Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9 LAccepted-AOC | L1 | Accepted-AOC Quoted low | |
| 2 | L2₹10.7 L+₹1.7 L (18.9%)Rejected-AOC 146 CP COLONY 7 NO CHOURAHA KALPANA NAGAR MORAR GWALIOR 474006 | GWALIOR | MADHYA PRADESH | 474006 | L2 | Rejected-AOC Quoted high |
Tender Value
₹10.7 L
EMD Value
₹21,325
Closing Date
23 Jan 2020, 6:00 pmClosed
Ram Mohan S,Asst.Gen.Manager(E-E).
Ram Mohan S Asst.Gen.Manager(E-E), AAI, Mangaluru Intll Airport
Provision of additional CCR Sh SITC of 4 KW and 15 KW CCRs at Mangaluru International Airport
2020_AAI_40139_1
AAI/ML/ENGG (E)/AGM (E)/ NIT-05/2019-20
Open Tender
Electrical Works
Item Rate
90 days
Mangaluru International Airport
As per NIT
10 documents required · 10 mandatory
₹1,120
Airports Authority Of India
₹21,325
20 Feb 2020
14 Jan 2020
29 Jan 2020
14 Jan 2020
23 Jan 2020
14 Jan 2020
14 Jan 2020 - 22 Jan 2020
Amount
Supply & installation of indoor type air cooled thyrisor/IGBT controlled electronic type microprocessor based Constant Current Regulator (CCR) of 15 KW with tapping at 7.5 KW & 10 KW suitable to use an input supply voltage of 230/415 volt 50 Hz AC supply and maximum output current of 6.6 Amps with 5 step current variation for brilliency control, suitable for local and remote control operation with 24/48 volt DC control supply complete with meter to monitor output current, overcurrent, earth fault and open circuit protection, earth leakage meter, positive back indication etc. including interfacing with existing ALCMS and Remote control Desk, testing and commissioning of the CCRs including thorugh existing ALCMS & RCD, documentation etc. complete as required and as per AAI specifications.
Supply & installation of indoor type air cooled thyrisor/IGBT controlled electronic type microprocessor based Constant Current Regulator (CCR) of 4 KW suitable to use an input supply voltage of 230/415 volt 50 Hz AC supply and maximum output current of 6.6 Amps with 5 step current variation for brilliency control, suitable for local and remote control operation with 24/48 volt DC control supply complete with meter to monitor output current, overcurrent, earth fault and open circuit protection, earth leakage meter, positive back indication etc. including interfacing with existing ALCMS and Remote control Desk, testing and commissioning of the CCRs including thorugh existing ALCMS & RCD, documentation etc. complete as required and as per AAI specifications.
Manish Electricals
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .