| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.1 LAccepted-AOC | 1 | Accepted-AOC Being lowest and reasonable | |
| 2 | 2₹35.1 L+₹4.8 L (15.8%)Rejected-Finance | 2 | Rejected-Finance Not being the lowest bidder | |
| 3 | 3₹35.3 L+₹5.0 L (16.3%)Rejected-Finance | 3 | Rejected-Finance Not being the lowest bidder | |
| 4 | 4₹35.4 L+₹5.0 L (16.6%)Rejected-Finance PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | 4 | Rejected-Finance Not being the lowest bidder |
Tender Value
₹38 L
EMD Value
₹76,000
Closing Date
16 Mar 2020, 6:00 pmClosed
GE I R AND D RCI, HYDERABAD
GE(I) RND RCI, MILITARY ENGINEER SERVICES, VIGNYANAKANCHA, RCI, HYDERABAD
OUTSOURCING OF SERVICES FOR OPERATION MAINTENANCE OF DUCTABLE PACKAGE TYPE AC PLANTS AT BUILDING No 0201 0306 0406 0603 0901 0902 AD INTEGRATION AVC DTC EHSV EXPOSITION HALL K-15 PETF AND SDTC UNDER GE I RCI HYDERABAD
2020_MES_317792_2
8541
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE I R AND D RCI
MES enlisted Class D category c i and d v Un enlisted Meeting enlistment criteria of D class in MES and having no recovery pending. For further details ref NIT
8 documents required · 8 mandatory
₹500
Yes
GE I R AND D RCI, HYDERABAD
₹76,000
Yes
25 Apr 2020
22 Feb 2020
21 Mar 2020
22 Feb 2020
16 Mar 2020
3 Mar 2020
Amount
Outsourcing of services for operation and periodical checking, day to day maintenance, repairs and attending complaints of ductable Split Type Air Conditioners of capacity 1.5TR-3 No, 3TR-1 No, 7.5TR -16 No and 8.5TR-2 No at K-15 Complex, cleaning of filters, evaporating units, refrigerant controls, electrical controls, rectifying the faults etc., to ensure smooth functioning of Air Conditioners by providing One Refrigeration Mechanic per shift of 8 hours for One shift in a day on all days excluding Sundays and Holidays complete all as specified and directed.
All as per item No 1 above but at Building No 0201, 0306, 0406, 0603, DTC and SDTC of capacity 3 TR - 2 No, 5.5TR - 09 No, 8.5TR - 5 No, 11 TR- 5 No, 5.5 TR- 10 No, 8TR- 4 No & 8.5 TR - 4 No by providing Two Refrigeration Mechanic per shift of 08 hours for One shift in a day on all days excluding Sundays and Holidays complete all as specified and directed.
All as per item No.1 above but for Ductable Split Type Air Conditioners of capacity 8 TR- 4 No, 5.0 TR- 3 No at AD Integration and 5.5 TR - 21 No, 8.5 TR- 3 No & 10.5 TR- 3 No at PETF & EHSV by providing Two Refrigeration Mechanic per shift of 08 hours for One shift in a day on all days excluding Sundays and Holidays complete all as specified and directed.
All as per Sl item No.1 above but for Ductable Split Type Air Conditioners of capacity 8.5TR - 7 No and 5.5TR - 2 No at 0901 & 0902 Building by providing One Refrigeration Mechanic per shift of 8 hours for One shift in a day on all days excluding Sundays and Holidays complete all as specified and directed.
All as per Sl item No.1 above but for Ductable Split Type Air Conditioners of capacity 11 TR - 4 No, 8.5 TR-4 No, 5.5 TR- 2 No at AVC building and Exposition Hall by providing One Refrigeration Mechanic per shift of 8 hours for One shift in a day on all days excluding Sundays and Holidays complete all as specified and directed.
Notes for the serial item No 01 to 05: All T&P for operating, repair and maintenance are deemed to be included in the unit rates quoted.
All stationary for Duty Roster, Attendance register, Wages register, Log sheet book, maintenance record etc., shall be arranged, maintained and submitted by the contractor to Engineer in charge in the first week of every month.
Any loss due to negligence, faulty operation shall be made good by the contractor without any extra cost to the department.
Wage period shall not exceed one month. Wages for all workers employed shall be paid before 7th day of every month through bank account without fail irrespective of whether RAR is claimed or not.
Non compliance on the part of contractor for not making payment of wages to workers as stipulated above shall attract penalty at the rate of Rs 100.00 per shift per worker from RAR/Final Bill. No claim whatsoever on this account will be entertained.
Minimum wages, EPF, ESI, Bonus etc., to the workers shall be paid by the contractor as per Regional Labour/PF Commissioner Gazette Notification including DA all as authorized.
Labour elements for fixing of spares/parts mentioned in this schedule as supply only shall be deemed to include in the unit rate quoted.
The workers employed by the contractor for outsourcing shall be entitled for one day weekly off and the contractor has to provide suitable substitute in the concerned shifts. The unit rate quoted shall be deemed to include for this provision.
The complaints received from the users duly enclosed in the register with docket number and complaint slip has to be maintained with user signature after satisfactory attending the compliant as a token of completion indicating showing the spares replaced wherever applicable.
Supply only Switch fuse unit with enclosure 63Amps, TPN, 415 volts, 50Hz with HRC fuses complete all as specified.
Supply only Switch fuse unit with enclosure 32Amps, TPN, 415 volts, 50Hz with HRC fuses complete all as specified. Make for item No 6 & 7: L&T/Schneider/Siemens/ Havells / C&S
Taking down the old unserviceable compressors, supply and fix new hermetically sealed scroll compressors suitable for package type air conditioner of 5/5.5Ton capacity with mounting assembly such as rubber springs etc., after disconnecting all electric connections, pumping down complete system including alteration of refrigerant piping suction and discharge, pressure testing the complete system with nitrogen after carrying out repairs, flushing out the complete system, vaccumising and gas charging with R-22 refrigerant gas to obtain designed cooling, closing of suction and discharge valves complete all as specified and directed.
All as per item No 8 above but for 7.5/8/8.5Ton capacity package type air conditioner.
All as per item No 8 above but for 10.5Ton capacity package type air conditioner.
All as per item No 8 above but for 3TR capacity package type air conditioner. Make for item No 8 to 11: Kirloskar/Copeland/Voltas/ Tecumesh/Bluestar Note for item No 8 to 11: Labour required for carrying out the job shall be from the outsourcing persons employed under Sl item No 1 to 5 above.
Supply only 'V' belts of size A-22, A -24/25, A-26, A-27, A-28 complete all as specified.
Supply only 'V' belts of size A-41, A-42, A-52, B-41 & B-42 complete all as specified. Make for item No 12 & 13: Dunlop/Fenner/PIX/ Continental
Supply only Single phase preventor, VSP 2, 415V complete all as specified. Make: Minilec/Powertek/GIC.
Supply only 3 pole contactor AC3 rating of 25Amps for complete all as specified.
All as per item No 15 above but of AC3 rating of 18Amps.
All as per item No 15 above but of AC3 rating of 12Amps.
All as per item No 15 above but of AC3 rating of 9Amps. Make for item No 15 to 18: L&T / Legrand / Siemens / Schneider /C&S
Supply only Starting Capacitor 120/150 MFD for split type air conditioners of 3 Ton capacity complete all as specified.
Supply only Running Capacitor 45/36 MFD for split type air conditioners of 3 Ton capacity complete all as specified.
Leak testing of complete gas circulating system with dry nitrogen for a period of 24hours, flushing out complete system, vaccumising, supplying and charging the R-22 refrigerant gas including replacement of unserviceable of copper filter, capillary tube, ‘U’ foam etc., with new ones, cutting, brazing, leak detection and rectification etc., for ductable split type Air Conditioner of 1.5/3 Ton capacity complete all as directed.
All as per item No 21 above but for 10.5/11Ton capacity air conditioner.
All as per item No 21 above but for 5/5.5Ton capacity air conditioner.
All as per item No 21 above but for 7.5/8/8.5Ton capacity air conditioner. Note for item No 21 to 24: Nitrogen to be arranged by the contractor. Labour required for carrying out the job shall be from the outsourcing persons employed under Sl item No 1 to 5 above.
Cleaning of evaporator coil of 1.5 TR to 3 TR capacity Air Conditioner with approved cleaning acid recommended by manufacturer by forced feed method to remove all the dust particles deposited on the coil and fins, cleaning of the filters, greasing to AHU bearings of liquid lines, strainer, expansion valves etc., and testing complete all as specified and directed.
All as per item No 25 above but for 5/5.5Ton capacity.
All as per item No 25 above but for 7.5Ton capacity.
All as per item No 25 above but for 8/8.5/10.5/11Ton capacity. Note for item No 25 to 28: Labour required for carrying out the job shall be from the outsourcing persons employed under Sl item No 1 to 5 above.
Supply only over load relay range from 1.4 to 2.3Amp, 415Volts complete all as specified.
All as per item No 29 above but for relay range of 3 to 5Amp.
All as per item No 29 above but for relay range of 9 to 15Amp.
All as per item No 29 above but for relay range of 14 to 23Amp. Make for item No 29 to 32: Havells/L&T/IndoAsian/ Siemens/C&S
Disconnecting and removing the unserviceable hand remote, cord type with printed panel circuit board (PCB) for 5.5/7.5/8.5/10/10.5 Ton ductable Split AC from position and replacing the same with new hand set remote, cord type with printed circuit board (PCB) including connecting complete all as specified. Make: Carrier or equivalent as approved by GE
Supply only Refrigerant gas R-22
Supply only 32Amp HRC fuses of push/screw type.
Supply only 63Amp HRC fuses of push/screw type. Make for item No 35 to 36: Havells/L&T/Siemens/ IndoAsian
Disconnecting electrically and dismounting from existing position, induction motor of 1 HP capacity, over hauling, re-winding with super enamelled copper wire duly insulated including varnishing, replacing the worn-out bearings, greasing and fixing back in original position, connecting up and testing complete all as directed.
All as per item No 37 above but induction motor of capacity 2 HP
Supply only metallic fan blade for condensor motor suitable for 0.5HP complete all as specified.
Taking down refrigerant control cut out by disconnecting all electrical connections, supply and fixing new refrigerant control cut out of Model MWP-30 including connecting and testing complete all as specified.
Removing the catch all filter from the system and supply and fix new catch all filter complete all as specified. Make: Carrier/Dry All/Danfoss
Supply only FR PVC insulated, round sheathed 4core 2.5Sqmm, multistranded copper conductor industrial cable, 1100V grade, ISI marked complete all as specified.
Supply only Air Filter indigenous washable type suitable for out door unit complete all as specified.
Supply only 4/6 MFD capacitor for fan motor of air conditioners of any capacity complete all as specified.
Supply only 10 MFD capacitor for fan motor of air conditioners of any capacity complete all as specified.
Replacement of Plate Heat Exchanger (PHE) of any capacity including testing and commissioning complete all as directed.
vvcenterprises
CHAVA CONSTRUCTIONS AND ELECTRICAL PROJECTS
Universal refrigeration and Engineering Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .