Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.2 LAccepted-AOC | L1 | Accepted-AOC Award of Contract | |
| 2 | L2₹46.0 L+₹28,266 (0.62%)Rejected-Finance | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹49.7 L+₹4.1 L (8.88%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹50.7 L+₹5.1 L (11.1%)Rejected-Finance | L4 | Rejected-Finance Not Being Lowest |
Tender Value
₹45.8 L
EMD Value
₹92,000
Closing Date
2 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineers (North) Ahmednagar
Military Engineer Services Garrison Engineers (North) Nagar Pathardi Road Ahmednagar Fort Ahmednagar 414 002
REPAIR/ REPLACEMENT AND MAINTENANCE OF SEWAGE INSTALLATIONS AND SWIMMING POOL AT ACC AND S AND STATION UNIT AREA UNDER GE(N) AHMEDNAGAR
2024_MES_671462_1
8893/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Garrison Engineers (North) Ahmednagar
Class D Cat a (ii)
8 documents required · 8 mandatory
₹500
Garrison Engineers (North) Ahmednagar
₹92,000
Yes
6 Dec 2024
4 Sept 2024
4 Oct 2024
4 Sept 2024
2 Oct 2024
18 Sept 2024
Amount
Dismantling and taking down/out the burnt out electriccentrifugal/submersible motor 10 HP Capacity from pump foundation, from well of sewage installation or any position and transprotation to repairing bay / workshop for replacing damaged parts such as bearings, sleeves, bushings etc. and for rewinding the electric motor with existing gauge,of super enamelled copper wire including insulating, varnishing, heating, re-assembling & testing the motor at workshop, shifting to site and refixing to its original/desired position including reconnecting all the electric connections by replacement of bolts, nuts & washers including foundation bolts after testing to make it functional complete all as specified and as directed. NOTE : Spares parts reqd to be replaced such as bearings, sleeves, bushings etc.shall be measured and paid separately
--ditto-- All as per srl item No 1 above but centrifugal/ submercible motor of 20/30 HP Capacity.
--ditto-- All as per srl item No 1 above but centrifugal motor of 50 HP Capacity.
--ditto-- All as per srl item No 1 above but submercible motor of 40 HP capacity
Supply and fixing in replacement ball bearing 6309, complete all as specified and as directed.
--ditto-- All as per item No 5 above but of 6310
--ditto-- All as per item No 5 above but of 6311
--ditto-- All as per item No 5 above but of 6313
Supply & fix in Repair of 40/50HP over load relay Complete including Suitable as per directed by Engr-in Charge.
--ditto-- All as per srl item No 9 above but of 30/20 HP capacity
--ditto-- All as per srl item No 9 above but of 10 HP capacity
Removing blockage from sewage Centrifugal pumpset by opening pump set completely, sluice valve, taper reducer etc including taking out sewage sludge and suspended materials accumulated at bottom of wet well, of any liquid depth/ capacity by way of any means including seperate desluding foreign material, sand, ashes, fibre, silt, grease, night soil, etc and and cleaning the wall surfaces of well complete all as specified and as directed.
Removing blockage from sewage Monoblock Submersible pumpset by opening pump set completely, sluice valve, taper reducer etc including taking out sewage sludge and suspended materials accumulated at bottom of wet well, of any liquid depth/ capacity by way of any means including desluding foreign material, sand, ashes, fibre, silt, grease, night soil, etc and removing the taken out sludge mixed material/liquid out side MD land by any means/source and cleaning the wall surfaces of well complete all as specified and as directed. Note for serial item No 12 &13 : (i) Necssary precautions as well as safety measures shall be taken by the contractor without any extra cost, for working in the foul conditions. (ii) The contractor shall be enterily responsible for the lapse, mishappening to any of the manpower deployed and/or to other equipment/machinary/material at the site of work during the execution.
Supply and fixing in replacement of unserviceable PVC insulated cable 3 Core 16 Sqmm, 1100 Volts grade, heavy duty, multistranded copper conductor for connecting motor to panel board with copper lugs duly encased through and including suitable size PVC pipe fixed to wall / laid in floors, Taking down/up unserviceable items included in Rate Quoted etc complete all as specified and as directed.
--ditto-- All as per item No 14 above but 3 Core 10 Sqmm cable
Supply & fixing in replacement Rubber packing 3mm/ 6mm thick suitable for flanged joints Suitable for 150mm to 300mm Pipes complete all as specified and as directed,Taking down/up unserviceable items included in Rate Quoted.
Supply and fixing in repairs 80 mm dia cast iron sluice valve, Class PN-1.6 , ISI marked with stainless steel spindle, both ends flanged including rubber gasket, nuts bolts and washers complete all as specified and as directed,Taking down/up unserviceable items included in Rate Quoted. Make:- Kirloskar,Upadhaya,BIR
--ditto-- All as per srl item No 18 above but 150 mm dia
M&L in replacement of run lead joints 80mm bore in old pipes/specials complete all as specified and as directed.
--ditto-- All as per item No 20 above but 150 mm bore
--ditto-- All as per item No 20 above but 250 mm bore
--ditto-- All as per item No 20 above but 300 mm bore
M&L in replacement contactor suitable for fully automatic star delta starter for upto 10 HP motor , in existing LT panel boards of various locations including connecting with suitable size of copper cable and lugs complete all as specified and as directed.
--ditto-- All as per item No 23 above but for 20 HP motor
--ditto-- All as per item No 23 above but for 30 HP motor
--ditto-- All as per item No 23 above but for 50 HP motor
S&F in Repair Time delay relay Suitable for Star Delta Starter.
S&F in Repair Single phase preventor Suitable for Star Delta Starter.
S&F in Repair Voltmeter 0-500 Volts of existing size/shape Suitable for Star Delta Starter.
S&F in Repair Ammeter 0-100 Amps of existing size/shape Suitable for Star Delta Starter.
S&F in Repair three phase Voltage Monitoring Relay suitable for Star Delta Starter.
Supply & Fixing in replacement MCB SP 6 to 32 Amp,215 Volts, with rupturing capacity 10 KA ,C Curvecomplete all as specified and as directed,Taking down/up unserviceable items included in Rate Quoted.
Supply & Fixing in replacement MCCB 63 Amp, 3 pole 50 Hz 415 Volts, with rupturing capacity 25 KA complete all as specified and as directed,Taking down/up unserviceable items included in Rate Quoted.
--ditto-- All as per srl item No 34 above but 160 Amp, 4 pole 50 Hz 415 Volts, with rupturing capacity 25 KA complete all as specified and as directed.
----ditto-- All as per srl item No 34 above but 200 Amp 4 pole 50 Hz 415 Volts, with rupturing capacity 35 KA complete all as specified and as directed.
Supply & Fixing in replacement pressure gauge of capacity 0-100 kg as per sample suitable fo 10 to 50 HP pump set complete all as specified and as directed.
Supply and fixing in replacement of monoblock pump of 0.5 HP for removing of leakage water at wet well complete all as specified and directed.
Supply ad fixing in repairs 25 mm dia flexible, green, PVC pipe, heavy duty for delivery of monoblock pump at wet well all as directed.
Supply ad fixing in repairs of heavy duty PVC insulated PVC sheathed aluminium stranded conductor of 2 core 4 Sqmm all as directed.
M&L for gland packing of sluice valves 80 mm bore with proper size asbestos grafite gland packing rope complete all as specified and as directed.
--ditto-- All as per Sr item No 41 above but 150mm dia
--dito-- All as Sr per item No 41 above but 200mm dia
--ditto-- All as per Sr item No 42 above but 250mm dia
Supply and fixing in repair of PVC pipe of size 80mm for placing of sewage collecting well air vent pipe with jallies complete all as specified and directed
Supply and fix in repairs, non return valve, ISI marked confirming to relevent IS of size 150 mm all as directed:-
--ditto-- All as per item No 46 above but 80mm dia
M&L for fixing of MS steel chequered plate of 5 mm thick size all as reqd as per site reqd all as specified and directed by engr-in-charge
Repair/ replacement of Iron coupling including rubber cupling as per site requirment as per directed by Engr-in Charge.
Supply and Fixing of Soft starter 415 V 50 Hz of model EMX4i Suitable for pump cap 40/50HP Competely as per directed by Engr-in-charge.
Repair/replacement of automatic star delta starter for pump cap 30 HP including single phase priventer competely as per directed by Engr-in-charge.
Repair/replacement of automatic star delta starter for pump cap 20/10HP including single phase priventer competely as per directed by Engr-in-charge.
Supply only copper sulphate complete all as specified and as directed.
Supply only alum crystal type complete all as specified and as directed.
Supply and fixing in repairs Bearing for 12.5 HP motor/pump complete all as specified and as directed.
Supply and fixing in replacement Coupling nuts bolts of existing size shape and length for 30 / 12.5 HP motor complete all as specified and as directed.
Supply and fixing in replacement of Star Coupling rubber bushes of existing Size / Shape for 30 / 12.5 HP pump sets complete all as specified and as directed.
Supply & applying of High pressure, high Temperature melting grease for 10 HP to 50 HP pump,high pressure & water resistance grease for motor for 10 HP to 50 HP motor all as specified directed by Engr-in-Charge
M&L for Repair of motor/ pump 12.5 HP, 3 Ph, 415 Volts by disconnecting of pipes, foundation, transporting to workshop, opening of pump, cleaning of parts, segregating unserviceable parts carrying out repairs / machining / Rewinding / grinding / metalling works ,greasing, oiling ,reassembling including checking for smooth functioning ,transporting back to site, fixing on existing foundation, connecting with pipes and motor adjusting for proper alignment ensuring smooth functioning complete all as specified and as directed. pump set installed at KK Range by replacement of complete all as specified and as directed
M&L for Repair of submersible/centrifugal/monoblock pump/ motor up to 7.5 HP, 230/415 volts by transporting to civil work shop, opening, taking out old burnt out winding, preparing for re -winding with PVC insulated copper winding of suitable guage including all materials as required, re-assembling, testing at work shop, transporting back to site and connecting with pipe & electric supply after the pump is lowered and testing the pump for smooth functioning complete all as specified and as directed
M&L for Removal / taking up of submersible pump of any capacity from existing borewell or any location depth up to 150 mtr by disconnect of electric cable and delivery pipes etc and lowering pump along with pipe and cable on completion of repairs including connecting and testing complete all as specified and as directed.
Supply and fix in replacement of Outdoor type Panel, made out of CRCA Sheet, Powder coated, Weather Proof,Front Opening Shutter with proper Locking Arrangement,suitable for Totally Enclosed complete and grouting in cement concrete 1:2:4(20 mm graded stone aggregate) work of suitable size including necessary Electric connection and Testing for smooth functioning of submersible pump,Comprising with the following including Taking down unserviceable Panel,complete all as specified and as directed: (a)Contactor-01 Nos ( suitable for 3 to 7.5 Hp Submersible Pump) (b) MCB/MCCB-01 Nos ( suitable for 3 to 7.5 Hp Submersible Pump) (c) Single Phase Preventor -01 Nos ( suitable for 3 to 7.5 Hp Submersible Pump) (d) Digital Voltmeter-01,Digital Ammeter with CT-01 (e) S&F DOL starter ( suitable for 3 to 7.5 Hp Submersible Pump) (f) Three Phase Voltage Monitoring Relay ( suitable for 3 to 7.5 Hp Submersible Pump) (g) Indicating Lamp RYB
Supply, laying, connecting and testing in replacement flat PVC cable, water proof of size 3 Core, 4 Sq mm, 1100 Volts grade copper conductor, multi stranded for submersible/centrifugal pumps complete all as specified and as directed.
M&L for Repair of Suction Sweeper motor/ pump 5 HP, 3 Ph, 415 Volts by disconnecting of pipes, foundation, transporting to workshop, opening of pump, cleaning of parts, segregating unserviceable parts carrying out repairs / machining / Servicing / grinding / metalling works ,greasing, oiling ,reassembling including checking for smooth functioning ,transporting back to site, fixing on existing foundation, connecting with pipes and motor adjusting for proper alignment ensuring smooth functioning complete all as specified and as directed.
Supply, laying, connecting and testing in replacement flat PVC cable, water proof of size 3 Core, 2.5 Sq mm, 1100 Volts grade copper conductor, multi stranded for submersible/centrifugal pumps complete all as specified and as directed. Make - polycab / finolex / Havells
Supply and fix in repairs nylon brush 3 inches,3 or 4 feet long with fixing nuts, bolts & washers complete all as specified and as directed and matching with existing one.
Supply and fix in repairs nylon rope 20 mm dia best quality complete all as specified and as directed. MAKE: GARWARE or equivalent
Supply & fixing in replacement of 50 mm dia flexible green PVC pipe, heavy duty for delivery of suction sweeper in swimming pool all as directed.
Supply & fixing in replacement of CI foot valves of size 300 mm flanged ends, lift type confirming to IS 4038 all as specified and directed by Engr-in-Charge
--ditto-- All as per Sr item No 69 above but size of 80 mm at KK Range Pump house
M&L for applying two coat of synthetic enamel Painting to Cast iron water mains upto 200 mm dia of OH reservoir of height up to 20 metre, Installation Board, gate, Base of pump & Motors Etc complete all as specified and as directed by Engr -in- Charge.
Supply and fixing in repair of chain link fencing 3.0 mm thik mild steel wires, mesh, size 50mm type of any type of standards, rails, straining bolts, including provission of binding wire etc complete all as specified and directed.
S&F in replacement of post top lantern with spun aluminium conopy & dia cast aluminium spigot with opal PMMA acrylic diffuser pre -wired with all accessories including making necessary conection to make it functional complete all as directed by Engr -in charge.
M&L for cleaning swimmingpool tiling, Balancing tank, fountain using suitable chemicals of existing volume upto 7000 Cum all as per directed by Engr- in charge.
S&F Sheet metal enclosure Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB of 32 to 63 Amp complete all as specified and as directed.
Supply and fix fountain light 18 Watt ,220 V AC IP 68 with 09 Nos LED inground burials light water proof in colours-RGB,size of 173x110x110mm complete all as directed.
Supply and Refilling of Chlorine Gas on empty cylinder complete all as specified and as directed. Note :- Empty cylinder shall be issued by the deptt on nominal isuue voucher.
Dewatering, cleaning of overhead reservoir with high pressure jet to remove all mossess , algea ,dirt ,diposits and other sediments ,scubbing of internal portions with wire brushand removal of dirt with sludge machines /industrieal vaccumc leaners and disposal of the same to a safe distance including sterlizing the complete internal surfaces of the tank by using ISI mark grade I bleaching powder /liquid chlorine, washing with fresh water drying up ,applying one coat of anti fungal cement paint on internal surfaces including marking /writing the words on external wall at visible place "Military Engineer Services ' Tank Capacity Date of cleaning " using synthetic enamel paint in white colour over back background and letters height 50mm and width 40mm complete all as directed by Engineer -in -Charge and as specified for following capacities:-
(a) (i) OH Tank at New KLP 100000 Glns capacity (ii) OH Tank at BTR 100000 Glns capacity (iii) OH Tank at New AC Depot 100000 Glns capacity (iv) OH Tank at Dhobi Ghat 120000 Glns capacity
(b) (i) OH Tank at New KLP 150000 Glns capacity (ii) OH Tank at Annex 150000 Glns capacity
(c) (i) OH Tank at queens Rd MAP Qtr 30000 Glns capacity (ii) OH Tank at New AC Record 30000 Glns capacity
(d) (i) OH Tank at MH DMR 120000 Glns capacity (ii) OH Tank at BTR 120000 Glns capacity (iii) OH Tank at Dhobi Ghat 120000 Glns capacity
(e) (i) OH Tank at Kiran Line 50000 Glns capacity (ii) OH Tank at Casstle Rd 50000 Glns capacity
(f) (i) OH Tank at Tarapore Enclave 100000 Ltrs capacity (ii) OH Tank at JK Road 100000 Ltrs capacity
(g) (i) OH Tank at KK Range Lower camp 10000 Glns capacity (ii) OH Tank at EME Wksp 5000 Glns capacity (ii) OH Tank at KK Range upper camp 10000 Glns capacity
(h) UG Sump at KK Range 10000 Glns capacity
Supply and fixing in repair of GSM Based water level indicator ( 10 level indication) with sensors and 4 pair Cat 5e communicable cable from water level indicator to OH tank, PVC pipe and all accessories as per manufactures instruction and all as specified and directed by Engr-in-charge Make:- M V INSTRUMENT / Mobitech
S&F in replacement sign boards for MES installation of size 1200 X 900 mm made out with angle iron 40x40x6 mm as framing covered both side with 2 mm thick aluminium sheet rivetting on frame covered with retro reflective sheet one side & 100 mm high letters as directed. The sign board to be fixed on 2 No. 40X40X6 mm angle iron including legs of length 180 cm below the sign board, legs embedded in PCC(1:4:8) using 40 mm graded stone aggregate including necessary excavation complete at the installation etc Complete all as specified and directed by Engineer-in-Charge. Note: Matter on sign board supplies by Engineer-in- Charge
Supply and fixing of PVC insulated & sheathed Flexible multi core cable of 0.5 Sqmm 6 or 12 core for connection of digital water level indicator all as specified and directed by Engr-in-Charge.
Material and labour for taking down/up of 150 mm CI/DI pipe from Over head tank up to 30 Mtr and removing the old flanges and taking to lathe machine with proper threading ,replacing new flanges with ISI marked ,shifting to site and refixing to its original /desired position including reconnecting all the flanged pipes along with new bolts,nuts&washers and including necessary Scaffolding to over head tank at required Height etc after testing to make no leakages etc complete all as specied and directed by Engr-in-charge.
M&L for Removal / taking up of submersible pump of any capacity from existing borewell depth up to 150 mtr by disconnect of electric cable and delivery pipes etc and flushing the waste soil from borewell after that fixin the extra heavy grade GI/HDPE pipe of 50mm dia which is required and lowering pump along with pipe and cable on completion of repairs including connecting and testing complete all as specified and as directed by Engr in charge Note:- GI/HDPE pipe will be measured and paid seperately.
Supply and Lay HDPE pipe 6 kg/Sqcm pressure P-63 grade 50mm Bore with fitting heavy duty for fixing with submersible pump including clamps nuts and bolts GI fittings all as required as per site requirement complete.
Supply & fixing iron frame including wheel nut bolts with attached teak wood brush for suction sweeper monoblock pump as per existing all as directed by Engnr -in- charge,
Supply only chlorine crystal granules confirming to IS for use in swimming pool for disinfecting of water treatment complete all as specified and as directed.
Supply and laying in trenches/ drawn through pipe/fixed on walls / poles LT underground cable, 1100 Volts, heavy duty, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured with aluminium conductor of size 50 Sq mm 3.5 core over brick/cable cover sand cushioning after taking down/out as existing at site complete all as specified and as directed.
--ditto--All as per Sr item No 87 above but cable of size 4 Core, 16 Sq mm. Note for Sr item No 87 & 88 : - Excavation, Earthwork & protection pipe etc shall be measured and paid seprately under relevant items of this Sch.
Excavation in trenches n' exc 1.5 m wide and n' exc 1.5 m in depth and n' exc 10 Sq m on plan and getting out in Soft / loose soil all as directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n'exc. 25 cm thick all as directed.
Removing excavated material (soil) to a distance n'exc 50 m and depositing where directed at a level n'exc 1.5 m above the starting point all as directed.
Supply & laying of HDPE pipe ISI marked of dia 40 mm polythylene with smooth internal and profiled external surface for non pressure under ground cable icluding coupler and bends complete all as specified and directed by Engr in Charge
Repair/ replacement new flange at flange joint of 80mm and 150mm dia pipe welded the both end flanged joint to original position including Replace the flange,nut bolts,washers,gland packing and arresting the leakages at flanges.
Repairing of GSM Based water level indicator ( 10 level indication) with replacing New sensors and 4 pair Cat 5e communicable cable from water level indicator to OH tank, PVC pipe and all accessories as per manufactures instruction and all as specified and directed by Engr-in-charge
M&L for cast iron / ductile iron specials such bends of any type, radius and angle, tapers any type, straight, bend, increasing, decreasing or double socket etc, tail pices single branch, "Y" junctions, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc suitable for CI / DI pipes class LA upto 300 mm bore pipes etc complete all as specified and as directed by Engineer-in-Charge
Taking up cast iron / ductile iron/RCC Pipe water mains with spigot and socket ends having Flange/ lead / tyton joints including all fittings and burning out joints, removing Flange/lead for 150 bore of pipes from 10 to 30 mtr Depth complete all as specified and as directed.
Supply and laying ductile iron pipes with spigot and socket ends centrifugally K-7, in any length, laid in trenches for 150 mm bore pipes along with replacing New Flanges tightening with nut bolts with out any leakages up to 10 to 30 mtr Depth complete all as specified and as directed. Make:- Kesoram/Kalinga/Tisco/Electro steel NOTE: Lead Joints,Flange Joints With ISI marked Flanges, Tyton joints required are deemed to be included in the unit rate quoted.
Taking up or down GI steel tubing and connections from trenches / walls / floors/from 10 mtr depth of wet well etc removing from submercible motor by opening nuts, bolts and Flanges cleaning for re-fixing for 80 mm bore pipe complete all as specfied and directed by Engineer-in-Charge
Supply and fix 80 mm GI pipe, Medium grade including necessary fittings such as sockets, elbows, tees, reducers, unions, nipples etc laid in trenches / walls / floors/from 10 mtr Depth of wel well etc,fixing with 10HP submercible motor with nuts and bolts and along with replacing New Flanges tightening with nut bolts with out any leakages up to 10 to 30 mtr Depth ensuring without any leakages for 80 mm bore pipe etc complete all a s specified and as directed by Engineer-in-Charge. Make:- Swastik/suryaprakash/Jindal
Supply and fix 50 x 50 x 6 mm thick angle iron frame including painting with two coats of synthetic enamel paint over one coat of red oxide primer on all exposed surface arrangments.
Supply only soda ash complete all as specified and as directed.
M&L for earthing complete with galvanised steel earth plate electrode 60cmx60cm x 6 mm thick buried directly in ground vertically to depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to and including GI wire 4mm as earth lead up to 7.5 mtr length by means of bolts, nuts check muts and washers etc. of galvanised iron or steel all as shown in electrical plate No. 3 including provn of GI protection pipe light grade of 32mm bore upto 7.5m length and connected earth strip to earthing test point all as shown in electrical plate No. 3 of SSR Part - I 2009 and as specified or indicated and testing on completion including necessary excavation & earthwork in any type of soil, PCC (1:3:6) type C1 chamber, precast slab 50mm thick in cement concrete (1:2:4)type B1 (rein forced with welded steel wire fabric (XPM) of weight not less than 4kg/sqm) with frame, funnel with watering pipe of 20mm bore medium grade, wire mesh and lugs test point etc.
Supply and fix DOL Starter Suitable for upto 10 HP motors Submercible/Centrifugal single phase/three phase competely as per directed by Engr-in-charge.
M&L for Removing sand,algae ,silt etc acumulated at bottom of Swimming pool by using motor pumpset completely, including taking out/down motor,brushes etc and cleaning the wall surfaces of Swimming pool complete all as specified and as directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers notexceeding 25 cm, complete all as specified and directed by Engr-in-charge
Cleaning of bushes/small plants up to root level around and surrounding area E/M installations (i.e. Electrical substations, twopole/four pole strucrure out door substation yards ,Sewage pump houses,Over head Tanks and misc E/M installations etc) complete all as specified and directed by Engr-in-charge.
M&L for Cement concrete in foundations,of Type B2 1:2:4 40mm Stone aggregate in filling and mass concrete for angular iron channels of Fencing complete all as specified and directed by Engr-in-charge.
Taking up cast iron / ductile iron/RCC Pipe water mains with spigot and socket ends having Flange/ lead / tyton joints including all fittings and burning out joints, removing Flange/lead for 300 bore of pipes complete all as specified and as directed.
Fixing of DI/CI/RCC pipes above but using old retrieved pipe from srl item No 164 with new tyton joints/Cement Joints/ Tyton Joints of pipes of dia.300mm with removing of sewage blockages including testing any leakages as required etc complete all as specified and directed by Engineer-in-Charge.
S & F Plastic Bucket 60 to 70 ltrs of Existing size for Chlorine crystal granules mixing at Swimming pool with all accessories including making necessary conection to make it functional complete all as directed by Engr -in c
S&F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples on Over Head Tanks which are height up to 30 Mtr including Clamps, Snails Etc including making necessary conection complete all as directed by Engr -in charge
Remove the Pump from Foundation then Dismantle the pump & Clean the inner body Thoroughly existing Impeller Assy Complete and Replace the Gasket Kit and Existing size impellar Assy complete including shaft and Bearing and fit it back on the foundation and Carry out the level Alignment with the motor with replacement of bolts, nuts & washers including foundation bolts all as Directed by Engr-in-charge for the following Pumps of Size:-
An amount of Rs 77,336.00 shall be deducted from BOQ on account of schedule of credit
Ms. S.K. ASSOCIATES (BID ID -3113994)
M/S CHHTRAPATI CONSTRUCTION (BID ID -3118058)
BHAVIN INFRA (BID ID -3113460)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .