Loading…
Loading…
Tender Value
₹41.1 L
EMD Value
₹82,200
Closing Date
12 Feb 2026, 4:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
ELECT.G
14 conditions · 3 needing a document upload
As per Railway Board letter no. 2013/CE-I/CT/O/25/VOC dated 05.08.2013, in order to evaluate the financial capacity, capability and past performance of the tenderer, the tenderer shall upload authenticated certificates like Form 26AS or 16A issued by Payment Disbursing Authority or audited balance sheet duly certified by the Chartered accountant or GST return for last three and current financial year must be attached.
The intending tenderers should possess a valid electrical contractor license at the time of opening of tender, issued by any state government & same should be submitted along with tender documents by all bidders including working contractors of this unit otherwise offer shall be summarily rejected....... IT SHOULD BE NOTED BY THE TENDERER THAT ELECTRICAL LICENSE UNDER RENEWAL AT THE TIME OF TENDER OPENING WILL NOT BE CONSIDERED AND OFFER WILL BE SUMMARILY REJECTED. IT IS THE RESPONSIBILITY OF TENDERER TO UPLOAD VALID ELECTRICAL CONTRACTOR LICENSE ON THE DATE OF TENDER OPENING.
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
34 conditions · 5 needing a document upload
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. THE TENDERER SHOULD UPLOAD VALID GST REGISTRATION CERTIFICATE ALONG WITH THE OFFER.
The tender shall comply with General Condition of contract (GCC),2022 of Indian Railways (file attached). and its latest amendment, if any. The tenderer shall submit the offer after duly satisfying himself/herself with the GCC,2022 in general.
Tenderers are required to upload the Bank details as per Annexure-XII (Real Time Gross Saving (RTGS)/National Electronic Fund Transfer (NEFT) Model Mandate Form)of tender document.
Tenderers are required to upload requisite details as per Annexure-VIIB (DETAILS OF CONTRACTUAL PAYMENT RECEIVED IN LAST THREE FINANCIAL YEARS AND CURRENT FINANCIAL YEAR) without which the offer is liable to be rejected.
Tenderers are compulsorily required to upload Affidavit as per Annexure-XXIV along with tender document, without which the offer will be considered incomplete and will be rejected summarily.
All requisite documents/credentials mentioned in clause 3.5 of the tender document attached pertaining to his/their technical and financial eligibility. (As applicable).
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Upload your bank details i.e. Name of the Bank along with Bank Branch Code, Account Number, IFSC Code as per Annexure-J (Real Time Gross Saving (RTGS)/National Electronic Fund Transfer (NEFT)(Model Mandate Form)) of tender document
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenderer/s shall be treated as Null & Void.
Defective parts shall only be replaced with OEM's spares. Proper invoices/delivery challan /warranty certificate etc. shall be provided by the firm to prove genuineness of spare parts.
This tender complies with Public Procurement Policy (Make in India) Order 2017, dated 15/06/2017, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no. 2015/RS(G)/779/5 dated 03/08/2017 and 27/12/2017.
IF ANY DISCREPANCY IS FOUND IN THE TENDER DOCUMENT, NAMELY SOR ITEM DESCRIPTION, SPECIAL TENDER CONDITION ETC., CLARIFICATION CAN BE SOUGHT FROM THE OFFICE OF SRDEE/G/DLI, DRM OFFICE, STATE ENTRY ROAD, NEW DELHI.
This tender complies with Railway Board instructions for Startups (recognized by Department of Industrial Policy and Promotion, Ministry of Commerce and Industry) for exemption from payment of Bid Security as detailed in GCC 2022 as amended from time to time. Such Startup firms may note that no other exemption is applicable to them in this particular tender.
On account payment, contractor shall submitted indemnity bond with validity up to the completion/extended period in the prescribed format (please refer Annexure-XXVIII) at the contractor's cost, vesting the ownership of such material with the railways.
Electrical work regarding Repair/Renovation of training Centre for Personal Branch at Baroda House
53-SRDEE-G-DLI-2025-26~NR
53-SRDEE-G-DLI-2025-26
Open
Works - General
5 Months
Delhi, Delhi
₹0
₹82,200
12 Feb 2026
21 Jan 2026
29 Jan 2026
55 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 41,08,332 | ||
| — | 650.00 | — | — | ||
| "Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core etc. as required. CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.10.3. & as per Explanatory Note. Group C | — | — | — | 9,53,550 | |
| — | 2000.00 | — | — | ||
| Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.14.2 & as per Explanatory Note. Size : 2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire | — | — | — | 5,50,000 | |
| — | 1000.00 | — | — | ||
| Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.14.3 & as per Explanatory Note. Size : 2 x 4 sq. mm + 1 x 4 sq. mm earth wire | — | — | — | 3,34,000 | |
| — | 600.00 | — | — | ||
| Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.14.4 & as per Explanatory Note. Size : 2 x 6 sq. mm + 1 x 6 sq. mm earth wire | — | — | — | 2,63,400 | |
| — | 600.00 | — | — | ||
| Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required of reputed make as per IS, IE rules and site requirement and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.14.5 & as per Explanatory Note. Size : 2 x 10 sq. mm + 1 x 6 sq. mm earth wire | — | — | — | 3,42,000 | |
| — | 30.00 | — | — | ||
| Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including connections, painting etc. as required (For AC's). CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 1.57 & as per Explanatory Note | — | — | — | 21,810 | |
| — | 5.00 | — | — | ||
| Supply, installation, testing and commissioning of GI volume control duct damper complete with neoprene rubber gaskets, nuts, bolts, screws linkages, flanges etc, as per specifications. Conforming to CPWD DSR (E&M) 2022 Item no. 16.13 & as per Explanatory Note | — | — | — | 35,230 | |
| — | 10.00 | — | — | ||
| Supplying & fixing of powder coated extruded aluminium Supply Air Grills with aluminium volume control dampers as per specifications. Conforming to CPWD DSR (E&M) 2022 Item no. 16.15 & as per Explanatory Note | — | — | — | 91,050 | |
| — | 300.00 | — | — | ||
| """GSS DUCTING"" Supply, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports etc. as per approved drawings and specifications of following sheet thickness complete as required of Thickness 0.80 mm sheet. Conforming to CPWD DSR (E&M) 2022 Item no. 16.12.1.2 & as per Explanatory Note | — | — | — | 3,78,900 | |
| — | 40.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with brush less direct current ( BLDC) motor, class of insulation B, 03 Nos blades, 30 CM long down rod, 02 Nos conopies, shakle kit, safety rope, copper winding, Power factor not less than 0.9, service value ( CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350RPM ( tolerence as per IS: 374-2019 or latest) THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C ( max) , insulation resistance more than 2 mega ohm, suitable for 230 V, 50Hz, single phase AC supply, earthing etc. complete as required. CPWD General Specifications for Electrical Works Part-I Internal - 2023, CPWD DSR (E&M) 2022 Item no. 19.1 & as per Explanatory Note | — | — | — | 1,09,200 | |
| — | 50.00 | — | — | ||
| Supply, fixing, testing and commissioning of following modules, GI box alongwith modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement complete and as per latest relevant IS. Size = 3 Module & as per Explanatory Note. | — | — | — | 3,250 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of following modules, GI box alongwith modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement complete and as per latest relevant IS. Size = 6 Module & as per Explanatory Note . | — | — | — | 10,000 | |
| — | 150.00 | — | — | ||
| Supply, fixing, testing and commissioning of following modules, GI box alongwith modular base and cover plate for modular switches/ sockets in recess etc as required as per IS, IE rules and site requirement complete and as per latest relevant IS . Size = 8 Module & as per Explanatory Note | — | — | — | 18,900 | |
| — | 250.00 | — | — | ||
| Supply, fixing, testing & commissioning of following modular switch as per IS, IE rules and site requirement complete, as per explanatory note and conforming to IS 3854:1997 or latest. 6 Amp switch | — | — | — | 13,500 | |
| — | 200.00 | — | — | ||
| Supply, fixing, testing & commissioning of following modular switch as per IS, IE rules and site requirement complete, as per explanatory note and conforming to IS 3854:1997 or latest. 16 Amp switch | — | — | — | 17,800 | |
| — | 200.00 | — | — | ||
| Supply, fixing, testing & commissioning of following modular socket as per IS, IE rules and site requirement complete, as per explanatory note and as per latest relevant IS. 5/15 Amp multi pin socket | — | — | — | 26,200 | |
| — | 500.00 | — | — | ||
| Supply, fixing, testing & commissioning of following modular socket as per IS, IE rules and site requirement complete, as per explanatory note and as per latest relevant IS. 13 Amp universal socket | — | — | — | 49,500 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaire, having system wattage 1x18-20 watt complete. LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. The LED based 4 ft. tube light (lamp) shall be conforming to PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev-'3' & Rev-'4') or latest & as per Explanatory Note | — | — | — | 64,300 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaire, having system wattage 2x18-20 watt complete. LED tube and inbuilt LED driver, CRCA body powder coated, complete with all mounting arrangement, accessories. The LED based 4 ft. tube light (lamp) shall be conforming to PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev-'3' & Rev-'4') or latest & as per Explanatory Note | — | — | — | 1,08,800 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED down lighter, housing aluminum die cast, white powder coated and PMMA diffuser having system wattage less than or equal to 15-18 Watt complete with all mounting arrangement, accessories complete conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev '3') or latest at Tech Spec-II attached & PCEE/NR's spec. No. PCEE/NR/121 Elect/PS/2019 (Rev- '4') at Tech Spec III attached or latest & as per Explanatory Note. | — | — | — | 74,400 | |
| — | 120.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED deep recessed down lighter, housing aluminum die cast, white powder coated and PMMA diffuser having system wattage less than or equal to 15-20 Watt complete with all mounting arrangement, accessories complete conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev '3') or latest at Tech Spec-II attached & PCEE/NR's spec. No. PCEE/NR/121 Elect/PS/2019 (Rev- '4') at Tech Spec III attached or latest & as per Explanatory Note | — | — | — | 1,37,760 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaries 595x595 mm size, recessed mounting fitting (Tile type),as per IS : 10322 having system wattage less than or equal to 45-50 Watt, CRCA body powder coated, high efficiency milky white PMMA diffuser with no bright spot visible complete with all mounting arrangement with suitable frame to avoid droping down of fitting of make Phillips, Bajaj, Havells or similar conforming to CEE/NR's spec. No. CEE/NR/121 Elect/PS/2018 (Rev- '3') or latest at Tech Spec-II attached & PCEE/NR's spec. No. PCEE/NR/121- Elect/PS/2019 (Rev- '4') at Tech Spec-III attached or latest & as per Explanatory Note | — | — | — | 1,61,500 | |
| — | 100.00 | — | — | ||
| Supply, fixing, testing and commissioning of LED light luminaries 300x300x70mm size (1x1), having system wattage less than or equal to 15-20W complete with all mounting arrangement, accessories conforming to CEE/NR's spec. No. CEE/NR/121 Elect/PS/2018 (Rev- '3') or latest at Tech Spec-II attached & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') at Tech Spec-III attached or latest & as per Explanatory Note | — | — | — | 1,23,600 | |
| — | 30.00 | — | — | ||
| Supply, fixing, testing and commissioning of 400mm sweep wall mounted fan complete as per latest relevant IS/IEC standards & as per Explanatory Note | — | — | — | 67,230 | |
| — | 2.00 | — | — | ||
| Supply, fixing, testing and commissioning of POP Up Box for conference hall table including installation kit 2 switch 6A and 2 socket 6A and 1 RJ 11 and 1 RJ 45 socket as per site requirement and IS & IE rule & as per Explanatory Note | — | — | — | 23,000 | |
| — | 200.00 | — | — | ||
| Supply of PVC insulated flexible Copper cable 3C x 2.5 sq mm complete .as per latest IS and IE rules & as per Explanatory Note | — | — | — | 20,000 | |
| — | 3.00 | — | — | ||
| Supply, fixing, testing and commissioning of 150 liter/Hrs L water cooler. Storage type self contained drinking water cooler, operation on 230V AC 50 Hz (Non CFC refrigerant), cooling cap. (in L/hr )-150, storage Cap. (in Lts) 150, Max Energy Consumption -1550 W, Power Factor = or more than 0.85, Tank sheet material-Stainless steel (Grade A-IS304), Thickness of sheet (in mm) 0.8. equal to or more than, Water Tank cover material -Stainless steel (Grade A IS304) thickness 0.8 and lid bottomsheet material and thickness-Alluminium sheet material & thickness-Aluminium sheet 1.5 (in mm ), operating voltage 230 V ac single phase 50 Hz, Confirming to IS -1475 or latest, ISI marked, warranty on site as per IRS terms & conditions or OEM whichever is maximum, warranty on compressor as per IRS terms & Condition or OEM whichever is higher. Make USHA,VOLTAS,SIDWAL,BLUE STAR or similar & as per Explanatory Note | — | — | — | 1,09,452 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .