Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 LAccepted-AOC 84 A VIJAY NAGAR COLONY LALGHATI PO NAYAPURA BHOPAL 462032 | 462032 | L1 | Accepted-AOC LOWEST BIDDER FOR THE WORK | |
| 2 | L2₹16.0 L+₹1.1 L (7.46%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹18.6 L+₹3.8 L (25.3%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹18.9 L+₹4.0 L (27.0%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN THE LOWEST BIDDER |
Tender Value
₹21.4 L
EMD Value
₹42,800
Closing Date
23 Dec 2019, 6:00 pmClosed
CWE BHOPAL
HQ CWE BHOPAL, SI LINES, BHOPAL, PIN-462001
SPECIAL REPAIR FOR REPLACEMENT OF HT OVERHEAD LINES BY UNDERGROUND HT CABLE AT MARRIED AND SINGLE OFFICERS ACCN AREA OLD SI LINES BHOPAL
2019_MES_270296_1
83403
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
BHOPAL
AS PER NIT CONDITIONS
4 documents required · 4 mandatory
₹500
GE BHOPAL
₹42,800
Yes
23 Jan 2020
29 Nov 2019
30 Dec 2019
29 Nov 2019
23 Dec 2019
13 Dec 2019
Amount
Supply, laying and testing cable XLPE insulated, screened, PVC bedded,galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 120 sqmm 3 core.
Supply, jointing and testing outdoor type cold shrinkable end termination cable joint including all material and accessories suitable for 3 core x 120-185 Sqmm earthed XLPE cable of 11000 Volts grade all as per manufacturer’s recommendations, complete all as specified and directed.
S&F GI Pipe light grade on wall/ floor/ Trench for cable protection with fixing arrangement size 100 mm dia.
S&F Pre-cast RCC post HT cable route indicator made up of RCC (1:1.5:3) of overall size 100mm x 100mm x 750mm (H) with 4 nos 8mm dia TMT Bar on Vertical and 8mm TMT stirrups at 150 c/c including binding wire and emboshing "MES HT CABLE" on all four side and fixed at cable trence during returning filling of soil keeping 400mm above ground, complete all as specified and directed.
M&L for PCC (1:3:6) type C-2 (Using 40 mm graded crushed stone aggregate) for foundation of pole/ Paving/ drain etc, complete all as specified and directed.
Dismantling cross arms of MS Channel or angle sections etc from HT OH line, complete all as specified and directed
Dismantling insulators of HT OH line any type, any size, complete all as specified and directed
Dismantling earth wire, complete all as specified and directed
Dismantling ACSR conductor, complete all as specified and directed
Dismantling stay assembly, complete all as specified and directed.
Dismantling Concrete poles/ struts, any size, complete all as specified and directed.
Dismantling Steel poles/ struts, any size, complete all as specified and directed.
Excavation in trenches in hard rock soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc and getting out including trimming sides and forming bottom surface, complete all as specified and directed at site.
Excavation in trenches in any type of soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cables, RCC poles/stays and struts etc and getting out including trimming sides and forming bottom surface, complete all as specified and directed at site.
Returning, filling in including spreading, levelling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested,poles, stays , struts have been erected and tested, complete all as specified and directed at site
Removing excavated surplus soil (Soft/hard soil) obtained from excavation to a distance not exceeding 50 mtr and deposting where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
M&L for sand filling in-trenches with clean dry sand unwashed including gently pruning around cables, complete all as specified & directed. Note: Punned thickness shall be measured & paid.
S&L reinforced precast concrete cable cover, class HV type -1, flat, size 300mmX180mmX 40mm laying flate for cable protection, complete all as specified and directed.
M&L for cutting PCC/floor/road and taking out cable and making good, including material as per existing after laying of pipe for cable protection, complete all as specified and directed. Note: Size of trench shall not be more than 0.30 x 0.30 cm.
M&L for earthing complete with galvanised steel earth plate electrode size 600x600x6.3mm thick burried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised iron strip 32X6 mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion. Notes: 1. The unit rate includes for protection pipe and GI strip dia from top of earth plate upto 5.00 meter above ground level.
M&L for machine pressed precast concrete interlocking paver block any shape and size fonfirming to IS-15658-2006 of 60 mm thickness, M-35 grade, with grey cement and pigment, complete all as specified and directed.
Note for all items: All items shall be executed as specified and directed by Engr-in-charge.
M/S RAKESH TRADERS
ELITE WORKS
Oasis Infosystem Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .