Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.1 LAccepted-AOC HNO 52B LAXMI PLACE PHASE II DEORI ROAD NEAR MOHANDEV SCHOOL UKHARA ROAD AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹17.0 L+₹22,373 (1.33%)Rejected-Finance 208 L MODEL TOWN LUDHIANA | LUDHIANA | LUDHIANA | PUNJAB | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹17.6 L+₹85,690 (5.11%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹19.0 L+₹2.3 L (13.4%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹19.4 L+₹2.6 L (15.6%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
6 Jan 2022, 6:00 pmClosed
GE EAST AGRA
GE East Agra, Military Engineer Services, Gwalior House, 62 Taj Road Agra Cantt 282001
REPAIR REPLACEMENT OF SEWAGE LINE INCLUDING CLEANING OF MANHOLE, DESLUDGING OF MANHOLE ETC FOR 509 ABW, MIL WING, SP LINE, GWALIOR ROAD KB LINE,GE OFFICE, ARO, MP LINE ETC UNDER AGE BR II OF GE EAST AGRA
2021_MES_492908_1
9419/E8
Open Tender
Civil Works
Item Rate
330 days
AGRA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE EAST AGRA
₹60,000
Yes
5 Feb 2022
7 Dec 2021
15 Jan 2022
7 Dec 2021
6 Jan 2022
22 Dec 2021
Amount
Excavation in trenches not exceeding 1.5 M wide and not exceeding 1.5 M in depth for foundation, manholes, etc n.exc 10 Sqm plan and getting out in soft/loose soil complete all as specified and directed.
All as per Item No 1 above but exc 1.5M and n.exc 3M deep
All as per Item No 1 above but exc 3.00 M and n.exc 4.50 M deep
Returning, filling in, including spreading, leveling, watering and well ramming in layer n.exc 25 cm thick in each layer all as specified and directed.
Removing of surplus soil /excavated materials to a distance exceeding 50 M but not exc 100M and depositing where directed at a level not exceeding 1.5 M above the starting point complete all as specified and directed.
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar including concrete bedding and haunching complete all as specified and directed for 150mm bore of pipe
All as per Item No 6 above but 200 mm dia
M&L for 150 mm dia SGSW drain pipes grade ‘A’ laid in trenches and jointed in cm 1:1 complete all as specified and directed.
All as per Item No 6 above but 200 mm dia
M&L PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in bed of drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for the 150mm dia of pipe complete all as specified and directed
Description all as per Item No 10 above but 200 mm dia
Demolition and breaking up drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar including concrete bedding and haunching complete all as specified and directed for 300mm bore of pipe
M&L PCC 1:4:8 type D-2, using 40mm graded stone aggregate as in bed of 300mm bore reinforced cement concrete pipes including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed
M&L for reinforced concrete pipe of 300 mm bore, class NP 3 with one collar per lenth of pipe, laid in trenches and jointed in cm 1:1 complete all as specified and directed.
Cutting into existing manholes for connecting new drains making good to pipes and rendering, cutting out existing benching for and forming, branch channel( 1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finish and reforming benching as required for 150 mm dia SWG pipe complete all as specified and directed.
Description all as per Item No 15 here in before but 200 mm bore of pipe
M&L for demolition of reinforced cement concrete of any description and in any position complete all as specified and directed.
M&L for providing pre-cast RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in cover (for manholes and drains) including necessary form work set in CM 1:4 with and including demolition complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately)
S&F MS TMT bars 10 mm dia and above cut to length, bent to shape required including cranking, bending, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
S&F MS Framed work in small articles such as rungs, handles of man hole covers etc., grills,gratings, etc.. with ends of bars shouldered and/or riveted,or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 made to shape and placing in position complete all as specified and directed
Mechanically pumping out sewage water from sump well where required and as directed with taking precautionary measures including tools & plants as required and removing to a distances exc 50 metre but not exc 100M from the site complete (working in foul condition) all as specified directed by Engineer-in-Charge
Cleaning and desludging of existing septic tanks / sump well/ deep man holes of up to 3 metre deep including taking out sludge in any form alongwith all other foreign materials by mechanical equipment or manually or by way of any other suitable means including removal of sludge and other foreign materials out side the MD land by any means complete (working in foul condition) all as specified & directed.
Description all as per Item No 22 above but 3 to 6 mtr deep and ditto--
Demolition of brick work built in cement or lime mortar incl all quoins, arches, pillars etc, complete all as specified & directed
Demolition of cement Concrete in ground floors and pavings n exe 15 cm thickness (below or above ground level) complete all as specified and directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation, filling of mass concrete etc complete all as specified
M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in surface channels and drains complete all as specified and directed.
M&L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in path, floor and road cutting etc including finishd the suface even and smooth complete all as specified and directed.
M&L for brick work with sub class ‘B’ brick, straight curved on plan exc 6m mean radius built in cm (1:4) using old size bricks complete all as specified and directed.
M&L for providing PCC/RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in coping, bands, plinth course, benching and other similar works including use and wast of necessary form work complete all as specified and directed. (Note :- Reinforcement shall be measured and paid separately)
Taking down cement plaster on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed.
M&L Rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 finish surface even and smooth using extra cement complete all as specified and directed.
S&F in repairs 10litres capacity PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets, flushing pipe and PVC connections 15mm size with PTMT nuts of length 450mm inlcuding taking out of old unserviceable connections etc, connecting up new and making good disturbe portion complete all as specified and directed by the Engineer-in-charge
S&F in repairs vitreous china wash down water closet pan pedestal pattern including seat cover white excluding flushing cistern and flush pipe complete all as specified and directed.
S&F in repairs vitreous China squatting pan (Orissa pattern), white, of size 580x440mm white, along with integral foot rests including cast iron 'P' or 'S' trap 100 mm dia, flush pipe, lime concrete bedding inlcuding taking out of old WC pan, old lime concrete bedding, unserviceable connections etc connecting up new and making good disturbe portion complete all as specified and directed by the Engineer-in-charge
S&F in repair PVC (SWR) floor trap (Diameter of outlet 75mm) plain with grating including jointing to waste pipe and fixed in cement concrete 1:2: 4 (type B1)mixed with water proofing liquid as per manufacturor instructions, inlcuding taking out of old unserviceable connections etc, connecting up new and making good disturbe portion complete all as specified and directed by the Engineer-in-charge
S & F in repairs plastic wc seat cover and mild steel chromium plated or aluminised hinging device etc complete all as specified and directed.
S & F in repairs Flushing jet(health faucet) for pedestal pattern WC incl. flexible pipe and Brass Chcomium Plated nuts and blots and water pipe of size 1150 mm long between dia & fixed complete all as specified and drected.
Dismantling floor, hearth wall tiling including cement mortar bedding (but not backing) including rubbish off the premises complete all as specified and directed.
M&L for non skid ceramic coloured tiles (squre/ rectangular) area of each tiles exc 0.06 sqm but n. exc 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed with white cement and coloured pigment to match the tiles over 15mm thick screed bed in CM 1:6.complete all as specified and directed.
M&L for glazed ceramic coloured tiles of size 300x200x6mm thick fixed over and including 10mm thick plaster in CM 1:4 on vertical surfaces such as skirting, dados and risers to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and drected
M&L for total area under AGE B/R-II (509 ABW, Mil Wing, SP Line, Gwalior Road, FON House, 23 Para MP Line, KB Line, MP Line, ARO, GE Office etc) cleaning of all blockage of any type of sewage line ie branch sewer line, main sewer line etc, manholes of any section and depth, any situation by way of cleaning/islodging manholes by using any type of manually, mechanically or by way of any other suitable means including foreign materials as well as rodding of sewer lines and between successive from block manholes where required and ordered by Engineer-in-Charge andkeeping the sewage line functional cleaning trap water closet, soil waste/vent pipe, gully traps upto final drop out let into septic tanks or central sewage system treatmenting in other adjoining Zone/Area of into sewage well (working in foul condition with taking precautionary measures) equipment as required or applicable all as specified and directed
S&F in repair PVC (SWR)pipes 110mm dia single socketed in any length with rubber ring joints laid in trenches or in floors etc complete all as specified and directed .
S&F in repair PVC (SWR)pipes 110mm dia single socketed in any length with rubber ring joints fixed on wall complete all as specified and directed .
S&F in repair PVC (SWR)pipes 75mm dia single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed .
S&F in repair PVC (SWR)pipes 75mm dia single socketed in any length with rubber ring joints fixed on wall complete all as specified and directed .
S&F in repairs PVC (SWR) bends any radius 110mm dia complete all as speified and directed
S&F in repairs PVC (SWR) bends any radius 110mm dia with access doors complete all as speified and directed.
S&F in repairs PVC (SWR) bends any radius 75mm dia complete all as speified and directed
S&F in repairs PVC (SWR) bends any radius 75mm dia with access door complete all as speified and directed
M&L for fixing in repair 75 mm bore PVC (SWR) Vent Cowl complete all as specified and directed.
M&L for fixing in repair 110 mm bore PVC (SWR) Vent Cowl complete all as specified and directed.
M&L for fixing in repair PVC (SWR) gully trap of 125/110 mm dia set and jointing with solvent cement complete all as specified and directed.
S&F in repairs 100 mm bore cast iron soil, waste vent sand cast pipes in any length with or without ears, with lead joints fixed to walls including making good disturbe portion to match the existing complete all as specified and directed by the Engineer-in-charge.
S&F in repairs 100 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access doors and lead joint including making good disturbe portion to match the existing complete all as specified and directed by the Engineer-in-charge.
S&F in repairs 100 mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors and lead joint including making good disturbe portion to match the existing complete all as specified and directed by the Engineer-in-charge.
S&F in repairs 75 mm bore cast iron soil, waste vent sand cast pipes in any length with or without ears, with lead joints fixed to walls including making good disturbe portion to match the existing complete all as specified and directed by the Engineer-in-charge.
S&F in repairs 75 mm bore cast iron bends (any radius), diminishing pieces or tapers (larger bore measured) fitted with oval access doors and jointed with lead joint including making good disturbe portion to match the existing complete all as specified and directed by the Engineer-in-charge.
S&F in repairs 75 mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches fitted with oval access doors and lead joint including making good disturbe portion to match the existing complete all as specified and directed by the Engineer-in-charge.
M/s S. K. Construction Co.
Rahul Construction Co
M/s Salim Mohomad
M/S RISHI RAJ AGRAWAL
M/S Chadha Brothers
SahaDevSingh Constructions
JWALA ELECTRIC CONTRACTORS
N.K. ENTERPRISES
Tulsi Enterprises
M/s D AND R CONSTRUCTION AND SUPPIERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .