Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹19.9 L+₹98,144 (5.18%)Rejected-Finance | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹21.3 L+₹2.4 L (12.5%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹21.6 L+₹2.6 L (14.0%)Rejected-Finance | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹21.9 L+₹2.9 L (15.5%)Rejected-Finance | L5 | Rejected-Finance Being L5 |
Tender Value
₹17.8 L
EMD Value
₹35,560
Closing Date
28 Feb 2022, 6:00 pmClosed
CWE Hisar
HQ CWE Hisar Hisar Mil Stn Hisar
REPAIR/REPLACEMENT OF HT/LT OH HT/LT U/G CABLES LT PANELS TRANSORMER INCL ALLIED WORKS AT EBS AND BHOJRAJ AND (ASCON NODE) CHHANIBARI UNDER GE (W) HISAR AT HISAR MIL STATION
2022_MES_503049_2
CWE/HSR-30 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Hisar Military Station
As per tender documents
9 documents required · 9 mandatory
₹500
GE (West) Hisar
₹35,560
17 Mar 2022
16 Feb 2022
2 Mar 2022
16 Feb 2022
28 Feb 2022
23 Feb 2022
Amount
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cable etc. and for foundation of poles, stays etc. n exc 10 sqm on plan and n exc 1.5 in depth and getting out complete all as specified.
Description all as per Serial item No 1 above but Add to item 1 for each additional 1.5m or part thereof in depth beyond the first 1.5 mtr complete all as specified and directed.
Returning filling with earth obtained from excavation including spreading, watering & consolidation in layers not exceeding 15 cms thick, complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m & depositing at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Material & labour for Sand filling in trenches with clean dry fine sand unwashed including gently punning around cables complete all as specified and directed.
Material & labour for bricks covering to under ground electric cable using sub class 'B' bricks laid dry, flat, perpendicular to the direction of the cable complete all as specified and directed.
Supply errecting & fixing in true vertical position pre stressed concrete pole conforming to IS-1678 of 9 mtr long,102 mm x 172 mm at top and 102 mm x 279 mm at bottom,class 10 complete as specified & directed (Note : Earth work & PCC shall be measured and paid separately)
Material & labour for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate . in mass concrete and filling complete for foundation of pad of pole all as specified & directed.
Material & labour for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate . in mass concrete and filling complete for foundation of Panel & Transformer yeard, pole/stay/ of pole all as specified & directed by Enge-in- Charge
Material & labour for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate in coping for replacement of new pole and breaking old existing coping and like including weather slightly rounded or chamfered angles and throaty and necessary form work complete for pole ,all as specified and directed .
Material & labour for GI HT Stay assembly set comprising of 20 mm dia 400 mm iron stay bow, 2150 mm long stay rod 16mm dia stay plate 300 x 300 x 8 mm thick, GI stay wire 7/8 SWG of required length and loop insulator complete with all aceessories as shown in electric plate no 1 of MES scheledule Part I complete. Note :- Earth work, PCC,stay clamps, stay wire will be measured separately.
Material & labour for GI LT Stay assembly set comprising of 16 mm dia stay GS rod with overall length of 1800 mm and finished bow anchor should have overall length 995 mm and plate size 200 x 200 x 6 mm thick, GI stay wire 7/12 SWG of required length and loop insulator complete with all aceessories as shown in electric plate no 1 of MES scheledule Part I complete. Note :- Earth work, PCC, stay wire and clamp will be measured separately.
Material & labour for galvanized stay stranded wire of size 7/4 mm and fixing to stay assembly complete all as shown in electrical plate No 1 of SSR-2009 (Part-I) complete all as specified and directed.
Material & labour for galvanized stay stranded wire of size 7/2.5 mm and fixing to stay assembly complete all as shown in electrical plate No 1 of SSR-2009 (Part-I) complete all as specified and directed.
Supply and fixing Aluminium conductor steel reinforced (ACSR) of any size for HT/LT OH lines on poles including stringing ,binding with aluminium wire 14 SWG or aluminium tape incl jumpers complete connecting of disconnected cable, service cable and street light connection complete all as specified and directed.
Material & labour for cradles, hexagonal/Rectangular, fabricated with galvanized steel wire 4 mm dia including stretching, sagging and jointing in position as a continuous earth wire on pole and for guarding complete all as specified and directed.
Material & labour in replacement of Cross Arms bracings supports, clamps, eye hook and back plates fabricated from structural steel sections including pole clamps stay clamps, D clamps nuts, bolts , washers,welding, bending cold or hot drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of aluminium paint complete all as specified and directed.
Supply installation, connecting and testing gang operated air break switch, mounted on insulators HT 11KV 200 Amps rating , triple pole,twelve insulator suitable for horizontal mounting fixed and spring loaded revolving tinned brass/copper copper contacts, galvanized steel base frame, 32 mm bore med grade pipe Galvanized operating rod(Medium Grade), operating handle, locking arrangement complete including taking down the existing gang operated air break switch complete all as specified and directed. (i) Cross arms of 2 pole/4 pole structure reqd for installation of GO switch,if reqd additional, shall be measured and paid seperately. (ii) Scope of wk shall include ACSR conductors PVC sleeves, PG clamps and thimbles reqd for jumpers/connections to OH lines of 2 poles/ 4 poles structures and outgoings feeders.
Material & labour for replacement of lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo Amps 11000 volts complete including taking down the existing lightening arrestor complete all as specified and directed.
Supply and installation replacement of drop out fuse assembly 11KV,25 Amps rating complete expulsion fuse element mounted on four/two pole structures all as specified and directed.
Supply and fixing in replacement of insulators pin type porcelain, vitreous ,white or brown or green insulator of size 150 mm height, 150 mm dia suitable for 11 kV grade including one galvanized mild steel spindle, two GI washers and one nut including removing the existing unserviceable one complete all as specified and directed.
Supply and fixing in replacement of insulators pin type porcelain, vitreous ,white or brown or green insulator of size 50 mm height, 65 mm dia suitable for 1100 V grade including one galvanized mild steel spindle, two GI washers and one nut including removing the existing unserviceable one complete all as specified and directed.
Supply and fixing in replacement of shackle type ,procelain, vitreous, white,brown, or green insulator of size 75mm height and 90mm dia suitable for 1100V, including Galvanised MS straps,washers, insulator bolts,washers and nuts complete,all as specified and as directed.
Supply and fixing in replacement of single Disc insulator assembly for tension with tension clamps for conductors, porcelain, vitreous 145 mm high and 255 mm dia ball and socket type, white, brown or green with tension clamps for conductors, working pressure 11 kV for disc assembly complete,all as specified and as directed.
Material & labour for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled Red, with letters, figures, and coventional skull and bones, in signal white colour and fixed with MS CLAMPS, bolts, and nuts of approved size, for HT 25 X 20 Cm size complete all as specified and directed.
Re-stringing/stretching incl jointing in situ of different sizes of ACSR conductors or GI earth continuity conductors with/ without guarding wires on HT/ LT electric poles at different locations all as ordered manually or by mechanical means to the extent of permissible sag or tension by removing jumpers or bindings from insulators and making fresh binding with aluminium binding wire or aluminium tapes after stringing complete all as specified and directed. Note :- (a) Stretching of 4 conductor will be considered as one span length for measurement purpose. (b) Qty of GI earth wire or ACSR conductor reqd to be replaced or extended during stringing operation shall be measured and paid separately.
All as per item No-26 above but 5 conductor complete all as specified and directed.
All as per item No-26 above but 1/2(1or 2) conductor complete all as specified and directed.
Prunning/trimming the branches of trees if any along HT/LT overhead line, 3 mtr on all side below/above/sides of HT/LT overhead line and removing the same upto 150 mtr away each span not exceeding 60 mtr complete all as specified and directed by Engineer-in-Charge (The above is to be ensured for the entire contract period by cutting/trimming of trees any number of times as required).
Surface Dressing/Cutting of grass,bushes,shrubs and wilds n exc.15 cm deep and removing the same from the site to clear the area of dressing complete all as specified and directed. (The above is to be ensured for the entire contract period for any number of times as required).
Repairs to existing two/ three/Four pole gang operated air break switch horizontal/vertical throw incl taking down old unsv male/female contact set and providing in replacement new male female contact set copper ,spring loaded suitable for 200 Amps complete with jumpers from GOD to OH line & DO to GOD complete with thimbles incl HT tape reqd for repairing HT end termination joint icluding reuired GI pipe rod nd handle complete all as specified and directed.
Material & Labour Painting to HT PCC poles cross arms, clamps, etc including making 05 nos strips with fluorescent post office red and black synthetic enamel paint at a distance of 30 cm wide from plinth block and numbering of poles, complete all as specified and directed.
All as per item 32 here-in- before but on PCC 2 pole structures painting of bracings.
All as per item 32 here-in- before but on PCC 4 pole structures painting of bracings.
All as per item 32 here-in- before but on 33/11 KV 2 pole structures including painting of iron angle structures and bracings.
Material & Labour Painting to LT PCC poles cross arms, clamps, etc including making 05 nos strips with fluorescent Black and White synthetic enamel paint at a distance of 30 cm wide from plinth block and numbering of poles, complete all as specified and directed.
Supplying laying, jointing, testing and commissioning of XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 11000 volts grade, cross sectional area 95 Sqmm 3 core suitable for 11 KV earthed systems complete all as specified and directed by Engr -in-Charge. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc . Excavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid separtely) .
Material & labour for cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination Cold shrinkable type joint complete with jointing material and accessories suitablae for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 Sqmm complete all as specified and directed.
Material & labour for replacement of 80 mm bore GI pipe light grade laid in trenches or fixed to wall/pole for protection of cable/earthing strip etc complete all as specified and directed.
Material & labour for replacement of 50 mm bore GI pipe light grade laid in trenches or fixed to wall/pole for protection of cable/earthing strip etc complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode size 600x600x6.3 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized iron strip 32 x 6 mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 40 mm dia connected to main earth lead on pole or control board and GI pipe light grade 20 mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
All as per item 41 here-in- before but GI wire 4 mm as earthing lead
M & L for replacement for PVC separator in position to keep ACSR conductor 2 Wire on equal spacing all as specified & directed.
M & L for replacement for PVC separator in position to keep ACSR conductor 3 wire on equal spacing all as specified & directed
M & L for replacement for PVC separator in position to keep ACSR conductor 4 wire on equal spacing all as specified & directed
M & L for replacement for PVC separator in position to keep ACSR conductor 5 Wire on equal spacing all as specified & directed
Material & Labour for replacement of GI strip 32 mm x 6 mm from test point upto equipment to be earthed with connecting material like nut bolts etc complete all as specified and directed.
Dismantling insulator any type/ any size from LT/HT poles complete all as directed.
Dismantling unserviceable concrete pole/struts of any size and removing from site .
Dismantling unserviceable stay assembly complete and removing from site
Dismantling unserviceable galvanized stay stranded wire and removing from site
Dismantling unserviceable cross arms, clamps etc and removing from site
Dismantling unserviceable galvanized earth steel wire of any size and existing hexagonal cradle guard HT/LT poles and removing binding wire and removal of the same from site complete all as specified and directed.
Taking down unserviceable/old ACSR conductor any size from over head lines, poles by removing binding wire, service wire, cables and removal from site complete all as specified and directed.
Dismantling of air break gang operated switches/ DO assembly vertical/horizontal mounted including insulators and operating mechanism and removing the same from site and carrying to MES store complete all as specified and directed.
Supply and fixing installation, commissioning and testing in replacement of MCCB 200 Amps fixed on existing panel 415 volt, 4 pole, 25 KA breaking capacity with adjustable current range for overload protection and thermal release including taking down of MCCB complete with spreader terminals all as specified & directed.
All as per item 56 here-in- before but 160 Amps, 4 pole 25 KA complete all as specified and directed.
All as per item 56 here-in- before but 125 Amps ,4 pole,415 volts 25KA breaking capacity complete all as specified and directed..
All as per item 56 here-in- before but 100 Amps ,4 pole,415 volts 25KA breaking capacity complete all as specified and directed..
Supplying laying, jointing, testing and commissioning of LT XLPE of size 150 Sqmm 3.5 coreinsulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of the following sizes all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc.Execavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid for separtely) complete all as specified and directed.
Supplying laying, jointing, testing and commissioning of LT XLPE of size 120 Sqmm 3.5 core insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of the following sizes all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc.Execavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid for separtely) complete all as specified and directed.
Supplying laying, jointing, testing and commissioning of LT XLPE of size 70 Sqmm 3.5 core insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of the following sizes all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc.Execavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid for separtely) complete all as specified and directed.
Supplying laying, jointing, testing and commissioning of LT XLPE of size 35 Sqmm 3.5 core insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of the following sizes all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc.Execavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid for separtely) complete all as specified and directed.
Supplying laying, jointing, testing and commissioning of LT XLPE of size 25 Sqmm 3.5 core insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of the following sizes all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc.Execavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid for separtely) complete all as specified and directed.
Supplying laying, jointing, testing and commissioning of LT XLPE of size 16 Sqmm 4 core insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of the following sizes all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc.Execavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid for separtely) complete all as specified and directed.
Supplying laying, jointing, testing and commissioning of LT XLPE of size 10 Sqmm 2 core insulated screened PVC beded galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor 1100 volts grade complete of the following sizes all as specified and directed. (Note :- cable may be laid in trenches, under road, across the nallah, along poles/walls and in ducts etc.Execavation, earhtwork, sand cushioing, cable cover, pipe for cable protection to be measured and paid for separtely) complete all as specified and directed.
Taking down unserviceable/old LT XLPE insulated screened PVC beded galvanised steel strip or wire armoured electric power cable of any size and removal from site complete all as specified and directed.
Supply & fixing in replacement main switch SPN 32 Amps 240 Volt fixed on pole/panel/wall etc including making connections with existing cable at site complete all as specified and directed.
Servicing of 33 KV SF6 panel, Make ABB, Rated Voltage - 36 kV, cleaning of all carbon particles, dust etc complete and cleaning of all parts, adjusting contacts, springs, locking arrangements, tripping coil circuits (closed/ open) etc cleaning of CT and PT supporting insulators, bush trolley auxiliary contact, male female contact Charging motor and check all wiring including all minor item required for repair complete all as specified and directed. Note:- 1.The rate quoted in this item are excluding testing and adjusting / Calliberation of relay including checking and rectifying the tripping circuit complete.
M & L for cleaning, testing and adjusting the following relay including checking and rectifying the tripping circuit complete, Calibration of relay for 33 KV incoming panel. (a) Master Trip relay, Make-ABB – 01 No (b) Relay for Over current & earth fault, Make-Schnider - 01 No (c) Relay for Winding temp high alarm, Winding temp high trip, Make-ABB – 01 No (d) Relay for Oil temp high alarm, Oil temp high trip, Make-ABB – 01 No (e) Relay for Bocholz Relay alarm, Bocholz relay trip, Make-ABB – 01 No Note: - (I) The tripping system of relays are to be calibrated with 33Kv receiving station DHBVN Hisar and test result in this effect to be submitted to Engr-in- Charge (II) The tripping timing of the relay to be adjusted less than 33KV system at DHBVN Hisar (III) The testing instrument whatever required to test the relays will be arranged by the contractor at his own cost (IV) The test shall be provided from uthorized agency.
Servicing of 11 KV VCB,current rating - 100 Amp/ 60 Amp, Type -UNIVAC, cleaning of all carbon particles, dust etc complete and cleaning of all parts, adjusting contacts, springs, locking arrangements, tripping coil circuits (closed/ open) etc cleaning of CT and PT supporting insulators, bush trolley auxiliary contact, male female contact and check all wiring including minor item required for repair complete all as specified and directed. Note:-1.This item quoted rate not include testing and adjusting the following relay including checking and rectifying the tripping circuit complete.
M & L for cleaning, testing and adjusting the following relay including checking and rectifying the tripping circuit complete, Calibration of relay for 11 KV VCB incoming/ Outgoing panel. (a)Trip circuit suervision Relay, Make - AREVA – 01 No (b) Master Trip Relay, 24 DC Make - AREVA - 01 No (c) Instantaneous earth fault relay, Make-L&T – 01 No (d) Intelligent Panel Meter, Make-L&T – 01 No (e) Ammeter & Voltmeter Note: - (I) The tripping system of relays are to be calibrated with 33Kv receiving station EBS Hisar and test result in this effect to be submitted to Engr-in- Charge (II) The tripping timing of the relay to be adjusted less than 33KV system at EBS Hisar (III) The testing instrument whatever required to test the relays will be arranged by the contractor at his own cost (IV) The test shall be provided from uthorized agency.
Isolating 11 KV HT over head supply from the substation, 2pole /4 pole structure and earth the complete system properly, disconnecting complete electric system of the transformer from HT and LT side including earthing strips, removing transformer and taking out from substation , 2pole /4 pole structure and transporting to authorized service centre/ work shop for repair and back to the installation after repair including installing , commissioning & testing of the following capacity upto 63 KVA. Note : Labour Charges for rewinding of coil and fitting of formed coil.
Isolating 11 KV HT over head supply from the substation, 2pole /4 pole structure and earth the complete system properly, disconnecting complete electric system of the transformer from HT and LT side including earthing strips, removing transformer and taking out from substation , 2pole /4 pole structure and transporting to authorized service centre/ work shop for repair and back to the installation after repair including installing , commissioning & testing of the following capacity 100 KVA to 200 KVA. Note : Labour Charges for rewinding of coil and fitting of formed coil.
Draining out the complete transformer oil and keeping in safe custody in clean and dry containers for reuse. Opening the top cover of the transformer ,disconnecting and taking out complete core assy and dismantling it for checking the serviceability of the coil winding, checking the condition of the body, cleaning the tank and remove sludge/dirt, cleaning the coils limbs, re-fixing of core, core assy , tap changer assembly ,HT/LT Rewinding and connection , terminal studs of HT/LT sides and reassembling of transformer after repairs, refitting the transformer coil including improvement of Insulation Resistance value within desired level by heating or any other method to required level complete all as directed to the entire satisfaction of Engr-in-Charge:- (a) Upto 63 KVA NOTE:- The quoted rates include labour charges for replacing Spares/ parts as required which shall be measured and paid separately as supply only in relevant items .
Draining out the complete transformer oil and keeping in safe custody in clean and dry containers for reuse. Opening the top cover of the transformer ,disconnecting and taking out complete core assy and dismantling it for checking the serviceability of the coil winding, checking the condition of the body, cleaning the tank and remove sludge/dirt, cleaning the coils limbs, re-fixing of core, core assy , tap changer assembly ,HT/LT Rewinding and connection , terminal studs of HT/LT sides and reassembling of transformer after repairs, refitting the transformer coil including improvement of Insulation Resistance value within desired level by heating or any other method to required level complete all as directed to the entire satisfaction of Engr-in-Charge:- (b) 100 KVA to 200 KVA NOTE:- The quoted rates include labour charges for replacing Spares/ parts as required which shall be measured and paid separately as supply only in relevant items .
Material only for primary (HV side) double paper cover aluminium winded coils of existing type size and gauge and in weight complete with including11000 volt grade insulating material for transformer of 50 KVA to 160 KVA
All as per item 78 here-in- before but LV size 415 voltage graded.
Material only for (HV side) copper winded coil of existing type size and gauge 11000 voltage complete with insulating material for transformers 50 KVA to 160 KVA .
All as per item 78 here-in- before but LV side, 415 voltage rade. Note for serial No 78-81: (i) Actual weight of the each coil shall be measured and paid in the relevant items (ii) Labour Charges for rewinding of coil and fitting of formed coil.
Supply and fixing in replacement new off load tap changer assembly complete, making connection and testing complete of the transformer of 50 KVA to 200 KVA capacity complete all as specified and directed.
Supply and fixing in replacement of cork sheet gasket of 06 mm thick for transformer tank complete all as specified and directed.
Supply and fixing in replacement , HV bushing (11000 voltage graded) with heat resistance gasket suitable for following capacity of outdoor/ indoor type transformer up to 63 KVA
Supply and fixing in replacement , HV bushing (11000 voltage graded) with heat resistance gasket suitable for following capacity of outdoor/ indoor type transformer 100 KVA to 200 KVA
Supply and fixing copper terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for HV size 11000 volts grade for following capacity of outdoor / indoor type transformer up to 63 KVA
Supply and fixing copper terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for HV size 11000 volts grade for following capacity of outdoor / indoor type transformer100 KVA to 200 KVA
Supply and fixing LV bushing (415 voltage grade) with heat resistance gasket suitable for following cap of outdoor/indoor type transformer upto 63 KVA.
Supply and fixing LV bushing (415 voltage grade) with heat resistance gasket suitable for following cap of outdoor/indoor type transformer upto 100 KVA to 200 KVA.
Supply and fixing copper terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for LV size 415 volts grade for following capacity of outdoor / indoor type transformer up to 63 KVA
Supply and fixing copper terminal stud, both end threaded complete with double nuts & washers including distance piece both sides and heat resistance gasket suitable for LV size 415 volts grade for following capacity of outdoor / indoor type transformer 100 KVA to 200 KVA.
Material and labour for replacement of silica gel breather filled with silica gel complete for transformer of capacity up to 200 KVA.
Supply & pouring of fresh transformer oil in transformers for topping up the level or replacement complete all as directed by Engineer-in-Charge. (Transformer oil shall confirm to relevant IS -335 and dielectric strength of 45 KV and getting it tested before and after filling complete all as directed and specified.
Material & labour for cleaning sprinkled transformer oil and all other foreign materials from external surface of transformer of capacity up to 63 KVA and preparing the surface to receive paint, and applying one coat of synthetic enamel paint, including writing SM No/MES No with paint on black base complete all as directed and specified.
All as per item 94 here-in- before but for 100 KVA to 200 KVA.
All as per item 94 here-in- before but for 1 MVA or 33/11 KV transformer.
Material & labour for cleaning, rubbing by amren paper and other foreign materials external surface of feeder pillar box/LT panels and preparing the surface for paint, spraying by gun one coat of synthetic enamel paint of existing colour of panel on Internal and External surface, including minor repairing of panels like door hinges with welding/nuts bolts etc complete all as specified and directed .
M & L in repair for connection of LT cable of sizes 70 sqmm 3.5 core with aluminium thimbles for LT side of transformer and panel and disconnection carefully of electric supply as required.
M & L in repair for connection of LT cable of sizes 95 sqmm 3.5 core with aluminium thimbles for LT side of transformer and panel and disconnection carefully of electric supply as required.
M & L in repair for connection of LT cable of sizes 120 sqmm 3.5 core with aluminium thimbles for LT side of transformer and panel and disconnection carefully of electric supply as required.
Material & labour for dehydration and filtration of transformer oil of existing transformer of cap up to 200 KVA , 11/0.433 KV to obtain dielectric strength more than 40 KV at 2.5 mm gap including, testing complete all as specified and directed. Note - Contractor has to bring Centrifusing machine at site for dehydration.
All as per item 101 here-in- before but for 1 MVA, 33/11 KV Transformer.
Supply and fixing in replacement oil temp gauge 0-120 degree Celsius with inbuilt sensor to be fitted on transformer and dismantling of existing unserviceable gauge of any capacity.
Supply and fixing in replacement for Explosion vent diaphragm suitable for 50 KVA to 200 KVA transformer all as directed by Engineer in charge
Supply and fixing in replacement silica gel Crystals complete all as specified and directed.
Supply and fixing in replacement of oil level indicator complete all as specified and directed.
Supply and laying or fixing or passing through pipe,1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape,overall PVC sheathed 6 sqmm 2 core nominal cross section complete all as specified and directed
All as per item 107 here-in- before but size of 10 sqmm 2 core
Material and labour for replacement of silica gel breather filled with silica gel complete for transformer of capacity of 1 MVA.
Taking down existing overhead LT cable of size 95 sqmm 3.5 core and relaying under ground in earth only including making necessary connection with suitable lugs complete all as specified and directed.(Note:- All earth work i.e excavation, return filling, sand filling and bricks etc wiil be measured and paid seperately in respective items.
Taking down existing cable of 33/11 KV HT cable and relaying after testing of cable under ground in earth only including making necessary connection with suitable lugs complete all as specified and directed.(Note:- All earth work i.e excavation, return filling, sand filling and bricks etc wiil be measured and paid seperately in respective items.
Isolating 33 KV HT over head supply from the 33/11KV power trnsformer mounted on platform and earth the complete system properly, disconnecting all complete electric connection of the transformer from both HT side including earthing strips, opening of transformer head and replacing cork sheet/gasket for stopping oil leakage from bushing/body including refixing all the accessories and making good to the entire satisfaction of EIC completeall as specified and directed.Note The rate of hydra crane are included in the quoted rate.
Isolating 11 KV HT over head supply from the substation, 2pole /4 pole structure and earth the complete system properly, disconnecting complete electric system of the transformer from HT and LT side including earthing strips, removing transformer and taking out from substation , 2pole /4 pole structure and transporting to another place For the purpose of Balancing of load on tranformer at various area and after shifting making all connections complete as existing including re installing & testing of the tranformer. Note The rate of hydra crane are included in the quoted rate.
Suplying and laying of gravels of size 25 mm to 40 mm for all electrical sub station, transformer and panel plateform and making even surface complete all as specified and directed.
Supply, installation, commissioning and testing of feeder pillar box cubical type, factory made, CPRI approved ,LT(415 Volts, 50 Hz , 3-phase, 4 wire supply) duly mounted on iron leg of size 50x50x6mm,outdoor type,double door,weather and vermin proof (Protection Class IP-54),with ventilation louvers and 3.15 mm thick MS CRCA sheet and angle iron frame work with both side hinged opening for external, rubber lining, locking arrangement, Powder Coated externally and internally over a coat of red oxide primer complete including grouting of frame with PCC mortor for installation of panel of following : -(For Pump House Panel) (a) Bus Bar chamber comprising 4 Nos aluminium strip bus bars air insulated and PVC sheathed, capacity not lesss than 1.5 times of incomig MCCB with colour coding in separate sheet steel enclosure. (b) Panel mounted Digital Voltmeter , three phase, 96mm X 96 mm square flush mounted-1 No. (c) Panel mounted Digital Ammeter , three phase,, 96mm X 96 mm square flush mounted with suitable ratio of CTs-1 No. (d) LED type/Neon type Indicating lamps panel mounting type RYB-3 Nos. (e) MCCB 415 Volts, 200 Amp, rating 4 Pole,thermal adjustable type, Service Breaking Capacity 25 kA-1 No(incoming). (g) MCCB 415 Volts, 125 Amp, rating 4 Pole,thermal adjustable type, Service Breaking Capacity 25 kA-1 No(Out going). (g) MCCB 415 Volts, 100 Amp, rating 4 Pole,thermal adjustable type, Service Breaking Capacity 25 kA-1 No(Out going) (h) Internal wiring with multistranded copper conductor cable/ PVC Insulated aluminium Strip of suitable size incoming to bus bar and bus bar to outgoing MCCB/MCB-1Job. (i) Fine wiring with single core copper conductor cable for instruments/indicating lamps-1 Job. Note :- MCCBs should be connected with spreader terminals of suitable size.
Isolating 11 KV HT over head supply from the distribution transformer (100/63 KVA) mounted on plateform and earth the complete system properly, disconnecting all complete electric connection of the transformer from both HT/LT side including earthing strips, opening of transformer head or opening of oil tank resovior and replacing cork sheet/gasket for stopping oil leakage from bushing/body including refluxing all the accessories and making good to the entire satisfaction of EIC complete all as specified and directed note the rate of hyfra crane are included in the quote rate.
Taking down old and U/s LT panel board complete
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .