Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.1 LAccepted-Finance | ₹22.1 L | L1 | Accepted-Finance Qualified |
| 2 | L2₹24.5 L+₹2.4 L (10.6%)Rejected-Finance | ₹24.5 L+₹2.4 L (10.6%) | L2 | Rejected-Finance Not Qualified |
| 3 | L3₹24.6 L+₹2.5 L (11.3%)Rejected-Finance UDHAMPUR | ₹24.6 L+₹2.5 L (11.3%) | L3 | Rejected-Finance Not Qualified |
| 4 | L4₹26.1 L+₹4.0 L (18.1%)Rejected-Finance | ₹26.1 L+₹4.0 L (18.1%) | L4 | Rejected-Finance Not Qualified |
| 5 | L5₹26.2 L+₹4.1 L (18.6%)Rejected-Finance | ₹26.2 L+₹4.1 L (18.6%) | L5 | Rejected-Finance Not Qualified |
Tender Value
Refer Docs
EMD Value
₹77,300
Closing Date
28 May 2025, 12:00 pmClosed
Executive Engineer,ED JPDCL Batote
Executive Engineer,ED JPDCL Batote
Supply, Survey, Erection,Testing and Commissioning for Creation of 2 No 100 KVA pole mounted sub stations under JJM stageI and StageII at Lower Maha Kund, and 2 No 100 KVA pole mounted sub stations under JJM stageI andStageII at Surranda, Ramban
2025_PDD_277562_1
E NIT 13 of 2025-26
Open Tender
Electrical Works
Turn-key
45 days
Surranda
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,000
Yes
Executive Engineer ED JPDCL Batote
₹77,300
Yes
2 Jun 2025
23 May 2025
28 May 2025
23 May 2025
28 May 2025
23 May 2025
Amount
Creation of 2 No's 100 KVA pole mounted sub stations under JJM stage-I & Stage-II at Lower Maha Kund, Ramban
11/0.433KV, 3-phase Aluminium wound 100 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, , and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 KV ,10 KA ,LA with (polymer/porcelain) housing, Stn. Type
11 kV G.O AB Switch , 3-phase, 3 pole 200 Amp. Vertical type
11 kV Horn Gap Fuse Set 3 Phase 3 pole, 200 Amp
185 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole( ST-540 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Chainlink Fencing of Sub station Yard by way of mass concrete in foundations and chain link fenscing of 6 Ft Height.
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm &depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mmx10 mm & 50mmx6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Fuse set
Wedge Connectors / PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, Jumpers, binding Tape
Erection of HT line on 9 mtrs ST Poles with 30mmsq Conductor for Creation of 2 No's 100 KVA pole mounted sub stations under JJM stage-I & Stage-II at Lower Maha Kund, Ramban
9 Mtr ST pole (ST-410 SP 33)
GI V Cross Arm with top bracket including Clamp
GI channel x-Arm including Clamps and braces
11 KV Polymer Composite Pin Insulator
30 mm Sq ACSR Conductor
PG Clamps for 30 mm sq ACSR Conductor
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti Climb Device With Clamp
Earthing of Poles complete by G.I pipe 40mm or GI Rod 20mm 2.5 mtr long through GI Strip
Red Oxide
Aluminnium Paint
Cement Bottomming 1:2:4 mix as per REC Standards 0.5cum per pole
Creation of 2 No's 100 KVA pole mounted sub stations under JJM stage-I & Stage-II at Surranda, Ramban
11/0.433KV, 3-phase Aluminium wound 100 KVA Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, , and with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 KV ,10 KA ,LA with (polymer/porcelain) housing, Stn. Type
11 kV G.O AB Switch , 3-phase, 3 pole 200 Amp. Vertical type
11 kV Horn Gap Fuse Set 3 Phase 3 pole, 200 Amp
185 mm² Cable, 1.1kV Grade, PVC Insulated Stranded Conductor FRLS type
9 Mtr. Long Pole( ST-540 SP33)
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
GI Channel/Angle/Flat of sizes including clamps
Chainlink Fencing of Sub station Yard by way of mass concrete in foundations and chain link fenscing of 6 Ft Height.
Galvinized Nuts and Bolts.
Earthing of substation --Excavation of earth pit of dia 650 mm &depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mmx10 mm & 50mmx6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
LT Fuse set
Wedge Connectors / PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like aluminium lugs, Jumpers, binding Tape
Erection of HT line on 9 mtrs ST Poles with 30mmsq Conductor for Creation of 2 No's 100 KVA pole mounted sub stations under JJM stage-I & Stage-II at Surranda, Ramban
9 Mtr ST pole (ST-410 SP 33)
GI V Cross Arm with top bracket including Clamp
GI channel x-Arm including Clamps and braces
11 KV Polymer Composite Pin Insulator
30 mm Sq ACSR Conductor
PG Clamps for 30 mm sq ACSR Conductor
11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti Climb Device With Clamp
Earthing of Poles complete by G.I pipe 40mm or GI Rod 20mm 2.5 mtr long through GI Strip
Red Oxide
Aluminnium Paint
Cement Bottomming 1:2:4 mix as per REC Standards 0.5cum per pole
Erection of LT line on 8 mtrs ST Poles with 30mmsq Conductor for Creation of 1 No's 100 KVA pole mounted sub stations under Stage-II at Surranda, Ramban
8 Mtr ST pole (ST-410 SP 15)
Clamp for Shakle Insulator
30 mm Sq ACSR Conductor
16 kN Polymer Shakle Insulator
Galvanized Nuts and Bolts
Danger Plates
Anti Climb Device With Clamp
Earthing of Pole
Red Oxide
Aluminnium Paint
Cement Bottomming 1:2:4 mix as per REC Standard
SHAH BROTHERS (BID ID -2376452)
M/S VAISHNO TRADERS (BID ID -2376966)
JAI CHANDI MAA ENTERPRISES (BID ID -2377041)
BARWAL CONSTRUCTION OPC PRIVATE LIMITED (BID ID -2377031)
GIRI ELECTRICAL & SONS (BID ID -2376396)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .