Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.6 LAccepted-AOC 212 B 8 PARDEWANPUR LAL BANGLA KANPUR 208007 | KANPUR | KANPUR NAGAR | UTTAR PRADESH | 208007 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹33.2 L+₹69,616.50 (2.14%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹33.9 L+₹1.4 L (4.26%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹36.9 L+₹4.4 L (13.5%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹45.5 L+₹13.0 L (39.9%)Rejected-Finance GURU NANAK NAGAR GALI BHATIA DHARAMSHALA WALI SIRSA HARYANA PIN 125055 | SIRSA | HARYANA | 125055 | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
17 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR 208008
REPAIR, MAINT OF UG CABLES INCLUDING ALLIED WORKS IN TECH AREA AT AFS KANPUR
2022_MES_541429_1
8578
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Technical Area under GE (AF) E/M CHAKERI KANPUR
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹80,000
Yes
1 Sept 2022
27 Jul 2022
19 Aug 2022
27 Jul 2022
17 Aug 2022
11 Aug 2022
Amount
Excavation in trenches in soft/loose soil n. exc. 1.5 m wide and n. exc. 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for fixing pole/stay assembly and laying/taking out cables complete all as specified and directed.
Returning, filling trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
Removing of excavated material (soil) to a distance n. exc. 50 m and dispositing where directed at a level n. exc. 1.50 m above the starting point complete as directed.
M&L for sand cushioning to UG cables (8cm deep before laying of cable and 15 cm deep over the cable) complete all as specified and directed. Note:- Punned thickness only will be considered for payment.
Supplying and laying un-reinforced precast concrete cable covers class HV, Type I, flat, size 300mm x 180mm x 40mm ISI marked complete all as specified and directed.
M&L for Bricks for protection cover to under ground cable (with old size sub class ‘B’ bricks) with width equal to length of brick laid dry and flat abutting each other with gaps between adjacent brick not exceeding 10mm complete all as specified and directed.
Supply, laying jointing, testing and commissioning LT XLPE insulated armoured 50 Sqmm, 3.5 core LT 1100 volt grades heavy duty with aluminium stranded conductor cable passing through pipes, induct, on poles, in trenches etc including taking down complete all as specified and directed. Make: Universal Cable / Finolex / Havells / Polycab / Gloster Cables Ltd. / Grandlay Note:- The rate of termination and connecting of cable including provinding suitable size and nos of lugs by crimping as directed and specified shall be deemed to be included in the item rate.
All as per item no. 7.00 above but 35 Sqmm, 3.5 core cable.
All as per item no. 7.00 above but 25 Sqmm, 3.5/4 core cable.
All as per item no. 7.00 above but 16 Sqmm, 4 core cable.
M&L in replacement straight through joint kit Heat shrinkable type suitable for LT XLPE under ground cable of size 10 to 16 sqmm x 2/4 core complete all as specified and directed. Make: Raychem / 3M / Denson
All as per item No 11.00 above but size 25 to 50 Sqmm x 3.5/4 core.
All as per item No 11.00 above but size 70 to 120 Sqmm x 3.5/4 core.
S&F in replacement of MCCB 4pole, 415 Volt grade, AC 63Amp 25KA and Ics =100% of Icu with adjustable thermal release including taking down old unserviceable MCCB complete all as specified and directed. Make:- L&T / Legrand / ABB / Siemens
All as per item No 14.00 above but 100 Amp.
All as per item No 14.00 above but 160 Amp.
S&F in replacement for service cable of PVC insulated unsheathed weather proof twin core aluminium solid conductor 6 Sqmm for street light service cable complete all as specified and directed. Make: Universal Cable / Finolex / Havells / Polycab / Gloster Cables Ltd. / Grandlay
All as per item No 17.00 but cable size 10 Sqmm.
All as per item No 17.00 but cable size 16 Sqmm.
Supply, fixing, installation and testing (in replacement) LT pannel out door (Kiosk type) type, wheather & vermin proof MS sheet housing 3.15mm thick, double door front & rear openable type mounted on 50 X 50 X 6mm to cover all corner and standing legs (min 75cm) of angle iron work, with coloured horizontal Tinned aluminium bus bar 4 pole, mounted on insulators of rating 200 Amps, one MCCB, 4 pole 100 Amps, 25 KA 415 volts at incoming supply. The panel size not less than 600x450x300mm with cable gland, duly powder coated, locking arrengement complete and including grouting in PCC block of suitable size complete all as specified and directed.
Scrapping, cleaning, and preparation of steel tubuler pole (9 m long) steel fitting complete and M&L for painting by one coat of aluminium paint after preparation of the steel surfaces including painting to pole with two coat blue & white paint in strap alternatively all round the poles. Hight of the strap shall be 30cm and Nos of strap shall be 05 Nos complete all as specified and directed.
All as per item No 21.00 above but steel tubuler pole 11 m long.
Supply, laying, testing and commissioning of HT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 11 KV grade with stranded aluminium conductor of size 120 sqmm 3 core laid in trenches/duct / laid on wall etc. including suitable size lugs, thimbles, glands, GI Nuts and bolts, washers, insulation tape etc. and taking our old cable complete all as specified and directed. Make: Universal Cable / Finolex / Havells / Polycab / Gloster Cables Ltd.
All as per item no. 23.00 above but 95 Sqmm, 3 core cable.
Supply, laying jointing, testing and commissioning HT XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured 300 Sqmm, 3 core electric power cables (heavy duty) with aluminium conductor 33000 volts grade including taking down complete all as specified and directed. Make: Universal Cable / Finolex / Havells / Polycab / Gloster Cables Ltd.
Supply & fixing or laying galvanised steel tubing 50mm bore light grade (ISI marked) for protection of under ground cable on poles/ walls (suitable size iron clamps with nuts, bolts & washers) under road crossing etc of following sizes including dismantling and taking down existing pipe complete all as specified and directed. Make: Jindal / Tata / Prakash Surya / Swastik
All as per item No 26.00 above but 80mm bore.
M&L for boring in any type of soil by conventional method under road 1.00 m below the top surface of road complete for passing through 80mm to 100mm dia GI pipe and filling earth after laying of pipe including disposal of surplus soil complete all as specified and directed. NOTE:- Pipe will be measured and paid for separately. Any damage to existing cables of any type will made good by the tenderer without any extra payment.
M&L for removing of cable duct cover for passing of HT cable after taking/passing of HT cable refixing cable duct cover in same position complete all as specified and directed.
Taking down/ getting out carefully old serviceable/ unserviceable HT under ground cable from trench/duct or fixed on walls or laid in duct/ pipe/re-routing, any size and core after repairing, taking out PCC cable cover from trenches, kept in safe custody for reuse of serviceable cable cover and UG cable, complete all as specified and directed. Note:- Earth work and re-laying of cable included in this quoted rate.
S&F HT PCC cable route indicator of size 175mm x 150mm thick, 75 cm long and upper front side each indicator shall be embracing 4mm deep with words "HT CABLE" and two coats of synthetic enamel yellow and red paint along HT cable trench after every 50 m and corner & on any turnning, road crossing etc including planting in ground with PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) complete all as specified and directed.
S&F in replacement pin type, porcelain, vitreous, white or green insulator (HT) 150mm height and 150mm dia, 11000 volts grade including one galvanised MS spindle, two GI washer and one GI nut complete all as specified and directed.
S&F Danger notice plate for HT of size 25X20cm of 1.6mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size including taking down complete all as specified and directed.
S&F HT/LT feeder/equipment name plate of size 30 x 25 cm of 1.6mm thick mild steel sheet, vitreous enameld white, with letters in signal red colour and fixed with MS clamps, bolts and nuts of approved size complete all as specified and directed.
M&L for aluminium conductor steel reinforces (ACSR) straining properly on insulator and binding with aluminium tap / binding with connectors, jumpers etc of any type and sizes complete all as specified and directed.
M&L for detection of fault through fault locating high voltage mobile machine to locate the fault in 11 KV / 33 KV HT cable by giving high voltage surge and to find out exact location of fault complete all as specified and directed. Note: The item includes transportation, fuel charges, charging of machine etc. for full functioning of machine upto detecting fault at a time. Bidder must quote rate considering the fact that he has solely responsible to arrange fault locating machine & he shall not expect any facility from the dept for the same.
M&L for general servicing, repair and maintenance of HT Panel board / RMU/VCB by taking shut down, removing of carbon particles, rubbing of heated portion of bus bar, removing moisture (if any) and cleaning complete by means of CRC-226 / Petrol tightening of all joints in bus bar, checking of earth, replacement of unserviceable nuts, bolts, washers etc including replacement of corroded glands, lugs/ thimbles and tightening them properly including control wiring for metering and relay complete all as specified and directed.
S&F in replacement cable jointing kit termination for HT 11KV grade cable for straight through joint for 50 to 95 Sqmm, 3 core cable complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable and testing after jointing complete all as specified and directed. Make:- Reychem / Denson / 3M
All as per item No 38.00 above but 120 to 185 Sqmm, 3 core cable.
All as per item No 38.00 above but 240 to 400 Sqmm, 3 core cable.
S&F in replacement cable jointing kit termination outdoor type for HT 11KV grade cable for end termination joint for 50 to 95 Sqmm 3 core cable complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable and testing after jointing complete all as specified and directed. Make:- Reychem / Denson / 3M
All as per item No 41.00 above but 120 to 185 Sqmm 3 core
All as per item No 41.00 above but 240 to 400 Sqmm 3 core
S&F in replacement cable jointing kit termination indoor type for HT 11KV grade cable for end termination joint for 50 to 95 Sqmm, 3 core cable complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable and testing after jointing complete all as specified and directed. Make:- Reychem / Denson / 3M
All as per item No 44.00 above but 120 to 185 Sqmm 3 core
All as per item No 44.00 above but 240 to 400 Sqmm 3 core
S&F in replacement cable jointing kit termination for HT 33KV grade cable for straight through joint complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable of size185 to 300 Sqmm, 3 core including testing after jointing complete. Make:- Reychem / Denson / 3M
S&F in replacement cable jointing kit termination outdoor type for HT 33KV grade cable for end termination joint complete with jointing material (Heat shrink type) and accessories suitable for XLPE armoured aluminium conductor cable of size 185 to 300 Sqmm, 3 core and testing after jointing complete all as specified and directed. Make:- Reychem / Denson / 3M
M&L for shifting of serviceable/unserviceable HT equipment. Necessary disconnected from supply and reinstallation of dismantled HT 11 KV switch gears / VCB / Transformers etc. from sub station to a location as directed but not more than 5 Kms complete all as specified and directed. Notes:- The cost of lowering down/mounting the HT equipment from existing /new location shall be deemed to be included under this item.
Cleaning of power house / sub station along with nearby areas with surface dressing 15 cm deep and cleaning away all grass vegetation saplings, brush wood under grouting, roots & tree and not exceeding 30 cm girth and removing rubbish to a distance of 50 m outside the periphery of area complete all as specified and directed.
M&L for earthing complete (in replacement) with galvanized steel plate electrode 60cm X 60cm X 6 mm thick buried directly in ground (Earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized strip 32 X 6mm size by means of bolts, nuts, check nuts and washer of galvanized iron or of steel, earth lead protected by 40mm dia GI pipe light grade watering pipe 20mm dia GI light grade GI wire messed funnel, alternative layer of charcoal and salt, PCC chamber, recessed for and including RCC cover including all necessary excavation and earth work, earth strips connected to HT/LT equipment testing the earthing after completion all as specified and shown in electrical plate No 3 of MES SSR Pt- I 2009 complete all as specified and directed. Note:- GI earth strip and GI protection pipe beyond 7.5 Mtr long measured and paid separately.
M&L for chemical earthing (in replacement) complete with copper plate electrode 900mmx600mm x 5 mm thick buried directly in ground with top edge of plate not less than 4.5m deep below the normal ground level connected to copper strip 50 x 6mm copper strip as main earthing lead and connected and tinted copper bolt, nuts, check nuts ad washers besides brazing at all joints all as directed and connected to earth test point all as specified and directed with and including necessary excavation and earth work, returning filing, removal of extra soil etc, filing adequate quantity of charcoal dust, common salt and MgSO4 upto top of plate, PCC (1:3:6) type C-1 (using 20mm graded crushed stone aggregate) for earth pit chamber with 40mm x 40mm x6 mm mild steel angle iron frame for cover, pre-cast 50 mm thick RCC cover in (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate), reinforcement with 8mm TMT bar @ 75 mm c/c on both way, funnel with wire mesh and 50mm dia galvanised iron pipe light grade for earth lead protection and 40 mm dia galvanised iron medium grade for watering including testing on completion complete all as specified and directed. Note:- (i) The excess requirement (if more than 8.5 Mtr) of copper strip will be measured and paid separately.
S&F in replacement GI earth strip 32 x 6 mm for extension of earth and connected to transformer/equipment or panel with proper clamp, saddle, nuts, bolts and washers etc properly complete all as specified and directed.
M&L for providing locking arrangement to the existitng HT junction box by providing linkages so as to slide the stem of the lock to fit into hole/slot in adjacent leef of the door before welding and painting of approved colour complete all as directed.
M&L for painting lines across the diagonally opposite ends of the front and rear side of the panel, the lines shall be painted in 50 mm wide by red post office shade synthetic enamelled paint including writing "11000 Volts" and DANGER" including formation of Bone and Skull of appropriate size and cleaninig arround the panel complete complete all as specified and directed.
S&F aluminium framing key board of size 600x600x200mm thick with key hook including locking arrengement with three keys 65mm Godrej 7 lever pad lock complete all as specified and directed.
S&F First Aid Box with medicine complete all as specified and directed.
S&F shock treetment chart board with plastic coated and aluminium frame complete all as specified and directed.
S&F in replacement led & tin alloy fuse wire suitable for HT supply complete all as specified and directed.
S&F in replacement of cable lugs suitable for 16 Sqmm to 25 Sqmm cable complete all as specified and directed.
All as per item No 60.00 above but suitable for 35 Sqmm to 70 Sqmm cable.
All as per item No 60.00 above but suitable for 95 Sqmm to 150 Sqmm cable.
All as per item No 60.00 above but suitable for 185 Sqmm to 300 Sqmm cable.
S&F in replacement of EPR high voltage insulation, cable splicing HT tape size 10M length, 38mm width and operating temperature 130deg complete all as specified and directed.
S&F in replacement of SS, GI nuts, bolts & washers of various size as requirement at site complete all as specified and directed.
Attending breakdown attributable to cable faults, flashover in HT panel / VCB or any of the connected transmission line system & rectifying it in 33 KV / 11KV cable / transmission line network upto end connections with panels / transformers or any of electrical item connected therein at Air Force station, Chakeri Technical & Domestic area during any hours of a day during the currency of contract by engaging sufficient manpower after receiving communication through Complaint Section / Concerned JE / Engr-in-charge either through teleponic call, text message, email or through messanger 24x7 hrs complete all as specified and directed. Note: The occurance of fault if any, will be comminicated to the contractor and the contractor shall rectify the same within 4 hrs of reporting, failing to which a recovery @ Rs 1000/- per complaint per day and maximum of Rs 10,000/- shall be recovered from contractor's payment. Contractor shall be bound to arrange his resources accordingly and the quoted rates shall be deemed to include the same. Further, all necessary equipment like HT megger, hand gloves, line testers, earth rod etc shall be readily avilable with the contractor's manpower under his own arrangement. Delay on account of non availability of such items shall not be considered for relaxation.
PAWAN COOL CORPORATION
SAKSHAM SUPPLIERS BUILDERS
M/s Sohanil Construction
BHATIA ENTERPRISES
NEW TECH ELCTRICALS
Ashirwad Contractor and Supplier
M/S S.DAYA SINGH
YS CONSTRUCTION
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .