Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.9 LAccepted-AOC DOCTORS COLONY ROAD NAYAGAON SHADIPUR POST PORT BLAIR 744 106 A N ISLANDS | PORT BLAIR | SOUTH ANDAMANS | A N ISLANDS | 744106 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹25.9 L+₹1.0 L (4.21%)Rejected-AOC 9 EZRA STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹26.4 L+₹1.5 L (6.08%)Rejected-AOC | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹27.8 L+₹2.9 L (11.8%)Rejected-AOC POST BOX NO 539 JUNGLIGHAT P O SRI VIJAYA PURAM 744 103 | SRI VIJAYA PURAM | SOUTH ANDAMAN | ANDAMAN AND NICOBAR ISLANDS | 744103 | L4 | Rejected-AOC Being not L1 | |
| 5 | L5₹28.4 L+₹3.6 L (14.5%)Rejected-AOC | L5 | Rejected-AOC Being not L1 |
Tender Value
₹29 L
EMD Value
₹58,000
Closing Date
7 Mar 2020, 6:00 pmClosed
Col PS Chand, CWE
Commander Works Engineer, Military Engineer Services, Minniebay, Junglighat Post, Port Blair 744103
PROVISION OF HT RMU PANEL WITH CONNECTED ACCESSORIES NEAR CG RHQ SUBSTATION AND PROVN OF 160 KVA SILENT DG SET AT DWEEPIKA CONFERENCE CUM AUDITORIUM UNDER GE HADDO, PORT BLAIR.
2020_MES_320227_1
80881 Provn of HT RMU Panel
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GARRISON ENGINEER HADDO, PORT BLAIR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer, Haddo
₹58,000
Yes
28 Apr 2020
31 Jan 2020
14 Mar 2020
31 Jan 2020
7 Mar 2020
18 Feb 2020
Amount
Supply, laying & testing HT earthed cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor 11000 Volts grade of size 120 Sqmm 3 Core, complete all as specified and as directed by the Engineer in Charge.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, AIuminium conductor cable of size 120 to 185 sq sqmm.
Supply, and fix cable jointing kit for 11 KV grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE, armoured, Aluminium conductor cable of size 120 to 185 sq sqmm.
Supply, install, testing and commissioning of Ring Main unit (RMU) Panel one incomimg and two outgoings, SF6 filled, load break switch as incoming 11KV VCBs-02Nos for out going, 630 Amp outdoor type made out of 3mm thick CRCA sheet dust and vermin proof locking arrangement duly powder coated totally enclosed free standing floor mounting type, HT 11 KV three phase AC supply for internal arc withstand capacity of 21 KA for 1sec, 21 KA breaking capacity short circuit ratings 3 second spring operated and manually charged operating mechanism with copper bus bars complete RMU panel confirming to IS/IEC: 62271 and IP 54 class of protection comprising necessary bus bars connections and following protective and control devices as specified below: (i) Flush mounting trivector meter with TOD, load survey data, 3 MDI and optical port class I. (ii) Potential transformer of 100VA burden for output of 110V to control all relays. (iii) Resin cast CT with ratio 100/ 1-1 with 5VA burden class 5 P10 for protection for 02 outgoing VCBs-Set of three-02Sets. (iv) Self powered microprocessor controlled numeric relay comprising of three over current,one earth fault protection relay high set for both and fault memory universal auxiliary supply-02 Nos for outgoing VCBs Make for Relay : Cat Part No.MICOM P-127 of L&T or equivelant in ABB/ Schneider. (v) Auxiliary relays oil and temperature and bucholtz relay. RMU PANEL SHOULD COMPREISE OF THE FOLLOWING FEATURES:- (i) Push buttons for accepting faults and reset. (ii) LED indicating lamps for (duty control wired up) Item No4 (contd...)
Item No 4 (contd...) (iii) Auto strip (iv) Fault Alarm (v) Trip Circuit Healthy (vi) Trip Circuit Unhealthy (vii) Breaker ON and Breaker OFF (viii) Manual operating arrangement (ix) fuses for protection system (x) One no. internal bus earthing with flat GI strip of size50x 6 mm (xi) Copper bus bar common for out going feeders with PVC sleeves (xii) Complete control panel wiring with copper wire of size not less than 2.5 sqmm. (xiii) Power pack of suitable capacity if required (xiv) Armoured copper cable 12 core 1.5 sqmm control wiring from RMU panel to transformers as required at site. (xv) Civil design for foundation should be as per instructions on manual of manufacturer. NOTE: (i) The RMU shall be tested for high Voltage Primary injection test & Secondary injection test individualy at site after erection before commissioning and the same is deemed to be to included in the quoted rate. (ii) The cost of PCC foundation as per OEM recommendation is deemed to be included in the Quoted rate. MAKE:SIEMENS/ABB/Schneider/L&T.
Excavation in trenches n.exc 1.5 mtrs wide and not exv 1.5 M deep in soft/loose soil and getting out all as specified and as directed.
Returning, filling in, including spreading, levelling and well rammimg in layers not exc 25 cm in soft/loose soil all as specified and as directed.
Removing excavated soil to a distance not exc 50m and depositing where directed at level not exc 1.5 m above starting point all as specified and as directed.
Supply and laying in trenches or in cable ducts, HDPE DWC pipe of size 120mm (OD) x103.5mm (ID) along with connected accessories like couplers, bends, end caps etc. for LT/HT cable protection complete all as specified and as directed by Engineer in charge. [Make: Rex Poly Extrusion Ltd/Tirupati Plastomatics Pvt Ltd.]
Supply, install, testing & commissioning with AMF panel Diesel Engine Driven silent, generating set 160 KVA, 415 volts, 3 Phase 4 wire, 0.8 PF, 50Hz, brushless, 1500 RPM, self excited, self regulated, AC, and conforming to condition as per IS:10001/10002 Engine and alternator rating 160 KVA / 128 KW as per IS ; 13364 complete with relay panel and switch gears for Automatic Starting on Main Failure Control panel having meter and sound proof canopy as per CPCB norms complete with foundation ( as per OEM design) with acoustic enclosure, 12/24 volts, starting system with suitable batteries, turbo charger etc. of capacity 160 KVA DG Set complete all as comprising the following. Make: CUMMINS / KOEL/Cater pillar/Greaves Cotton Ltd. (a) ALTERNATOR : Standard design alternator rated at 160 KVA net out put at site after considering all derating factors, 4 wire 415 volts , 50 cycles, 1500 RPM , self excited self regulated, screen protected drip proof IP-23 enclosure,brushless design with hub and sealed ball/roller bearing with winding on each pole faces,insulating class "H" band of voltage regulation +/- 1% tolerance,revolving field type. Make : Stamford/Alstom/ KOEL/ Cater Pillar. (b) DIESEL ENGINE: Adequate capacity diesel engine suitable to above alternator, water/liquid cooled, to drive independently above alternator and after considering derating as per site conditions directly coupled to alternator through flexible coupling or closed coupling,multi-cylinder, multi-stroke,direct injection, cold starting, Item No 9 (contd...)
Item No 9 (Contd...) (b) Contd../- 1500 RPM as per relevant ISI/BS-5514 with an over load capacity of 10% for one hour in any 12 hours continous running complete with standard accessories all as specified and required for safe running and operation,salient features of accessories shall be as per manufacture's specification under:- (i) Fly wheel housing (ii) Air cleaner dry type (iii)Fuel filter (iv)Fuel injection system including injection pump,solenoid switch noozle as per manufacture's specification (v) Lubricating oil filter,bypass filter,oil cooler (vi) Lubricating oil pump (vii) Turbocharger (viii) Radiator for water cooling (coolant) (ix) 12/24 volts starting system consisting of batteries of capacity as recommended by manufacturer,battery connections with copper leads and with lugs of adequate size,initial charging of batteries,battery charger/generator with regulator,starter motor,starter gear,start and stop push bottoms,ignition key and switch. (x) Residential type exhaust silencer complete with exhaust pipe of 100mm to 125mm dia upto outside the acoustic enclosure,all covered with glass wool wrapped with aluminium foil fo 28 SWG adequate to create draft for safe exhaust without transfering vibrations to building/wall,flexible exhaust pipe complete. Item No 9 (Contd...)
Item No 9 (Contd…) (xi) Engine protection devices including audio and light indiators and cut off system during following instances:- (a) Low lubricating oil pressure (b) High coolant/water temperature (c) Over speeding of engine (xii) Radiator cooling system comprsing of radiator,radiator fan belt, water pump with belts, thermostat (xiii) Hour meter (xiv) RPM meter with indicator (xvi) Water temperature gauge,oil pressure gauge,oil temperature gauge. (xvii) Fuel hoses (xviii) Fuel tank/day tank with level indicator,stop cock,drain plug/valve,breather inlet and outlet connection and all fuel supply lines as required at site and as per manufactures instructions including return and overflow as well as fuel filling arrangement with piping. (xix) Air intake system (xx) Hand priming pump (xxi) Common,base frame of sturdy design suitable for anti vibration mounting (xxii) Permanent concrete foundation for engine and alternator as per manufactures instruction including base concrete and excavation for generator foundation. Item No 9 (contd...)
Item No 9 (Contd…) (viii) Control panel shall have viewing windows. (ix) Emergency spot button shall be easily accessible (x) Provision of electrical illumination inside canopy /enclosure. (xi) High temperature safety for enclosure. (xii) Locking arrangement for all doors and windows with duplicate keys. (xiii) Lifting points shall be provided on base frame. (xiv) Access to fill radiator from outside the canopy. (xv) Specially designed as per manufacturer's standard alternators are to be provided with central or side door to entry into canopy and exist from canopoy. (xvi) Adequate ventilation shall be provided to meet the air requirement to engine and alternator. (e) Anti vibration foundation pads: A set of suitable size and suitable capacity anti vibration pads as required for Generator and engine assembly shall be provided. ( Make : Dunlop or equivalent as approved by GE) (f) Barrel Pump : A barrel pump , rotary type hand pump including 15 mtr long branded hose pipe shall be provided for transferring diesel/oil from bulk storage /barrel to the day tank. (g) Tools : As per manufacturer's specifications. Item No 9 (Contd…)
Item No 9 (Contd…) (g) Documents: Standard documents as per manufacturer specification such as maintenace and operating manual , parts catalouge , display charts such as maintenance and oil change chart/ boards ( for generator and diesel engine ) and log book shall be submitted to Enginerr- In -charge Note : (i) Temperature in the canopy/ compartment shall be less than 5 degree C . It shall adhere to mandatory noise regulation norms. It shall be approved and guaranteed by engine manufacturer. Canopy and insulation shall be suitable for tropical climate. DG set shall comply noise limit 75 db at 1m distance. Contractor shall obtain a copy of approval certificate from any of the institutions approved by Government of India, CPCB from dealer and shall submit to Engineer- In - Charge. (ii) Factory inspection mandatorily to be carried out by rep of Accepting officer. (iii) 12 hours countinuous testing of DG sets at different loads shall be carried out first in presence of Engineer in-Charge and second in the presence of IEM for pre commissioning. The Cost of diesel and testing equipment is deemed to be included in the quoted rate. (iv)The capacity of generating set shall be net after all derating factors as per relevant IS design. (v) The quoted rate includes the cost of disconnecting electrical connections of existing old DG set of 82.5 KVA and shifting the same DG set of MES store yard or any other place at GE Haddo area with the help of Hydra/trolly and the cost includes transportation charges also. (Item 9 Cond..)
Item No 9 (Contd…) (vi) The quoted rate includes breaking of existing PCC foundation and new PCC foundation work to be done as per OEM recommenation.
Earthing complete with GI earth plate electrode of size 60cm x 60cm x 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by using GI strip of size 32x6 mm by means of bolts, nuts, check nuts and washers made of galvanised iron and protected by light grade 15 mm dia GI pipe connected to main switch board or main control board upto 5.00 mtr and GI pipe, light grade, 20 mm bore, for watering and including funnel, wire mesh, RCC (1:2:4 type B1) pit cover and PCC chamber pit with PCC 1:3:6 type C1 (including excavation and earth work, disposal of surplus soil to a distance not exceeding 50 metre) all as specified and shown on plate No 3 of SSR Part I 2009
Prasur Electricals & Engineering Co.
MORESHWAR ELECTRICALS CORPORATION
BHARAT MULTITECH INDUSTRIES PVT LTD
ISLAND SALES ENTERPRISES
KAPOOR AUTOMOBILES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .