Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.2 LAccepted-AOC PANTHAL KATRA REASI J K 182320 | REASI | JAMMU AND KASHMIR | 182320 | L1 | Accepted-AOC Accepted being L1 bidder | |
| 2 | L2₹17.8 L+₹51,835 (3.00%)Rejected-Finance 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L2 | Rejected-Finance Not being L1 bidder | |
| 3 | L3₹17.8 L+₹56,747 (3.29%)Rejected-Finance | L3 | Rejected-Finance Not being L1 bidder | |
| 4 | L4₹18.0 L+₹76,321 (4.42%)Rejected-Finance | L4 | Rejected-Finance Not being L1 bidder | |
| 5 | L5₹19.7 L+₹2.4 L (13.9%)Rejected-Finance | L5 | Rejected-Finance Not being L1 bidder |
Tender Value
₹37 L
EMD Value
₹74,000
Closing Date
26 Jun 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GARRISON ENGINEER SOUTH UDHAMPUR
Udhampur
DAY TO DAY MAINT OF INTERNAL ELECT AT OFFRS JCOS AND ORS MARRIED ACCN AT 9 PARA SF SANSAR CHAND VIHAR NAUBAT RAM KALIMATA 1 FOD CHIBBER ENCLAVE AND OTM ACCN AT 284 FD REGT 103 TA 153 TA 10 DOGRA 1 FOD ASCON MAND AND GE P OFFICE UNDER GE SOUTH UDH
2024_MES_656449_1
GE/S(U)- /2024-25
Open Tender
Electrical and Maintenance Works
Works
270 days
GE SOUTH UDHAMPUR
As per NIT
9 documents required · 9 mandatory
₹500
GE SOUTH UDHAMPUR
₹74,000
3 Sept 2024
29 May 2024
27 Jun 2024
29 May 2024
26 Jun 2024
12 Jun 2024
Amount
Taking down carefully, copper/ aluminum point wiring (light, fan, socket or power) complete including fitting such as switch, sockets, ceiling rose, pendants socket,fan regulators any type, rectangular board ,light fittings,terminal boxes etc removing materials for taking credit and making good disturbed surfaces of walls floors and ceiling complete all as specified and as directed.
Taking down carefully copper/aluminium sub main wiring of size 2.5/4/6/10 sqmm from surface/concealed at any height and removing the materials from site and making good the disturbed surfaces of walls,floors roofs etc complete all as specified and as directed.
Taking down Old/ Unserviceable MCCB/MCB DBs TPN / Main Switches by disconnection of electric connection including old unsv MCCBs,MCBs, isolators etc and making good to distrubed surface complete all as specified and directed.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in existing conduit of any size/makeas per site requirement, PVC back plate for mounting modular type switches, sockets & regulators etc with front plate modular type including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly complete all as specified and as directed. Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish.
All as per srl item No 4 but for 3 pin 6 Amps socket outlet independent board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed.
All as per srl item No 4 but for 3 pin 6 Amps socket outlet on the same board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed.
All as per srl item No 4 but for One light point controlled by two 2-way switches,with cables 1.5 sq. mm size complete all as specified and as directed.
All as per Srl item No 4 but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
All as per Srl item No 4 but for 3 Pin 16 Amps socket outlet independent with cable 4.0 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
Switch Piano flush type 6 Amps single pole one way (Modular Type) with outer strip complete all as specified and as directed.
Switch Piano flush type 16 Amps single pole one way (Modular Type) with outer strip complete all as specified and as directed.
Socket 3 Pin 6 Amps flush (Modular Type) type complete all as specified and as directed.
Socket combined 2-in-1, 3 Pin 6 & 16 Amps flush type (Modular Type) with outer strip complete all as specified and as directed.
Fan regulator electronic, stepped type hum free suitable control speed of fan from 0 to 100 % and connecting electrically complete all as specified and directed.
Bell Push, 6 amp, 230 Volts, 1 Modular type complete all as specified and as directed.
Call bell ding-dong 230 volts complete all as specified and as directed.
Point wiring for one light/ fan/bell point controlled by one switch using 1.5 Sq mm FRLS copper conductor cables (multistanded) PVC insulated and unseathed in Wiring with Copper conductor cables in PVC casing & caping as per site requirement bakellite hylam sheet of thickness 3.0 mm for mounting all type switches, sockets & regulators etc including supplying and laying PVC insulated unsheathed 1100 volts coppper conductor cable 1.5 Sq mm as earth wire stranded and conected to earth dolly complete all as specified and as directed. Note:- Cutting and making same the wall patchs after laying the wire and conduit using putty, white wash and distamper. The surface should be made smooth using putty and should match exactly with the existing wall finish.
All as per srl item No 17 but for 3 pin 6 Amps socket outlet independent board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth complete all as specified and as directed.
All as per srl item No 17 but for 3 pin 6 Amps socket outlet on the same board including PVC insulated PVC unsheathed 1.5 sq mm earth wire and connected to earth dolly complete all as specified and as directed.
All as per srl item No 17 but for One light point controlled by two 2-way switches,with cables 1.5 sq. Mm size complete all as specified and as directed.
All as per Srl item No 17 but for 3 Pin 16 Amps socket outlet independent board with cable 2.5 Sq mm including copper PVC insulated PVC unsheathed 1.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
All as per Srl item No 17 but for 3 Pin 15 Amps socket outlet independent with cable 4.0 Sq mm including copper PVC insulated PVC unsheathed 2.5 sq mm earth wire standard and connected to earth dolly complete all as specified and as directed.
Piano switch 5 Amps single pole one way 230 V, 50 Hz, AC, complete all as specified and as directed by Engr In charge/GE.
Piano switch 15 Amps single pole one way 230 V, 50 Hz, AC, complete all as specified and as directed by Engr In charge/GE.
Socket outlet 2 in 1, 3 pin, 5A, 230 V, 50 Hz, AC, complete all as specified and as directed by Engr In charge/GE.
Socket outlet 2 in 1, 3 pin, 15A, 230 V, 50 Hz, AC, complete all as specified and as directed by Engr In charge/GE.
Bell push flush type 5 amp 230 V, 50 Hz, AC , complete all as specified and as directed by Engr In charge/GE.
Ceiling rose, surface bakelite 65x 50mm two to three terminals fixed on PVC Round Blockcomplete all as specified and as directed by Engr In charge/GE.
Electronic step type fan regulator 120 watt 230 volts 50Hz two module C/S deluxe type complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 10 Sqmm in existing concealed /on wall conduit /casing capping 25mm dia including PVC insulated copper conductor cable 6 Sq mm as earth lead complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 6 Sqmm in existing concealed /on wall conduit /casing capping 25mm dia including PVC insulated copper conductor cable 4 Sq mm as earth lead complete all as specified and as directed. Including taking down old sub main wire.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 4 Sqmm in existing concealed /on wall conduit/casing capping 25mm dia including PVC insulated copper conductor cable 2.5 Sq mm as earth lead complete all as specified and as directed.
Sub main wiring with two single core PVC insulated with copper conductor cable stranded of size 2.5 Sqmm in existing concealed /on wall conduit/casing capping 25mm dia including PVC insulated copper conductor cable 1.5 Sq mm as earth lead complete all as specified and as directed.
Sheet metal enclosure double door type for MCCB TPN DB upto 100 Amps, 4 way vertical type 415 volts with 400 Amps rated busbar and neutral link including MCCB 100 Amps 16 KA , chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
Sheet metal enclosure double door type for MCB TPN DB upto 4 way vertical type 415 volts with 400 Amps rated busbar and neutral link , chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
Sheet metal enclosure double door type for DB Single pole & neutral 12 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed.
Sheet metal enclosure double door type for DBs Single pole & neutral 8 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
Sheet metal enclosure double door type for DBs Single pole & neutral 4 way 240 volts with 200 Amps rated busbar and neutral link including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and as directed.
S&F in replacement MCCB Three Pole & Neutral capacity of 100 amps 415 volts rupturing capacity 16 KA complete all as specified and as directed.
S&F in replacement MCB Single pole and neutral 240 volt any rating upto 40 amps"C" series, with rupturing capacity 10 KA complete all as specified and as directed.
S&F in replacement MCB single pole 240 volt any rating from 10 to 40 amps "C" series, with rupturing capacity 10 KA ,complete all as specified and as directed.
S&F in replacement MCB single pole and neutral 240 volt any rating from 40 Amps to 63 Amps "C" series, with rupturing capacity 10 KA complete all as specified and as directed.
S&F in replacement MCB TPN 415 volt any rating 40 Amps "C" series, with rupturing capacity 10 KA complete all as specified and directed.
S&F in replacement MCB TPN 415 volt any rating 63 Amps "C" series, with rupturing capacity 10 KA complete all as specified and directed.
S&F in replacement MCB TPN 415 volt any rating 100 Amps "C" series, with rupturing capacity 10 KA ,complete all as specified and directed.
S&F in replacement Sheet metal enclosure single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 240 Volts 20 Amps nicluding taking down of old one complete all as specified and as directed by Engr-in-cahrge/GE.
S&F in replacement Angular Lamp holder, PVC/Polycarbonate type with cord grip cap suitable for light fittings complete all as specified and as directed.
S&F in replacement LED lamp white/ warm white 5/7/9 W Base Cap B 22/E27 with all necessary fixing arrengement complete all as specified and as directed by Engr-in-charge/GE.
S&F in replacement LED lamp 0.5 Watt Safelite white/ warm white Yellow/Green/Red Base Cap B22 for engagement lights with all necessary fixing arrengement complete all as specified and as directed by Engr-in-charge/GE.
Modular plate 1 module including taking down old u/s one complete all as specified and as directed.
Modular plate 2 module including taking down old u/s one complete all as specified and as directed.
Modular plate 3 module including taking down old u/s one complete all as specified and as directed.
Modular plate 4 module including taking down old u/s one complete all as specified and as directed.
Modular plate 6 module including taking down old u/s one complete all as specified and as directed.
Modular plate 8 module including taking down old u/s one complete all as specified and as directed.
1.5 sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade complete all as specified and directed by Engr-in-charge/GE.
2.5 sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade complete all as specified and directed by Engr-in-charge/GE.
4.0 sqmm PVC insulated FRLS unsheathed copper conductor single core multi stranded flexible copper cable 1100V grade complete all as specified and directed by Engr-in-charge/GE.
2.5 sqmm PVC insulated FRLS unsheathed copper conductor round three core flexible copper cable 1100V grade complete all as specified and as directed by Engr-in-charge/GE.
S&F in replacement PVC Casing Caping of Size upto 25 mm and 12 mm including all connected accessories (Nail, Tee, Albow etc) complete all as specified and as directed.
S&F in replacement PVC Conduit of Size 20/25 mm including all accessories (Nail, Clamps, Albow etc) complete all as specified and as directed.
PVC Flexible twisted cable twin core copper conductor cable of size 23/0.0076 complete all as specified and as directed.
S&F in replacement fan Capacitor 2.5/3.15mfd AC, 230 volt complete all as specified and directed by Engr-in-charge/GE.
S&F in replacement LED lights fitting 1x 5W, 230V, white/ warm white AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F in replacement LED lights fitting 1x 10W, 230V,AC white/ warm white decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F in replacement LED lights fitting 1x 20W, 230V,AC white/ warm white decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F in replacement LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in replacement LED building security light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
S&F in replacement LED panel decorative down light fitting/recess mounted square type white/ warm white 2X2 36W with high out put diffuser 220 V AC with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in replacement LED panel decorative surface mounted square type white/ warm white 2X2 36W with high out put diffuser 220 V AC with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in replacement LED wall mounting Decorative wall light fixture CITY 3 made up of Polycarbonate, suitable for 9 W retrofit LED Lamp B22 base with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in replacement LED wall mounting Decorative wall light fixture Apple made up of Polycarbonate, suitable for 9 W retrofit LeD Lamp B22 base with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in replacement LED Decorative, STYLO wall mounting, champagne gold finish fixture with plastic body suitable for 9 W LeD lamp B22 base.with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electode 600mm x 600mm x 6.00mm thick burried directly in ground (earth pit not less than 2.25 meter deep below normal ground level connected to and including galvanised steel earth lead wire 4 mm dia by means of bolts, nuts, chock, nuts and washers of galvanised iron or steel including PCC Pit in 1:2:4 type B-I angle iron frame with RCC cover and handle, excavation and earth work in any type of soil light grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 15mm bore upto main board complete all as shown in electrical plate No 3 of MES Sch 2009 (Part I) connected to DB complete all as specified and as directed by Engr-in-charge/GE.
Street light Bracket complete made of GI pipe of suitable size, medium grade 1.2 m long bent to shape as per site requirement along with MS flat iron clamps with nuts, bolts, washers including grouting the same with wall , all as specified and directed by Engg- in Charge/GE.
Supply and fixing GI tubing light grade 40 mm dia along the wall/ in trenches/ in duct / in culvert /road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holdining of GI pipe alongwith poles complete all as specified and as directed.
Switch - socket combination 5 Amps, 5 pin multipurpose with PVC Box, 4 holes complete all as specified and as directed.
Switch - socket combination 15 Amps, 6 pin multipurpose with PVC Box, 4 Holes complete all as specified and as directed.
Inspection,checking, testing and carrying out uniform load distribution from MCB DB by changing its connection and redistribution in proper Circuit/MCB to prevent overloading in any circuit complete all as specified and as directed.
Repairing of unserviceable light point, Fan point, bell point, socket point 5A/15A, switches, sockets or regulator, light fixtures any type , any type MCBs, DB's & all electrical accessories in day to day/door to door maintenance and making it serviceable in all respect with all replacement of any major part but including small length of wires upto 2.5 sqmm single core (not more than 50 cm), adhesive tape and other connected accessories like screws & washers etc. Work shall also include to check & removal of breakages in service connection /sub main of houses as and when directed. The scope of work shall also include cutting of existing Bakelite sheet to accommodate new wiring accessories like switches, sockets, fan regulators etc
Note : (a) Contractors representative/engineer will report to JE E/M / Engr-in-charge daily at forenoon and afternoon to collect routine/urgent works related to internal electric supply till completion of contract. The contractor will ensure availability of manpower equipped with all sort of petty items such as insulation tape, galvanised screws, nuts, bolts, washers etc required to accomplish the job including every type of requisite T&P items to his trades man. All routine/urgent jobs received on job slip will be repaired & got signature of user's and will be deposited to JE E/M with in 24hrs.
Note (b) One Complaints slip to be treated as One Complaint irrespective of No. of replacement mentioned in the same.
Note (c) Contractor to keep his Electrician ready for Urgent Complaints, During odd hours ( 0600 Hrs to 0900 Hrs and 1700 Hrs to 2200 Hrs ) Other than the Regular complaints during working Hrs ( 0900 Hrs to 1700 Hrs )
Note (d) Procurement of Security gate passes of the Electrician , will be sole responsibility of the Contractor
m/s shanti trading company
VISHWANATH AND SONS
ARNABH ASSOCIATES
M/S BHARAT LIGHT ELECRIC.CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .