Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹69.2 LAccepted-AOC 138 KASARA STREET 3RD LANE DARUKHANA MUMBAI MAHARASHTRA 400010 | MUMBAI SUBURBAN | MAHARASHTRA | 400010 | ₹69.2 L | L1 | Accepted-AOC L1 Bidder |
| 2 | L1₹5.2 CrAccepted-AOC G 69 MIDC INDUSTRIAL AREA BOISAR TARAPUR PALGHAR MAHARASHTRA 401506 PALGHAR MUMBAI MAHARASHTRA 400072 | PALGHAR | MAHARASHTRA | 401506 | ₹5.2 Cr | L1 | Accepted-AOC L1 Bidder |
| 3 | Rejected-Technical 25 390 392 SHANKAR MENSION GR FLOOR S V P ROAD NEAR HARKISHANDAS HOSPITAL MUMBAI MAHARASHTRA 400004 | MUMBAI | MAHARASHTRA | 400004 | - | - | Rejected-Technical Techno-Commercially Not Acceptable. |
| 4 | Rejected-Technical 102 104 2ND FLOOR PRAVIN HOUSE 1ST PATHAN STREET 4TH KUMBHARWADA NEAR MOTI TALKIES MUMBAI MAHARASHTRA 400004 | MUMBAI | MAHARASHTRA | 400004 | - | - | Rejected-Technical Techno-Commercially Not Acceptable. |
| 5 | Rejected-Technical ROOM NO 9 105 RATNA SADAN 2ND PATHAN STREET 5TH KUMBHARWADA MUMBAI MAHARASHTRA 400004 | MUMBAI | MAHARASHTRA | 400004 | - | - | Rejected-Technical Techno-Commercially Not Acceptable. |
| Sl No | Description | Qty | Unit | MUKAT TANKS AND VESSELS PVT. LTD. | RATNAMANI METALS AND TUBES LIMITED | Lalit Pipes & Pipes Pvt, Ltd. |
|---|---|---|---|---|---|---|
| 1.00SUPPLY OF PIPES-CARBON STEEL (WELDED) TO ASTM STDS | ||||||
| 1.01 | PIPE,EFW,CS (H2 SER.), B36.10M, BW ENDS,SCH 30, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.32, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004 | 34 | Mtrs | 8,90,766 ₹8,90,766 | 9,62,200 ₹9,62,200 | 7,48,170 ₹7,48,170 Lowest |
| 1.02 | PIPE,EFW,CS (H2 SER.), B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.32, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004 | 12 | Mtrs | 1,85,040 ₹1,85,040 Lowest | 2,53,008 ₹2,53,008 | 2,12,064 ₹2,12,064 |
| 1.03 | PIPE,EFW,CS (H2 SER.), B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.32, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004 | 23 | Mtrs | 4,00,407 ₹4,00,407 | 5,18,443 ₹5,18,443 | 3,75,682 ₹3,75,682 Lowest |
| 1.04 | PIPE,EFW,CS (H2 SER.), B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.32, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004 | 17 | Mtrs | 3,29,783 ₹3,29,783 | 4,27,193 ₹4,27,193 | 3,22,014 ₹3,22,014 Lowest |
| 1.05 | PIPE,EFW,CS (H2 SER.), B36.10M, BW ENDS,SCH NON-STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.32, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004 | 20 | Mtrs | 7,69,600 ₹7,69,600 | 9,41,280 ₹9,41,280 | 6,56,120 ₹6,56,120 Lowest |
| 1.06 | PIPE,EFW,CS (H2 SER.), B36.10M, BW ENDS,SCH NON-STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.32, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004 | 24 | Mtrs | 9,91,200 ₹9,91,200 | 12,12,648 ₹12,12,648 | 8,24,472 ₹8,24,472 Lowest |
| 1.07 | PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001 | 953 | Mtrs | 70,69,354 ₹70,69,354 Lowest | 75,99,222 ₹75,99,222 | 73,54,301 ₹73,54,301 |
| 1.08 | PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001 | 57 | Mtrs | 5,70,000 ₹5,70,000 Lowest | 7,55,250 ₹7,55,250 | 5,81,286 ₹5,81,286 |
| 1.09 | PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001 | 8 | Mtrs | 98,448 ₹98,448 Lowest | 4,21,720 ₹4,21,720 | 1,51,160 ₹1,51,160 |
Tender Value
Refer Docs
Closing Date
15 Jul 2024, 3:00 pmClosed
Mr. Nilesh Sathe
tkUIPL-Mumbai
SUPPLY OF PIPES-CS (WELDED) FOR P25 PROJECT AT IOCL PANIPAT REFINERY
2024_REFHQ_178450_1
6745-PPM-000-CA-PI91
Limited
Mechanical - Piping, materials, flanges, valves, seals
Supply
120 days
IOCL PANIPAT REFINERY
Please refer Tender documents
6 documents required · 6 mandatory
Exempted
29 Aug 2025
26 Jun 2024
16 Jul 2024
26 Jun 2024
15 Jul 2024
8 Jul 2024
SUPPLY OF PIPES-CARBON STEEL (WELDED) TO ASTM STDS
PIPE,EFW,CS (H2 SER.), B36.10M, BW ENDS,SCH 30, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.32, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
PIPE,EFW,CS (H2 SER.), B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.32, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
PIPE,EFW,CS (H2 SER.), B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.32, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
PIPE,EFW,CS (H2 SER.), B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.32, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
PIPE,EFW,CS (H2 SER.), B36.10M, BW ENDS,SCH NON-STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.32, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
PIPE,EFW,CS (H2 SER.), B36.10M, BW ENDS,SCH NON-STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.32, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, 200 BHN MAX, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, 200 BHN MAX, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, 200 BHN MAX, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, 200 BHN MAX, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, 200 BHN MAX, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, 200 BHN MAX, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, 200 BHN MAX, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, 200 BHN MAX, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, 200 BHN MAX, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH 40, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH NON-STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, 200 BHN MAX, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS, B36.10M, BW ENDS,SCH NON-STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, 200 BHN MAX, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH NON-STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH NON-STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH NON-STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH NON-STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE), B36.10M, BW ENDS,SCH NON-STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, 200 MAX BHN, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
PIPE,EFW,CS (NACE+H2), B36.10M, BW ENDS,SCH 40, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.C65 CL.32, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005, 3.ADDITIONAL REQUIREMENTS FOR H2 SERVICE, ACC. TO DOC. 6745-PIP-000-EC-0004
PIPE,EFW,CS (IBR), B36.10M, BW ENDS,SCH NON-STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.22, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIA REQUIRED
PIPE,EFW,CS (IBR), B36.10M, BW ENDS,SCH 30, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIA REQUIRED
PIPE,EFW,CS (IBR), B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIA REQUIRED
PIPE,EFW,CS (IBR), B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIA REQUIRED
PIPE,EFW,CS (IBR), B36.10M, BW ENDS,SCH STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIA REQUIRED
PIPE,EFW,CS (IBR), B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIA REQUIRED
PIPE,EFW,CS (IBR), B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIA REQUIRED
PIPE,EFW,CS (IBR), B36.10M, BW ENDS,SCH XS, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIA REQUIRED
PIPE,EFW,CS (IBR), B36.10M, BW ENDS,SCH NON-STD, EFW, 100% RADIOGRAPHY, WELD FACTOR E = 1.00, PIPE A672 Gr.B60 CL.12, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.IBR CERTIFICATE IN FORM IIIA REQUIRED
MUKAT TANKS AND VESSELS PVT. LTD.
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .