Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted amount overall reasonable | |
| 2 | L2₹36.2 L+₹2.3 L (6.70%)Rejected-AOC | L2 | Rejected-AOC 2nd lowest hence rejected | |
| 3 | L3₹39.4 L+₹5.5 L (16.1%)Rejected-AOC | L3 | Rejected-AOC 3rd lowest hence rejected | |
| 4 | L4₹39.7 L+₹5.8 L (17.2%)Rejected-AOC | L4 | Rejected-AOC 4th lowest hence rejected | |
| 5 | L5₹41.1 L+₹7.2 L (21.2%)Rejected-AOC | L5 | Rejected-AOC 5th lowest hence rejected |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
23 Jun 2022, 6:00 pmClosed
Garrison Engineer Belgaum
Garrison Engineer Belgaum, Laxmi Tek, Camp Belgaum
REPAIRS TO AREA DRAINS, SEWAGE LINES, MANHOLES, COVER SLABS, HUME PIPE CULVERTS INCLUDING CLEANING OF CHOCKED SEWAGE LINES AND MANHOLES ETC AND OTHER CONNECTED MAINTENANCE WORKS UNDER GE BELGAUM.
2022_MES_526433_1
8836/E8
Open Tender
Civil Works
Item Rate
300 days
Garrison Engineer Belgaum
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Garrison Engineer Belgaum
₹90,000
Yes
11 Jul 2022
26 May 2022
25 Jun 2022
26 May 2022
23 Jun 2022
9 Jun 2022
Amount
MMaterial and labour for 110mm dia PVC (SWR) pipes jointed in CM 1:3 laid in trenches complete with collar inclding demolition and breaking up PCC and existing PVC drain pipes jointed incement mortar and taking out of trenches. and taken as credit complete all as specified and as directed.Note :Make of PVC (SWR) pipe : Finolex/Supreme
Material and labour for RCC pipes class NP-2 ,150mm bore of pipe (ISI Marked) laid in trenches and jointed in cement mortar 1:3 complete with collar inclding demolition and breaking up PCC and SGSW/RCC drain pipes of 150mm dia size jointed in cement mortar and taking out of trenches. and taken as credit complete all as specified and as directed
Descripton all as per item no :02 here in before but for 200mm bore of pipe.
Descripton all as per item no :02 here in before but for 300mm bore of pipe.
Descripton all as per item no :02 here in before but for 450mm bore of pipe.
Descripton all as per item no :02 here in before but for 600mm bore of pipe.
Excavation in trenches n.exc. 1.5m wide and n. exc. 1.5m depth and getting out up to top of drain pipe in hard/dense soil complete all as specified and as directed.
Material and labour for Plain cement concrete type D2 1:4:8(using 40 mm graded stone aggregate) as in foundations, filling and mass concrete. complete all as specified and as directed.
Material and labour for PCC 1:4:8 type D-2 (40mm graded stone aggregate) bed to drain pipes of110mm dia , PVC pipe including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and as directed.
Material and labour for PCC 1:4:8 type D-2 (40mm graded stone aggregate) bed to drain pipes of150mm dia , PVC pipe including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and as directed.
Material and labour for PCC 1:4:8 type D-2 (40mm graded stone aggregate) bed to drain pipes of 200mm dia , PVC pipe including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and as directed.
Material and labour for PCC 1:4:8 type D-2 (40mm graded stone aggregate) bed to drain pipes of300mm dia , PVC pipe including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and as directed.
Material and labour for PCC 1:4:8 type D-2 (40mm graded stone aggregate) bed to drain pipes of450mm dia , PVC pipe including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and as directed.
Material and labour for PCC 1:4:8 type D-2 (40mm graded stone aggregate) bed to drain pipes of600mm dia , PVC pipe including packing under and haunching against the side of pipe after they are laid and tested complete all as specified and as directed.
Material and labour for Precast reinforced cement concrete manholes cover in 1:2:4 type B-1, with using 20mm graded stone aggregate and jointed in CM 1:6 including necessary steel form work/moulds etc and demolition of old manhole covers of any description ,removal of debris off the premises and steel scrap taken as credit complete all as specified and as directed.
Material and labour for PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) as in foundations, filling and mass concrete.including demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thick and ,removal of debris off the premises complete all as specified and as directed.
Material and labour for Pre-cast cement concrete solid block masonary type C1, 1:3:6 (using 20 mm graded stone aggregate) exc 10 cm width and setting in CM 1:6 including Demolition of pre-cast concrete articles and precast concrete block walling of any description and taken as credit complete all as specified and as directed.
Supply and fix in repairs PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls 110mm dia including taking down existing old PVC pipe of any description and taken as credit complete all as specified and as directed . Note :Make of PVC (SWR) pipe : Finolex/Supreme
Material and labour for PCC type C1, 1:3:6 ( using 20mm graded stone aggregate) as in coping including necessary form work complete all as specified and as directed. .
Material and labour for PCC type C1, 1:3:6 ( using 20mm graded stone aggregate) as in coping including necessary form work and demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thick and ,removal of debris off the premises complete all as specified and as directed .
Material and labour for Extra for forming fair finished drain or channel of any inner girth in cement concrete using extra cement including forms moulds mitred/stopped end etc.. complete all as specified and as directed . .
Material and labour dor PCC type B1 1:2:4 (using 20mm graded stone aggregate) as in base of surface channels and drains complete all as specified and as directed.
Material and labour for Rendering in CM 1:4, 15mm thick on fair faces of Brick/concrete masonry surfaces finishing the surface even and smooth without using extra cement. complete all as specified and as directed.
Returning filling in excavated soilincluding spreading, levelling, watering in layers n. exc. 15cm thick complete all as specified and as directed .
Removing excavated soil n. exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and as directed .
Material and labour for Cleaning of existing sewage lines by rodding with split bamboo or any other means as approved and removal of blockage including taking out existing RCC cover slab of manholes of any size without damaging the slab covers to facilitate cleaning and replacing back in original position and cleaning and removal of debris/sludge in pipe line of any type for the following sizes :
100 mm to 150 mm bore of pipe
200 mm bore of pipe
300 mm bore of pipe
Material and labour for Rendering in Brick or PCC block masory on other than fair faces of surfaces in CM 1:6, 15mm thick finishing the surface even & smooth without using extra cement. complete all as specified and as directed
Material and labour for Rendering on fair faces of Brick/concrete masonry surfaces in CM 1:4,15mm thick finishing the surface even & smooth without using extra cement including taking down cement plaster on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etcand removal of rubbish off the premises complete all as specified and as directed.
Material and labour for De-silting of existing gully traps of any size and removing of clogged mud, muck, silt, floating materials, hard materials like stone/ brick bats, etc. from inside the gully trap and connecting pipes from floor trap/ WC and connecting pipes upto 1st manhole including removing the debris outside the MD land complete all as specified and as directed Note: The rate quoted by the contracter shall be deemed to include taking out existing RCC cover slabs of any size without damaging the slab to facilitate cleaning and replacing back in original position .
Material and labour for De-silting of existing manholes of any size, depth not exceeding 1.5m and removing of clogged mud, muck, silt, floating materials, hard materials like stone/ brick bats, etc. from inside the manholes and mouth of pipes and removing the debris outside the MD landcomplete all as specified and as directed. Notes: (a) The rate quoted by the contractor shall be deemed to include taking out existing RCC cover slabs of manholes of any size without damaging the slab to facilitate cleaning and replacing back in original position. (b) The rate quoted by the contractor shall be deemed to include for clearing of vegetations, bushes, shrubs, etc. upto 2m all-around the manhole
Description all as specified in item no : 33 here in before but t depth of manholes exceeding 1.5m and not exceeding 3m complete all as specified and as directed.
Material and labour for Plain cement concrete 1:3:6 type C2 using 40mm graded stone aggregate as in making good road cut portions/ floors, etc.including necessary form work complete all as specified and as directed.
Material and labour for Removal of existing vegetations/ trees not exceeding 30cm girth on top/ sides of buildings including digging out roots, pouring sulphuric acid and making good disturbed portions with cement mortar 1:3 complete all as specified and as directed .
Material and labour for De-silting of existing septic tanks of any size, depth not exceeding 4.5m and removing of clogged mud, muck, silt, floating materials, hard materials like stone/ brick bats, etc. from inside the tank and mouth of pipes and removing the debris outside the MD land complete all as specified and as directed . Note: The rate quoted by the contractor shall be deemed to include for clearing of vegetations, bushes, shrubs, etc. upto 3m all-around the septic tank.
Material and labour for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking bending, spirally for hooping for column, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and as directed .
Description all as specified in item no : 38 here in before but 6 to 8 mm dia complete all as specified and as directed.
M/s B C CHOUGULE
SAGAR ENTERPRISES
M/S MAHADEV M PATIL
SAMARTH ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .