document. 2) Items to be supplied to site with necessary Test Certificates from OEM of respective equipment & inspection/ dispatch clearance from approved TPI agency as per the QAP for which separate payment shall not be made.
Supply and Installation of vapour recovery arm of size 100 mm NB having 4” (100 NB) with poppeted vapour coupler, break away coupler, NRV, flame arrestor, reducers, mounting structures, parking stand with compatible API adaptor, associated accessories, mounting structure etc complete as per specifications and tender document. Application : MS Note: Any modification required to be done in the existing pipeline ( TLF header ) for installation of supplied loading arm shall be done by IOCL.
PART B : REVENUE WORKS - Operation and Comprehensive AMC Work Operation & maintenance charges (for 7 years - after acceptance of the system) Comprehensive Operations and Maintenance charges including deputation of resident engineer as per the bidders scope of & including all the consumables / spares for 7 years for the VAPOUR RECOVERY UNIT specified in tender specifications. Note: CAMC Charges for each year of operation from from 2nd year to 7th year shall be minimum 3% of the supply and Installation Cost. In case the successful bidder quotes less than 3% of the value in Line item 1 as mentioned above, then for the purpose of payment ‘quoted amount’ (2nd year to 7th year) would be considered as follows: a. CAMC rate for the years which are less than 3% shall be made 3% and equivalent amount shall be deducted from the quoted rate in Line Item 1.010
Charges for Operation During 1st year of Operation (Defect Liability Period )
Charges for CAMC during 2nd year of Operation
Charges for CAMC during 3rd year of Operation
Charges for CAMC during 4th year of Operation
Charges for CAMC during 5th year of Operation
Charges for CAMC during 6th year of Operation
Charges for CAMC during 7th year of Operation
Bidder Name
Amount in Words
M P Engineering Constructions (I) Pvt.
Beekay Engineering Corporation
M P Engineering Constructions (I) Pvt.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.05 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .