Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC 21 JHAMRI 151 JHAMRI JHAMRI ROHTAK HARYANA 124142 UDYAM HR 07 0030314 | JHAJJAR | HARYANA | 124142 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹16.9 L+₹15,433.90 (0.92%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹17.9 L+₹1.1 L (6.57%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | L4₹18.5 L+₹1.7 L (10.3%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 5 | L5₹19.0 L+₹2.2 L (13.2%)Rejected-AOC NEW HOSPITAL ROAD UDHAMPUR UDHAMPUR UDHAMPUR UDHAMPUR JAMMU KASHMIR 182101 | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L5 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
₹21.2 L
EMD Value
₹42,340
Closing Date
30 Mar 2021, 6:00 pmClosed
SHRI A K DUBEY
Military Engineer Services, Commander Works Engineer, Udhampur, PO - Garhi, Udhampur-182121
SPL REPAIR TO THE GROUND AND FIRST FLOOR OF TOILET BLOCKS OF BLDGS NO P-04 AND FIRST FLOOR TOILET BLOCK OF BLDG NO P-05 OF TRANSIT CAMP UNDER GE (NORTH) UDHAMPUR
2021_MES_421172_1
CWE/U(N)-99/2020-21
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (NORTH) UDHAMPUR
₹42,340
Yes
24 Apr 2021
11 Feb 2021
1 Apr 2021
11 Feb 2021
30 Mar 2021
18 Mar 2021
Amount
Taking down chowkats or frames with shutters (without taking off shutters from frames) area exceeding 1.50 square metre and not exceeding 4.0 square metre each, including cutting holes for taking out hold fasts or dismantling brick work (holes cut and any other damage to jambs, walls for taking out hold fast shall be finished identical to existing finish without any extra cost to Govt.), complete all as specified and directed by Engineer-in Charge.
Taking down shutters of any descriptions area exceeding 1 square metre and not exceeding 2 square metre each complete all as specified and as directed by Engr-in-Charge.
Cutting holes into or through brick walls exceeding half brick but not exceeding one brick, built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified.
Pressed steel frames for doors, made out of 1.25 mm thick MS sheet, with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc. complete, of frame size 125 mm x 60 mm, including one shop coat of red oxide zinc chrome primer, including filling voids with PCC 1:3:6 type C-0 complete all as specified and as directed by Engr-in-Charge.
Mild Steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, conforming to Fe-290 Gde-E-165, complete all as specified and as directed by Engr-in-Charge.
35 mm thick, factory made, 2nd class hard wood, plain framed, paneled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engr in Charge.
35mm thick, factory made 2nd class hard wood glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete, all as specified and directed by Engr in Charge.
Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed.
Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick wall nut colour moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, with particle board core, supplying & fixing in frame at site as per specification & drawing as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm wall nut colour PVC sheet reinforced with M.S. Square tube in opening as per specification & drawing, complete all as specified and as directed by Engr-in-Charge.
250 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete, all as specified. (ISI Mark)
150 mm aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed. (ISI Mark)
150 mm aluminium handles, extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed. (ISI Mark)
100mm butt hinges ,medium weight ,cold rolled mild steel all as complete all as specified and directed.
Factory made (box type) mild steel windows/ventilators glazed and gauzed shutters with side hung including pintol hinges, steel peg stay , locking arrangement with glazing & gazing bars dovetailed or welded and one shop coat of red oxide primer complete all specified. Note : i) The ventilators shall be fabricated as per Drg No CEUZ/TD/1302/2009 Sheet 1/3 to 3/3. ii) MS fillets, glazing, wire gauge shall be measured and paid for separately
Mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted or forged into spikes, framed guard bar, barred iron doors; ladder, framed balusters; railing; frame work for water tanks, cooler stand etc and similar work conforming to FE 290-0 or Gde-E-165, complete all as specified and as directed.
Preparation of new steel and iron surfaces exceeding 10cm width or girth and applying two coats of synthetic enamel paint over preprimed surfaces, complete all as specified and as directed by Engr-in-Charge.
3 mm thick figured glass, pin head type, ordinary quality and glazing with oil putty in square or rectangle, area n exc 0.5 sqm in each pane complete all as specified and as directed by Engr-in-Charge.
Broken stone hardcore of gauge exceeding 63 mm but not exceeding 100mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and as directed by Engr-in-Charge
100mm thick Plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in sub base to floors and the like, complete all as specified and as directed by Engr-in-Charge.
Demolition of cement concrete (unreinforced) roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work, complete all as pecified and as directed by Engr-in-Charge.
25 mm thick, Plain cement concrete 1:2:4 type B-0 (using 20 mm graded crushed stone aggregates) as in sub base for laying floor finishes including finishing the surfaces even and rough without using extra cement complete all as specified and as directed by Engr-in-Charge.
Treatment of sunken floor surfaces with 0.488 kg/Sqm first layer of slurry of cement mixed with acrylic based polymer modified cementitious composite compound @0.253 Kg/Sqm. This layer shall be allowed to be cured for 4 hours and then applying in second layer slurry of cement @ 0.242 Kg /Sqm mixed with acrylic based polymer based modified cementitious composite compound @0.126 Kg/Sqm. This layer shall be allowed to be cured for 4 hours, including taking down old/existing treatment with wire brusing and clearing the dust and foreign material before new treatment, complete all as specified and as directed by Engr-in-Charge. Note :- Water proofing treatment will be done by manufacturer of acrylic based polymer modified cementitious composite compound or through their authorised specialized agency which will further have to give a five years warranty for rectification of any defect if incurred at a later stage, otherwise no payment shall be made to the contractor if water proofing treatment is executed by engaging local labour.
Plain cement concrete (1:4:8) type D2 using 40mm graded stone aggregate as in foundation, filling, sub base and mass concrete all as specified.
Cutting holes into or through RCC/Stone/brick walls, superficial area not exceeding 150 Sq. cm, built in cement mortar or cement lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required including 40 mm bore GI spout pipe for suitable length complete all as specified and as directed by Engr-in-Charge .
10mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:3, finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:5:10 type E-2 using 40mm graded crushed stone aggregates as in sunken floor/ foundatiom, complete all as specified and as directed by Engr-in-Charge.
Dismantling PVC particle board partition in any size any description complete all as specified and as directed by Engr-in-Charge.
Demolition of brick work or stone masonry built in cement mortar including all quoins arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan exc 6 m mean radius in half brick thick built in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Brick work with old size sub class 'B' bricks, straight or curved on plan to any radius built in cement mortar 1:6, complete all as specified and as directed by Engr-in-Charge.
RCC M-25 Design mix, (using 20 mm graded crushed stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like all as specified and as directed by Engr-in-Charge.
Use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) etc to obtain rough flat finished surface of concrete complete all as specified and as directed.
TMT mild steel bars, 8mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with and including MS wire (annealed not less than 0.9mm dia) , complete all as specified and as directed by Engr-in-Charge.
15mm thick rendering on fair faces of brick or concrete surfaces in cement mortar 1:6, finish surfaces even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Providing cement concrete 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) in steps, seismic and other similar bands, parapets and railings up to 60 cm in hieght, coping, kneeless apex stones , bed plates, kerbs not provided for including weathering, slightly rounded or chamfered angles including necessary formwork complete all as directed and specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engr-in-Charge.
Glazed coloured ceramic tiles 300x600mm and 8 to 10 mm thick in vertical surfaces like dado/skirting, etc., set and jointed in neat cement slurry and pointed in coloured cement to match, including 10mm thick backing layer of cement mortar in 1:3 to receive tiles in verticle surfaces, complete all as specified and as directed by Engr-in-Charge.
Non skid, coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick screed bed or bedding layer in cement mortar 1:4, complete all as specified and as directed by Engr-in-Charge.
Taking down cement plaster, dado/skirting of any description on brick or stone or cement concrete walls including raking out joints, hacking for key, removing all type of vegetation (like peeple tree etc) scrubbing down with water complete, all as specified and as directed by Engr-in-Charge.
15 mm thick rendering in two layer (10mm + 5mm) on fair faces of brick /concrete on wall including facia chhajja etc.surfaces in cement mortar 1:4 and finished even and smooth without using extra cement including mixing Liquid water proofing compund in the proportion as mentioned in manufacturer's instructions complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compund to be measured and paid for separately as supply only.
5mm thick rendering on brick or concrete surfaces as in ceiling in cement mortar 1:3, and finish the surface even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Preparing plastered or unplastered new surfaces of wall and applying three coats of white wash, complete all as specified and as directed by Engr-in-Charge.
Preparing newly plastered or unplastered surfaces of wall and applying two coats of cement base paint over a coat of alkali resistant primer, complete all as specified and as directed by Engr-in-Charge.
Preparation new surfaces plastered or unplastered and applying three coats of white wash on ceiling all as specified
Preparation old surfaces including complete removal of existing treatment ( white wash) and applying two coats of white wash on ceiling all as specified
Vitreous China wash basin, round bowl type counter top of size 550x445mm coloured fixed in 18 mm thick polished granite 900x600mm size includingPillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe of bore 15 mm, complete all as specified and directed by Engr-in-Charge.
Fancy towel rail 600mm long,brass chromium plated, complete all as specified and as directed by Engr-in-Charge.
PVC connection 15mm size with PTMT nuts of length 450mm complete all as specified.
Taking up or down steel tubing of 15 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 20 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
Taking up or down steel tubing of 40 mm bore with connections for cleaning for refixing or removing to store yard/from site, complete all as specified and as directed by Engr-in-Charge.
15 mm bore steel water tubing medium grade galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
Description all as per srl item No 54 above but except pipes.
20 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
Description all as per srl item No 56 above but except pipes.
40 mm bore steel water tubing medium grade galvanised with and including all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings (such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) complete all as specified and as directed by Engr-in-Charge.
Description all as per srl item No 58 above but except pipes.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 20mm fixing in repair complete all as specified.
Gun metal globe of gate valve with iron wheel head, screwed both ends of size 40mm fixing in repair complete all as specified.
Cutting chases, pinning in making good to facings in brick walls where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth, complete all as specified and as directed by Engr-in-Charge.
100mm PVC multi floor traps with grating including jointing to waste pipe fixed cncrete type B1 (1:2:4). complete all as specified and as directed.(ISI Mark)
Gully Trap 125/110 PVC (SWR ) with grating, setting and jointing with solvent cement in repair, complete all as specified and as directed.
BLANK
Taking down and refixing of 100 mm dia P or S trap, complete all as specified and as directed by Engr-in-Charge.
Dismantling cast iron pipe & reinforced concrete drain pipes, jointed in cement mortar of any dia taking out from trenches or fixed to wall upto 100/75mm complete all as specified.
Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 100mm bore, complete all as specified and as directed by Engr-in-Charge.
Refixing Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints laid in trenches or in floors of 100mm bore complete all as specified and as directed by Engr-in-Charge.
Dismantling and refixing Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall or in floors of 100mm bore,complete all as specified and as directed by Engr-in-Charge.
Dismantling and refixing Cast iron soil, waste and vent pipes (Sand cast pipes) in any length with or without ears, with cement joints fixed to wall or in floors of 75mm bore,complete all as specified and as directed by Engr-in-Charge.
Dismantling and refixing Cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches for 100mm bore pipe,complete all as specified and as directed by Engr-in-Charge.
Dismantling and refixing Cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches for 75mm bore pipe,complete all as specified and as directed by Engr-in-Charge.
Dismantling and refixing Cast iron bends (any radius) with duck's foot or heel rest 100mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
Dismantling and refixing Cast iron bends (any radius) with duck's foot or heel rest 75mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
S&F 100mm Cast iron cowls, complete all as specified and as directed.
Fixing in any size dia dismantling piece/junction plain any radius fixed to CI pipes in reducer complete all as specified and as directed.
Vitreous china water closet, 'Orrisa pattern, including lime concrete bedding, size 580 x 440 mm white with integral foot rests excluding flushing cistern and flush pipe but including connection to trap, anti syphonage pipe etc. complete fixed in repairs, complete all as specified and as directed by Engr-in-Charge. Note: Supply and fixing of flushing cistern, flush pipe, P/S trap including taking down (as the case may be) if required, shall be measured and paid separately under relevant item.
10 ltr capacity PVC valveless, symphonic action type, flushing cistern including suitable PVC flushing pipe, low level, white, with inlet, ball valve, float and handle including brackets with twin flush provision, complete all as specified and as directed by Engr-in-Charge.
Vitreous China wash down water closet pan and seat cover (Semi-pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including P or S trap and including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device, including connection to drain pipe (or out going pipe) and to flushing pipe, antisyphonage pipe, etc. including cast iron 'P' or 'S' trap for 100mm bore of pipe, fixed in repairs complete all as specified and as directed by Engr-in-Charge.
Health faucet, brass, chromium plated, with 1000mm long 8mm dia chrome finish flexible pipe with wall hook, fixed in repair, complete all as specified and directed.
Jet spray, brass, chromium plated, heavy duty, including flexible pipe suitable for 15mm bore water connection, for EWC,fixed in repairs, complete all as specified and as directed.
Superior quality PTMT push button of taps screwed for 15mm bore iron pipe and fixed in repair, complete all as specified and as directed by Engr-in-Charge.
Vitreous china urinal, half stall type white incl CP Spray Nozzale including HDPE waste pipe, providing and fixing plugs bedding urinal against wall in cement mortar 1:2 securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement , flush pipe, grating and union for discharge pipe, incl PVC waste pipe 32mm dia, fixed in repair, complete all as specified.
Description all as per srl item No 84 above but except urinal.
Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms/20mm-125gms).
Soap dish of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 105gms), fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Stop valve (concealed type) of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm- 90gms / 20mm-92gms) fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Swivel shower of PTMT any colour for fixing with 15mm pipe. (Minimum weight 40gms) fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Angle stop valve of PTMT any colour high pressure screwed for iron pipe and fixed, (Minimum weight 15mm-90gms) fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
Rotational moulded polyethylene water storage tank , white colour, ISI marked (cylinderical vertical with closed top) hoisted with Threaded Cap and fixed in position all as specified in SSR Part-I of Capacity 5000 litres each including all accessories (i.e GI nipples and Ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe of bore 25mm (Minimum weight 210 gram) etc), incl dismantling existing water tanks, fixed in repairs, complete all as specified and as directed by Engr-in-Charge.
20mm thick rendering on fair faces of brick or concrete surfaces including repair of damage roof surface in cement mortar 1:4, finished even and smooth with using extra cement, complete all as specified and as directed by Engr-in-Charge. Note : Water proofing compound to be measured and paid for separately as supply only.
Demolition of cement concrete (unreinforced) in ground floor/first floor, sunken floors and in paving not exceeding 15 cm thickness (below or above ground level), complete all as specified and as directed by Engr-in-Charge.
75mm thick plain cement concrete 1:4:8 type D-2 (using 40mm graded crushed stone aggregates) as in mass concrete, filling & sub base to floors, complete all as specified and as directed by Engr-in-Charge
Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors over 20mm thick screed bed in cement mortar 1:4 complete, all as specified and as directed by Engr-in-Charge.
Providing 50 mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight complete all as specified.
Excavating in trenches, n exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth in hard/dense and getting out soil, complete all as specified and as directed by Engr-in-Charge.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, for laying cables/pipes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth in any type of hard rock and getting out , complete all as specified and as directed by Engr-in-Charge.
Demolition & breaking up SGSW drain pipes of 100/150mm bore pipe, complete all as specified and as directed by Engr-in-Charge.
200mm bore salt-glazed stoneware drain pipes of grade 'A' laid in trenches and jointed as specified, complete, complete all as specified and as directed by Engr-in-Charge.
Plain cement concrete 1:3:6 type C-2 (using 40mm graded aggregate) as in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 200mm bore pipes all as specified. Note:-(i) Thickness of bed below barrel of pipe-10 Cms. (ii) width of bed- outer dia of pipe plus 30 cms.
Returning, filling in (soil) including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Pre-cast RCC cement concrete 1:2:4 type B-I (20mm graded) as in manhole cover slab and in similar works bedded and jointed in cement morter 1:4, complete all as specified and as directed by Engr-in-Charge.
Demolition of Reinforced Cement Concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for, complete all as specified and as directed by Engr-in-Charge.
TMT mild steel bars, 6-8mm dia and over, as in reinforcement, cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and including binding with MS wire (annealed not less than 0.9mm dia), complete all as specified and as directed by Engr-in-Charge.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as requiredcomplete all as specified and directed.
Taking down carefully copper /aluminium, point wiring (light, fan, socket or power) complete including fittings and fixtures such as light fittings, switches, ceiling roses, pendants, regulators, sockets etc. and making good disturbed surfaces of wall, ceiling, floors etc, complete all as specified and as directed by Engr-in-Charge.
Point wiring with 1.5 Sqmm PVC insulated, unsheathed (FRLS) cable with multi stranded copper conductor wiring in and including PVC concealed conduit medium grade (ISI marked) 20mm dia and over, wall thickness not less than 2.00 mm thick , and all accessories for one light / bell /exhaust fan controlled by one switch with 1.25mm thick pressed steel terminal anodized box concealed on walls, 3mm laminated plastic sheet cover for mounting of switches, socket outlet, regulator etc or suitable for switches, socket outlet, regulator etc , fixed by suitable size of 4 Nos cadmium screws along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly, complete all as specified and as directed by Engr-in-Charge.
Description all as per item above No 109 but one 3/5 pin 5 Amp socket outlet on independent board .
Description all as per item No 109 above but one 3/5 pin 15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 2.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete all as specified and as directed by Engr-in-Charge.
Switch piano flush button single pole one way 5 Amp, 240 Volts, complete all as specified and as directed by Engr-in-Charge.
Socket outlet, 2 in 1, 3/5 pin, 5/6 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Socket outlet, 2 in 1, 3/5 pin, 15/16 Amp flush type, complete all as specified and as directed by Engr-in-Charge.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Block, complete all as specified and as directed by Engr-in-Charge.
Sheet metal enclosures for distribution board when MCB to be used TPN 4 way 415V with 200 Amps rated bus bar, double door type with IP-43, IK-49 protection with appropraite size bus bar and neutral link fixed flush in wall including cutting chases in walls for fixing DB and making good disturbed wall surfaces to match the existing specifiactions ,fixing in repairs complete all as specified and as directed by Engr-in-Charge.
Taking down carefully old sheet metal enclosure DB,s of any size including MCB's complete all as specified and as directed by Engr-in-Charge.
MCB SP, 6 to 32 Amps,230 Volts including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge. Note : The exact capacity of MCB shall be as directed by Engr-in-Charge.
MCB SPN, 6 to 32 Amps,240 Volts, rupturing capacity 10 KA including providing aluminuium thimbles for outgoing cable, complete all as specified and as directed by Engr-in-Charge.
Slim linear LED lighting fixture 18/20 Watt LED Batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, CRI ≥ 70, PF ≥ 0.9, Surge protection upto 2.0 kV, shatter proof opal sheet of polycarbonate diffuser with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volts, colour temp 6500K, Low heat generating LED, complete making all connections using 1.5 Sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engr-in-Charge. Note : A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE.
S&F in replacement E-Lite LED Curve lighting fixture 10/12 watt LED batten, with full base of extruded polycarbonate body environmental friendly, energy efficient ready to use pack with isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete all as per the directions of Engr-in-Charge. Note : A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE.
Bulk Head Light 9/10 watt LED energy saving with IP65 with opal diffuser, pressure die cast aluminium housing & ring for sturdiness & corrosion resistant, epoxy powder coated, isolated driver, with system efficacy ≥ 100 Lm/watt, operating voltage 170-240 volt, colour temp 6500K, Low heat generating LED complete making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose to fitting complete all as per the directions of Engg-in-Charge. Note : A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE.
Taking down ceiling / exhaust fan, ceiling cable end, dismantling blades and removing fan and blades to store, incl oiling, greasing, cleaning slot, overhauling & replacement of defective nut, bolt , washers etc. and applying two coat painting with synthetic enamel to fans complete, in situ by spraying including filling cavities with filler, one coat after cleaning all dust etc., making all connection using 1.5 sqmm copper conductor multi strand PVC insulated 2 core flexible cable from ceiling rose and rehanging/ refixing complete all as per the directions of Engg-in-Charge.
Sub main wiring with two runs of 4 Sqmm ( 2x4 sqmm ) 1100 volts grade single core FRLS PVC insulated unsheathed multistranded copper conductor confirming to IS-694 drawn through and including non-metalic PVC rigid conduit 25 mm dia ISI marked with all conduit accessories mounting on suface of walls /roofs / ceiling etc with one run of 4 Sqmm (1x4sqmm ) single core FRLS PVC insulated unsheathed copper conductor cable as earth wire, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 4 Sqmm (2x4sqmm ) ,one run of 4 Sqmm (1x4 sqmm ) cable and one metre of conduit will be measured as one unit.
s l sharma and sons
Alishan Builders
M/S JANDIAL ENTERPRISES
MAHAJAN TRADING CO
MADAN LAL SHARMA AND SONS
takashdeep traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .