Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹86.9 LAccepted-AOC 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | L1 | Accepted-AOC The lowest bidder. | |
| 2 | L2₹92.2 L+₹2.5 L (2.75%)Rejected-AOC HARSHA KUTHI SIDDHESWARITALA ROAD MONIRAMPORE BARRACKPORE DIST 24 PARGANAS NORTH KOLKATA 700120 W B | KOLKATA | 24 PARGANAS NORTH | WEST BENGAL | 700120 | L2 | Rejected-AOC Other than the lowest bidder. | |
| 3 | L3₹92.7 L+₹3.0 L (3.33%)Rejected-AOC 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | L3 | Rejected-AOC Other than the lowest bidder. | |
| 4 | L4₹94.5 L+₹4.8 L (5.35%)Rejected-AOC 14 4A KALI PRASAD C HAKRABORTY ST CAL KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | L4 | Rejected-AOC Other than the lowest bidder. | |
| 5 | Rejected-Technical 19 1A BOSE PUKAR ROAD KASBA GROUND FLOOR KOLKATA 700042 | KOLKATA | KOLKATA | WEST BENGAL | 700042 | - | Rejected-Technical Not Admitted |
Tender Value
₹1.0 Cr
EMD Value
₹1.8 L
Closing Date
7 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COMMANDER WORKS ENGINEER
Commander Works Engineers (Sub) Military Engineer Services PO Barrackpore, Dist 24 Pgns (N) Kolkata 700120 (W.B)
COMPREHENSIVE MAINTENANCE TO MARRIED IN LIVING OFFRS ACCN TCP, FAFA, DODA BH AREA AND OFFRS MESS AT BARRACKPORE UNDER GE BARRACKPORE
2024_MES_679129_1
CWE/BKP/14 OF 2024-2025
Open Tender
Civil Works
Item Rate
360 days
GE BARRACKPORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
GE BARRACKPORE
₹1.8 L
Yes
29 Dec 2024
11 Oct 2024
14 Nov 2024
11 Oct 2024
7 Nov 2024
24 Oct 2024
Amount
M&L for two coat of oil bound distemper over one coat of clearcolle primer on old decorated surfaces complete removal of existing treatment surface s ,inciuding stipping nails, holes ,filling the cracks with 3 mm thick wall care putty etc complete all as specified and directed.
M&L for preparation of old decorated surfaces on wall inciuding stopping nails, holes ,filling the cracks and apply one coat of oil bound distemper etc complete all as specified and directed.
M&L for one coat of white wash on old decorated surfacafter preparation of old plastered celing surfaces and complete removal of existing treatment of ceiling etc complete all as specified and directed
M&L for preparation of old decorated surfaces on ceiling inciuding stopping nails, holes ,filling the cracks and apply one coat of oil bound distemper etc complete all as specified and directed.
M&L for one coat of cement base paint after preparation of old decorated surfaces of walls inciuding stipping nails, holes ,filling the cracks with putty by washing, rubbing down etc complete all as specified and directed
M&L for preparation of old painted wooden surfaces exc 10cm width or girth and apply one coat of synthetic enamel paint etc complete all as specified and directed.
M & L for Complete removal of existing wall surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gms/litre and UV resistance as per IS 15489 : 2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadeICompany Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over old surfaces etc complete all as specified and directed.
M&L for preparation of old painted steel surfaces exc 10cm width or girth and apply one coat of synthetic enamel paint etc complete all as specified and directed.
Demolition of brick work built in cement mortar including all quoins, archer, pillar etc complete all as specified and directed
Material and labour for brickwork in cement mortar (1:6) withsub class `B' bricks straight orcurved on plan exceeding 6mmean radius with old size bricksas in walls etc complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) etc complete all as specified and directed.
Taking down cement plaster on brick or stone or concrete surfaces of wall etc , including raking out joints , hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for rendering 15mm thick on fair face of brick works or concrete surfaces of walls with CM (1:6) and finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for rendering 15mm thick on other than fair face of brick works or concrete surfaces of walls with CM (1:4) and finished even and smooth without using extra cement with WPC @100 ml per 50 kg of cement or all as per manufatucring Instruction etc complete all as specified and directed.
M&L for rendering 5mm thick in CM (1:3) to fair face of brick works or concrete surfaces of ceiling surfaces etc complete all as specified and directed.
M&L for two coat of distemper oil emulsion after preparation of new plastered surfaces of wall over a coat of alkali resistant cement primer etc complete all as specified and directed.
M&L for Three coats of white washing after preparation of new plastered surfaces of Ceiling complete all as specified and directed.
M&L for Two coat of cement base paint after preparation of new plastered surfaces over a coat of alkali resistant cement primar of wallsetc complete all as specified and directed.
M & L for applying applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50gms/litre and UV resistance as per IS 15489 : 2004, Alkali & fungal resistance, dirt resistance exterior paint of required shadeICompany Depot Tinted) with silicon additives @ 1.43 litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces etc complete all as specified and directed.
M&L for two coat of oil bound distemper over a coat of alkali resistant cement primar newly plastered ceiling including preparation of surface complete all as specified and as directed
Dismantling structural steel work including doors, gates but excluding framed truss etc complete all as specified and directed.
S&F steel window with side hung shutter with box type hinges shutters with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded etc complete all as specified and directed.
M&L for preparation of new steel surface over 10cm girth or width and apply two coat synthetic enamel paint over a coat of red oxide primer etc complete all as specified and directed.
S&F MS work ( MS angle ) as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat section or tubular sections) including distance pieces, cleats etc etc including necessary cutting, welding etc complete Fe-410 w gde E-250 quallity A etc complete all as specified and directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering etc complete all as specified and directed
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws etc complete all as specified and directed
Dismantling floor hearth or wall tiling including cement mortar bedding ( but not backing) and removing rubbish off the premises etc complete all as specified and directed.
S&F non skid ceramic (Joint Free)coloured tiles of 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.18 sqm but n.exc 0.38 sqm in floors etc with 15mm thick screed bed or bedding layer of mortar for laying floor finishes in cm (1:6), set and joint free non skid tiles in neat cement slurry and pointed in coloured cement etc complete all as specified and directed.
All as per item No 29 hereinbefore but in skirting including 10mm thick plastering for backing coat in cement mortar (1:4).
S&F Non skid ceramic (Joint Free) coloured tiles of 7 to 8mm thick (Square/rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm in floors etc with 15mm thick screed bed or bedding layer of mortar for laying floor finishes in CM (1:6), set and jointed in neat cement slurry and pointed in coloured cement etc complete all as specified and directed.
All as per item No 31 hereinbefore but in skirting including 10mm thick plastering for backing coat in cement mortar (1:4).
S&F Granite work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade of following types etc complete all as specified and directed.
M&L for coloured Chequred cement concrete tile 30 cm x 30 cm x 25 mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and pigment over and including 20 mm thick cement screed bed in CM (1:6) etc complete all as specified and directed.
S&F Glazed ceramic coloured tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including 10mm thick rendering or bedding layer of cement mortar (1:4) for vertical surfaces etc complete all as specified and directed.
Demolition of Cement concrete of any description and in any position not otherwise specifically provided for complete all as directed.
M&L for 40mm thick cement concrete (1:2:4), type B1, using 20mm graded stone aggregate in floors finishing surfaces even and fair (with using extra cement) etc complete all as specified and directed.
M&L for 75 mm thick PCC (1:3:6 ) type C2 using 40 mm graded stone aggregate as in floors,hard standing, sub base floor, plinth protection etc or similar work finishing cement concrete surfaces even & smooth without using extra cement etc complete all as specified and directed.
Demolition of cement concrete as in roofs, floors (other than ground floors), beams stair cases, landing, chajjas and similar susptnded work etc complete all as specified and directed.
M&L for PCC (1:2:4), type B0 (using 12.5mm graded stone aggregate) averaging 40mm thick as in roof padding / levelling course with WPC @ 100ml per 50 Kg cement all as specified including finished the surface even and smooth with using extra cement etc complete all as specified and directed. (Note : WPC shall be measured and paid separately under relevant item of Sch 'A').
M&L for 10mm thick rendering in CM (1:3) on fair face of brick work mixed with water proofing liquid compound on walls and roof surfaces finished even and smooth using extra cement etc complete all as specified & directed. (Note : WPC shall be mixed @ 100 ml / 50 Kg bag of cement or as recommended by manufacturer and the same shall be measured and paid seperately).
M&L for providing, cement concrete (1:2:4) type B0 using 12.5mm graded stone aggregate as in roof kerbs or mud stops, top of chajjas, coping, basement for water tank etc rounded or chamferred on edges finishing the surface even and smooth complete all as specified and directed.
M&L for APP based polymeric membrane minimum weighing 3.6 Kg/Sqm and minimum 3mm thick reinforced with polyster non wove fabric (Wt not less than 150 gms / sqm) laid on primed surface with side over lap of 80 mm ans end overlap of 100 mm using butane torch or by LP gas torching and sealing all joints etc and ensuring complete thermo fusing and applying one coat of aluminum Paint over it complete all as specified & directed .
Supply only liquid water proofing compound complete as specified.
Removing plant including roots by dismantling of brick work PCC/RCC including necessary scaffolding any type in any location/position i.e. roof, parapet wall near pipes etc and applying concentred acid after removing roots for preventing the regrowth and making good of disturbed portion using PCC (1:2:4) type B0 & 10mm thick plaster in CM (1:3) size of disturbed portion 150mm x 150mm x 200mm complete all as specified and directed.
Taking down chowkats with shutters (without taking down of shutter from the frames) n. exc 1.50 Sqm each etc complete as directed.
Taking down chowkats with shutters (without taking down of shutter from the frames) exc 1.50 Sqm and n.exc 4.00 Sqm each etc complete as directed.
Taking down shutter of any description exc 1.00 Sqm and n.exc 2 Sqm each etc complete all as specified and directed.
Taking down shutter of any description n exc 1sqm each etc complete all as specified and directed.
Refixing Shutter of any description exc 1 sqm but n exc 2 sqm each as same opening etc complete as directed
S&F solid PVC door frames of size 50mm x 47mm made out of 5mm plain cover fillet colour PVC sheet reinforced with MS square tube for toilet etc complete all as specified and directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing etc complete all as specified and directed.
S & F Solid PVC frame (single Rebated) of size 60mm x 30mm made out of solid PVC foam with homogenous fine cellular structure having smooth outer integral skin with suitable metal stiffer and fixed with 100 x 8 sheet metal CSK screws complete all as specified and directed. (Note ;- Door frame shall be water proof, termite proof, elegant and should have excellent screws holding strength to fix hinges and hold doors properly for a long life)
Supply and fix 30mm thick single piece, coloured ABC (ACRYLONITRILE BRUTADINE STYRENE) coated, PUF filled door shutters with PUF (Poly Urethane Foam) insulation of minimum density 40 Kg/Cum filled in between two ABS sheets of thickness 1.2mm (min), border covered with insitu pasted ABS strips of width equal to thickness of door shutters, 1.2mm thickness, reinforced with two number 10mm CTD bars, pre-embedded with wooden blocks of suitable sizes for receiving hinges, tower / sliding bolts, towel rails, handles etc, with/without embossed pattern etc complete all as specified and directed.
S&F 2nd class hard wood plain solid, straight chowkats and frames wrought,frame rebated on the solid,rounded or chamfered,put together with glue pinned at joints etc complete all as specified and directed
S&F 35mm thick 2nd class hard wood plain framed pannelled shutter (three panel) with lock rail and panel of 12mm veneered particle board of exterior grade with commercial veneering on both faces. The size of rail and style as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated etc complete all as specified and directed.
S & F 35mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides etc complete all as specified and directed
S&F 35 mm thick factory made 2nd class hardwood glazed and skeleton shutter open rebated and prepared to receive glass/gangue (with sash bars) edges of forming plain chamfered or rounded fitted with cut and mitred bead for securing glass/ gauged etc size of member of shutter as per Pt-I, Section 8, Clause 8.20 (a) etc complete all as specified and directed.
S&F 30mm thick skeliton/gauzed shutter open rebated and prepared to receive glass gauged etc(without sash bars) edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24(a), supplied and fitted to etc complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples in window and door etc complete all as specified and directed.
S&F in repairs for stainless steel wire cloth 0.36mm nominal dia of wire and average width of aparture 1.40mm and fixed with stainless steel wire staples in window and door etc complete all as specified and directed.
S&F 3mm thick sheet glass , ordinary quality and glzing with oil putty in square n.exc 0.5 sqm in each pane in new windows etc complete all as specified and directed.
S&F 3mm thick sheet glass, ordinary quality and glzing with oil putty in square n.exc 0.5 sqm in each pane including hacking out old broken glass ( any thickness, size , quality or description ) from wooden frames glazed with putty or fixed with beads etc complete all as specified and directed.
S&F 3 mm thick figured glass, pin headed type and glazing with oil putty or wooden beads in squares not exceeding 0.5 Sqm in each pane including hacking out old broken glass ( any thickness, size , quality or description ) from wooden frames glazed with putty or fixed with beads etc complete all as specified and directed.
S&F in repairs curtain rod of aluminium alloy 25 mm dia complete all as specified and directed.
S&F MS bracket powder coated of best approved quality suitable for fixing 25 mm bore Cromium plated (heavy) rod, fixed on wall etc complete all as specified and directed.
S & F in repairs, using HDHMR Board 18mm thick both side laminated any colour, 18mm thick shutter, vertical support and horizontal shelfs including necessary fitting of screws in kitchen cupboard / bedroom cupboard etc complete all as specified and directed.
S & F in repairs soft close stainless steel hinges 75mm etc complete all as specified and directed.
S & F in repairs gunmetal handle 125mm etc complete all as specified and directed (Handle : Rich or techno commercially equivalent).
S & F in repairs stainless steel telescoping channel for drawer including necessary fitting upto length upto 800mm complete all as specified and directed.
S&F in repairs for 18 mm thick prelaminated particle board exterior grade prelaminated both side with decorative choice lamination fixet timber frame work cup board shutter complete all as specified and directed
S&F in repairs, contineous piano type hinges mild steel bright finish or electro galvanised , size of flaps (when open) 40 mm complete all as specified and directed.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 etc complete all as specified and directed.
M&L for PCC (1:2:4 ) type B1( using 20 mm graded aggregate ) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbsetc, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, etc complete all as specified and directed.
S&F 100 mm long medium weight cold roll mild steel butt hinges etc complete all as specified and directed.
S&F 75 mm long medium weight cold roll mild steel butt hinges etc complete all as specified and directed.
S&F 150 mm aluminum Handle Cast type, anodised etc complete all as specified and directed.
S&F 200 mm aluminum , anodised, barrel tower bolts of extruded section etc complete all as specified and directed.
S&F 150 mm Aluminium, anodised, barrel tower bolts of extruded section and fixed etc complete all as specified and directed.
S&F 250mm aluminum alloy, anodised , sliding door bolt with hasp and staple ( bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy etc complete all as specified and directed.
S&F in repairs Aluminum extruded body door coser hydraulically regulated designation No 3 , universal type , suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 85 kg etc complete all as specified and directed.
S&F in repairs 300 mm long , MS ordinary rat tail rod pattern spring including roller & roller plate complete all as specified and as directed.
S&F 2nd class hard wood small fittings such as brackets of any type, latch and hinge blocks, shaped door and wondiw stops and the like, including all necessary labours ; articles n.exc 200 cum each including provision of 50 mm MS Butt hinges etc complete all as specified & directed.
M&L for preparation of new wood surface over 10 cm girth or width and apply two coat synthetic enamel paint over a coat of pink primer etc complete all as specified and directed.
S&F Anodised (Power coating of minimum thickness 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing after and including taking down of existing old unserviceable frame. complete all as specified.
S&F in repairs Anodised (Powder coating of minimum thickness 50 micron) aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, suitable fixing arrangement , anodised aluminum snap beading screws etc complete all as specified and directed.
M&L Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed including taking down old unserviceable floor spring of any type complete all as directed.
S&F in repairs Anodised (Powder coating of minimum thickness 50 micron) aluminium window and Ventilator shutters sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as suitable handle/locking arrangement as required complete all as specified and directed.
S&F in repairs Stainless steel plate rack (0.63 mm thick s/s sheet) of size 775 X900 X 250 mm fixed in wall with Stainless steel screw of suitable size complete all as specified and directed.
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets etc complete all as specified and directed.
S&F false ceiling with exposed metal (PPGI) framework/ “Tee” Grid, including provision of suspended Tee gird false ceiling using “T” Gird System – powder coated GI (PPGI) exposed grid false ceiling suspension system in grid size 600mm x 600mm with main runner 32 x 24mm x 0.3mm thick, cross tee 26mm x 24mm x 0.3mm thick and wall angle 24mm x 24mm x 0.40mm thick using 4mm thick non asbestos fibre cement board (oceanic) of size 595 x 595mm, an asbestos Free fibre cement board manufacture using high Pressure System Curing technology. T gird Framing is suspended using 4mm GI/MS bar hanger fixed with steel dash fasteners or iron purlin from the roof with adjustment clip, also providing provisions for light fixtures, air conditioning diffusers and ducts, sprinklers, smoke detectors etc. The main runners to be secured to structural soffit by hanger @ 1220mm maximum c/c. The last hanger at the end of each main runner should not be placed at not more that 300mm from the adjacent wall. 1220mm/600mm Cross Tee to be interlocked between main runners @ 600mm c/c, so as to from 600mm x 600mm or 1200mm x 600mm grid, confirming IS 14862 & type B category III of ISO 8336, tested as per AS 1530 part – 3 & B. S- 476 part 4,5,6,7 & 8 should be placed in Gird module to form complete as per the drawing & directions of Engineer-in-Charge.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing etc complete all as specified and directed.
S&F Solid PVC Wall Lining consisting of 5mm thick single side prelam and other side Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing etc complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for etc complete all as specified and directed.
M&L for providing precast cement concrete (1:2:4), type B1, ( using 20 mm graded stone aggregrate) as in cover slab and set in cement mortar (1:6), including nacessary form work etc complete all as specified and directed.
M&L for TMT bars 10mm dia and over cut to length bent to shape required incl cranking, bending spirally for hooping for columns, hooking ends and binding with and incl mild steel wire annealed, not less than 0.9mm dia etc complete all as specified and directed.
Ditto as item No. 96 but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders
Cutting chases, pinning in making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good exc 10 cm but not exc 20 cm etc complete all as specified and directed.
S&F in repairs 2 Way Bib cock for 15 mm bore pipe, cast copper alloy fancy type chromium plated complete all as specified and directed.
S&F in repairs CP Soap dish complete all as specified and directed.
S&F in repairs for 15 mm Bib taps, cast copper alloy fancy type chromium plated with capstan head screwed down screwed for iron pipe etc. complete all as specified and directed.
S&F in repairs 15mm dia Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed complete as in repair (Minimum weight 15mm-90 gms) all as specified and directed.
S&F in repairs 15mm bore angular stop valve fancy type chromium plated with cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed.
S&F in repairs 15mm bore stop valve fancy type chromium plated with long shank and cup (Concealed type) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions all as specified and directed.
S&F in repairs Brass chromium plated Tubular towel rail 20mm dia, D type, 60cm long between flanges etc complete all as specified and directed.
S&F in repairs for Vitreous China wash basin, white, flat back, size 580 X 450mm, excluding taps, waste, chain and plug and porcelain stopper but including brackets including cutting for and pinning in ends of brackets or erecting stand complete as in repair all as specified and directed.
S&F in repairs 15mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified and directed..
S&F in rapairs sinks with drainage board made of stainless steel lmm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S&F in repairs, sinks made of stainless steel 1 mm thk kitchen with plugs, washers and wastes incl bedding in cement mortar on to dwarf wall or incl fixing cantilever brackets and connecting union to pipe overall size 495mm X 420mm bowl size size 410mm X 330 mm X 160mm complete all as specified and directed.
S&F in repairs health faucet fixed to EWC and Angular Stop Cock complete all as specified and directed.
S&F in repairs for brass chromium plated shower rose 125 mm size with swivel joint including fixing to 15mm dia steel pipe or union etc complete all as specified and directed.
S&F in repairs for 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor complete all as specified and directed.
S&F in repairs vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests (excluding flushing cistern and flush pipe)including connection to trap, and to flushing pipe, anti-syphonage pipe etccomplete including making good to floors with PCC bedding (1:5:10) type E2 using 40mm nominal brick ballast and connection to trap with cement mortar all as specified, and making good to floor including demilition of PCC / Lime concrete bedding existing pan complete all as specified and directed.
S&F in repairs Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) front or back inlet including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe, etc and making good to floor complete all as specified and directed.
S&F in repairs plastic water closet seat, white closed patern withflat bottom and cover and mild steelcromium plated or aluminium hinging device complete all as specified and directed.
S&F in repairs for Vitreous China Urinals, bowl type white (excluding flushing cistern but including flush pipe and waste pipe) complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed.
S&F in repairs 32mm bore PVC Fleixible pipe as in waste pipe for WHB or sink including connection complete all as specified and directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 600mm etc complete all as specified and directed.
Taking down PVC pipe of 32mm/50mm dia incl fittings in any position etc complete all as specified and directed.
S&F LDPE pipes 32mm dia, of pressure rating 6 kg/sqcm fixed to wall or laid in floor etc including necessary pipe fittings and fixing arrangement complete all as specified and directed.
S&F LDPE pipes 50mm dia, of pressure rating 6 kg/sqcm fixed to wall or laid in floor etc including necessary pipe fittings and fixing arrangement complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) of 500 litres capacity hoisted and fixed in position as specified in SSR Part-I, including PVC float valve 25mm dia including dismanting the existing tanks etc complete all as specified and directed.
S & F rotational moulded Polyethylene water storage tank - 1000 liters capacity (cylidrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I incl PVC float valve 25mm dia including dismantling existing tank etc complete all as directed
Cleaning and removing exc 250 litre and not exc 500 Litres all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified and directed
Cleaning and removing exc 500 litre and not exc 1000 Litres all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified and directed
S&F in repairs 20 mm Ball valves high pressure of PTMT with epoxy coat ed Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 2 0mm-210gms) etc complete all as specified and directed.
Taking up or down steel tubing and connections for 15mm bore of pipe etc complete all as directed.
Fixing only 15 mm bore old steel tubing obtained from item No. 128 and connections in new or old position (Walls, ceiling, floors etc) including cleaning, re-fixing the old screw threads etc complete all as specified and directed.
S&F for 15mm dia Tubes, 'medium grade' galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors , wall etc ( surface or concealed type) all as specified and directed.
Taking up or down steel tubing and connections for 20mm bore of pipe etc complete all as directed.
Fixing only 20mm bore old steel tubing obtained from item No. 131 and connections in new or old position (Walls, ceiling, floors etc) including cleaning, re-fixing the old screw threads etc complete all as specified and directed.
S&F for 20mm dia Tubes, 'medium grade' galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors all as specified and directed.
Demolition and breaking up drain pipes PVC or AC pipe set in cement mortar for 75/100mm bore pipe etc complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls etc complete all as specified and directed.
S&F 110mm bore PVC (SWR) bends any radious provided with access door etc complete all as specified and directed.
S&F 110mm bore PVC (SWR) junction single, (Single T) equal or unequal provided with access door etc complete all as specified and directed.
S&F PVC (SWR) branch piece double (double Y) equal or unequal 110mm bore etc complete all as specified and directed etc complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm bore etc complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joint fixed to wall etc complete all as specified and directed.
S&F PVC (SWR) bends with access door of radius 75mm bore etc complete all as specified and directed.
S&F PVC (SWR), junction single, (Single T) with access door equal or unequal 75 mm bore etc complete all as specified and directed.
S&F PVC (SWR) vent cowl 75mm bore etc complete all as specified and directed.
S&F in repairs Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed
S&F in repairs Aluminium Peg hooks/wardrobe hooks (single) 50mm to 60mm etc complete all as specified and directed.
S & F in repairs 150mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor but of brass body and tongue with hard drawn steel spring etc complete all as specified and directed.
S&F for sheet glass 5.50 mm thick ordinary quality and glazing with ail putty in squares exc 0.5 Sqm each pane complete all as specified and directed.
S&F for sheet glass 5.50 mm thick ordinary quality and glazing with ail putty in squares n exc 0.5 Sqm each pane complete all as specified and directed.
Taking down carefully copper/aluminium point wiring (light,fan,bell, socket or power) complete,including fixtures and fittings such as switches, ceiling roses, holders,regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with existing surface and colour shade with putty at necessary holes for smooth finishing complete all as specified and directed complete all as specified and directed.
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade(MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top,bottom,side/back wall knockout for conduit entry from any direction made out of 1.60mm thick suitable for fixing of and including white/Silver/Dark bronze colour modular blanking plate as per number of switch modules flush mounted for fixing of modular switches,sockets,fan regulators, blank plate etc and including above mentioned colour modular plate cover of required modules and including 1.5 Sqmm PVC insulated multistranded FRLSH type unsheathed(Green colour),single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade with putty for smooth finishing complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular box,top cover plate, blank plate,MS box,screws,washers and all modular electrical fixtures are used same make/brand only and including cutting & chasing work at any height and shall be deemed in to included in quoted rate only.) (a) One light point controlled by one switch.
(b) One fan point controlled by one switch and one regulator.
(c) One exhaust fan point controlled by one switch .
(d) One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
(e) One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
(f) One bell/buzzer point controlled by one bell push.
(g) One light point controlled by two 2 way switches.
All as per item No. 150 above, but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:- (a) One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on independent board.
(b) One 6 pin 16/6 amps socket outlet point controlled by one 16 amps switch on same board.
All as per item No. 150 above, but point wiring with 4.0 sqmm and earth conductor of size 4.0 sqmm complete all as specified and directed.
Supply & fixing modular type switch 10 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and directed.
Supply & fixing modular type switch 10 Amps ,2way,single pole,1 module,240V,AC, ISI Marked complete all as specified and directed.
Supply & fixing modular type bell push 10 Amps,1 module, single pole, 240 volts,AC, ISI Marked complete all as specified and directed.
Supply & fixing modular type switch 16 Amps, single pole,1way,1 module,240V,AC, ISI Marked complete all as specified and directed.
Supply & fixing modular type socket shuttered type 6 Amps, 2/3 Pin combined 2 module,240V,AC ISI Marked complete all as specified and directed.
Supply & fixing modular type socket 6 A/16 Amps, 6 Pin combined shuttered socket 2 module, 240V, AC ISI Marked complete all as specified and directed
Supply & fixing red color lighting indication lamp 6 Amps, single pole,240volts,AC,50 Hz suitable for 1 module ISI Marked complete all as specified and directed.
Supply & fixing modular type step fan speed regulator 100/120W, 2 module,230volts,AC, 360 degree rotation 0 to 4 steps, ISI Marked complete all as specified and directed.
Supply & fix angle lamp holder, insulated body with back plate for batten fittings including complete all as specified and directed.
Supply & fix 12W LED lamp all as specified and directed.
Supply & fix ceiling rose, 3 terminal ,PVC/polycarbonate body ISI marked, complete all as specified and directed
Material and labour for point wiring complete with 1.5 sqmm PVC insulated, FRLSH type, ISI marked,conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC casing and caping of size 20 mm, ISI marked or above as required at site with all accessories such as Tee,corner, overlaping connector etc.on walls, roofs and ceilings etc. including concealed MS box factory made of suitable size fabricated out of 1.6mm thick and 50 mm depth, MS sheet suitable for fixing of and including bakelite hylam sheet 3 mm thick fixed flush with wall surface by means of stainless steel cadmium plated screws and cup washers suitable for mounting switches,sockets,fan regulators etc.and including 1.5 Sqmm PVC insulated, multistranded, unsheathed(Green colour),FRLSH type single core copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and directed for the following:-Note:- Accessories such as necessary MS box,screws, cup washers & hylem sheet and including making good etc shall be deemed in to included in quoted rate (a) One light point controlled by one switch.
(b) One fan point controlled by one switch and regulator
(c) One exhaust fan point controlled by one switch.
(d) One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
(e) One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
(f) One bell point controlled by one bell push.
(g) One light point controlled by two 2 way switches.
All as per item No. 171 above, but point wiring with 2.5 sqmm and earth conductor of size 2.5 sqmm complete all as specified and directed for the following:- (a) One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
(b) One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on same board.
Supply & fix switch piano, flush type,single pole, 1 way,6 Amps,240Volts,AC ISI marked complete all as specified and directed.
Supply & fix switch piano, flush type,single pole, 2 way,6 Amps,240volts,AC ISI marked complete all as specified and directed.
Supply & fix bell push,flush type, 6 Amps,240 volts,AC ISI marked complete all as specified and directed.
Supply and fix socket out let 2 in 1,5 pin, 6 Amps,240volts,AC ISI marked complete all as specified and directed.
Supply and fix switch socket combination, flush type, 2 in 1,5pin, 6 Amps,240volts,AC, ISI marked complete all as specified and directed.
Supply and fix switch socket combination, flush type, 2 in 1,6pin, 6/16Amps,240 volts,AC ISI marked complete all as specified and directed.
Supply & fix fan regulator piano type electronic, stepped type, 100 Watts,240Volts,AC,ISI marked complete all as specified and directed.
Supply and fix call bell AC, 230 Volts single pole, multi music type ISI marked, complete all as specified and directed.
S&F in repairs decorative box type 20/22 watt light fitting, pre-wired, and including providing PVC/Wooden round/square block -02 Nos and connected with LED fitting to ceiling rose and including LED tubular lamp of 20 Watt extruded aluminium housing battens equipped with high specifications CISPR 15 complaint electronics driver and PC diffuser with THD <10% complete with complete all as specified and directed.
Supply & fixing in repairs LED light fitting mirror type with high out put diffuser 2 feet, 10 Watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as speicifed and directed.
S & F in repairs LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size including fixing arrangements at any hight with nuts ,screws and washers and connected to ceiling rose complete all as specified and directed.
Supply and fixing in repairs round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fix in repairs recess mounting 2'x2' LED 36 Watt light fitting slimmest LED ceiling panel with best in class aesthetick white powder coated frame blended seamlessly with ceiling layout suitable for 600X600mm mudular ceiling grid and also can be suspended with provided kit and including connecting up with ceiling rose to fitting etc complete all as specified and directed.
Supply & fix in repairs and sheet metal enclosure with metal type AD/DD,415 volts AC,VTPN DB, 8 way+24 modules, flush mounting with 200amps copper busbar, 2 neutral/earth bar and MCCB incomer,FP, and MCB SP /TP as outgoing and complete for IP54 DBs protection and including making good the disturbed surfaces to match with existing surface and colour shade complete all as specified and as directed.
Supply & fix sheet metal enclosure with AD/DD 415 volts AC,TPN,DB, 8way,8+24 modules, flush mounting with 100amps copper busbar, 2 neutral/earth bar and MCB incomer,MCB TPN/FP, and MCB SP as outgoing and complete for IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour shade and including removing old unserviceable item all as specified and as directed.
Supply & fix TPN distribution board 4 way acrylic door 415 volts AC,TPN for flush mounting with 100amps copper busbar,neutral bar,earth bar and MCB incomer of rating upto 100Amps ,MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coatand including removing old unserviceable item all as specified and as directed.
Supply & fix SPN distribution board 8 way acrylic door 240 volts AC,SPN for flush mounting with 200 amps copper busbar,neutral bar,earth bar and MCB incomer of rating upto 200Amps ,MCB SPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat and including removing old unserviceable item all as specified and as directed.
Supply & fix in repairs sheet metal enclosure 2 mm thick,AD/DD 240 volts AC,SPN,DB, 4 way, flush mounting with 200amps copper busbar,neutral bar,earth bar and MCB incomer,MCB SPN/DP, and MCB SP as outgoing for IP 43& IP54 DBs protection and including making good the disturbed surfaces to match with existing surface and colour shade all as specified and as directed.
Supply & fix MCB SP 6 to 32 Amps 10 KA,"C" series,AC,240Volts,50Hz , ISI marked complete all as specified and directed.
Supply & fix and MCB SPN 32 10 KA,"C" series,AC,240Volts,50Hz, ISI marked complete all as specified and directed.
Supply & fix and MCB FP 40 to 63 Amps 10 KA,"C" series,AC,415Volts,50 Hz,ISI Marked complete all as specified and directed.
M & L for sub main wiring complete with 2 run of 10 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 10 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including taking down old unserviceable submain wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed. Note : - Two run of 10 sqmm single core copper conductor cable and one run of 10 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
M & L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked FRLSH type as earth continuity conductor connected to common earth dolly and including taking down old unserviceable submain wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed. Note : - Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit.
M & L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked)cable 1100 volts grade, ISI marked,FRLSH type (conforming to IS-694/1990 as amended) PVC insulated, unsheathed,flexible,multi stranded colour coded cables drawn through and including rigid PVC conduit ISI marked medium grade(MMS) with all connected accessories such as Bend,Tee,Elbow,Short peices etc concealed in wall/roofs/floors and including one run of 4.0 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, ISI marked,FRLSH type as earth continuity conductor connected to common earth dolly and including taking down old unserviceable submain wiring and making good the disturbed surfaces to match with existing surface and colour shade and complete all as specified and directed. Note : - Two run of 4 sqmm single core copper conductor cable and one run of 4.0 sqmm single core copper conductor cable as earth continuity and one run of PVC conduit shall be measured as one unit. Note for item No 201 to 203 :- Making good the disturbed surfaces to match with existing surface and including colour shade and putty, cutting & cheasing work rate will be deemed into quoted rate only.
Supply and fix in repairs flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C 'series, 230 Volts suitable for AC's/Geysers complete all as specified and directed. Note:- MCB SP 20Amps will be deemed to be quoted rate.
Supply and fix MCCB, 100 Amps,4 pole,415 Volts , 16/18KA thermal magnetic type with necessary lugs,thimbles, nuts bolts and washers and including removing old unserviceable item from existing loaction complete all as specified and as directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber 1:3:6 type C1, of size 45X 45X 45 CM,RCC cover 1:2:4 type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed.
Material and labour for galvanized iron tubing 40 mm dia ''medium grade'' in any length including embedded in wall two ends duly welded MS holdfast at two ends of GI pipe and providing PCC as per requirement in wall and making good distribed surfaces complete all as specified and directed.
Supply and fix GI bracket pipe of size 40 mm dia medium grade of 1.2 mtr long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixed on PCC & Steel poles/on wall surfaces and including suitable fabricate MS flat iron clamps of 30X6 mm thick -02 Nos suitable for fixing any place of poles with nuts,bolts & washers including grouting on wall etc and including removing of old unserviceable item complete all as specified and directed.
Supply and fix LED secruity light fitting of capacity 60Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection with 4 KV inbuilt surge protector and cable connection from looping box to light fitting and testing and including removing of old unserviceable item complete all as specified and directed.
Supply and fixing MCCB 4 pole, 415V, 400 Amps rupturing capacity 36KA thermal magnetic based on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole, 415V, 250 Amps rupturing capacity 25 KA thermal magnetic based on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 200 Amps rupturing capacity 25 KA thermal magnetic based on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 100 Amps rupturing capacity 16 KA thermal magnetic based on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply only LED phase indication lamps RYB-01 set of three complete as existing complete all as specified and directed.
Supply only cable junction box weather & fire proof out door type installation of approved size,hinged/screwed type made of SMC plastic single door with incoming and outgoing connector/terminals suitable for 6 to 16 sqmm cable complete all as specified and directed.
Material and labour for PVC conduit heavy duty of size 20 mm dia from looping box to Street light connector, holding in MS clamp of size 25X2 mm thick at every one mtr used in each pole 04 Nos of clamps with necessary nut,bolts and washers etc and including PVC sheathed three core multistranded copper conductor cable of size 1.5 sqmm from looping box to light fitting connector and including removing of old unserviceable item complete all as specified and directed.
Material and labour for Earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM,RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directely in ground vertically ( earth pit not less than 2.25 metres deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron strip of size 25 X 4 mm from earth electrode to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate no 3 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade,GI funnel with wire mesh,including char coal, salt packed all around the earth electrode plate in layers,PCC earth pit chamber (1:3:6) type C1,RCC cover (1:2:4) type B1, including excavation,earth work in any strata and returning filling, removal of surplus soil and testing for required value including removing old item complete all as specified and directed.
Material and labour for XLPE insulated,LT armoured electric cable with aluminium standed conductor 1100 volts grade,cross-sectional area 10 sqmm ,4.0 core laid in trenches/pipes/ducts/wall/boarings with necessary cable lugs and glands,nuts,bolts and washers etc and testing including taking out old unserviceable items complete all as specified and directed.
Material and labour for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade ,cross-sectional area 6 sqmm; 2 core laid in trenches/pipes/ducts/walls with necessary cable lugs and glands, nuts, bolts and washers etc and testing including taking out old unserviceable items complete all as specified and directed.
Supply and fix GI bracket pipe of size 40 mm dia medium grade of 1.5 mtr long bent to shape hot or cold suitable for street light fitting and making the one end of GI pipe bracket suitable for fixing of any type street light fitting and shall be fixed on PCC & Steel poles/on wall surfaces and including suitable fabricate galvanised flat iron clamps of 30X6 mm thick -02 Nos suitable for fixing any place of poles with nuts,bolts & washers including grouting on wall etc and including removing of old unserviceable item complete all as specified and directed.
Supply and fix 35/40 watts LED post top lantern made in cast aluminium spigot housing with decirative opal polycarbonate diffser and IP65 protection and providing suitable fixing arrangements such as lugs,glands,nuts,bolts and washers and including removing old unserviceable item complete all as specified and directed.
Supply and fix 9 watts LED garden light Integral Decorative LED Bollard with polycarbonate diffuser and IP65 protection and providing suitable fixing arrangements such as lugs,glands,nuts,bolts and washers and including removing old unserviceable item complete all as specified and directed.
Supply and fix 9 watts LED garden light Integral Decorative LED Bollard with opal acrylic and IP65 protection and providing suitable fixing arrangements such as lugs, glands, nuts, bolts and washers and including removing old unserviceable item complete all as specified and directed.
Boaring holes horizontally under road without damaging the surface of road (minimum 1.0 Mtr bellow the road surface) with the help of GI tubing of any dia not exc 80mm dia for passing of UG cable all as specified and as directed.
Material and labour for PCC (1:4:8) type D2 using (40 mm graded stone aggregate) for making good cutting portion, mass concrete, filling of foundations etc including necessary use and waste of form work complete all as specified and directed
Material and labour for PCC (1:2:4) type B1 using (20 mm graded stone aggregate) for making good cutting portion coping of pole and filling of foundation etc including necessary use and waste of form work complete all as specified and directed.Note:- Top surface of pole coping to making smooth finishing and white washing made by the contractor cost deemed into quoted rete only.
Supply and filling in and speading unwashed river sand for cushioning and covering the under ground cables in trenches and punning to provide required cover complete all as specified in SSR Part-I and as directed.
Material and labour for earth continuity conductor or main earthing lead laid in trenches alongwith the under ground cable earth conectivity upto each pole looping box earth terminal and buried in ground or drawn in PVC conduit medium grade 15 mm dia or fixed to poles or any other indicated sitution for loop earthing etc as rquired 8 mm dia galvanised iron wire including removing old item complete all as specified and directed. (Note:- PVC conduit 15 mm dia medium grade pipe rate included in quoted rate).
Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables, pipe lines, protection pipes and foundations etc and getting out in soft loose soil complete all as specified and directed.
Excavation in trenches exceeding 1.5 mtr depth and not exc 3.0 mtr depth and not exceeding 1.5 mtr wide for foundations etc and getting out in soft loose soil complete all as specified and directed.
Returning filling in soil including spreading leveling watering and well rammimg in layer n exc 25 cm complete all as specified and directed
Removing excavated soil not exc 50 mtr ant depositing where directed at a level not exc 1.5 mtr above the starting point all as specified and directed
M & L for brick sub class 'B' 250mm x 125mm x 0.75mm and laid in trenches as in protection of UG cable complete all as specified and directed.
Material & labour for GI pipe 50 mm "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings including taking down old unserviceable items complete all as specified and directed.
Material & labour for GI pipe 40 mm "light grade" laid in trenches floors/on , pole/road for cable protection with all fittings including taking out old unserviceable items complete all as specified and directed.
Taking down unserviceiable street lights/wall mounted lights/flood lights/Post top lantrens /Guarden lights and decorative out door type lights in any wattage from 6 watt to 400 watts on any type of poles, highmast lights at any height/any places for servicing/overhauling/repair and maintenance and replacement of unserviceable spare parts/burnt out accessories such as wires,surge protector,LED drivers,LED strip,MCBs ,GI brackets,MS clamps,Timer switch,LED neon lamp,slector switches, Hole fastners etc as required for functioning items as per site requirement including testing after assembling and connecting to electric system etc complete all as specified and directed by Engr-in-Charge. Note:- (i) New spare parts will be measured and paid separately in supply only items. (ii) Street light repair work should be attended within 24 hrs as directed by Engr-in-Charge .Cost should be included in quoted rate only. (iii) Necessary T&P /tools/Transportation will be arranged by the contractor for technicians and cost should be included in quoted rate only. (iv) Complaints of urgent nature which effects security lighting system to a particular area will be attended round the clock including Sunday and Holiday. (v) The contractor should give mobile number of concern person for attending repair work to JE/Engr -in-Charge.
Supply only 3.0 core, 1.0 sqmm PVC sheathed, flexible,multistranded copper conductor cable,1100Volts grade complete all as specified and directed.
Supply only 3.0 core, 1.5 sqmm PVC sheathed, flexible,multistranded copper conductor cable,1100Volts grade complete all as specified and directed.
Supply only 3.0 core, 2.5 sqmm PVC sheathed, flexible,multistranded copper conductor cable,1100Volts grade complete all as specified and directed.
Supply only PVC conduit pipe,20 mm dia medium grade, ISI marked complete all as specified and directed.
Supply only MCB SP 6 Amps,240Volts,50Hz,10 KA,"C" series ISI marked complete all as specified and directed.
Supply only MCB SPN 32-40 Amps,240Volts,50Hz,10 KA,"C" series ISI marked complete all as specified and directed.
Supply only MCB TPN 63 Amps,415Volts,50Hz,10 KA,"C" series ISI marked complete all as specified and directed.
Supply only GI bracked 25 mm dia medium grade pipe of length 1.2 mtr including bending and necessary shape as required at site complete all as specified and directed.
Supply only GI bracked 40 mm dia medium grade pipe of length 1.2 mtr including bending and necessary shape as required at site complete all as specified and directed.
Supply only fabricated flat iron MS clamps 25X5mm & 30 mm x 6 mm as required including necessary holes,nuts,bolt and washers etc and bending, fabrication, cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat one under coat and one finishing coat of paint etc complete all as specified and directed.
Supply only cable junction box weather & fire proof out door type installation of approved size,hinged/screwed type made of SMC plastic single door with incoming and outgoing connector/terminals suitable for 6 to 16 sqmm cable complete all as specified and directed. (Make:- Hensil cat No.KF 1616B as equivalent approved make in Sintex).
Supply only LED electronic driver of capacity upto 40 watt to 60 wattage,240 Volts,50 Hz suitable for street lights as existing complete all as specified and directed.
Supply only LED electronic driver of capacity upto 70 watt to 90/100 wattage,240 Volts,50 Hz suitable for street/security lights as existing complete all as specified and directed.
Supply only LED electronic driver of capacity upto 120 watt to 150 wattage,240 Volts,50 Hz complete as existing complete all as specified and directed.
Supply only LED electronic driver of capacity upto 200 watt to 250 wattage,240 Volts,50 Hz complete as existing complete all as specified and directed.
Supply only LED electronic strip rating 20 watt to 40 watt ,240 Volts,50 Hz suitable for Post Top lanterns and wall mounting lights as existing complete all as specified and directed.
Supply only LED electronic strip rating 60 watt to 90 watt ,240 Volts,50 Hz suitable for Street lights and security lights as existing complete all as specified and directed.
Supply only LED electronic strip rating for 100 watt to 150 watt ,240 Volts,50 Hz suitable for street light and flood lights as existing complete all as specified and directed.
supply only Analogue time switch(Daily time switch) with suitable power contactor 32 Amps ML-2 type,3Phase,415 volts complete all as specified and directed.
Supply and fix LED secruity light fitting of capacity 70-75 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection with 4 KV inbuilt surge protector and cable connection from looping box to light fitting and testing and including removing of old unserviceable item complete all as specified and directed.
Supply and fix LED secruity light fitting of capacity 90 Watt LED street light fitting in aluminium PDC housing, toughened glass cover with IP65 protection with 4/5 KV inbuilt surge protector and cable connection from looping box to light fitting and testing and including removing of old unserviceable item complete all as specified and directed.
Supply and fix LED floof light light fitting of capacity 200 Watt LED, light fitting in aluminium PDC housing, toughened glass cover with IP65 protection with 4/5/10 KV inbuilt surge protector and cable connection from looping box to light fitting and testing and including removing of old unserviceable item complete all as specified and directed.
Taking down and supply and laying in trenches GI tubing 'Medium Grade' 80 mm bore, with all fittings complete all as specified and as directed (excavation of earth work shall be measured and paid separately).
Taking down and supply and laying in trenches GI tubing 'Medium Grade' 50 mm bore, with all fittings complete all as specified and as directed (excavation of earth work shall be measured and paid separately).
Taking down and supply and laying in trenches GI tubing 'Medium Grade' 40 mm bore, with all fittings complete all as specified and as directed (excavation of earth work shall be measured and paid separately).
Taking down and supply and laying in trenches GI tubing 'Medium Grade' 25 mm bore, with all fittings complete all as specified and as directed (excavation of earth work shall be measured and paid separately).
Taking down old unserviceable and supply and fixing of GM gate valves with iron wheel head, screwed both ends for iron pipes of following sizes:- (a) Gate valve of size 50mm.
(b) Gate valve of size 40mm.
(c) Gate valve of size 25mm.
Repairing of valve pit chamber after taking down cracked plaster and perforated MS cover and angle and complete with new plaster inside of valve pit chamber of any description max upto size of 1.2m x 1.2 m x 1 m and change of MS cover and angle. The steel surfaces shall be painted with two coats black bituminous paint over a coat of anti corrosive red oxide primer or all as specified and directed.
M&L for disconnecting the submersible/centrifugal/ booster pump and motor after disconnection of mechanical tyhre coupling, suction/discharge pipe line and unbolting from foundation base plate loading/ unloading the pump and motor to the veh and transportation to workshop for repair/replacement/rewinding with super enamelled copper conductor wires 22 gauge maint and incl dismantle & re-assembling the pump setting the impeller & housing for smooth running, replacement of packing gaskets etc after repair/replacement/maint transportation back from workshop to site, incl re-assembling the same, recoupling the pump with motor on base frame, checking the alignment with motor, testing & commissioning on completion and checking upto the satisfaction of Engr-in-Charge to the following capacity:- (Note:- Costs of spare parts of pump set like bearing, packing etc if required shall be deemed to be included in the quoted rate). (a) Above 2 HP upto 5 HP
(b) Upto 2 HP.
M&L for attending external water supply complain like no water in tank, pipe line breakdown/ pipe line leakage and pipe line blockage in bldgs and repair the same incl replacing of TEE, elbow, sockets, nipple & foot valve etc as per requirement in pipe line 20 to 25 mm dia incl necessary excavation earth work if required etc complete all as specified and directed. Note : (i) Complain like no water in tank to be attained within 3-4 hrs other wise necessary compensation will be charged. (ii) Cost of excavation in earth work and replacement of any unserviceable parts mentioned above required to make the breakdown/ pipe line leakage serviceable condition will be paid separately in the concerned item of schedule.
M&L for attending external water supply complain like no water in tank, pipe line breakdown/ pipe line leakage and pipe line blockage in bldgs and repair the same incl replacing of TEE, elbow, sockets, nipple & foot valve etc as per requirement in pipe line 40 to 65 mm dia incl necessary excavation earth work if required complete all as specified and directed. Note : (i) Complain like no water in tank to be attained within 3-4 hrs other wise necessary compensation will be charged. (ii) Cost of excavation in earth work and replacement of any unserviceable parts mentioned above required to make the breakdown/ pipe line leakage serviceable condition will be paid separately in the concerned item of schedule.
M&L for attending external water supply complain like no water in tank, pipe line breakdown/ pipe line leakage and pipe line blockage in bldgs and repair the same incl replacing of TEE, elbow, sockets, nipple & foot valve etc as per requirement in pipe line 80 to 250 mm dia incl necessary excavation earth work if required complete all as specified and directed. Note : (i) Complain like no water in tank to be attained within 3-4 hrs other wise necessary compensation will be charged. (ii) Cost of excavation in earth work and replacement of any unserviceable parts mentioned above required to make the breakdown/ pipe line leakage serviceable condition will be paid separately in the concerned item of schedule.
Collecting the sample of water of required quantity in bottle/kit from different point submitted duly levelled the source through Engr-in-Charge for forwarding to the test house and carrying out chemical testing of water for iron, PH value, hardness, turbidity, chloride, fluoride, arsenic test and submitted the test report in triplicate done from NABL & ISO 17025 accredited laboratory/ National Test House/ Govt approved laboratory complete all as specified and as directed.
Collecting the sample of water of required quantity in bottle/kit from different point submitted duly levelled the source through Engr-in-Charge for forwarding to the test house and carrying out bacteriological test of water sample quarterly and submitting to test report in triplicate done from NABL & ISO 17025 accredited laboratory/ National Test House/ Govt approved laboratory complete all as specified and as directed.
Boring holes 0.6 m deep in soil for under reamed piles and getting out and disposal of spoil to a distance of no exc 50m horizontally under Road without damaging the surface of road (minimum 0.6 mtr below the road surface) with the help of GI tubing of any dia not exc 200 mm for passing of UG cable/CI/GI pile all as specified and as directed.
Systematically cleaning and de-silting/de-sludging of blocked sewage/ waste pipe line 150mm dia of any description by rodding with using steel rod or split bamboo sticks thoroughly from both sides between adjacent manholes still to get clear flow of sewage line is observed, passing knots, kamti and disc of required size or pumping out liquid waste /sewage, plugging and diverting the flow to the drain if necessary and stacking the removed silt/sludge and depositing in excavated pits (required size and depth) exceeding 50m but not exceeding 100m. Top layers of excavation pit covered by layers of 150mm thick earth spreading with bleaching powder @ 200 gm per Sqm for disinfections purpose complete all as specified and directed.
Cleaning of chocked / blocked WC, bath & kitchen trap etc upto IC / gully trap of any size including bailing out water/sewage manually and removing the deposited residual sludge/debris and depositing in excavated pits (required size and depth) exceeding 50m but not exceeding 100m. Top layers of excavation pit covered by layers of 150mm thick earth spreading with bleaching powder @ 200 gm per Sqm for disinfections purpose complete all as specified and directed. ground to a distance not exceeding 50 mtr complete all as specified and directed.
De-sludging/de-silting and cleaning of existing manholes and gully traps etc of any depth including taking out sludge/ slit and other foreign materials from manholes and gully traps of any size and staking the removed silt/sludge and depositing in excavated pits (required size and depth) exceeding 50m but not exceeding 100m. Top layers of excavation pit covered by layers of 150mm thick earth spreading with bleaching powder @ 200 gm per Sqm for disinfections purpose complete all as specified and directed. ground to a distance not exceeding 50 mtr complete all as specified and directed.
Opening cover, cleaning and de-sludging, excreta, night soil etc of existing septic tank, soak well and sewage sump completely of solid/liquid sludge by pumping or manually from inside the septic tank, soak well and sewage sump and removal of sludge and depositing in excavated pits (required size and depth) exceeding 50m but not exceeding 100m. Top layers of excavation pit covered by layers of 150mm depth earth spreading with bleaching powder @ 200 gm per Sqm for disinfections purpose complete all as specified and directed. (Note for item No. 277 to 280 :- Excavation of trenches, disposal of surplus soil and bleaching powder is deemed to be included in the quoted unit rates however quantity of sludge portion only will be measured and paid. )
Excavation of liquid soil/mud for di-silting/cleaning of area drainage not exceeding 1.5m deep in soft /loose soil and removing materials exceeding 50m but not exceeding 100m and depositing, spreading and levelling complete all as specified and directed.
Supply and filling loose brick aggregate of gauge 80 to 100mm in soak well / soakage pit after opening of cover slab and placing the same in position after filling of aggregate including taking out old unserviceable brick aggregate from soak well/soakage pit and removed from site including cleaning of soak well complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete complete all as specified and directed.
M&L for PCC (1:2:4) type B0 (using 12.5mm graded crushed stone aggregate) as in copping of manholes / drains, benching and channel of manhole / drains, and also for bed blocks for embeddings MS rungs of manhole / septic tank including necessary form work complete all as specified and directed.
M&L for precast reinforced cement concrete (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in cover slab of drain/manhole set in cement mortar (1:6) complete all as specified and directed. (NOTE: Cost of form work is deemed to be inclusive of unit rate quoted by the contractor & reinforcement shall be measured & paid Separately.)
M&L for cutting holes into or through brick walls built in cement mortar and making good in cement mortar (1:3) or concrete (1:2:4) type B1 as required for superficial area exceeding 100 sqcm & not exceeding 150 sqcm complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick works of internal surfaces, finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:6) on other than fair faces of brick works of surfaces finished the surface even and smooth without using extra cement complete all as specified and directed.
M&L for PCC (1:4:8) type D2 (using 40mm graded crushed stone aggregate) as in concrete bed to drain pipe 150mm bore including packing under and haunching against the side of pipe after they are laid and tested after and including demolition of existing concrete bed complete all as specified and directed.
M&L for 150 mm bore PVC(SWR) Pipe in trenches and jointed in cement mortar (1:1) after and including demolition and breaking up the unserviceable drain pipe of any description complete all as specified and directed.
S&F 32mm bore flexible pipe of PVC in waste pipe for WHB or sink including connection as in repairs complete all as specified and directed.
S&F in repairs 100 mm dia cast Iron bends (any radius) diminishing piece or tapers (larger bore measured) fixed with oval access door complete all as specified and directed.
S&F in repairs 100mm dia CI branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access door complete all as specified and directed.
S&F in repairs 100 mm dia CI branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches with oval access doors complete all as specified and directed.
S&F in repairs 100 mm cast iron cowls complete all as specified and directed.
S&F 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls as in floor after dismantling of old PVC/AC pipe complete all as specified and directed.
S&F 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls as in floor after dismantling of old PVC/AC pipe complete all as specified and directed.
S&F in repairs 110 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F in repairs 75 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F in repairs 110mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
S&F in repairs 75 mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
S&F in repairs 125/110mm dia PVC (SWR) gully trap , settings and jointing with solvent cement complete all as specified and directed.
S&F in repairs 100mm dia grating doom PTMT (minimum weight 40gms) complete all as specified and directed.
S&F 100 mm bore / inner dia double wall corrugated HDPE pipes (SN8) in any length , laid in trenches or in floors all as specified and directed.
S&F 150 mm bore/Inner Dia double wall corrugated HDPE pipes (SN8) in any length , laid in trenches or in floors all as specified and directed.
S&F 200 mm bore/Inner Dia double wall corrugated HDPE pipes (SN8) in any length , laid in trenches or in floors all as specified and directed.
S&F 250 mm bore/Inner Dia double wall corrugated HDPE pipes (SN8) in any length , laid in trenches or in floors all as specified and directed.
S&F 300 mm bore/Inner Dia double wall corrugated HDPE pipes (SN8) in any length , laid in trenches or in floors all as specified and directed.
Providing water proofing treatment to RCC sunken slab as specified and directed as under (a) Demolished the exisiting damaged concrete from sunken portion carefully upto RCC slab including taking out of water closet and traps etc ( depth approx 400mm) (b) Cleaning the existing RCC sunken slab and vertical wall/RCC beam as per direction (c) 15 mm thick plaster over the flat & vertical surface in CM ( 1:4) mixed with WPC as per manufacturer's instruction (d) Applying two coats of elastomeric acrylic water proof coating using rooler, each coat of elastomeric acrylic compound required 6-8 hrs to dry, 2nd coat shall be applied on fetting the first coat complete dry consumption of materials shall be as per manufacturer's instructions. (e) Filling the sunken portion with PCC ( 1:5:10) type E2 with using 40 mm graded stone aggregate. (f) After complete treatment of RCC sunken portion same shall be tested with 72 hrs ponding test, to observe the leakage and seepage from RCC portion. Note : Payment shall be allowed after getting satisfactory test report of ponding test.
M&L for PCC (1:2:4) type B-0 (using 12.5mm graded stone aggregate), 25mm thick as in sub base to the flooring complete all as specified and as directed by Engr-in-Charge.
S&F in repairs for LLDPE Septic tanks, On site LLDPE septic tank designed to carry sewage and sullage water, excavation in any type of soil, PCC 1:4:8 below foundation, Vent shaft, connection etc, complete for fixing in any type of including connection etc vent shaft complete upflow filter including media. etc, complete for 10 users.
Soakage wells excavation, in any type of soil, foundation in PCC 1:3:6, walls of honey combed masonry with top ring of M25 concrete including intercepting chamber and screen chamber made of Brick masonary in CM 1:4, RCC cover slab in M25/ SFRC cover, interconnecting pipes of RCC/DWC complete filled with brick bats of size 1.20 Mtr dia x 1.50 mtr deep.
Removing plant including roots by dismantling of brick work/PCC/RCC including necessary scaffolding any type in any location/position i.e. roof, parapet wall near pipes etc and applying concentrated hydrochloric or sulphuric acid after removing roots for preventing the regrowth and making good of disturbed portion using PCC (1:2:4) type B0 & 10mm thick plaster in cement mortar (1:3) size of disturbed portion 150mm X150mmX200mm complete all as specified and directed.
S&F in repairs Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe)
Taking out split type air conditioners indoor and outdoor units complete for repair/ servicing and overhauling of capacity 1.5/2.0 TR of any make/ type after disconnecting refrigerant pipes, drain pipe and electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda/ cleaning chemical agents, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower etc and also incl carrying out servicing, overhauling and connecting of refrigerant pipe, drain pipe and charging of refrigerant gas and testing incl fixing back in its original location complete all as specified and directed. Note : (i) Spares will be measured and paid separately as supply only items. (ii) Refrigerant gas wil be measured and paid separately only.
Supply & Fix sealed compressor of split type air conditioner of 1.5 TR capacity incl initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. (Make : Voltas/Hitachi/Tecumseh/LG/Blue Star).
Supply & Fix MS wall bracket suitable for fixing of out door unit of split type Air Conditioner with necessary nuts, bolts & washers and removing old unserviceable items and making good disturbed surfaces ot match with the existing complete all as specified and directed. (Make : As per sample).
Leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/ arresting leakage by cutting, soldering, flaring work with nut, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in split type air conditioner upto 1.5 TR/ 2 TR capacity and testing complete all as specified and directed. Note : small copper parts required for jointing is deemed to be included but Refrigerant will be measured and paid separately.
Supply charging refrigerant gas (R-32/R134a) suitable for split/window AC/Refrigerator after full vacume of the system complete all as specified and directed. (Make : Mafron or equivalent makes as approved by the GE).
Supply & Fix relay assembly suitable for split type air conditioner 1.5/2.0 TR capacity complete all as specified and directed. (Make : As per sample).
Supply & Fix fan motor with blade suitable out door unit split type air conditioner up to 2 TR capacity complete all as specified and directed. (Make : As per sample).
Supply & Fix blower fan motor with blade for out door unit including capacitor, single phase, 230V 50Hz for split type air conditioner up to 2 TR capacity complete all as specified and directed. (Make : Usha/AUE/Siemens/Keltron or equivalent any make with ISI marked).
Supply & fix starting capacitor 80 to 100 mfd for split type air conditioner complete all as specified and directed. (Make : Concap/Keltron/Asian/Tesla/Sarda/Siemens/ Tibcon).
Supply & fix running capacitor 36 - 60 mfd for split type air conditioner complete all as specified and directed. (Make : Concap/Keltron/Asian/Tesla/Sarda/Siemens/ Tibcon).
Taking down remote control unit PCB board from indoor unit of split type AC of 1.5/2.0 TR capacity and checking the electronic circuit and rectifying the defects by replacing the defective components with new ones and testing complete all as specified and directed.
Taking down remote control unit PCB board from indoor/outdoor unit of split type dual inverter AC of 1.5/2.0 TR capacity and checking the electronic circuit and rectifying the defects by replacing the defective components with new ones and testing complete all as specified and directed. (Make : LG).
Removing the old unserviceable swing motor of any type and supply and fix new swing motor of 1.5/2.0 TR capacity split type Acs complete all as specified and directed. (Make : As per sample).
Removing the old acoustic padding and supply and fix new acoustic ('U' form) padding with all packing material for refrigerant tubing form outdoor unit to indoor unit after dismantling copper tube and re fix again all as specified and directed.
Taking out the old unserviceable PVC drain pipe from wall to ground at any height and including its fittings and supply and fix new PVC pipe 15 mm dia, ISI marked including bends, Tees, elbows, sockets, saddles etc for condensed water complete all as specified and all as directed.
Supply & fixing of copper tube 1/2" dia complete all specified and directed.
Supply & fixing of copper tube 1/4" dia complete all specified and directed.
Supply & fixing of copper tube 5/8" dia complete all specified and directed.
Dismantling of the window/ split type air conditioner of capacity complete set 1.5/2.0 TR form the existing position and shifting the same to the new altered location, complete indoor and outdoor units, refrigerant tubing, MS stand, stablizer and cable etc and testing complete all as specified and directed.
Taking out window type air conditioner for servicing and overhauling of capacity 1.5/2.0 TR of any make/ type after disconnecting of electric connection, removing dust by using blower and cleaning the condenser coils and components by using water and caustic soda, checking and replacing the spares like relay, capacitors, thermostat, fan motor, blades & blower and also including carrying out servicing, overhauling and charging of refrigerant gas and testing including fixing back in its original location complete all as specified and directed. Note : (i) Spare swill be measured and paid separately as supply only items. (ii) Refrigerant gas will be measured and paid separately.
Replacing the corroded outer casing with base tray sheet of the window type air conditioner of capacity upto 2 TR of any type/ make and supply and fix outer casing with bse sheet made out of GI sheet suitable to window type air conditioner of capacity upto 2 TR complete all as specified and directed. (Make : As per sample).
Leak testing the complete gas circulating system with dry nitrogen & evacuate and rectifying/ arresting leakage by cutting, soldering, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in window type air conditioner upto 2 TR capacity and testing complete all as specified and directed.
Supply & fix sealed compressor of window type air conditioner of 1.5 TR capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. (Make : LG/Voltas/Hitachi/Tecumseh/Kirloskar/LG/Blue Star).
Supply & fix sealed compressor of window type air conditioner of 2.0 TR capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. (Make : LG/Voltas/Hitachi/Tecumseh/Kirloskar/LG/Blue Star).
Supply & fix starting capacitor 80 to 100, 100 to 120 mfd for window type air conditioner complete all as specified and directed. (Make : Concap/Keltron/Asian/ Tesla/Sarda/Siemens/Tibcon).
Supply & fix running capacitor 40, 50, 60 mfd for window type air conditioner complete all as specified and directed. (Make : Concap/Keltron/Asian/Tesla/Sarda/Siemens/ Tibcon).
Supply & fix blower fan motor with blade including capacitor, single phase, 230V, 50Hz for window type air conditioner upto 2 TR capacity complete all as specified and directed. (Make : Usha/AUE/Siemens/Keltron or equivalent any make with ISI marked).
Supply & fix fan motor with blade suitable for window type air conditioner upto 2 TR capacity complete all as specified and directed. (Make : As per sample).
Supply & fix relay contactor suitable for existing window type air conditioner upto 1.5/2 Ton capacity complete all as specified and directed. (Make : LG/Samsung/Carrier/Blue Star/hitachi).
Taking out Refrigerator for servicing and overhauling from 165 ltr to 352 ltr capacity (single door/ double door type) of any make/type afte disconnecting of electric connection and cleaning all the components, checking and replacing the spares like relay, capacitors, thermostat, fused bulb and also including carrying out servicing, oiling, greasing of refrigerant gas and testing complete all as specified and directed. Note : (i) Spares will be measured and paid separately as supply only. (ii) Refrigerant gas will be measured and paid separately as supply only.
Leak testing the complete gas circulating system with dry nitrogen & evacuate and redtifying/arresting leakage by cutting, soldering, jointing of refrigerant tubing and charging of refrigerant gas to the required pressure in Refrigerator upto 352 ltr capacity and testing complete all as specified and directed.
Supply & fix sealed compressor of Refrigerator upto 185 ltr capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. (Make : Voltas/Kelvinator/Tecumseh/Kirloskar/Usha/Godrej).
Supply & fix sealed compressor of Refrigerator 210 to 352 ltr capacity including initial filling of refrigerant gas to the required pressure and testing and also removing old unserviceable compressor complete all as specified and directed. (Make : LG/Voltas/Kelvinator/Tecumseh/Kirloskar/Usha/Godrej/Videocon/Samsung).
Supply & fix relay assembly suitable for refrigerators of any type/ capacity 165 to 352 litres complete all as specified and directed.
Supply & fix condensor coil suitable for refrigerators of any type/ capacity 165 to 352 litres complete all as specified and directed.
Supply & fix cooling coil suitable for refrigerators of any type/ capacity 165 to 352 litres complete all as specified and directed.
Supply & fix capacitor 6 to 10 mfd complete all as specified and directed. (Make : Asian/KEL/Epcos/Tipcon).
Supply & fix thermostat switch for refrigerators of any capacity/ any type/ make complete all as specified and directed. (Make : INDOFOSS/RANUTRAL/Annapurna).
Supply & fix heating element 20 to 40 watt for refrigerators of any capacity/ any type/ make complete all as specified and directed. (Make : INDOFOSS/RANUTRAL/Annapurna).
Removing old unserviceable capilary copper tube of size 0.031" (inch) and supply and fix new capilary copper tube suitable for existing type/make/size complete all as specified and directed.
Supply & fix anti bacterial gasket set including magnet if required for refrigerator doors of any capacity/type/ any make (as per sample) complete.
M & L for water, dust and direct heat proof cover of split AC outdoor unit of any description as per direction of Engr-in-Charge.
Taking down voltage stabilizer any make of capacity upto 5 KVA Single Phase by replacing unserviceable parts and refixing the same in working condition on existing location.
MERCANTILE AGENCY (BID ID -3154639)
SENCO (BID ID -3153504)
ROY CONSTRUCTION (BID ID -3154746)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .