Tender Value
Refer Docs
EMD Value
₹38,700
Closing Date
2 Feb 2023, 4:00 pmClosed
Executive Engineer Electric Division UdhampurJPDCL
Executive Engineer Electric Division UdhampurJPDCL
Creation of 100 KVA Transformer along with HT/ LT Line, installation of 63 KVA SS along with HT/LT line
2023_PDD_202781_1
ED/UDH/117 of 2022-23 dt 18-01-2023
Open Tender
Electrical Works
Turn-key
45 days
in district Udhampur
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Executive Engineer Electric Division UdhampurJPDCL
₹38,700
25 Feb 2023
18 Jan 2023
3 Feb 2023
18 Jan 2023
2 Feb 2023
18 Jan 2023
18 Jan 2023 - 30 Jan 2023
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of 11 KV line on 9 mr ST poles, 30 sqmm ACSR Conductor for creation of 100 KVA Sub Station at Mohalla Saryal village Kotli Jijan W.No. 5..
9 mtr. Long ST Pole (ST-410 SP-33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Braces
30 sqmm ACSR Weasel Conductor
PG Clamps for 30 mm² ACSR Conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint.
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Creation of 100 KVA at Mohalla Saryal village Kotli Jijan W.No. 5.
11/0.433kV, 3-phase 100 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
11kV GO, Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
185 mm² 1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV, min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with tension fitting
GI Channel/Angle/Flat of sizes including clamps
Galvanized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT distribution box for 100 KVA DTR with MCCB for incomer and SfU's for outgoing circuits.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge connectors/PG Clamp
Danger Plates with Clamps
GI Barbed wire for Anti Climbing
3 phase 4 wire LT Prodigy meter with box
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Painting of sub station ST poles/cross arms/clamps with one coat of Red oxide and two coats of aluminium paint
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of LT line 1 phase 2 wire LT on 8 mtr long PCC poles, 30 sqmm ACSR Weasel Conductor for creation of 100 KVA Sub Station at Mohalla Saryal Village Kotli Jijan W.No. 5.
8 mtr. Long PCC Pole (PCC-WL-200KG)
G.I U Clamps for Shackle Insulator
30 sqmm ACSR Weasel Conductor
Shackle Insulator
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip25X3 mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of 11 KV line on 9 mr ST poles, 30 mm Sq. ACSR Conductor for creation of 63 KVA Sub Station at Tikri Mohalla Kodia and Danga.
9 mtr. Long ST Pole (ST-410 SP-33)
GI V Cross -arm with top Bracket including clamps
GI Channel X-arm including clamps and Braces
30 sqmm ACSR Weasel Conductor
PG Clamps for 30 mm² ACSR Conductor
11 KV Polymer composite Pin Insulator 12 KV, 5 KN, lighting impulse 75 KV Positive and 80 KV Negative, Creepage distance 320mm.
11 KV Polymeric Composite Disc insulator 12 KV, min failing load 45 kn, lightening impulse 75 Positive and 80 KV Negative, creepage distance 320mm with fitting
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip 25X3 mm
Painting of 9 mtr ST poles including crossarms/clamps with two coat of Aluminium Paint.
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for Creation of 63 KVA at Tikri Mohalla Kodia and Danga.
11/0.433kV, 3-phase 63 KVA Distribution Transformer with Bimetallic Terminal Connectors Energy Level-2, Aluminium wound, and with LV Cable Box having detachable Aluminium Gland plate
Gapless surge arrestor 9KV, 10KA, LA with polymer housing station type
11kV GO, Switch 3-Phase, 3-Pole, 200 Amp, Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
120 mm² 1.1kV Grade, PVC Insulated Alumnium Stranded Conductor FRLS type
9 mtr. Long ST Pole (ST-410 SP33)
11kV Polymeric composite Disc Insulator 12kV, min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with tension fitting
GI Channel/Angle/Flat of sizes including clamps
Galvanized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239. GI Strip for neutral earthing of size 50 mm x 6 mm & 32mm x 3mm for connection of transformer body, G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with tension fitting
LT distribution box for 63 KVA DTR with MCCB for incomer and SfU's for outgoing circuits.
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Wedge connectors/PG Clamp
Danger Plates with Clamps
GI Barbed wire for Anti Climbing
3 phase 4 wire LT Prodigy meter with box
Cement bottoming 1:2:4 mix as per REC standards 0.5cum/pole
Painting of sub station ST poles with one coat of red oxide and two coats of aluminium paint
Survey, Supply, Transportation, Carriage, Erection, Testing and Commissioning for erection of LT line 1 phase 2 wire LT 30mm sq. On 8 mtr long PCC poles alongwith ACSR Weasel Conductor at Tikri Kodia and Danga.
8 mtr. Long PCC Pole (PCC-WL-200 KG)
G.I U Clamps for Shackle Insulator
30 sqmm ACSR Weasel Conductor
Shackle Insulator
Galvanized Nuts and Bolts.
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing complete by GI Rod 20 mm, 2.5 mtr long through G.I. Strip25X3 mm
Galvanised Stay Set with 50x8mm stay clamp, guy insulator (2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
VEENA CONSTRUCTION CO.
M/S COMBINE GROUP OF ENGINEERS
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .