Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹25.6 LAccepted-AOC 1001 SHIVALIK ABAISE 100 FEET ROAD OPP ANANDNAGAR APARTMENT PRAHALADNAGAR AHMEDABAD AHMEDABAD GUJARAT 380015 | AHMADABAD | GUJARAT | 380015 | ₹25.6 L | 1 | Accepted-AOC L-1 Bidder |
| 2 | 2₹26.9 L+₹1.3 L (5.01%)Rejected-Finance NO 501 SACAYA TECHNOLOGIES PVT LTD 7TH CROSS 7TH MAIN JP NAGAR BENGALURU KARNATAKA 560078 | BENGALURU URBAN | KARNATAKA | 560078 | ₹26.9 L+₹1.3 L (5.01%) | 2 | Rejected-Finance Not being L-1 Bidder |
| 3 | 3₹27.3 L+₹1.7 L (6.60%)Rejected-Finance | ₹27.3 L+₹1.7 L (6.60%) | 3 | Rejected-Finance Not being L-1 Bidder |
| 4 | 4₹28.8 L+₹3.2 L (12.4%)Rejected-Finance GLYPTIC RAIPUR P O BHITA BURDWAN 713102 | BURDWAN | PURBA BARDHAMAN | WEST BENGAL | 713102 | ₹28.8 L+₹3.2 L (12.4%) | 4 | Rejected-Finance Not being L-1 Bidder |
| 5 | 5₹29.8 L+₹4.2 L (16.3%)Rejected-Finance | ₹29.8 L+₹4.2 L (16.3%) | 5 | Rejected-Finance Not being L-1 Bidder |
Tender Value
₹30.5 L
Closing Date
19 Jan 2021, 3:00 pmClosed
JGM(E-E)-II, AAI,AMED,CIA
JGM(E-E)-II, AAI,AMED, FF,Operational Offices, Chennai Airport-600016.
Replacement of Beam detector systems, Smoke detectors, Fire Alarm Panels at T1 and T4 at Chennai International Airport.SH- Replacement of VESDA system with Beam Detector.
2020_AAI_65728_1
2020/AAI/CIA/AMED-5/CPP-2/BEAM
Open Tender
Electrical Works
Item Rate
90 days
Chennai International Airport
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,120
Exempted
29 Jul 2021
31 Dec 2020
20 Jan 2021
31 Dec 2020
19 Jan 2021
31 Dec 2020
31 Dec 2020 - 11 Jan 2021
Amount
Supplying, Installing, Testing and Commissioning of UL / EN/BIS listed (Latest Version) Addressable motorised auto align Beam detector for Minimum of 100mtrs range with transmitter, receiver, multi mounting arrangement & control panel etc as per specification,complete as required. Approved Make Apollo/Edwards/Siemens/Bosch/Notifire/System Sensor/Morley IAS
Providing, installation, testing & commissioning of UL / EN /BIS listed (Latest Version) Monitor Module as per specifications (Model : SIGA-CTI of Edwards Make)
Providing, installation, testing & commissioning of UL / EN /BIS listed Fault Isolator as per specifications(Model : SIGA-CTI of Edwards Make)
Supply & fixing of Surge Protector Module having operating voltage of 120V AC to 240V AC, single phase continuous operating current, operating frequency of 47-63Hz as required. Approved make: Finder/L&T/Legrand/DEHN
Providing SMPS suitable for Beam Detector with transmitter, receiver & control panel etc.as per specification,complete as required. Approved Make: Microtek/power-one/Socomec/Green/Numeric/Schneider/Powerware/Emerson/DBpower/APC
Providing, installation, testing & commissioning of 1 Loop Card having Capacity of Minimum 125 devices with necessary booster power supply in existing Fire Panel complete as required. Approved Make : Edwards
Providing, installation, testing & commissioning of all Detectors , Modules, Programming & Testing with Fire Alarm Panel complete as required..
Providing, installation, testing & commissioning of AUTOCAD software in existing PC ,including drawing designing with the existing building complete as required.
Supply, installation, testing and commissioning of UL / EN /BIS listed loop powered addressable Hooter-cum- strobe with adjustable sound level in the range of min. 90 db to Max. 120 db at 1M distance complete with termination etc. as required and as per enclosed specification. Approved Make Apollo/Edwards(UTC)/Siemens/Bosch/Notifire/System Sensor/Morley IAS/Group 4/Minimax
Providing, installation, testing & commissioning of UL / EN/BIS listed output Module as per specifications. Approved Make: Edwards
Supply & laying of PVC insulated FRLS 2C x 1.5sq.mm copper conductor armoured control cabling for Fire detection & alarm devices as required. Approved Make: CMI/KEI/Bonton/Polycab/BatraHenley/RR Kable/Wrexham/Fusion Polimer
Wiring for circuit/ submain wiring alongwith earth wire with 2x1.5 sq.mm + 1x1.5 sq.mm of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required etc.,
Supply and installation of S.S Clamp including SS support rod of minimum 1 mtr length complete as required etc for Beam detector and beam reflector as per site requirement
Sacaya Technologies Pvt Ltd
SALIMAX SYSTEMS AND CONTROLS ENGG
GLYPTIC
Intek Security Systems Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .