Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹2.0 L+₹64,801 (48.2%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹1.6 L
EMD Value
₹3,400
Closing Date
28 Dec 2023, 10:45 amClosed
Ex. Engineer(Elect.)/CNZ
C-Block, Defence Colony, New Delhi
Improvement of Electrical Wiring and installation of split AC 1.5 Ton at AVD Jungpura-B
2023_SDMC_179174_1
EE(Elect.)/CNZ/2023-24/47-03
Open Tender
Electrical Works
Item Rate
30 days
Jungpura -B
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹3,400
27 Feb 2024
24 Dec 2023
28 Dec 2023
24 Dec 2023
28 Dec 2023
24 Dec 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. Group C
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 A socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.8 Module (125mmX125mm)
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.12 Module (200mmX150mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 5/6 &15/16A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Installation of exhaust fan in the existing opening ,including making good the damage, connection, testing ,commissioning etc.as required Up to 450 mm sweep
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required Single pole
Supplying and fixing following rating ,double pole,240 volt,isolator in the existing MCB DB complete with connections,testing and commissioning etc. as required 63 amps
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. mm (clamped with 1mm thick saddle)
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
SITC of single phase monoblock pumpset complete with all accessories workable of 240 Volts 50 Hz AC supply (a) 1 HP (0.75 KW) single phase pumpset head from 12- 30 metre suction and delivery 25X25 mm
Supply of 250 mm (10 inch) sweep 1250 rpm exhaust fan Fresh Air Type complete with shutter blades etc. as required.
Supply of 1200 mm sweep 50 Watt, Energy saver ISI marked Bee 5 Star rating AC ceiling fan Suitable for 230 V, 50 hertz AC Supply without regulator with blades , downrod etc. complete as required.
Supply of LED Tube type luminaire 20 Watt rating complete with polycarbonate housing batten integrated electronic driver prewired with high efficient LEDs with the following:(a) Total system wattage 20 watt +/- 5%(b )Luminous efficacy lumens/watt >=95 (c)Power Factor >;=0.95
Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
Supply, Installation, Testing and Commissioning of inverter split air rotary air compressor (R32/R290/R410A refrigerant) 100% copper condenser, rating 2 ton complete with outer unit as required (5 star rated)
S/I/T/C of copper pipe for split AC
S/I/T/C of Drain Pipe
Supply of extra electric wire as required. The size and material of the wire should be same as of the flexible cable which comes with the air conditioner.
S/I/T/C of stand for split AC
S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V
The Electrician
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .