Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.2 LAccepted-AOC | L1 | Accepted-AOC Being Lowest Bidder | |
| 2 | L2₹39.4 L+₹8.5 L (27.7%)Rejected-Finance FLAT NO 203 SEC 14 PLOT NO 142 SHIVSRUTI PARK APARTMENT E WING 1ST FLOOR MOSHI PRADHIKARAN TAL HAVELI DIST PUNE 412 105 | PUNE | MAHARASHTRA | 412105 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹42.5 L+₹11.6 L (37.5%)Rejected-Finance 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L3 | Rejected-Finance Not lowest bidder |
Tender Value
₹41.5 L
EMD Value
₹83,040
Closing Date
6 Mar 2020, 6:00 pmClosed
GE CENTRAL KIRKEE
GE CENTRAL KIRKEE RANGE HILLS ROAD KIRKEE PUNE-411003
REP REPLACEMENT AND MAINT OF WATER SUPPLY PUMP SETS STARTOR PUMPING MAINS DI GI CI PIPES VALVES PUMP SETS FILTRATION PLANTS PAINTING INT ELEC FITTINGS FAN GEYSERS METERS DBs ETC AT TB II UNDER AGE EM I C IN GE C KIRKEE
2020_MES_321350_1
8339/E8 OF 2019-2020
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
DIGHI
As per NIT
7 documents required · 7 mandatory
₹500
Yes
GE CENTRAL KIRKEE
₹83,040
Yes
10 Jun 2020
3 Feb 2020
7 Mar 2020
3 Feb 2020
6 Mar 2020
18 Feb 2020
3 Feb 2020 - 17 Feb 2020
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipes etc and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for lying of pipes etc and getting out in road cuttings/Hard dense soil complete all as specified and directed.
Removing surplus soil to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
Returning filling in trenches including spreading, levelling, watering and well ramming in layers n . Exc 25 cm complete all as specified and directed.
Repairs, Renewal of pipe lines and Attending emergency water supply breakdown complaints within 6 hours on telephonic intimation/SMS by arranging JCB/Excavator for excavation, braking footpath paved with PCC blocks, PCC flooring, bituminous road etc up to 4 met depth, dewatering with suitable dewatering pump, cutting and removing defective pipes, lowering the required size of pipes, valves and fittings with the help of crane and welding works if any, refilling the trench after repair with excavated soil, relaying of removed PCC blocks and matching with surroundings etc complete as directed at site. Note.1) Materials required for the repairs such as pipes, fittings, valves, Mechanical joints etc will be measured and paid under respective items. 2) Items such as Rubber gaskets, Nuts, bolts and washers etc are to be included in the quoted rate.3) the contractor shall provide sufficient barricades, caution tape, dander boards etc at work site to avoid any traffic accidents at site. 4) If the contractor fails to start the work within 6 hours on receipt of telephonic intimation /SMS, Necessary recovery will be made twice the quoted rates of respective items.
M & L for taking up cast iron water mains (incl all fitting) 80mm bore dia of pipe with spigot and socket ends from trenches complete all as specified and directed.
All as item no.6 above but size of pipe 100 mm bore
All as item no.6 above but size of pipe 150 mm bore
All as item no.6 above but size of pipe 200 mm bore
All as item no.6 above but size of pipe 250 mm bore
All as item no.6 above but size of pipe 300 mm bore
M & L for Cutting cast iron pipes in position for insertion of fittings, mechanical joints, replacement of pipes etc for bore of pipe 80mm
All as item no.12 above but 100 bore pipes
All as item no.12 above but 150 bore pipes
All as item no.12 above but 200 bore pipes
All as item no.12 above but 250 bore pipes
All as item no.12 above but 300 bore pipes
M & L for Laying only 80 mm bore CI pipes with spigot and socket ends laid in trenches including thorough cleaning of old CI pipe by descaling internally with steel brushes equal to bore of pipe, scraping washing properly complete all as specified and directed. (to be measured only found serviceable in all respect retrived from item No 6).
All as item no.18 but bore of pipe 100 mm.( serviceable pipe received against item no.7)
All as item no.18 but bore of pipe 150 mm.( serviceable pipe received against item no.8)
All as item no.18 but bore of pipe 200 mm.( serviceable pipe received against item no.9)
All as item no.18 but bore of pipe 250 mm.( serviceable pipe received against item no.10)
All as item no.18 but bore of pipe 300 mm.( serviceable pipe received against item no.11)
M & L for Ductile iron fittings such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc.), Tee piece, single branch 'Y' junction double branch, collar etc., caps and plugs etc. as per IS: 9523-2000 of class K-7, with internal cement mortor lining, and external zinc and black bitumen coated of dia upto 150 mm complete all as specified and directed
M & L for Ductile iron fittings such as bends (any type, radius and angle), tapers any type (straight, bend, increasing, decreasing or double socket etc.), Tee piece, single branch 'Y' junction double branch, collar etc., caps and plugs etc. as per IS: 9523-2000 of class K-7, with internal cement mortor lining, and external zinc and black bitumen coated of dia upto 200 to 300mm complete all as specified and directed
Supply, laying, jointing & testing DI-K7 class with spigot and socket, suitable for Push on rubber joint, with internal cement mortor lining, and external zinc and black bitumen coated pipes in any lengths conforming to IS:8329-2000 including Rubber Gasket & joints as per IS:9523-2000 laid in trenches/ Road/ Ducts/ Footpath/ on wall/ on floor locations for 80 mm bore dia pipe complete all as specified and directed. Make: Electro steel/Electro cast.
All as item no.26 above but 100 mm bore pipes.
All as item no.26 above but 150 mm bore pipes.
All as item no.26 above but 200 mm bore pipes.
All as item no.26 above but 250 mm bore pipes.
All as item no.26 above but 300 mm bore pipes.
Supply, Laying, jointing and testing MS Pipe 450 mm to 500 mm bore, 7mm thick externally coated with anti corrosive paint with welded joints laid in trenches in short lengths as required at site up to 4 met in depth including taking out defective pipes all as directed at site.
M&L for taking up worn out GI steel tubing incl all fittings from trenches of 15 mm bore complete all as specified and directed.
All as item no.33 above but 20 mm bore pipes.
All as item no.33 above but 25 mm bore pipes.
All as item no.33 above but 40 mm to 50 mm bore pipes.
All as item no.33 above but 80 mm bore pipes.
All as item no.33 above but 100 mm bore pipes.
All as item no.33 above but 150 mm bore pipes.
S & F and Laying in trenches/fixed to wall galvanised steel water tubing 15 mm bore, medium grade with and including all medium grade fittings complete all as specified. Make:Tata/Jindal.
All as item no.40 above but 20 mm bore pipes.
All as item no.40 above but 25 mm bore pipes.
All as item no.40 above but 40 mm bore pipes.
All as item no.40 above but 50 mm bore pipes.
All as item no.40 above but 80 mm bore pipes.
All as item no.40 above but 100 mm bore pipes.
All as item no.40 above but 150 mm bore pipes.
M&L for taking apart and reassembling stuffing box of sluice valve S.S. Spindle in position suitable for existing sluice valve including replacement of gland packing. Note: (i) Nuts, bolts & washers wherever required new shall be measured and paid separately under respective Item.
S&F in repairs CI body non raising SS spindle sluice valve with cast iron wheel, of size 80 mm bore, class PN-1.6 with SS spindle with brass nut, both ends flanged confirming to IS-14846 with standard bolts hole, fixing with nuts, bolts, washers, rubber gasket etc complete in position of pipe line all as specified and directed. Note for item no.49 to 55: (i) Nuts, bolts & washers wherever required new shall be measured and paid separately under respective item. (ii) Rubber gasket shall be inclusive of the quoted rate.
All as item no.49 above but 100 mm bore
All as item no.49 above but 150 mm bore
All as item no.49 above but 200 mm bore
All as item no.49 above but 250 mm bore
All as item no.49 above but 300 mm bore
All as item no.49 above but 450 mm bore
S&F in repairs cast iron air release valves with air outlet,100 mm dia flanged including fittings as required at site, making necessary modification/ arrangements and on CI/MS/DI pipeline of bore up to 450 mm
M &L for dismantling & taking out carefully sluice valve head with gate, spindle and stuffing box of size 80 mm to 450 mm bore in position, replacement of worn out SS/GM spindle & GM nut with new SS/GM spindle or GM nut for sluice valve class PN 1.6/ 1.0, and refixing gate, spindle, nut, valve head with stuffing box incl necessary PTFE gland packing, nuts, bolts, washers, gland bolts, rubbers gaskets etc complete all as specified and as directed. Note: (i) SS/GM spindle, GM/SS nuts shall be measured and paid separately under respective items. (ii) Nuts, bolts & washers wherever required new shall be measured and paid separately under respective item. (iii) PTFE gland packing and Rubber gasket shall be inclusive of the quoted rate of this item.
Supply and fix GM/SS spindle for sluice valve class PN 1.6/ 1.0, 80 mm to 150 mm bore
Supply and fix GM/SS spindle for sluice valve class PN 1.6/ 1.0, 200 mm to 300 mm bore
Supply and fix GM/SS spindle for sluice valve class PN 1.6/ 1.0, 450 mm bore
Supply and fix GM/SS nut suitably threaded internally as per spindle thread and to the size of wedge of valve gate for sluice valve 80 mm to 150 mm bore class PN 1.6/ 1.0 complete all as directed.
All as item no.61 above but 200 mm to 300 mm sluice valve
All as item no.61 above but 450 mm sluice valve
S&F in repair gun metal gate valve with iron wheel head, screwed both ends for iron pipes 15mm bore complete all as specified and directed. Make Zoloto/Equivalent.
All as item no.64 above but 20 mm bore
All as item no.64 above but 25 mm bore
All as item no.64 above but 40 mm bore
All as item no.64 above but 50 mm bore
Supply & fixing in repairs cast Iron swing check non return valve confirming to IS : 5312 (Part I) of 1969, both end flanged with rubber gasket & Nuts, bolts & washers of sizes 150 mm bore. (Note:- Nuts, bolts & washers wherever required new shall be measured in appropriate item as supply only)
All as item no.69 above but 80 mm bore.
Supply & fixing in repairs cast Iron foot valve confirming to IS : 4038 flanged end with rubber gasket, Nuts, bolts & washers of sizes 150 mm bore. (Note:- Nuts, bolts & washers wherever required new shall be measured in appropriate item as supply only )
All as item no.71 above but 100 mm bore
All as item no.71 above but 80 mm bore
Supply and fix Mild steel screw bolts (machine made) with hexagonal heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal nut, n exc 10 cm long , 10 to 20 mm dia of neck.
S&F MS mechanical joint with rubber washer, mild steel screw bolts (machine made) with screwed both ends of dia as per flange hole and required length each screwed end to be fitted with washers and one hexagonal nut suitable for bore of pipe 80mm complete all as specified.
All as item no.75 above but 100 mm size.
All as item no.75 above but 150 mm size.
All as item no.75 above but 200 mm size.
All as item no.75 above but 250 mm size.
All as item no.75 above but 300 mm size.
M&L for M & L for PCC (1:5:8) type C5 block masonry over 10 cm in width built in cement mortar (1:6) complete all as specified incl Demolition of unsv precast concrete block walling built in cement morter all as specified and directed.
M&L for cement plaster 10mm thick in CM1:4 on fair faces of brick work or concrete surfaces finished even and fair incl taking down plaster any description, racking out joints, hacking for key, scrubbing down with water complete all as specified.
M&L for PCC 1:3:6 type-C2 (using 40mm graded stone aggregate) as in foundation, filling and mass concrete incl necessary form work wherever required and incl demolition of Cement Concrete (un-reinforced) of any description and in any position not otherwise specifically provided for, all as specified and directed at site.
M&L for mild steel framed work with ends of bars shouldered, welded or riveted or forced into spikes, framed guard bars, ladders, framed balusters, walk ways, railings, gates, frame work of water tank, valve pit and similar work confirming to Fe.290.Gde-E-165 incl painting with one coat of red oxide primer and one coats of anticorrosive black bituminous paint incl dismantling mild steel work of any description not otherwise specially provided for all as specified and directed.
M&L for one coat of synthetic enamel paint to old steel surfaces of any description, incl preparation of surfaces, for area over 10cm in width or girth, not otherwise described as per specified colour code all as specified and directed.
M&L for preparation of plastered or unflustered surfaces of wall and applying one coat of cement based paint of approved tint complete all as specified and directed.
M&L for preparation of plastered or unflustered surfaces of wall and applying two coats of cement based paint of approved tint complete all as specified and directed.
M&L Cement concrete type B-2,1:2;4 ( 40 mm graded stone aggregate ) in sub base 75 mm thick
S&F 80 mm thick machine pressed precast concrete rubber moulded coloured interlocking paver block with coloured cement and pigment any shape and size confirming to IS-15658-2006 M-40 grade laid over 50 mm thick sand cushionining all as directed.
Supply and fix Hot Dipped Galvanized Chain Link Fencing with Zinc Coating, nominal height-2400mm, Pitch-50mm and wire dia 3.15 mm. (approx weight-2.55 Kg /Sqm)
M&L for mild steel work of angle fixed independently for fencing post and others confirming to Gde Fe 410-A incl cutting to dead end length where required, notching, drilling, fitting and/or welding or connecting with bolts and nuts incl dismantling taking down unsv one complete all as specified and directed.
M&L for TMT bars 10mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns hooking ends or as in horizontal bar for fixing in fencing and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete for support of chain link fencing incl dismentling taking down unsv one all as specified and directed.
Supply, install, connecting, testing of display unit of water meter 450mm dia, 300 cum /Hr flow including taking down unserviceable one
Dismantling taking out complete pump of any type, capacity 90 HP to 100 HP from foundation including dismantling suction and delivery pipe connection from pump , carrying to wksp & back and repair/overhauling complete and reassemble and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection complete including testing, commissioning all as specified and directed. ( Note-1.spares required for the repairs will be measured and paid under respective items . 2. Small items such as gaskets, Nuts, bolts and washers, screws, consumable like grease etc will be inclusive of quoted rates.)
Ball Bearing, (DE) suitable for pump set 90HP to 100HP.
Ball Bearing (NDE) suitable for pump set 90HP to 100HP.
Impeller suitable for pump set 90HP to 100HP.
Pump Shaft suitable for pump set 90HP to 100HP.
Lantern Ring suitable for pump set 90HP to 100HP.
Mechanical Seal suitable for pump set 90HP to 100HP.
Water Deflector suitable for pump set 90HP to 100HP.
Sleeve suitable for pump set 90HP to 100HP.
Key Impeller suitable for pump set 90HP to 100HP.
Gland Packing suitable for pump set 90HP to 100HP.
Dismantling taking out complete pump of any type, capacity 15 HP to 30 HP of different models from foundation including dismantling suction and delivery pipe connection from pump , carrying to wksp & back and repair/overhauling complete and reassemble and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection complete including testing, commissioning all as specified and directed.( Note-1.spares required for the repairs will be measured and paid under respective items . 2. Small items such as gaskets, Nuts, bolts and washers, screws, consumable like grease etc will be inclusive of quoted rates.)
Ball Bearing, (DE) suitable for pump set 15HP to 30HP.
Ball Bearing (NDE) suitable for pump set 15HP to 30HP.
Impeller suitable for pump set 15HP to 30HP.
Pump Shaft suitable for pump set 15HP to 30HP.
Lantern Ring suitable for pump set 15HP to 30HP.
Mechanical Seal suitable for pump set 15HP to 30HP.
Water Deflector suitable for pump set 15HP to 30HP.
Sleeve suitable for pump set 15HP to 30HP.
Key Impeller suitable for pump set 15HP to 30HP.
Gland Packing suitable for pump set 15HP to 30HP.
Dismantling taking out Induction motor 90 Hp to 100 Hp from foundation by removing electric connection, coupling carefully and carrying to wksp & back for repair /rewinding complete and reassemble and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection and cable connection complete including testing, commissioning, proper alignment all as specified and directed.
Dismantling taking out Induction motor 15 Hp to 30 Hp from foundation by removing electric connection, coupling carefully and carrying to wksp & back for repair /rewinding complete and reassemble and fixing to original position after repair/overhauling with nuts, bolts, washers, pipe connection and cable connection complete including testing, commissioning, proper alignment all as specified and directed.
M&L for complete rewinding of motor any type after cutting, taking out old damaged winding from stator core, cleaning of slots, providing proper insulating materials/lock strip in the slots, rewinding with existing size of super enamelled copper wire, supply and replacement of defective bearing of proper size, insulation, varnishing and drying and proper testing after rewinding for motor capacity 90 HP to 100 HP
M&L for complete rewinding of motor any type after cutting, taking out old damaged winding from stator core, cleaning of slots, providing proper insulating materials/lock strip in the slots, rewinding with existing size of super enamelled copper wire, supply and replacement of defective bearing of proper size, insulation, varnishing and drying and proper testing after rewinding for the following sizes of motor capacity 15 HP to 30 HP
Repair/maintenance/overhauling in situ of Pump starter panel by dismantling taking out old damaged panel wiring, replacement of Contactor, relays, Timer, Push button, single phase preventer, voltmeter, ammeter, LED indicator and other miscellaneous items as required and testing complete after completion of work. Note: spares required for the repairs will be measured and paid under respective items.
AC Contactor, 3 pole, 3 ph, 415V, AC, 50Hz, Type- ML-2 to ML-5 , Make- L&T, or equivalent of Schneider/ ABB /C&S
AC side mounting add on aux contact block for contactor Make- L&T, or equivelent of Schneider/ABB/C&S
AC front add on aux contact block Make- L&T, or equivalent of Schneider/ABB/C&S
Thermal overload relays, relay range 9 amp to 15 amps as applicable, Make-L&T or equivalent of Schneider/ABB/Crompton/C&S
Electronic Timer, 3 - 30 Sec 415V Make- L&T, or equivalent of Schneider/C&S/Minilac
Motor protection relay, O/L range 1.2 amps, Make-L&T or equivalent of Schneider/ABB/Crompton/C&S
Single phase preventor relay, Make- L&T or equivalent of Schneider/ABB/C&S /Minilac
LED indicator R-Y-B
Starter Push button Red/green
Supply and replacement of submersible flat copper cable conductor 3 core 10 Sqmm 1100 volts grade complete all as specified and directed by Engineer in charge. Make Finolex/National/CCI
Repair/Maint of unserviceable submersible pump of 15 HP capacity by lifting from UG sump and dismantling and strip opening of 3 phase 415volts, AC submersible pump set, transporting the pumping set to workshop for repair including replacement of unserviceable parts of pump such as GM impeller, necking, bowl assembly, bushes , coupling, lock, sand cap, CI intermediate bowl, S/S pump shaft etc including testing at site on full load complete all as specified and directed by Engr in charge. NOTE:- I The defective parts such as pump shaft, impellor, necking, coupling, lock, gun metal bushes, sand cap etc will be measured and paid separately under respective items II. Rates for repair, servicing, complete checking, machine work what ever is reqd cutting,grinding, polishing and transportation from site to workshop and back are deemed to be included in the quoted rates.
Supply and fix Pump shaft stainless steel sleeve suitable size 15HP submersible pump
Supply and fix Impeller bronze/gun metal of suitable for 15HP submersible pumps.
Supply and fix Neck ring gun metal of suitable size for 15HP
Supply and fix Gun metal bowl bushes suitable for submersible pump of 15 HP.
Supply and fix Cast iron suction /discharge case bowl of suitable size for 15HP
Supply and fix Sand cap of suitable size from 15HP
Supply and fix Cast iron inter mediate bowl of suitable size from 15HP.
Repair/servicing of unserviceable submersible motor of 15HP, 3 phase 415volts by lifting from UG sump, transporting to workshop, dismantling and strip opening re-winding with PVC insulated superior quality water proof copper winding wire of suitable size/gauge and nos of turns including replacement of insulating materials incl new submersible cable of suitable size for connection from motor to outside upto a length of 1.5 mtrs and reassembling including testing at site on full load complete all as specified and directed by Engr in charge. NOTE:- I The defective parts such as Thrust plate/bearing/sleev/pad/bush end etc will be measured and paid separately under relevant items as II Rates for repair, servicing, complete checking, machine work whatever is reqd cutting, grinding etc complete and transportation from site to workshop and backs are deemed to be included in the quoted rate.
Supply and replacement of thrust plate suitable for submersible motor 15 HP
Supply and replacement of thrust pad suitable for submersible motor 15 HP
Supply and replacement of bearing suitable for submersible motor 15 HP
Supply and replacement of bush suitable for submersible motor 15 HP
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing capping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one light point or one fan point or one call bell point controlled by one, one way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealed box for mounting of switch, regulators or bell push and casing capping terminal box for mounting ceiling rose/ holders etc incl dismantling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing capping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealed box for mounting of switch, socket incl dismantling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing capping of required size with all fittings and accessories alongwith one single core green colour PVC insulated 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one 5 amps socket point on same board with other switches incl dismantling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn in and including PVC casing capping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly for one two way light point controlled by two, two way switch including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealed box for mounting of switch etc incl dismantling taking down old unserviceable point wiring and making good to disturbed surfaces all as specified and directed.
M & L for surface point wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn in and including PVC casing capping of required size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly for one 16amps socket (Power) point independent including PVC switch board of required size or 3mm thick hylam sheet screwed with 04 nos cadmium coated screws & cup washer on existing MS concealed box for mounting of switch, socket all as specified and directed.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm (Nominal area) drawn through in and including PVC casing capping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly incl dismantling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm (Nominal area) drawn through in and including PVC casing capping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 2.5 sqmm as earth lead and connected to earth dolly incl dismantling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.00 sqmm (Nominal area) drawn through in and including PVC casing capping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 4.00 sqmm as earth lead and connected to earth dolly incl dismantling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.00 sqmm (Nominal area) drawn through in and including PVC casing capping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FRLSH Copper conductor cable of size 6.0 sqmm as earth lead and connected to earth dolly incl dismantling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a)Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
M & L for surface sub main wiring with two single core PVC insulated unsheathed 1100 volt grade multi stranded FR Copper conductor cable of size 10.00 sqmm (Nominal area) drawn through in and including PVC casing capping/PVC conduit size with all fittings and accessories alongwith one single core green colour PVC insulated unsheathed 1100 volt grade multi stranded FR Copper conductor cable of size 10.00 sqmm as earth lead and connected to earth dolly incl dismantling taking down old unserviceable wiring and making good to disturbed surfaces all as specified and directed. NOTE: (a) Two run of cable with one run of earth wire and one run of casing capping/conduit will be measured as one length.
S&F 5 Amp switch piano type single pole one way incl dismantling taking down unsv one all as specified and as directed
S&F 5 Amp switch piano type single pole two way incl dismantling taking down unsv one all as specified and as directed
S&F bell push piano type one way 240 volt incl dismaentling taking down unsv one . all as specified and as directed
S&F socket flush type 6 amps, 5 pin, 230v incl dismantling taking down unsv one all as specified and as directed
S&F switch socket combination multipurpose 2-in-1 flush type 3 pin 16 amps and 3 pin 6 amps, 230v incl dismantling taking down unsv one all as specified and as directed
S&F lamp Holder insulated body with back plate for batten fitting incl dismantling taking down unsv one all as specified and as directed
S&F LED lamp 12 watt, CDL, B-22 cap, (Pin type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips
S&F LED lamp 12 watt, CDL, E-27 cap, (Thread type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips
S&F LED lamp 3 watt, CDL, E-14 cap, (Small thread type), 230V, PF-0.95 (min) incl dismantling taking out unsv CFL. Make-HPL/Havells/CG/Bajaj/ Philips
S&F ceiling rose surface Bakelite three terminal incl dismantling taking down unsv one all as specified and as directed.
S&F bell electric AC 240 volt, 50 HZ. incl dismantling taking down unsv one all as specified and as directed.
S&F flush type electronic fan regulator with 5 step type,120 W, AC 240 Volts, 50 Hz incl dismantling taking down unsv one all as specified and as directed.
S&F MCB, Single Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4085-87 to 4085-95 of Legrand or equivalent of Schneider/ABB.
S&F MCB, Double Pole, 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4065- 00 of Legrand or equivalent of Schneider/ABB
S&F MCB, SPN , 6 to 32 amps, 240 Volts, 10 KA breaking cap, ‘’C” curve incl dismantling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4086-09 to 4086-17of Legrand or equivalent of Schneider/ABB
S&F RCBO, 2 pole, rated current 16 amps, Sensitivity 300 mA, 240 Volts incl dismantling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4113-99 of Legrand or equivalent of Schneider/ABB
S&F MCB, Four Pole, 40 to 63 amps, 415 Volts incl dismantling taking down unsv one all as specified and directed. MAKE- Cat Part No- 4087-92 to 4087-94 of Legrand or equivalent of Schneider/ABB
S&F Sheet metal enclosure two way, IP-30 incl dismantling taking down unsv one all as specified and directed. MAKE- Cat Part No-5077 91 of Legrand or equivalent of Schneider/ABB.
S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 4 way incl dismantling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 10 of Legrand or equivalent of Schneider/ABB
S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts, 8 way incl dismantling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 11 of Legrand or equivalent of Schneider/ABB
S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, SPN, 230 Volts,12 way incl dismantling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5076 12 of Legrand or equivalent of Schneider/ABB
S&F MCB distribution board, IP 43 protection, Double door, metal enclosure, TPN, 415 Volts, 4 way incl dismantling taking down unsv one all as specified and directed. MAKE- Cat Part No- 5077 25 of Legrand or equivalent of Schneider/ABB
S&F Metal plug and socket board with MCB SP 20 amp, 16 KA incl dismantling taking down unsv one all as specified and directed. MAKE- Cat Part No- 6078-41 of Legrand or equivalent of Schneider/ABB
S&F PVC rectangular switch board of size 300mmx 250mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismantling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
S&F PVC rectangular switch board of size 200mmx 150mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismantling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
S&F PVC rectangular switch board of size 175mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismantling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
S&F PVC rectangular switch board of size 100mmx 100mm x50mm incl necessary cutting slots for mounting switch sockets etc incl dismantling taking down unsv one all as specified and directed. MAKE- Presto Teak/Press Fit/Plaza.
S&F Hylam Sheet 3mm thick on existing concealed MS/CI rectangular or Squar or round box with 04 nos cadmium coated screws and cup washer incl cutting slots for mounting switch/socket/fan regulator/ batten holder etc incl dismantling taking down unsv one
S&F Square shaped recess mounted LED slim Flat panel suitable for fixing in aluminium framed ceiling, 36 watt, 2'x2'size, complete with all accessories and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable incl dismantling taking down unsv fitting any type all as specified and directed. Make-CG, Cat Part No LCPL-36-CDL (2x2) (Aura) or equivalent in Bajaj/Philips/HPL/Havells
S&F LED tube 20 watt to existing fluorescent FTL (T-8) fitting surface mounted after dismantling electronic ballast, internal wiring and complete rewiring with 0.5 sqmm copper flexible conductor FRLSH on connector block to one end of Bipi holder and including connecting up to ceiling rose with 0.5 sqmm two core flexible copper conductor cable all as specified and directed. Make-Cat Part No HLPLEDT8PCP20CW HPL or equivalent in Bajaj/Philips/Crompton Greaves /Havells
S&F industrial box type LED Batten with CRCA body, pre coated with white and prewired suitable for LED tube 1x18/20 watt 4'long incl dismantling taking down unsv fitting any type all as specified and directed. Make-HPL, Cat Part No-HLPLEDT801WT or equivalent of Bajaj/Philips/CG/Havells
S&F LED tube box type with LED tube, 2' long, 09 watt, 230 Volts, complete with all accessories internally pre wired and including connecting up to ceiling rose with 0.5 sqmm two core copper flexible conductor cable with mounting casing box 2 nos incl dismantling taking down unsv fitting any type all as specified and directed. Make-HPL Cat Part No- CG LTC9CDL or equivalent in Bajaj/Philips/HPL/Havells
REPAIR TO CEILING FANS WITH FOLLOWING ITEMS OF WORK:- M&L for Rewinding of Ceiling fan 1400 mm sweep after dismanting complete motor assy, bearings, bushings, removal of burnt copper wire, cleaning of core, inserting proper insulating paper in slots, winding with and as per existing size/turn of super enamelled copper wire, heating, varnishing, replacement of unsv bearings / bushings, assemble of rotor and stator unit with capacitor, connecting wire, down rod, blades and testing complete. Note: 1. Contractor will collect fans from complaint cells of specified area and bring back to complaint cell after repair. Cost of transportation will be inclusive of quoted rate. 2. Spares require for replacement such as bearing, Bushing, capacitor shall be measured and paid separately as supply & Fixing only. 3. Cost of Connector bock and capacitor holder shall be inclusive of the quoted rate.
All as per item No- 186 here-in-above but for Ceiling fan 1200 mm sweep
All as per item No- 186 here-in-above but for Exhaust fan 450 mm sweep industrial type.
All as per item No- 186 here-in-above but for Exhaust fan 300 mm sweep industrial type.
All as per item No- 186 here-in-above but for Exhaust fan 300 mm sweep domestic type.
S&F ball bearing No 6201/6202/6203/6204 of SKF/Tata/NBC.
S&F G.M. Bush bearing for ceiling fan as per existing pattern.
S&F capacitor AC for 230 volts 50 Hz of capacity 1.8 Mfd.
S&F capacitor AC for 230 volts 50 Hz of capacity 2.0/2.25/2.5 Mfd.
S&F capacitor AC for 230 volts 50 Hz of capacity 3.15 Mfd.
S&F capacitor AC for 230 volts 50 Hz of capacity 4.0 Mfd.
REPAIR TO STORAGE WATER HEATER COMPRISING OF THE FOLLOWING ITEMS OF WORKS:- S&F PVC insulated PVC sheathed copper flexible wire multi strand 4sqmm 3 core, ISI marked
S&F in repair thermostat ISI marked suitable for geysers 25 Ltrs to 50 Ltrs Capacity. Make- Bajaj/Venus/Recold all as specified and directed.
S&F in repair fusible plug ISI marked suitable for 25and 50 ltrs capacity Geysers all as specified and directed.
S&F in repair heating element ISI Marked round/triangular bas, push type or thread type including rubber washers for 1.5/2.0 KW all as specified and directed.
S&F in repair inner water container ISI Marked made of SS, vertical or horizontal type for 25/50 ltr capacity geyser all as specified and directed.
S&F in repair of apparatus plate ISI marked suitable for vertical/horizontal type Geyser 25 or 50 ltr cap all as specified and directed.
S&F in repair heavy duty PVC connections pipe with brass hexagonal adopter sat both side 15mm dia and 450mm long for hot /cold water all as specified and directed.
M&L for testing of earth resistance value of building earth for electrical purpose, using analog/digital earth resistance tester by suitably inserting spikes as per norms and recording earth resistance value of building in presence of MES Rep and User rep and submission of recorded value in form of hard copy duly signed all as specified and directed.
M & L for Earthing complete with galvanised steel pipe electrode, 40mm bore, medium grade, 3 mtr long buried directly and vertically in ground with top edge at ground level after making bore hole of size not less than 300 mm dia and 3.0 Mtr long using suitable mechanical drilling rig (for drilling near the specified bldg), connected with galvanised steel earthing lead of 4mm dia all as shown in Plate No-2, connected to the earthing test point, concrete pit in PCC 1:3:6 type C-2with RCC precast pit cover slab 400mmx400mmx80mm with handle for lifting made out of 8mm dia MS rod, funnel, wire mesh, 15 mm dia light grade GI tubing for protection of GI wire 4mm dia, charcoal and salt in alternate 150mm thick layers around GI earth pipe, including necessary returning filling in & removal all as specified or indicated in SSR Part-I, including testing to achieve earth resistance value as per IS specification on completion.
SKS Electricals
JP ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .