| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.5 LAccepted-AOC D1C 47A JANAK PURI NEW DELHI 110058 | NEW DELHI | DELHI | DELHI | 110058 | ₹29.5 L Quoted ₹31.4 L | L-1 | Accepted-AOC L-1 |
| 2 | L-2₹36.8 L+₹5.4 L (17.2%)Rejected-AOC 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | ₹36.8 L+₹5.4 L (17.2%) | L-2 | Rejected-AOC L-2 |
| 3 | L-3₹40.4 L+₹9.0 L (28.7%)Rejected-AOC RZ A2 2 CHANAKYA PLACE PART I OPP C 1A BLOCK JANAK PURI NEW DELHI 110059 | NEW DELHI | WEST DELHI | DELHI | 110059 | ₹40.4 L+₹9.0 L (28.7%) | L-3 | Rejected-AOC L-3 |
Tender Value
Refer Docs
EMD Value
₹97,500
Closing Date
10 Dec 2022, 6:00 pmClosed
GE I RND DELHI
MILITARY ENGINEER SERVICE, GARRISON ENGINEER (I) RND, LUCKNOW ROAD, TIMARPUR, DELHI-110054
REPAIR/MAINT OF CENTRAL AC PLANT, VRF SYSTEM AND COOLING APPLIANCES IN ZONE B AT KWC AREA UNDER GE I RnD DELHI
2022_MES_562654_1
GE/RND-67/DLI/2022-2023
Open Tender
Civil Works
Item Rate
180 days
Delhi
Class-D, Cat- c(i)
2 documents required · 2 mandatory
₹500
GE I RND DELHI
₹97,500
Yes
31 Dec 2022
11 Nov 2022
12 Dec 2022
11 Nov 2022
10 Dec 2022
28 Nov 2022
Amount
Disconnecting, dismantling and strip opening of the existing air handling unit of any description and in any position of capacity 50 TR for overhauling and servicing, including taking out existing shaft, blower drum, pulley and de-humidifier pump etc of air handling unit, checking thoroughly serviceability of the parts, fixing the serviceable parts in position, replacement of the defective/non functional/unserviceable parts/spares, reassembling, commissioning, fixing in position and testing of the air handling unit on full load for its smooth and trouble free operation complete all as specified and directed.
Disconnecting & dismantling of existing unserviceable cooling tower, FRP type 50 TR capacity of any description & in any position including dimantling all old connected part/ filters, like motor, FRP casing basin, PVC filling, MS/GI pipe line, sluice valve, stop valve, steel structure frame etc. Servicing/ Overhauling, cleaning, oiling/ greasing and fixing of serviceable parts with new parts, reassembling the cooling towers and connected parts/ items fixed in position for connected to existing system and testing at site on full load complete all as specified and directed.
M&L for overhauling of pump and motor 7.5 to 10HP capacity by opening up and cleaning of all parts such as impeller , rotor, stator, fan cover, greasing including replacing all unserviceable/damaged part like impeller, bearing, bush,seal,shaft,coupling,machine,work etc and reconnecting back and testing complete all as specified and directed.
M&L for overhauling of pump and rewinding of electric motor with super enamelled copper winding wire of existing gauge of capacity 5 to 7.5 HP by opening up and cleaning of all parts such as impeller , rotor, stator, fan cover, greasing including replacing all unserviceable/damaged part like impeller, bearing, bush,seal,shaft,coupling,machine work etc and reconnecting back and testing complete all as specified and directed.
Descaling and cleaning of 50 TR condenser water cooled by circulating the diluted chemical HCL by forced feed method not less than 6hrs duration by opening of the end covers of the condenser brushing the tubes thoroughly,re-fixing back the end cover of the condensers with 3mm thick rubber gasket and testing complete to maintaining desired discharged pressures for water cooled condenser complete all as specified and directed.
M&L for charging of Refrigerant R-407C complete including testing after completion complete all as specified and directed.
M&L for charging of Refrigerant R-410 complete including testing after completion complete all as specified and directed.
Supply & filling of compressors oil including testing complete all as specified and directed.
M&L for fixing leakage in the system, leakage repair including brazing cost, Nitrogen Testing and recommissioning of 50 TR water cooled Chiller complete all as specified and directed.
M&L for rewinding of AHU motor with super enamelled copper winding wire of existing gauge including testing complete all as specified and directed.
S&F new single phase preventer kit including taking out old unserviceable kit complete all as specified and directed.
M&L for fixing all the accessories including cast iron Butterfly Valve 150mm dia including the application of nitrile rubber insulatioin over the valves including taking out old unserviceable valve complete all as specified and directed.
M&L for fixing all the accessories including cast iron Butterfly Valve 100mm dia including the application of nitrile rubber insulatioin over the valves including taking out old unserviceable valve complete all as specified and directed.
Supply, fixing and installation in repair V belt of size A42 complete all as specified and directed.
Supply, fixing and installation in repair V belt of size A43 complete all as specified and directed.
Supply, fixing and installation in repair V belt of size A46 complete all as specified and directed.
Supply, fixing and installation in repair V belt of size A48 complete all as specified and directed.
Supply, fixing and installation in repair V belt of size A49 complete all as specified and directed.
S&F in repair water pressure gauge along with stop cock and fixing arrangement suitable for water pressure 0-16/20 kg/sq cm complete all as specified and directed.
S&F in repair industarial type thermometer of range 0-50 degree centigrade for AC plant as per sample complete all as specified and directed.
S&F in repair suction pressure gauge suitable for suction pressure 0-250 PSI complete all as specified and directed.
S&F in repair discharge pressure gauge suitable for discharge pressure 0-500 PSI complete all as specified and directed.
S&F in repair timer electronic type complete all as specified and directed.
S&F in repair single phase preventer complete all as specified and directed.
S&F in repair power contractor of MNX - 25 complete all as specified and directed.
S&F in repair of LP switch complete all as specified and directed.
S&F in repair of HP switch complete all as specified and directed.
S&F in repair refrigerant copper pipe 15mm bore complete all as specified and directed.
S&F in repair refrigerant copper pipe 12 mm bore complete all as specified and directed.
M&L for Isolating/Disconnecting and dismantling of UNSV compressor 14TR capacity from VRF type AC unit and supply and fixing with new hermatically sealed scroll compressor of 8 HP capacity including leakage testing and pressure testing for 24 hours and gas charging with R-22 refrigerant including testing with Nitrogen gas etc complete all as specified and directed.
S&F new thermostatic expansion valve for 8 HP capacity compressor including taking out old unserviceable valve complete all as specified and directed.
M & L for Servicing of VRF inverter split type 3 phase AC of capacity 14 TR of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and directed. Note:- (i) Any unserviceable items need to be replaced/gas charging etc shall be replaced & paid seperately under respective items. (ii) The cost of dismantling, taking out window AC 1.5/2.0 ton from window and shifting to location where directed for proper washing and servicing and refixing the same shall be deemed to be included in the quoted rate.
S&F MCCB 400 Amps 4 Pole breaking capacity 35KA including taking down old unserviceable MCCB complete all as specified and directed.
S&F MCCB 250 Amps 4 Pole breaking capacity 35KA including taking down old unserviceable MCCB complete all as specified and directed.
S&F MCCB 125 Amps 3 Pole breaking capacity 16KA including taking down old unserviceable MCCB complete all as specified and directed.
S&F MCCB 100 Amps 3 Pole breaking capacity 16KA including taking down old unserviceable MCCB complete all as specified and directed.
M&L for installation of Microprocessor Magnum Controller alongwith Software, installation and controlling arrangement including thimbles control wire etc complete suitable for 50TR AC Plant of make Voltas including taking down old unserviceable complete all as specified and directed.
S&F in repair of AHU small & large filter complete all as specified and directed.
Supply, installation, testing and commissioning in replacement of auto air vent valve of 15 mm dia complete all as specified and directed.
M&L for repair of hot water generator of capacity 30 KW in four banks complete with one slave bank controlled by semi conductor rectifier & other necessary controls, electrical panels etc complete all as specified and directed.
Supply and fixing in replacement including testing of chiller water flow valve with electric control and other works as required at site to make the system functional including welding as required at site etc complete all as specified and directed.
M&L for servicing/ descaling of hot water generator upto 30KW 3 phase 415 Volts including replacement of burnt heaters and calibration testing of all functional to make it fully functional complete all as specified and directed.
M&L for Cleaning of the evaporator coil of 50 TR capacity central air conditioning plant with cleaning agent by forced feed method to remove the unwanted dust formed over the cooling coil fins without disturbing the mounting of the coils and greasing to the AHU blower bearing and tightening of all fasteners etc complete all as specified and directed. Note : The descaling and cleaning works need to be carried out by authorised skilled person by the service dealer or from the Manufacturer.
S&F thermostatic expansion valve suitable for 50 TR capacity central air conditioning plant including cutting and bracing including taking down existing unserviceable thermostatic expansion valve complete all as specified and directed.
Dismantling the compressor of 50 TR from installed position after disconnecting the suction and discharge refrigerant line, open the compressor for carrying out the repairs/ replacement of unserviceable parts, setting of valve reeds, valve plates, bearings, loading and unloading mechanism, pistons with rings, oil seals, oil pumps etc after carrying out necessary lathe work for grinding and polishing the worn out seatings/ housing of the compressor body and assembling with essential minor parts i.e. split pins, nuts, bolts, washers, rubber rings etc and fixing in its position including testing for proper functioning complete all as specified and directed.
M&L for pumping down the refrigerant for re use from the gas line to the chillar unit, removing the existing insulation at the shell and tube chiller and carefully dismantling the refrigerant pipe lines, chilled water circulation pipe lines with valves on both inlet and outlet side, Cut open the chiller in a dust free environment with proper tools and equipments and replacement of the damaged existing copper gas pipe line with new annealed copper pipe line of the existing diameter with minimum 0.5mm thick fixing in original position including necessary brazing/ welding and fixing for smooth functioning. Re-assembling the chiller unit with proper Air tight sealed for leak proof by ensuring filling with Nitrogen gas for 72 hours pressure test and covered the complete chiller with nitrate insulation with minimum 19mm thick before connecting, testing and commissioning complete all as specified and directed. Note : Cut opening and assembling should be done by the authorised dealer. All the spares should be provided through OEM.
M&L for sub main wiring surface/recessed as required with two single core 6 sqmm PVC insulated and unsheathed copper conductor, multistranded 1100 volts grade through and including non metalic rigid PVC conduit including 6 sqmm copper conductor multistranded PVC insulated and unsheathed wire as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing surface complete all as specified and directed.
Material and Labour for earthing complete with copper earth plate electrode 600mmx600mmx3mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. Copper plate connected with copper strip of 25mmx3mm by means of Copper nuts, bolts and washers. Strip shall be laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) Copper strip of 25mmx3mm. (b) Watering pipe GI light grade 40mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly be tightened on GI watering pipe and embeded in PCC earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
M&L in replacement for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x3mm copper strip complete all as specified and directed.
Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron earth wire 4.00 mm dia by means of Copper nuts, bolts and washers. GI wire shall be laid in 20 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a) GI wire of 4 mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit. (GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar @75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
S&F in replacement of MS pipe heavy duty of size 200 dia bore including all accessories and cutting, chessing, welding and testing flow etc complete all as specified and directed.
All same as per item Ser No. 51.00 above but size 100 mm bore.
All same as per item Ser No. 51.00 above but size 80 mm bore
All same as per item Ser No. 51.00 above but size 65 mm bore
All same as per item Ser No. 51.00 above but size 32 mm bore
S&F in repair of Gun-metal, globe or gate valves of size 32 mm dia with iron wheel head, screwed both ends for iron pipe and fixed with all acessories complete all as specified and directed.
S&F in repair of butterfly valve of size 100 mm dia with iron wheel head, screwed both ends for iron pipe and fixed with all acessories complete all as specified and directed.
S&F in repair of Gun-metal, globe or gate valves of size 100 mm dia with iron wheel head, screwed both ends for iron pipe and fixed with all acessories complete all as specified and directed.
M&L for Servicing of the window AC 1.5/2 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and directed. Note:- (i) Any unserviceable items need to be replaced/gas charging etc shall be replaced & paid seperately under respective items. (ii) The cost of dismantling, taking out window AC 1.5/2.0 ton from window and shifting to location where directed for proper washing and servicing and refixing the same shall be deemed to be included in item rate quoted.
All as per item Ser No. 59.00 above but for split type AC/Inverter type AC 1.5/2.0/4.1 Ton
All as per item Ser No. 59.00 above but for VRF inverter split type 3 phase ac of capacity 8 TR.
M&L in replacement Fan Motor of AC (Window/ Split Type) 1.5 TR Capacity of approved Make and required Size to suit existing AC including taking out the unserviceable Fan Motor from the AC complete all as specified and directed.
All as per Item Ser No. 62.00 above but AC (Window/Split Type). 2.0 TR Capacity
M&L Rewinding Fan Motor of AC 1.5/2.00 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate gauge including taking out burnt Winding complete all as specified and directed.
M&L Air circular Blower Fan Motor of AC (Split Type), 1.5 TR/2.0/3.00TR Capacity including taking out unserviceable Air circular Blower Fan Motor complete all as specified and directed.
M&L Air Filter suitable of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filter from AC complete all as specified and directed.
M&L Air Filter suitable of AC (Split type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filter complete all as specified and directed.
M&L Capacitor Running 36 mfd – 45 mfd suitable for new/star rated for AC (Window/Split Type) 1.5 TR/2.0 TR Capacity and of any make including taking out unserviceable Capacitor from AC complete all as specified and directed.
M&L Capacitor Starting 80 mfd – 120 mfd suitable for old ones AC (Window/Split Type) 1.5 TR/2.0 TR Capacity and of any make including taking out unserviceable Capacitor from AC complete all as specified and directed.
M&L Fan Motor Blades AC (Window/Split type) 1.5/2.0 TR capacity including taking out unserviceable Blades of Fan Motor from AC complete all as specified and directed.
M&L Fan Motor Capacitor 4 mfd of suitable for new/star rated AC (Window/Split Type) 1.5/2.0TR capacity including taking our unserviceable Fan motor capacitor from AC complete all as specified and directed.
M&L Fan Motor Capacitor 6 mfd suitable for old ones AC (Window/Split Type) 1.5/2.0TR capacity including taking our unserviceable Fan motor capacitor from AC complete all as specified and directed.
M&L Front Plastic Grill (as per Sample) of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC all as per existing and complete all as specified and directed.
M&L Front Plastic Grill for inner unit (as per Sample) of AC (Split type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC all as per existing complete all as specified and directed.
M&L Runner for air blower motor of AC (split type) AC 1.5/2.00TR capacity (As per sample or as per site requirement) including Runner of Air Blower Motor from AC all as per existing complete all as specified and directed.
M&L Single Pole Contactor 25A Capacity, MR 11W type as approved suitable for AC (Split Type) including taking out unserviceable Single Pole Contactor complete all as specified and directed.
M&L Starting Relay of AC (Window/Split Type) 1.5 TR/2.0/3.00TR Capacity including taking out unserviceable Starting Relay from AC complete all as specified and directed.
M&L Strainer with Capillary Tube of AC Window/ Split Type) 1.5 TR/2.0/3.0 TR Capacity including taking out unserviceable Strainer with Capillary Tube from AC complete all as specified and directed.
M&L Thermostat Switch of AC (Window/Split Type) 1.5 TR/2.0/3.0 TR Capacity including taking out unserviceable Thermostat Switch from AC complete all as specified and directed.
S&F cooling coil suitable for window type room AC 1.5/2 ton including taking out unserviceable cooling coil of capacity 1.5/2 ton.as per sample complete all as specified and directed.
S&F Condensing coil suitable for window type AC 1.5/2 ton including taking out unserviceable Condensing coil of capacity 1.5/2 ton complete all as specified and directed.
S&F Condensing coil suitable for split type AC including taking out unserviceable Condensing coil of capacity 2 ton complete all as specified and directed.
S&F cooling coil suitable for split type AC including taking out unserviceable cooling coil up to capacity 2 ton complete all as specified and directed.
S&F Indoor unit suitable for 1.5 TR split type AC including taking out unserviceable Indoor unit complete all as specified and directed.
S&F outdoor unit suitable for 1.5 TR split type AC with compressor including taking out unserviceable outdoor unit complete all as specified and directed.
S&F Indoor unit suitable for up to 2 TR split type AC including taking out unserviceable Indoor unit complete all as specified and directed.
S&F outdoor unit suitable for up to 2 TR split type AC with compressor including taking out unserviceable outdoor unit complete all as specified and directed.
S&F in replacement of Hermitacally sealed compressor for split/ window type AC capacity 1.5 Ton complete all as specified and directed.
All as per item Ser No. 90.00 above but of split/ window type AC capacity 2.0 Ton.
Taking up or down defective AC 1.5 TR Capacity (Window/Split Type), transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt Compressor Sealed Unit and providing new Compressor Rotary/ Reciprocating as per site requirment of same Capacity from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R22/R410 including re-connection of Electric Connections, to make AC fully functional in all respect and Testing complete all as specified and directed.
All as per Item Ser No. 92.00 above but AC 2.0 TR Capacity (Window/Split Type).
M&L PCB with remote for window type AC up to 2 Ton capacity including taking out unserviceable PCB complete all as specified and directed .
M&L PCB with remote for Split type AC 2/3(1.5x2) Ton capacity including taking out unserviceable PCB complete all as specified and directed .
M&L PCB & motherboard with remote complete set for Inverter Split type AC up to 2 Ton capacity including taking out unserviceable PCB complete all as specified and directed.
M&L in replacement Remote of AC ( Window/Split Type) 1.5/2.0 TR capacity (As per sample or as per site requirement) complete all as specified and directed.
S&F wiring kit suitable for 1.5 to 2.0 ton capacity AC complete including taking out unserviceable wiring kit complete all as specified and directed.
S&F gas charging pin valve complete including taking out unserviceable pin valve complete all as specified and directed.
Taking out window type AC complete unit from any height/ any floor up to four storey building and shifting to another location in the same or other building in the complex including refixing of the unit complete all as specified and directed.
Taking out split type AC indoor and outdoor unit from any height/ any floor up to four storey building by including pumping down the gas into the compressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiion in the same or other building in the complex including refixing of the unit complete all as specified and directed.
Supply and charging the gas refrigerant R22 (including refrigerant) of window type AC upto 2 ton capacity including testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogen gas complete all as specified and directed.
All as per item Ser No. 102.00 above but R- 410/32 for split type AC up to 2 TR capacity.
All same per item Ser No 102.00 above but cassatte type AC 4 TR capacity.
All as per item Ser No 102.00 above but VRF unit 8 TR capacity.
S&F in replacement of casing window type AC including company fitted condensing & cooling coil including PCB except compressor complete all as specified and directed.
M&L for replacement of split valve ¼” for split AC up to 2.00 ton capacity complete all as specified and directed.
All as per item Ser No.107.00 above but 1/2".
S&F in replacement compressor shut off valve 3/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
S&F in replacement compressor shut off valve 5/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
S & F in replacement of electrolyte grade copper tubing of size 1/4" suitable for any type of split type AC including synthetic rubber foam complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building.
All as per item Ser No. 111.00 above but size 1/2".
All as per item Ser No. 111.00 above but size 3/8".
All as per ser item No. 111.00 above but size 5/8".
S&F in replacement PVC conduit 20mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 5 (five) storey complete all as specified and directed.
S&F in replacement PVC conduit 25mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from Acs of Bldgs upto 5 (five) storey complete all as specified and directed.
S&F in replacement of synthetic rubber foam for insulation for refrigerant copper piping of existing size 1/4" to 5/8" internal dia split type AC complete all as specified and directed suitable for the under mentioned sizes. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building.
S&F in replacement Hermatically Sealed compressor for 40/80 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all as specified and directed.
S&F in replacement Hermatically Sealed compressor for 60/120 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all as specified and directed.
S&F in replacement metal plug top 3 pole and earth, 20 Amps, 240 volts suitalbe for sheet metal enslousers complete all as specified and directed.
S&F in repalcement metal enclosures with clad socket & plug top 3 pole and earth, including of MCB SP 25 Amps 240 volts complete all as specified and directed.
S&F in replacement of PVC insulated flexible copper conductor 3 core 1100 volts grade of size 2.50 Sqmm complete all as specified and directed.
S&F in replacement of PVC insulated flexible copper conductor cable 1100 volts grade, 3 core of size 1.5 Sqmm complete all all as specified and directed.
M&L in replacement for submain wiring including PVC caping capping 2 run 4.00 Sqmm cable PVC insulated copper conductor multi - stranded as per FRLS cable drawn through conduit PVC 20mm dia medium grade with all accessories including 4.0 Sqmm single strand copper conductor cable PVC insulated unsheathed for earth continuity connected to common earth dolly and complete all as specified and directed. Note:- 3 run of 4 Sqmm cable and one run of PVC conduit shall be measured as one unit (RM).
S&F in replacement AC stand suitable for out door AC unit up to cap of 2 ton capacity including necessary 40x40x6mm angle iron frame and fixing arrangements like welding, fabrication and nuts & bolts etc upto six stories building complete all as specified and directed.
S&F in replacement reverse valve system made of copper for heating option suitable for 1.5/2.0 ton split / window type AC including appropriate Gas Charging complete all as specified and directed.
M&L for servicing of water cooler of any capacity including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of cooling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed.
Supply and charging the gas in the water cooler of any make and capacity up to 150 ltr capacity including testing and detecting leakage if any with nitrogen gas and vaccum the sytem after rectification of all leakages complete all as specifie and directed.
S&F in replacement thermostat switch suitalbe for water cooler of any make & size complete all as specified and directed.
S&F in replacement starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed.
S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed.
M&L for preparation of old painted surfaces of water cooler by complete removal of old paint, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting complete all as specified and directed.
S&F in replacement fan motor ISI marked suitalbe for water cooler as per existing capacity upto 150 litres of any make complete all as specified and directed.
S&F in replacement of condenser fan of any make suitable for water cooler upto 150 litres capacity complete all as specified and directed.
S&F in replacement 15 mm dia PVC connection of length upto 600mm with PTMT nuts on both ends complete all as specified and directed.
S&F in replacement condenser coil suitable for water cooler upto 150 litres capacity complete all as specifed and directed.
S&F in replacement steel/aluminium waste water tray suitable for water cooler upto 150 litres capacity complete all as specified and directed.
M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside repair/replacement of defective/unserviceable parts, greasing of fan kit, motor, water pump and connected accessories complete all as specified and directed. Note : Unserviceable parts requires replacement shall be measured and paid separately as supply only under respective items of this schedule.
M&L for preparation of surface after complete removal of existing treatment of desert cooler upto 4000 Cfm capacity and painting with two coats of approved synthetic enamel paint over a coat of primer inside & outside including fan/fan blade/brackets complete all as specified and directed. Note : The rates are inclusive of taking down cooler from any height, removal to workshop for painiting and refixing in position after painting.
S&F in replacement of sub mersible water pump for desert cooler complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing complete all as specified and directed.
S&F in replacement desert cooler fan motor,copper wound suitable for upto 450mm sweep SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing complete all as specified and directed.
S&F in repalcement of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as specified and directed.
S&F in replacement plug top 3 pin 5 Amps complete all as specified and directed.
S&F in replacement plug top 3 pin 15 Amps complete all as specified and directed.
S&F in replacement motor capacitor 2.5/3.15/4 mfd complete all as specified and directed.
S&F in replacement front grill made of mild steel complete with air guide vanes suitable for desert cooler of capacity 4000 Cfm complete all as specified and directed.
S&F in replacement of body without side panels made out of galvanised iron sheets of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide primer and two coats of synthetic enamel paint complete and making it functional complete all as specified and directed.
S&F in replacement of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red-oxide primer and two coats of synthetic enamel paint complete with fixing of all spare complete all as specified and directed.
S&F in replacement of float valve with PTMT 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfm complete all as specified and directed.
S&F new wood wool pad,(Khus Khas) set of three covered by GI wire mesh suitable for desert cooler including taking out the old unserviceable pad complete all as specified and directed.
M&L for replacement of switch piano, flush type single pole, one way, 5 Amp 230 V AC ISI Marked complete all as specified and directed.
M&L for replacement of aluminium multi wing Fan blade, best quality as per existing type and size suitable for of desert cooler complete all as specified and directed.
Taking down ceiling fan/exhaust/pedestal/table/air circulating fan of any size or make by disconnection eletric connection and removing from site for rewinding/ overhauling/ engrawing of MES No of fans and fixing the same in eixsting position or as directed by engineer-in-charge with eletric connection and testing complete all as specified and directed.
M & L for overhauling of ceiling fan/pedestal/exhaust/table/aircirculating fan of any size or make opening the fan motor, overhauling by removing dust from field coils including varnishing of field coils and greasing from motor with superior qauality grease for smooth running inlcuding cleaning and washing the blades and assembling of fan motor and refixing at the same place complete all as specified and directed.
M & L for removing of burnt out winding wire from ceiling fan of any make of size 1200/1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material complete all as specified and directed.
All as per item Ser No 156.00 above but for exhaust fans of size 225 mm sweep to 380 mm sweep.
All as per item Ser No 156.00 above but for exhaust fan of size 450 mm sweep
All as per item Ser No 156.00 above but for pedestal fan/Air circulator fan of size 400 mm to 600 mm sweep.
All as per item Ser No 156.00 above but for table fan/wall mounted of 400 mm sweep
M&L for replacement of defective ball bearing for ceilng/table/pedestal/Air-circulators fan of any size complete all as specified and directed.
All as per item Ser No 161.00 above but for exhaust fan of any size complete all as specified and directed.
M&L for replacement of rubber seal of suitable size for ceiling fan complete all as specified and directed.
M&L for replacement of gun metal bush suitable for any type/model/size of fans complete all as specified and directed.
M&L for replacement of ceiling fan regulator five step 60/120 watt electronic type AC 230/240 Volts suitable for 1200/1400 mm sweep complete with all fixing accessories including necessary electric connection complete all as specified and directed.
Taking down geyser of capacity 25 ltrs after disconnecting the electric connections etc and replacing the stainless steel tank with assembly to make the geyser fully functional and refixing the same at its orignal position complete all as specified and directed.
All as per ser item No. 166.00 above but capacity 50 ltrs.
S&F in replacement of Heating element triangle/round type as per existing of capacity 1.5KW of Hot appliances complete all as specified and directed.
All as per item Ser No 168.00 above but capacity 2KW
S&F in replacement of thermostate as per existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed.
Supply and fix in replacement Oil Room Heater 2900 Watt Suitable for 11 Fin,weight 18 Kg complete all as specified and directed.
S&F in replacement of shut off valve as per existing of capacity 25/50 litres for Hot water appliances complete all as specified and directed.
S&F in replacement of Thermo insulation glass wool as per existing of capacity 25/50 litres for Hot water appliances complete all as specified and directed.
S&F in replacement of hot water connection chromium plated 900mm long for geyser of 25/50 litres capacity complete all as specified and directed.
S&F in repair geyser assembly 6/9 holes suitable for 25/50 litres including refixing all connected items complete all as specified and directed.
Note: The contractor shall provide adequate number of manpower for attending day to day complaints. The concerned JE will issue the complaint slip to contractor's supervisor at 9 AM and the complaint shall be attended and rectified on the same day or with in two working days from receipt of complaint failing which Rs. 1000.00 per complaint per day shall be penalised. The payments to above labourers/tradesmen for day to day complaints shall deemed to be included in quoted rates of BOQ items. The decision on the penalty shall be decided by the GE (I) and recovery shall be made in due payment of contractor.
SNOWY ENGINEERING INC
RUCHIKA ENGG.WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .